LRS Series Enclosed Switching Power Supplies
WEHO LRS series enclosed power supplies convert AC input to a single DC output for control panels, automation equipment and general DC loads. The range includes 35W–600W catalogue classes, multiple output-voltage versions and ventilated enclosures. Input arrangements, cooling and enclosure dimensions vary by model, providing options for different load and installation requirements.
Explore LRS Series Models
Single-output enclosed models for a range of DC loads. LRS-350 is shown first; choose an output voltage and power class to narrow the range.
14 models
No models in this selection
Try another power class or voltage combination, or contact us directly with your exact requirements.
Request selection assistancePower labels are catalogue classes, not a guarantee of identical continuous power at every output voltage. Check the exact output current, ambient conditions and installation requirements in the model datasheet.
Compare LRS Models Before You Specify
Compare electrical options and enclosure sizes in one place. Use the filters above to narrow both the cards and the table.
Open the 14-model comparison table
| মডেল | Power class | AC ইনপুট | DC options | 24V current | 24V efficiency | ঘের | L×W×H | Next step |
|---|---|---|---|---|---|---|---|---|
| LRS-350 | 350W class | 90–132 / 180–264VAC By switch | 12V / 15V / 24V / 48V | 0–14.6A | 88% | With fan | 215×115×30 mm | PDF · উদ্ধৃতি |
| LRS-35 | 35W class | 85–264VAC | 12V / 15V / 24V / 48V | 0–1.5A | 88% | Ventilated metal | 99×82×30 mm | PDF · উদ্ধৃতি |
| LRS-50 | 50W class | 85–264VAC | 12V / 15V / 24V / 48V | 0–2.2A | 88% | Ventilated metal | 99×82×30 mm | PDF · উদ্ধৃতি |
| LRS-60 | 60W class | 85–264VAC | 12V / 15V / 24V / 48V | 0–2.5A | 88% | Ventilated metal | 99×82×30 mm | PDF · উদ্ধৃতি |
| LRS-75 | 75W class | 85–264VAC | 12V / 15V / 24V / 48V | 0–3.2A | 88% | Ventilated metal | 99×97×30 mm | PDF · উদ্ধৃতি |
| LRS-100 | 100W class | 85–264VAC | 12V / 15V / 24V / 48V | 0–4.5A | 88% | Ventilated metal | 129×97×30 mm | PDF · উদ্ধৃতি |
| LRS-120 | 120W class | 85–264VAC | 12V / 15V / 24V / 48V | 0–5A | 88% | Ventilated metal | 129×97×30 mm | PDF · উদ্ধৃতি |
| LRS-150 | 150W class | 85–264VAC | 12V / 15V / 24V / 48V | 0–6.5A | 89% | Ventilated metal | 159×97×30 mm | PDF · উদ্ধৃতি |
| LRS-200 | 200W class | 90–132 / 180–264VAC By switch | 12V / 15V / 24V / 48V | 0–8.8A | 88% | Ventilated metal | 215×115×30 mm | PDF · উদ্ধৃতি |
| LRS-250 | 250W class | 90–132 / 180–264VAC By switch | 12V / 15V / 24V / 48V | 0–10A | 88% | Ventilated metal | 215×115×30 mm | PDF · উদ্ধৃতি |
| LRS-400 | 400W class | 90–132 / 180–264VAC By switch | 12V / 15V / 24V / 48V | 0–16.5A | 88% | With fan | 215×115×30 mm | PDF · উদ্ধৃতি |
| LRS-450 | 450W class | 95–132 / 180–264VAC By switch | 12V / 24V / 36V / 48V | 0–18.7A | 85% | With fan | 215×115×50 mm | PDF · উদ্ধৃতি |
| LRS-500 | 500W class | 95–132 / 180–264VAC By switch | 12V / 24V / 36V / 48V | 0–20A | 86% | With fan | 215×115×50 mm | PDF · উদ্ধৃতি |
| LRS-600 | 600W class | 90–132 / 180–264VAC By switch | 5V / 12V / 15V / 24V / 36V / 48V | 0–25A | 91% | With fan | Confirm drawing revision | PDF · উদ্ধৃতি |
Current ranges and efficiency figures follow each WEHO datasheet. Efficiency test conditions and load derating must be confirmed for your application. Dimensions refer to the stated enclosure body; mounting ears and terminal clearance require a separate drawing check. Confirm the final LRS-450 power rating and LRS-600 enclosure revision with WEHO before ordering.
Need Help Selecting an LRS Power Supply?
Share the exact output voltage and load current, AC input, installation space, operating environment and project quantity. Request a model-specific datasheet and quotation, and let us know if you need mounting, certification or replacement checks.
LRS Series Application Fields
DC control and auxiliary-power selection for compatible industrial equipment.
CNC & Machine Control Cabinets
Use a correctly selected LRS output for compatible DC control electronics and auxiliary loads inside mains-fed machinery. Size motor, spindle and laser power stages separately, including their start-up and transient requirements.
Assembly & Automation Equipment
Compare the DC voltage and current required by controllers, sensors and compatible valves in an automation panel. Check simultaneous loads, switching transients, wiring protection and enclosure ventilation.
Industrial 3D Printing Equipment
Check the combined current and start-up demand of the printer controller, heaters and compatible actuators. Confirm the exact output version and thermal conditions before continuous operation.
Machine Vision & Inspection Systems
Match the supply to the specified input range of cameras, inspection controllers and illumination drivers. Review the model-specific ripple figures and the equipment manufacturer’s filtering and wiring requirements.
Access Control & Security Equipment
Check controller, lock and camera supply requirements separately. Reserve clearance around terminals and the enclosure, and use the exact model drawing rather than a series-wide height assumption.
Warehouse Conveyors & Docking Controls
Consider LRS models for compatible DC controls in stationary, mains-fed warehouse equipment. Battery charging, mobile traction and safety functions need their own approved power architecture.
Application illustrations demonstrate representative operating environments. Confirm exact electrical parameters and mechanical dimensions for your design.
Inside WEHO Smart Manufacturing
Discuss model-specific production, inspection and documentation requirements with WEHO.
SMT Component Placement
Component placement is one stage of the power-supply manufacturing workflow. Ask WEHO about the bill of materials and component requirements for your selected model and order.
Through-Hole Assembly & Soldering
Through-hole components and terminal connections require controlled assembly and inspection. Confirm the relevant workmanship and inspection requirements for your project.
Dispensing & Mechanical Assembly
Assembly processes may include material dispensing and mechanical fixation according to the product design. Confirm any special vibration or environmental qualification requirements separately.
Enclosure & Terminal Assembly
Check the selected enclosure, terminal cover, earthing point and any input selector against the exact product design and installation requirements.
Production Burn-In & Functional Checks
Request the applicable burn-in and functional-test requirements for the selected model and order. Duration, loading and ambient temperature must be confirmed rather than assumed across the series.
Electrical Inspection & Test Records
Request model-specific inspection records and required electrical test conditions. Product isolation ratings, production test voltages and certification scope must be checked separately.
Manufacturing process overview. Contact WEHO for the applicable production and inspection records for your selected model and order.