{"id":20727,"date":"2026-11-03T10:07:50","date_gmt":"2026-11-03T02:07:50","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/c3z-tof4n-trigger-position-delay-travel\/"},"modified":"2026-11-03T10:07:50","modified_gmt":"2026-11-03T02:07:50","slug":"c3z-tof4n-trigger-position-delay-travel","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/ar\/news\/c3z-tof4n-trigger-position-delay-travel\/","title":{"rendered":"C3Z-TOF4N Trigger Position: Convert Signal Delay into Conveyor Travel"},"content":{"rendered":"<figure class=\"hero\"><a href=\"https:\/\/www.wehopower.com\/ar\/product\/high-efficiency-photoelectric-sensor-c3z-tof4-diffuse-reflective-photoelectric-sensor\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/hero-2.webp\" alt=\"C3Z-family sensor mounted beside a conveyor facing a white carton, with a downstream cross-belt pusher on the fixed outer frame.\" fetchpriority=\"high\" title=\"\"><\/a><figcaption>Conceptual trigger-position layout using the official C3Z-family body: an upstream sensor faces an opaque carton and a separate downstream pusher represents the later useful action. Generic machine hardware and the shared photo do not establish exact TOF4N identity or measured timing. AI-assisted illustration.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original.jpeg\">View original product image<\/a><\/figure>\n<p><strong>Convert detection-chain delay into travel before deciding where a sorting trigger belongs.<\/strong> A C3Z-TOF4N product table lists 10 ms response, but the receiving input, controller task and output device add their own timing. At a moving conveyor, those milliseconds become a physical position change.<\/p>\n<p>This guide helps an OEM controls designer build a first timing budget for a non-safety sorting or inspection trigger. It does not establish a guaranteed trigger accuracy, an approved stopping distance or suitability as a protective device.<\/p>\n<nav class=\"toc\" aria-label=\"On this page\">\n<ol>\n<li><a href=\"#documented-candidate\">Separate range from timing<\/a><\/li>\n<li><a href=\"#time-to-distance\">Use one consistent speed and time basis<\/a><\/li>\n<li><a href=\"#worked-chain\">Add the identified receiving chain<\/a><\/li>\n<li><a href=\"#variation-not-only-mean\">A fixed offset cannot remove all uncertainty<\/a><\/li>\n<li><a href=\"#observe-then-release\">Test the real edge and both transitions<\/a><\/li>\n<li><a href=\"#photo-identity\">Use an accurate TOF4N illustration<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"documented-candidate\">\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u062c\u062f\u0648\u0644 \u0627\u0644\u0645\u062d\u062a\u0648\u064a\u0627\u062a<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u062a\u0628\u062f\u064a\u0644<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/ar\/news\/c3z-tof4n-trigger-position-delay-travel\/#Separate_range_from_timing\" >Separate range from timing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/ar\/news\/c3z-tof4n-trigger-position-delay-travel\/#Use_one_consistent_speed_and_time_basis\" >Use one consistent speed and time basis<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/ar\/news\/c3z-tof4n-trigger-position-delay-travel\/#Add_the_identified_receiving_chain\" >Add the identified receiving chain<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/ar\/news\/c3z-tof4n-trigger-position-delay-travel\/#A_fixed_offset_cannot_remove_all_uncertainty\" >A fixed offset cannot remove all uncertainty<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/ar\/news\/c3z-tof4n-trigger-position-delay-travel\/#Test_the_real_edge_and_both_transitions\" >Test the real edge and both transitions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/ar\/news\/c3z-tof4n-trigger-position-delay-travel\/#Use_an_accurate_TOF4N_illustration\" >Use an accurate TOF4N illustration<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/ar\/news\/c3z-tof4n-trigger-position-delay-travel\/#Trigger_timing_and_travel_budget\" >Trigger timing and travel budget<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/ar\/news\/c3z-tof4n-trigger-position-delay-travel\/#Sources_and_further_reading\" >Sources and further reading<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Separate_range_from_timing\"><\/span>Separate range from timing<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>\u0627\u0644 <a href=\"https:\/\/www.wehopower.com\/ar\/product\/high-efficiency-photoelectric-sensor-c3z-tof4-diffuse-reflective-photoelectric-sensor\/\">WEHO C3Z-TOF4 table<\/a> lists C3Z-TOF4N as NPN and describes diffuse-reflective TOF operation,50\u20134000 mm adjustable distance and 10 ms response. The stated reference target is 10 \u00d710cm white non-glossy paper. A4m range does not imply a faster response, a smaller spot or an analog distance output.<\/p>\n<p>Confirm the real target can be detected at the chosen geometry before using the timing number. No detailed jitter bound, separate operate\/reset maximum or complete application timing distribution has been established from the inspected page. Keep those missing items visible in the design record.<\/p>\n<\/section>\n<section id=\"time-to-distance\">\n<h2><span class=\"ez-toc-section\" id=\"Use_one_consistent_speed_and_time_basis\"><\/span>Use one consistent speed and time basis<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For constant speed, additional travel is <strong>d = v \u00d7 t<\/strong>. Convert milliseconds to seconds before multiplication. At 0.80 m\/s,10 ms corresponds to 0.80 \u00d70.010 =0.008m, or <strong>8 mm<\/strong>. This is the geometric travel associated with the catalog response figure, not a verified position-error bound for the sensor.<\/p>\n<p>\u0627\u0644 <a href=\"https:\/\/www.ia.omron.com\/support\/guide\/43\/explanation_of_terms.html\" target=\"_blank\" rel=\"noopener\">OMRON photoelectric definition<\/a> describes response time as the delay between a light-condition change and the output operation or reset. The material&#8217;s physical edge, the optical threshold and the point at which the machine acts are different events. Choose and label the event used by each timing entry.<\/p>\n<\/section>\n<section id=\"worked-chain\">\n<h2><span class=\"ez-toc-section\" id=\"Add_the_identified_receiving_chain\"><\/span>Add the identified receiving chain<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"fig-diagram\" class=\"diagram\"><img decoding=\"async\" class=\"technical-desktop\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-2.svg\" alt=\"Response and chain delays converted into conveyor travel at 0.80meters per second\" loading=\"lazy\" title=\"\"><img decoding=\"async\" class=\"technical-mobile\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-mobile-2.svg\" alt=\"Response and chain delays converted into conveyor travel at 0.80meters per second\" loading=\"lazy\" title=\"\"><figcaption>Hypothetical constant-speed budget;not a qualified accuracy or stopping-distance result.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-2.svg\">Open full-size technical illustration<\/a><\/figure>\n<p>In a hypothetical budget, assume 10 ms sensor response,3 ms input filtering, an asynchronous 8 ms controller task with an assumed 0\u20138 ms wait and 2 ms command-output delay. With the other example delays held fixed, the electronic delay spans <strong>15\u201323 ms<\/strong>, corresponding to <strong>12.0\u201318.4 mm<\/strong> travel at 0.80 m\/s. The 8 ms task-wait span alone contributes a <strong>6.4 mm full travel span<\/strong>; it is not an RMS accuracy or a measured jitter specification. If a separate actuator adds 35 ms before the useful mechanical action, total time becomes 58 ms and travel becomes 46.4 mm.<\/p>\n<p>Only the 10 ms entry comes from the cited C3Z table; the others are invented example inputs. Replace them with the actual receiver, controller and actuator evidence. Do not combine average values and maximum values while labeling the result a worst case. A documented task jitter or communication interval may also matter.<\/p>\n<\/section>\n<section id=\"variation-not-only-mean\">\n<h2><span class=\"ez-toc-section\" id=\"A_fixed_offset_cannot_remove_all_uncertainty\"><\/span>A fixed offset cannot remove all uncertainty<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Moving a sensor upstream can compensate a repeatable delay at a defined speed. It does not eliminate timing variation. In the preceding hypothetical system, a 15\u201323 ms electronic-delay range gives <strong>0.80 \u00d70.008=6.4 mm<\/strong> of full travel spread at 0.80 m\/s. Speed variation adds another contribution, and acceleration invalidates a single constant-speed offset unless the motion is otherwise tracked.<\/p>\n<p>For tight registration, record the distribution of edge-to-action position using a suitable measurement method. The acceptance question is whether the complete chain meets the project&#8217;s position tolerance across speed, target and operating conditions. It cannot be answered by subtracting one nominal sensor delay from the machine program.<\/p>\n<\/section>\n<section id=\"observe-then-release\">\n<h2><span class=\"ez-toc-section\" id=\"Test_the_real_edge_and_both_transitions\"><\/span>Test the real edge and both transitions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Define the target edge, sensor distance, background and active output transition. Include the shortest target exposure and clear interval to ensure the intended events are not merged or filtered. Record local output, raw input, program event and actuator action where practical. An output indicator viewed by eye cannot establish millisecond timing.<\/p>\n<p>Retain the speed and configuration with the result. A faster conveyor setting, changed input filter, controller task revision or different target surface can change the position budget. If the required tolerance is unsupported, redesign the sensing\/position architecture rather than describing an unverified result as precision TOF performance.<\/p>\n<\/section>\n<section id=\"photo-identity\">\n<h2><span class=\"ez-toc-section\" id=\"Use_an_accurate_TOF4N_illustration\"><\/span>Use an accurate TOF4N illustration<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The official TOF4 gallery repeats a different sensor visibly marked C3Z-T15P-D. It is not a valid TOF4N product photograph and cannot establish the installed exterior or wiring. Obtain an accurate TOF4N source before making its application cover; editing the printed model would remove rather than solve the identity evidence.<\/p>\n<figure id=\"fig-original\" class=\"product-original\"><a href=\"https:\/\/www.wehopower.com\/ar\/product\/high-efficiency-photoelectric-sensor-c3z-tof4-diffuse-reflective-photoelectric-sensor\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original.jpeg\" alt=\"Official WEHO C3Z-family photograph with its complete coiled factory cable; exact selected model appearance unverified.\" loading=\"lazy\" title=\"\"><\/a><figcaption>Official WEHO C3Z-family reference photograph. This unmarked view does not verify the selected model suffix, optical operating principle or wire functions; the original complete cable and tail are retained.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original.jpeg\">View original image<\/a><\/figure>\n<p class=\"source-list\"><a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2024\/08\/C3Z-Series.jpeg\">Official WEHO family photograph source<\/a><\/p>\n<\/section>\n<section class=\"cta\">\n<p>Send <a href=\"https:\/\/www.wehopower.com\/ar\/contact\/\">\u0648\u064a\u0647\u0648<\/a> the C3Z-TOF4N candidate, target and background, speed range, required action position, receiving chain and timing budget. Ask for the applicable response conditions and current exact-model information before releasing the trigger architecture.<\/p>\n<\/section>\n<section id=\"worksheet\" class=\"sheet\">\n<h2><span class=\"ez-toc-section\" id=\"Trigger_timing_and_travel_budget\"><\/span>Trigger timing and travel budget<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"sheet-row\"><label>Exact marking\/revision<input aria-label=\"Exact marking\/revision\"><\/label><label>Target edge<input aria-label=\"Target edge\"><\/label><label>Speed range<input aria-label=\"Speed range\"><\/label><label>Required position tolerance<input aria-label=\"Required position tolerance\"><\/label><label>Input\/controller\/actuator models<input aria-label=\"Input\/controller\/actuator models\"><\/label><\/div>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u0627\u0644\u0627\u0633\u062a\u0634\u0639\u0627\u0631<\/th>\n<th scope=\"col\">Timing source\/condition<\/th>\n<th scope=\"col\">Bound or typical<\/th>\n<th scope=\"col\">Travel<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Receiver<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Filter\/sampling<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Evidence<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Travel<\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Controller\/output<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Task\/command delay<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Evidence<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Travel<\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Actuator<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Command-to-useful-action<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Measured evidence<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Travel<\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Whole chain<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Variation\/range<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Observed position<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Release<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Blank project worksheet. Enter verified project data; example calculations above are not measurements.<\/p>\n<\/section>\n<section class=\"source-list\">\n<h2><span class=\"ez-toc-section\" id=\"Sources_and_further_reading\"><\/span>Sources and further reading<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><a href=\"https:\/\/www.wehopower.com\/ar\/product\/high-efficiency-photoelectric-sensor-c3z-tof4-diffuse-reflective-photoelectric-sensor\/\">WEHO C3Z-TOF4 table<\/a><\/li>\n<li><a href=\"https:\/\/www.ia.omron.com\/support\/guide\/43\/explanation_of_terms.html\" target=\"_blank\" rel=\"noopener\">OMRON photoelectric response-time definition<\/a><\/li>\n<\/ol>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Convert C3Z-TOF4N response time and conveyor speed into a position budget. Record the other timing and mechanical terms before setting the trigger.<\/p>","protected":false},"author":2,"featured_media":20694,"parent":0,"menu_order":174,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-20727","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/news\/20727","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/comments?post=20727"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/news\/20727\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/media\/20694"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/media?parent=20727"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/news_category?post=20727"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}