{"id":22094,"date":"2026-11-15T18:08:13","date_gmt":"2026-11-15T10:08:13","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/power-supply-thermal-test-stabilization\/"},"modified":"2026-11-15T18:08:13","modified_gmt":"2026-11-15T10:08:13","slug":"power-supply-thermal-test-stabilization","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/","title":{"rendered":"Power Supply Thermal Tests: Compare Stabilized Cabinet Conditions"},"content":{"rendered":"<p><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Define a stabilization criterion before comparing cabinet temperature results.<\/li>\n<li>Record local ambient temperature, load, enclosure state and measurement position.<\/li>\n<li>Separate absolute temperature limits from temperature-rise comparisons.<\/li>\n<li>A cooler surface reading alone does not prove a better thermal design.<\/li>\n<\/ul>\n<figure data-role=\"hero\"><a href=\"https:\/\/www.wehopower.com\/ar\/product\/60w-ac-to-dc-switched-mode-power-supply\/\" aria-label=\"View LRS-60-12 product details\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-60-12-application.avif\" width=\"1200\" height=\"675\" alt=\"Power Supply Thermal Tests: Compare Stabilized Cabinet Conditions  title=\" data-image-role=\"hero\" loading=\"eager\" power supply thermal tests: compare stabilized cabinet conditions title =\"\"><\/a><figcaption>Application illustration; not a customer installation or test. The AI-assisted scene retains original LRS-60-12 product artwork. This cabinet context does not portray the article&#8217;s hypothetical measurements or constitute installation approval. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-lrs-60-12-cabinet-application.avif\">View source image<\/a><\/figcaption><\/figure>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u062c\u062f\u0648\u0644 \u0627\u0644\u0645\u062d\u062a\u0648\u064a\u0627\u062a<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u062a\u0628\u062f\u064a\u0644<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#Why_are_two_cabinet_temperature_readings_often_incomparable\" >Why are two cabinet temperature readings often incomparable?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#How_do_you_separate_absolute_temperature_from_temperature_rise\" >How do you separate absolute temperature from temperature rise?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#Hypothetical_Cabinet_Comparison_Example\" >Hypothetical Cabinet Comparison Example<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#What_belongs_in_a_thermal_comparison_record\" >What belongs in a thermal comparison record?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#How_should_you_run_a_useful_comparison\" >How should you run a useful comparison?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#Which_results_should_not_be_described_as_stabilized\" >Which results should not be described as stabilized?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#What_should_an_OEM_send_WEHO_for_a_thermal_discussion\" >What should an OEM send WEHO for a thermal discussion?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#Engineering_FAQ\" >Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#How_many_minutes_should_a_power_supply_warm_up_before_a_thermal_test\" >How many minutes should a power supply warm up before a thermal test?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#Is_temperature_rise_the_same_as_maximum_operating_temperature\" >Is temperature rise the same as maximum operating temperature?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#Can_I_compare_a_thermal-camera_reading_with_a_contact-probe_result\" >Can I compare a thermal-camera reading with a contact-probe result?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#Does_a_stable_enclosure_temperature_prove_internal_components_are_within_limits\" >Does a stable enclosure temperature prove internal components are within limits?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.wehopower.com\/ar\/news\/power-supply-thermal-test-stabilization\/#Can_a_repeating_machine_cycle_have_a_valid_thermal_comparison\" >Can a repeating machine cycle have a valid thermal comparison?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"why-are-two-cabinet-temperature-readings-often-incomparable\"><span class=\"ez-toc-section\" id=\"Why_are_two_cabinet_temperature_readings_often_incomparable\"><\/span>Why are two cabinet temperature readings often incomparable?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Two temperature readings can describe different stages of warm-up, different local air temperatures or different equipment loads. Comparing only their displayed values can therefore produce a false design conclusion. The decision is whether the proposed cabinet arrangement meets its applicable limits under a repeatable, representative thermal condition.<\/p>\n<p>\u0627\u0644 <a href=\"https:\/\/www.wehopower.com\/ar\/product\/60w-ac-to-dc-switched-mode-power-supply\/\">LRS-60-12 product reference<\/a> provides an enclosed supply example for this method. The article does not publish a measured LRS-60 temperature, a new derating curve or an approved installation clearance. Product operation still needs the applicable version&#39;s documented conditions.<\/p>\n<p>The immediate output is a usable comparison protocol: define the measurement locations, operating state and point at which the result becomes eligible for comparison. This is more informative than taking whichever photograph happens to show the lowest temperature.<\/p>\n<nav aria-label=\"Article contents\">\n<details>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#why-are-two-cabinet-temperature-readings-often-incomparable\">Why are two cabinet temperature readings often incomparable?<\/a><\/li>\n<li><a href=\"#how-do-you-separate-absolute-temperature-from-temperature-rise\">How do you separate absolute temperature from temperature rise?<\/a><\/li>\n<li><a href=\"#what-belongs-in-a-thermal-comparison-record\">What belongs in a thermal comparison record?<\/a><\/li>\n<li><a href=\"#how-should-you-run-a-useful-comparison\">How should you run a useful comparison?<\/a><\/li>\n<li><a href=\"#which-results-should-not-be-described-as-stabilized\">Which results should not be described as stabilized?<\/a><\/li>\n<li><a href=\"#what-should-an-oem-send-weho-for-a-thermal-discussion\">What should an OEM send WEHO for a thermal discussion?<\/a><\/li>\n<li><a href=\"#engineering-faq\">Engineering FAQ<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<h2 id=\"how-do-you-separate-absolute-temperature-from-temperature-rise\"><span class=\"ez-toc-section\" id=\"How_do_you_separate_absolute_temperature_from_temperature_rise\"><\/span>How do you separate absolute temperature from temperature rise?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Absolute temperature and rise above local ambient answer different questions. Absolute temperature is relevant when comparing a point with an applicable temperature limit. Temperature rise can help compare thermal behavior under controlled conditions, but it does not remove the absolute limit.<\/p>\n<h3 id=\"hypothetical-cabinet-comparison-example\"><span class=\"ez-toc-section\" id=\"Hypothetical_Cabinet_Comparison_Example\"><\/span>Hypothetical Cabinet Comparison Example<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Assume test A records a selected surface point at 48\u00b0C with local air at 25\u00b0C after the defined stabilization criterion is met. Its rise is 48 \u2212 25 = 23 K. Assume test B records the same defined point at 52\u00b0C with local air at 30\u00b0C, also after stabilization. Its rise is 22 K.<\/p>\n<p>Test B has the higher surface temperature but the slightly lower rise. That does not prove test B is superior: load, airflow, measurement uncertainty and the definition of local ambient must also match. The example only demonstrates why subtracting the appropriate reference temperature changes the comparison.<\/p>\n<figure data-role=\"technical\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-60-12-engineering-example.svg\" width=\"1200\" height=\"675\" alt=\"Power Supply Thermal Tests: Compare Stabilized Cabinet Conditions  title=\" data-image-role=\"technical\" power supply thermal tests: compare stabilized cabinet conditions title =\"\"><figcaption>Conceptual Engineering Diagram. Test A: surface 48 \u00b0C, local air 25 \u00b0C \u2192 rise 23 K. Test B: surface 52 \u00b0C, local air 30 \u00b0C \u2192 rise 22 K. Higher surface temperature does not prove greater rise. A stabilization rule must be defined before comparison. These are stated example inputs or project states, not measured product performance or manufacturer limits. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-60-12-engineering-example.svg\">View source image<\/a><\/figcaption><\/figure>\n<p>If the equipment imposes an absolute limit at the measured point, compare each absolute temperature with that limit. Do not use a smaller rise to excuse an excessive absolute value. Conversely, a higher absolute temperature in a warmer room is not enough by itself to conclude that a cabinet modification increased thermal resistance.<\/p>\n<p>The values above are hypothetical, not manufacturer acceptance limits or customer results. The 1 K difference between the rises may be insignificant relative to uncertainty and repeatability. Define the decision rule before claiming a change based on a small difference.<\/p>\n<h2 id=\"what-belongs-in-a-thermal-comparison-record\"><span class=\"ez-toc-section\" id=\"What_belongs_in_a_thermal_comparison_record\"><\/span>What belongs in a thermal comparison record?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Control the variables that influence heat generation and heat removal. An unchanged output voltage does not prove an unchanged output load. An open cabinet door can alter airflow and make an earlier closed-door result unsuitable for direct comparison.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th>Record item<\/th>\n<th>Required definition<\/th>\n<th>Comparison risk<\/th>\n<th>Keep with result<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u062d\u0627\u0644\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td>Load, duty cycle and input<\/td>\n<td>Different heat generation<\/td>\n<td>Measured electrical conditions<\/td>\n<\/tr>\n<tr>\n<td>Enclosure state<\/td>\n<td>Door, filters and adjacent equipment<\/td>\n<td>Different cooling path<\/td>\n<td>Assembly revision and photographs<\/td>\n<\/tr>\n<tr>\n<td>Measurement point<\/td>\n<td>Repeatable physical location<\/td>\n<td>Different surface or air region<\/td>\n<td>Sensor placement method<\/td>\n<\/tr>\n<tr>\n<td>Stabilization<\/td>\n<td>Trend rule and observation interval<\/td>\n<td>Warm-up mistaken for steady state<\/td>\n<td>Time-stamped trend<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Use the applicable product, equipment or test procedure to establish a stabilization criterion. If the project needs its own comparison method, have the responsible engineer define and document it. This article does not impose a universal warm-up time or an invented allowable temperature-change rate.<\/p>\n<p>For equipment with a repeating duty cycle, a constant temperature may never occur. Define a repeatable cyclic condition instead: for example, compare equivalent cycle phases after the temperature pattern has become repeatable under the approved criterion. Retain the cycle maximum and minimum when they affect the requirement.<\/p>\n<h2 id=\"how-should-you-run-a-useful-comparison\"><span class=\"ez-toc-section\" id=\"How_should_you_run_a_useful_comparison\"><\/span>How should you run a useful comparison?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Run the baseline and proposed arrangement using the same defined procedure. Record the complete time trend, not only the final selected value. A modification can change warm-up speed without changing the eventual maximum, or alter a cyclic peak that an average value hides.<\/p>\n<ol>\n<li>Identify the exact supply, load arrangement, enclosure revision and applicable operating limits. Select measurement points that address the actual design question.<\/li>\n<li>Install the sensors using the qualified method. Record local-air and surface positions, attachment and measurement-system settings.<\/li>\n<li>Establish the specified input, output load and enclosure condition. Log the temperature trend and any relevant changes in equipment state.<\/li>\n<li>Apply the documented stabilization or cyclic-repeatability rule. Retain the evidence showing when it was met.<\/li>\n<li>Compare the intended quantities using the uncertainty and acceptance rule. Record both absolute values and rises where each is relevant.<\/li>\n<\/ol>\n<p>Surface measurement method matters. A contact sensor can be influenced by attachment and lead conduction. An infrared reading depends on the surface and instrument setup; shiny metal can produce misleading results if emissivity and reflections are not addressed. Use an appropriate method and retain its configuration.<\/p>\n<p>Do not open the supply to place a sensor on an internal component unless an approved procedure and qualified personnel require that measurement. Keep sensors and leads clear of terminals and moving parts. Apply the equipment&#39;s isolation and energized-test controls to installation and measurement work.<\/p>\n<h2 id=\"which-results-should-not-be-described-as-stabilized\"><span class=\"ez-toc-section\" id=\"Which_results_should_not_be_described_as_stabilized\"><\/span>Which results should not be described as stabilized?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Do not describe a result as stabilized merely because a fixed amount of time has elapsed. An arbitrary delay can be too short for one assembly and unnecessarily long for another. A supply in isolation and the same supply inside a loaded cabinet can have different thermal time behavior.<\/p>\n<figure data-role=\"product\"><a href=\"https:\/\/www.wehopower.com\/ar\/product\/60w-ac-to-dc-switched-mode-power-supply\/\" aria-label=\"View LRS-60-12 product details\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-60-12-product-reference.avif\" width=\"1000\" height=\"1000\" alt=\"Power Supply Thermal Tests: Compare Stabilized Cabinet Conditions  title=\" data-image-role=\"product\" power supply thermal tests: compare stabilized cabinet conditions title =\"\"><\/a><figcaption>Official LRS-60-12 product photograph retained as an identity reference. Numerical examples in this article are hypothetical and are not product test results. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-lrs-60-12-product-source.jpg\">View source image<\/a><\/figcaption><\/figure>\n<p>\u0627\u0644 <a href=\"https:\/\/www.wehopower.com\/ar\/product\/60w-ac-to-dc-switched-mode-power-supply\/\">LRS-60-12 operating documentation<\/a> remains the reference for product limits. The enclosure comparison adds equipment-level evidence; it does not replace the manufacturer&#39;s conditions with a single observed enclosure-surface temperature.<\/p>\n<p>Record interruptions to the test, including a door opening, load change, room-temperature shift or sensor relocation. Decide from the approved method whether the affected segment remains comparable or must be repeated. Keeping the entire trend makes that decision auditable and avoids silently restarting the time axis at a convenient point.<\/p>\n<p>If the result approaches an applicable limit, investigate the complete design rather than reporting a rounded value that hides the proximity. Check the uncertainty, hottest required location, source variation and representative operating states. A passing result under one favorable condition does not establish the full equipment operating envelope.<\/p>\n<h2 id=\"what-should-an-oem-send-weho-for-a-thermal-discussion\"><span class=\"ez-toc-section\" id=\"What_should_an_OEM_send_WEHO_for_a_thermal_discussion\"><\/span>What should an OEM send WEHO for a thermal discussion?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Send the exact model, input and output conditions, enclosure photographs, local ambient trend, sensor locations and stabilization rule when discussing the <a href=\"https:\/\/www.wehopower.com\/ar\/product\/60w-ac-to-dc-switched-mode-power-supply\/\">LRS-60-12 supply reference<\/a>. Include the applicable limit and raw time history. Ask which product documentation applies to the proposed operating condition before interpreting the result as product acceptance.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"how-many-minutes-should-a-power-supply-warm-up-before-a-thermal-test\"><span class=\"ez-toc-section\" id=\"How_many_minutes_should_a_power_supply_warm_up_before_a_thermal_test\"><\/span>How many minutes should a power supply warm up before a thermal test?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Use the applicable procedure and a defined stabilization criterion. There is no universal time that proves every supply and enclosure has stabilized. The assembly&#39;s thermal behavior, load cycle and measurement purpose determine the required evidence.<\/p>\n<h3 id=\"is-temperature-rise-the-same-as-maximum-operating-temperature\"><span class=\"ez-toc-section\" id=\"Is_temperature_rise_the_same_as_maximum_operating_temperature\"><\/span>Is temperature rise the same as maximum operating temperature?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Temperature rise is a difference between a measured point and a specified reference. Maximum operating temperature is an applicable absolute boundary under stated conditions. Record and assess each quantity for its own purpose.<\/p>\n<h3 id=\"can-i-compare-a-thermal-camera-reading-with-a-contact-probe-result\"><span class=\"ez-toc-section\" id=\"Can_I_compare_a_thermal-camera_reading_with_a_contact-probe_result\"><\/span>Can I compare a thermal-camera reading with a contact-probe result?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Only when the methods, locations and uncertainty support the intended comparison. Different surface properties and sensor effects can produce different results. Validate the measurement approach rather than assuming both displayed temperatures are interchangeable.<\/p>\n<h3 id=\"does-a-stable-enclosure-temperature-prove-internal-components-are-within-limits\"><span class=\"ez-toc-section\" id=\"Does_a_stable_enclosure_temperature_prove_internal_components_are_within_limits\"><\/span>Does a stable enclosure temperature prove internal components are within limits?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. A stable external point does not establish every internal temperature. Use the measurement points and criteria required by the relevant product or equipment evaluation. Avoid inferring an internal hotspot from an unrelated surface reading.<\/p>\n<h3 id=\"can-a-repeating-machine-cycle-have-a-valid-thermal-comparison\"><span class=\"ez-toc-section\" id=\"Can_a_repeating_machine_cycle_have_a_valid_thermal_comparison\"><\/span>Can a repeating machine cycle have a valid thermal comparison?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes. Define a repeatable cyclic condition and compare equivalent phases, peaks or other required quantities under the approved method. A constant temperature is not necessary when the actual acceptance question concerns cyclic operation.<\/p>","protected":false},"excerpt":{"rendered":"<p>Define thermal stabilization before comparing LRS-60-12 cabinet temperatures. Record ambient, load and trend, then send WEHO the actual test conditions.<\/p>","protected":false},"author":2,"featured_media":22062,"parent":0,"menu_order":35,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-22094","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/news\/22094","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/comments?post=22094"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/news\/22094\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/media\/22062"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/media?parent=22094"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ar\/wp-json\/wp\/v2\/news_category?post=22094"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}