15000W PID Adjustable Voltage Battery Charger for Lead-Acid & Lithium Battery Packs With PFC
Ultimate Charging Hub for 13.8V – 58.4V Systems: The pinnacle of power delivery for ESS and large-scale AGV fleets. Engineered to hit 13.8V, 14.6V, 27.6V, 29.2V, 55.2V, and 58.4V with uncompromising precision across multiple rated voltage models.
Programmable Massive Power: Unleashes up to 18kW of energy with full Modbus control. Features dedicated dry-contact alarm signals for “Power Good” status monitoring in critical infrastructure.
Grid-Level Safety Protocol: Advanced protection logic allows users to set specific overvoltage shutdown points. The system manages temperature-controlled recovery and short-circuit lockouts automatically.
High-Density Engineering: Reaches up to 93% efficiency with a professional 455x345x251mm design. Ideal for high-vibration and high-temperature industrial settings.
- وصف
| نموذج | HPS-15000-30 | HPS-15000-36 | HPS-15000-48 | HPS-15000-60 | HPS-15000-110 | HPS-15000-220 |
| الجهد المستمر | 30 فولت | 36 فولت | 48 فولت | 60 فولت | 110 فولت | 220 فولت |
| التصنيف الحالي | 400A | 333.3 أ | 250 أ | 200 أ | 109.1A | 54.5 أ |
| النطاق الحالي | 0-400A | 0-333.3A | 0-250A | 0-200A | 0-109.1A | 0-54.5A |
| القوة المقدرة | 15000 واط | |||||
| تموج | 500 مللي فولت | 500 مللي فولت | 600 مللي فولت | 600 مللي فولت | 1000 مللي فولت | 1500 مللي فولت |
| النطاق الأمثل الحالي المستمر | 15-30 فولت | 18-36 فولت | 24-48 فولت | 30-60 فولت | 55-110 فولت | 110-220 فولت |
| دقة الجهد المقنن | ± 1.0% | |||||
| تنظيم الخط | ± 1.0% | |||||
| تنظيم الحمل | ± 1.0% | |||||
| وقت البدء والارتفاع | 1500 مللي ثانية، 700 مللي ثانية/230 فولت تيار متردد (محملة بالكامل) | |||||
| نطاق الجهد | 95-190 فولت تيار متردد (تيار الخرج 50%)، 195-265 فولت تيار متردد (تيار الخرج 100%) | |||||
| نطاق التردد | 45 هرتز-65 هرتز | |||||
| عامل الطاقة | PF≥0.99/230VAC (محملة بالكامل) | |||||
| الكفاءة (الحد الأقصى) | 91% | 91.5% | 92% | 92% | 92.5% | 93% |
| أكيورنت | <110 أ | |||||
| التسرب الحالي | <3.0 مللي أمبير/240 فولت تيار متردد | |||||
| ماس كهربائى | Enter the constant curent and the voltage is less than 10%of therated voltage,turn off and lockthe output after 1 second,and resume after restart | |||||
| أكثر من الحالي | The user can set a delay of 5 seconds after the current value is turned off,and the output can be restored after restart. | |||||
| الضغط الزائد | The user can set the overvoltage value to turn off the output voltage,and resume after restart. | |||||
| أكثر من درجة الحرارة | Turn off the output and automatically recover or restart after the temperature drops | |||||
| تعديل الجهد الناتج | 0-33 فولت | 0-39.6 فولت | 0-52.8 فولت | 0-66 فولت | 0-121 فولت | 0-242 فولت |
| إخراج التعديل الحالي المستمر | 0-400A | 0-333.3A | 0-250A | 0-200A | 0-109.1A | 0-54.5A |
| 485 الاتصالات | مودبوس بروتوكول الاتصالات | |||||
| مصدر طاقة مساعد معزول | 12V0.5A (تحتاج إلى التخصيص) | |||||
| مفتاح الإخراج عن بعد | التشغيل الافتراضي، إيقاف التشغيل عالي المستوى (5 فولت - 12 فولت) (تحتاج إلى التخصيص) | |||||
| إخراج إشارة الإنذار | إشارة الطاقة الجيدة (الاتصال الجاف ≥36 فولت، 0.1 أمبير) (تحتاج إلى التخصيص) | |||||
| درجة حرارة التشغيل | -20-+60 درجة مئوية | |||||
| الرطوبة التشغيلية | -20-90%RHnon-condensing | |||||
| درجة حرارة التخزين والرطوبة | -40-+85℃,10-95%RH non-condensation | |||||
| مقاومة الاهتزاز | i0-500Hz,2G 10mins/T,X、Y、Zaxis 60 minutes each | |||||
| مقاومة العزل | الإدخال إلى الإخراج: 100Mhms/500VDC/25 درجة مئوية/70%RH | |||||
| مقاومة الضغط | /P-O/P:2KVAC IP-FG:2KVAC O/P-FG:0.5KVAC | |||||
| مقاس | 455 × 345 × 251 ملم | |||||
| الوزن الصافي | 22 kg | |||||