{"id":19572,"date":"2026-10-19T11:44:44","date_gmt":"2026-10-19T03:44:44","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/led-driver-dimming-compatibility\/"},"modified":"2026-10-19T12:23:39","modified_gmt":"2026-10-19T04:23:39","slug":"led-driver-dimming-compatibility","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/bn\/news\/led-driver-dimming-compatibility\/","title":{"rendered":"LED Driver Dimming Compatibility: Specify the Complete Control Path"},"content":{"rendered":"<div class=\"weho-blog-content\" id=\"weho-article-11\" data-weho-article-id=\"11\">\n<p class=\"direct-answer\">LED driver dimming compatibility depends on the complete controller\u2013interface\u2013driver\u2013LED load path. Match the electrical interface and its capacity, then verify the required minimum light level, off behavior, startup, and transitions using the exact hardware and settings. A shared label such as \u201c0\u201310 V,\u201d \u201cPWM,\u201d or \u201cDALI\u201d is a starting point. It does not define every operating limit or prove that the installed lighting system will behave as specified.<\/p>\n<figure class=\"scene-hero\" id=\"application-scene-11\"><a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/11-scene.png\" target=\"_blank\" rel=\"noopener noreferrer\" aria-label=\"Open full-size illustration\"><picture><source type=\"image\/webp\" srcset=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/11-scene-960.webp?quality=85&#038;strip=all 960w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/11-scene.webp?quality=85&#038;strip=all 1672w\" sizes=\"(max-width:760px) calc(100vw - 36px), 760px\"><img fetchpriority=\"high\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/11-scene.webp?quality=85&#038;strip=all\" width=\"1672\" height=\"941\" alt=\"LED Driver Dimming Compatibility: Specify the Complete Control Path  title=\" loading=\"eager\" decoding=\"async\" led driver dimming compatibility: specify the complete control path title =\"\"><\/picture><\/a><figcaption>AI-assisted dimming-system illustration; not a WEHO laboratory photograph, customer installation or measured compatibility result. The generic controller and luminaires represent review subjects without specifying a control protocol or verified driver pairing.<\/figcaption><\/figure>\n<details class=\"article-toc\" open>\n<summary>\u09b8\u09c2\u099a\u09bf\u09aa\u09a4\u09cd\u09b0<\/summary>\n<nav class=\"toc-links\" aria-label=\"Article sections\"><a href=\"#define-dimming-path\">Draw the actual control path before selecting a driver<\/a><a href=\"#check-interface-current-budget\">Check 0\u201310 V and 1\u201310 V control-current capacity<\/a><a href=\"#specify-minimum-and-off\">Write minimum level and off as separate requirements<\/a><a href=\"#verify-digital-product-identity\">For DALI-2, verify device identity and digital settings<\/a><a href=\"#sample-dimming-acceptance\">Test the intended endpoints and the transitions between them<\/a><a href=\"#request-dimming-documents\">Ask for the control specification with the quotation<\/a><\/nav>\n<\/details>\n<section id=\"define-dimming-path\">\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u09b8\u09c2\u099a\u09bf\u09aa\u09a4\u09cd\u09b0<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u099f\u0997\u09b2 \u0995\u09b0\u09c1\u09a8<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/bn\/news\/led-driver-dimming-compatibility\/#Draw_the_actual_control_path_before_selecting_a_driver\" >Draw the actual control path before selecting a driver<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/bn\/news\/led-driver-dimming-compatibility\/#Check_0%E2%80%9310_V_and_1%E2%80%9310_V_control-current_capacity\" >Check 0\u201310 V and 1\u201310 V control-current capacity<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/bn\/news\/led-driver-dimming-compatibility\/#Write_minimum_level_and_off_as_separate_requirements\" >Write minimum level and off as separate requirements<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/bn\/news\/led-driver-dimming-compatibility\/#For_DALI-2_verify_device_identity_and_digital_settings\" >For DALI-2, verify device identity and digital settings<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/bn\/news\/led-driver-dimming-compatibility\/#Test_the_intended_endpoints_and_the_transitions_between_them\" >Test the intended endpoints and the transitions between them<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/bn\/news\/led-driver-dimming-compatibility\/#Ask_for_the_control_specification_with_the_quotation\" >Ask for the control specification with the quotation<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Draw_the_actual_control_path_before_selecting_a_driver\"><\/span>Draw the actual control path before selecting a driver<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For an OEM luminaire or commercial sign, identify where brightness control happens. A driver may accept a dedicated dimming signal and regulate LED current internally. Alternatively, a downstream controller may switch a constant-voltage bus to compatible modules. A phase-cut dimmer changes the AC waveform entering a driver designed for that method.<\/p>\n<p>These arrangements need different evidence. A small PWM control-input rating says nothing about the current a downstream power controller can switch. A constant-voltage supply with no documented dimming interface is not automatically a phase-cut-dimmable driver.<\/p>\n<details class=\"scene-reference-details concept-reference-disclosure\">\n<summary>Concept overview<\/summary>\n<figure class=\"visual-primer primer-paths\" id=\"visual-primer-11\" aria-labelledby=\"visual-primer-11-label\">\n<div class=\"primer-label\" id=\"visual-primer-11-label\">Power and control have different jobs<\/div>\n<div class=\"primer-track\">\n<strong>Control path<\/strong><\/p>\n<div class=\"primer-flow\">\n<span class=\"primer-item\">Controller<\/span><br \/>\n<span class=\"primer-arrow\" aria-hidden=\"true\">\u2192<\/span><br \/>\n<span class=\"primer-item\">Driver control input<\/span>\n<\/div>\n<\/div>\n<div class=\"primer-track\">\n<strong>Power path<\/strong><\/p>\n<div class=\"primer-flow\">\n<span class=\"primer-item\">Source<\/span><br \/>\n<span class=\"primer-arrow\" aria-hidden=\"true\">\u2192<\/span><br \/>\n<span class=\"primer-item\">Driver<\/span><br \/>\n<span class=\"primer-arrow\" aria-hidden=\"true\">\u2192<\/span><br \/>\n<span class=\"primer-item\">LED load<\/span>\n<\/div>\n<\/div><figcaption class=\"primer-caption\">Conceptual example with a dedicated driver control input. Other control architectures require their own path review; this is not a wiring diagram.<\/figcaption><\/figure>\n<\/details>\n<div class=\"weho-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable comparison table\">\n<table>\n<caption>Specify the interface at the point where it is used<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Control path<\/th>\n<th scope=\"col\">Document before sampling<\/th>\n<th scope=\"col\">System behavior to verify<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Analog controller \u2192 driver dimming input \u2192 LEDs<\/td>\n<td>Source\/sink roles, signal range, control current, isolation, permitted wiring<\/td>\n<td>Minimum level, electronic off or separate switching, endpoint consistency<\/td>\n<\/tr>\n<tr>\n<td>Digital controller \u2192 driver \u2192 LEDs<\/td>\n<td>Protocol, supported device functions, product identity, configuration and bus budget<\/td>\n<td>Addressing, group response, fade settings, power-on and communication-loss behavior<\/td>\n<\/tr>\n<tr>\n<td>Constant-voltage supply \u2192 output PWM controller \u2192 compatible modules<\/td>\n<td>Supply compatibility, controller channel current, switching limits, module approval for pulsed operation<\/td>\n<td>Startup, pulse behavior, acoustic noise, low-level stability<\/td>\n<\/tr>\n<tr>\n<td>Phase-cut control \u2192 compatible AC-input driver \u2192 LEDs<\/td>\n<td>Leading\/trailing-edge support, exact controller pairing, permitted driver count and load range<\/td>\n<td>Low-end stability, switch-on behavior, noise, simultaneous startup<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>First confirm the load&#8217;s <a href=\"https:\/\/www.wehopower.com\/bn\/news\/constant-current-vs-constant-voltage-led-driver-how-to-choose-for-your-project\/\" data-weho-link-kind=\"guide\">constant-current or constant-voltage requirement<\/a>. Dimming compatibility cannot correct an incompatible power-output mode.<\/p>\n<\/section>\n<section id=\"check-interface-current-budget\">\n<h2><span class=\"ez-toc-section\" id=\"Check_0%E2%80%9310_V_and_1%E2%80%9310_V_control-current_capacity\"><\/span>Check 0\u201310 V and 1\u201310 V control-current capacity<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For an analog interface, determine which side supplies control current and which side sinks it. <a href=\"https:\/\/assets.lutron.com\/a\/documents\/048587_web.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">The external application note 587<\/a> explains source\/sink roles, control-current limits, and why minimum level and off behavior can differ. The allowed driver count can be limited by the control circuit even when the AC switching load appears acceptable.<\/p>\n<p>Consider a hypothetical source\/sink system in which each driver sources up to 0.8 mA on its control pair and the selected controller can sink 20 mA per independent output. Assume 32 identical drivers and no additional devices on that control output.<\/p>\n<figure class=\"batch-figure\" id=\"guide-figure-11\"><picture><source media=\"(max-width:640px)\" type=\"image\/webp\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/guide-11-mobile.webp\" width=\"380\" height=\"745\"><source media=\"(max-width:640px)\" type=\"image\/png\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/guide-11-mobile.png\" width=\"380\" height=\"745\"><source type=\"image\/webp\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/guide-11-desktop.webp\"><img loading=\"lazy\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/guide-11-desktop.png?quality=85&#038;strip=all\" width=\"2240\" height=\"1508\" alt=\"LED Driver Dimming Compatibility: Specify the Complete Control Path  title=\" decoding=\"async\" led driver dimming compatibility: specify the complete control path title =\"\"><\/picture><figcaption>Hypothetical source\/sink example: 32 drivers at 0.8 mA each exceed a 20 mA control output. Two independent 16-driver groups draw 12.8 mA per output; verify the complete controller arrangement.<\/figcaption><a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/guide-11-desktop.png\" target=\"_blank\" rel=\"noopener noreferrer\" class=\"relation-detail\">View full diagram<\/a><\/figure>\n<ul class=\"formula-steps\">\n<li>Required sink current: 32 \u00d7 0.8 mA = 25.6 mA<\/li>\n<li>Single control-output rating: 20 mA<\/li>\n<li>Result: 25.6 mA &gt; 20 mA, so one control output is insufficient.<\/li>\n<\/ul>\n<p>Two independently rated outputs with 16 drivers each would see 12.8 mA per output under these assumptions. Check that the controller permits the total connected load and grouping; keep the two outputs independent.<\/p>\n<p>Check the signal voltage at the most demanding driver location using the proposed cable and full control load. Wire resistance and the controller&#8217;s low-end capability can prevent the driver from seeing the intended endpoint. Separately check AC switching current and <a href=\"https:\/\/www.wehopower.com\/bn\/news\/power-supply-inrush-current-multiple-units\/\" data-weho-link-kind=\"guide\">simultaneous driver inrush<\/a>; dividing control groups does not necessarily divide the mains switching event.<\/p>\n<\/section>\n<section id=\"specify-minimum-and-off\">\n<h2><span class=\"ez-toc-section\" id=\"Write_minimum_level_and_off_as_separate_requirements\"><\/span>Write minimum level and off as separate requirements<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>\u201cDims to 1%\u201d needs a defined quantity. It could describe commanded level, output current, or measured light output. Those are not interchangeable, and perceived brightness is another question. State the reference, measurement method, allowed variation, and whether the requirement applies to every fixture or only a sample average.<\/p>\n<p>Traditional 1\u201310 V control can reach the driver&#8217;s minimum light level without switching the LEDs off. Some 0\u201310 V combinations support electronic dim-to-off; the voltage label alone does not establish that function or its threshold. <a href=\"https:\/\/assets.lutron.com\/a\/documents\/048587_web.pdf#page=21\" target=\"_blank\" rel=\"noopener noreferrer\">The referenced relay and electronic-off guidance<\/a> distinguishes minimum-output operation from explicitly supported electronic off. Check the driver and controller together, including the signal they achieve at the end of the installed cable.<\/p>\n<p>When the specified control path stops at minimum output, provide a separately rated mains switch or relay for off. Check its driver count and AC startup duty as well as its continuous rating. Electronic off leaves the driver connected to AC; use the specified physical isolation procedure for maintenance.<\/p>\n<p>For a hypothetical sign project, the engineering team might require a stable nighttime level of 5% of the measured full-output illuminance at a fixed test position, plus no detectable increase over the dark background above an agreed threshold when off. The team should choose those limits from the application, rather than borrow a universal acceptable percentage.<\/p>\n<p>Also specify fade duration, the transition out of off, behavior after power restoration, and any required response if the control cable or communication is lost. Record the intended response before testing so a bright fallback is not accepted simply because the lamps remain on.<\/p>\n<\/section>\n<section id=\"verify-digital-product-identity\">\n<h2><span class=\"ez-toc-section\" id=\"For_DALI-2_verify_device_identity_and_digital_settings\"><\/span>For DALI-2, verify device identity and digital settings<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Where DALI-2 or D4i certification is a project requirement, check the <a href=\"https:\/\/www.dali-alliance.org\/products\" target=\"_blank\" rel=\"noopener noreferrer\">DALI Alliance product database<\/a> against the specific product identity. The database explains that certification is tied to the listed brand, GTIN, and hardware and firmware versions. A similar model name or a generic DALI statement is not equivalent evidence.<\/p>\n<p>Then verify the functions the project actually uses: individual addressing, groups, fade behavior, control type, and configured power-on and communication-loss levels. The lighting layout also needs a documented bus-power and device-capacity budget. Include the controller, gateways, bus power supply, and relevant software versions in the tested configuration.<\/p>\n<p>Component evidence reduces uncertainty, but it does not replace checking the complete LED load and installation. Changing a driver setting or replacing a gateway can change system behavior without changing the fixture&#8217;s outer appearance.<\/p>\n<\/section>\n<section id=\"sample-dimming-acceptance\">\n<h2><span class=\"ez-toc-section\" id=\"Test_the_intended_endpoints_and_the_transitions_between_them\"><\/span>Test the intended endpoints and the transitions between them<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use the exact controller, driver suffix, LED board or module, cable length, driver count, and programmed settings. Test the smallest and largest intended groups where they differ electrically. Repeat the relevant checks at the specified input and temperature extremes and after the system reaches a stable temperature.<\/p>\n<div class=\"weho-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable comparison table\">\n<table>\n<caption>A practical dimming sample record<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Test state<\/th>\n<th scope=\"col\">Record<\/th>\n<th scope=\"col\">Acceptance basis<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Full and minimum output<\/td>\n<td>Command, signal at driver, LED current, light reading and measurement position<\/td>\n<td>Project limits for output and consistency<\/td>\n<\/tr>\n<tr>\n<td>Fade down and fade up<\/td>\n<td>Duration, steps, dropout, delayed pickup, visible instability<\/td>\n<td>Required transition and stable operating range<\/td>\n<\/tr>\n<tr>\n<td>Off and restart<\/td>\n<td>Residual light, flash, delay and restored setting<\/td>\n<td>Defined off threshold and startup behavior<\/td>\n<\/tr>\n<tr>\n<td>Communication loss and recovery<\/td>\n<td>Fallback output and response after restoration<\/td>\n<td>Configured project requirement<\/td>\n<\/tr>\n<tr>\n<td>Relevant camera or occupied-space use<\/td>\n<td>Measurement method, operating levels and observation conditions<\/td>\n<td>Specified temporal-light or camera-performance criterion<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>A phone-camera image can help reproduce a complaint, but camera settings can create or hide banding. Use an appropriate measurement method when a quantitative temporal-light requirement is specified. Keep visible flicker, camera banding, and audible noise as separate observations.<\/p>\n<p>Request a compatibility report for the exact fixture, driver, control device, configuration and test conditions proposed for the project. Treat that report as evidence for its stated combination and conditions, rather than a guarantee for every connected system. Repeat the relevant checks when the combination or configuration changes.<\/p>\n<\/section>\n<section id=\"request-dimming-documents\">\n<h2><span class=\"ez-toc-section\" id=\"Ask_for_the_control_specification_with_the_quotation\"><\/span>Ask for the control specification with the quotation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For the <a href=\"https:\/\/www.wehopower.com\/bn\/product\/ac-dc-12v-24v-36v-48v-led-driver-100w-constant-voltage-waterproof-ip67-switching-power-supply\/\" data-weho-link-kind=\"product_detail\">XLG-100 product reference<\/a> \u09ac\u09be <a href=\"https:\/\/www.wehopower.com\/bn\/product\/hlg-200-200w-12v-24v-36v-48v-waterproof-ip67-led-power-supply-with-pfc\/\" data-weho-link-kind=\"product_detail\">HLG-200 product reference<\/a>, identify whether brightness control is required inside the driver or through a separate controller. Ask whether the exact model and suffix supports the required control interface. Request its interface document, then compare it with the controller specification and intended LED load. These product-identity links do not confirm a dimming function or controller compatibility.<\/p>\n<p class=\"related-model-documents\">The public <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2025\/07\/XLG-100.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" data-weho-link-kind=\"datasheet\">XLG-100 specification<\/a> \u098f\u09ac\u0982 <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2025\/08\/HLG-200.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" data-weho-link-kind=\"datasheet\">HLG-200 specification<\/a> provide electrical-document starting points for those references. They do not establish the required dimming interface or a compatible controller; obtain the exact candidate&#8217;s control-interface documentation separately.<\/p>\n<p>Purchasing should retain the tested bill of materials, configuration file where applicable, interface limits, and acceptance record with the production specification. The broader <a href=\"https:\/\/www.wehopower.com\/bn\/news\/24v-power-supply-manufacturer-oem-rfq-checklist\/\" data-weho-link-kind=\"guide\">OEM power-supply RFQ checklist<\/a> helps carry those technical requirements into comparable quotations and change control.<\/p>\n<p class=\"cta\"><a href=\"https:\/\/www.wehopower.com\/bn\/contact\/\" data-weho-link-kind=\"inquiry\">Contact WEHO about LED dimming compatibility<\/a>. Include the LED load, controller model or proposed control method, and required minimum\/off behavior. Use the sample record to confirm the complete combination before production.<\/p>\n<\/section>\n<p class=\"worksheet-callout\">Optional project record: <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/weho-blog-batch2-2026-10-17-product-v4-11-led-dimming-path-acceptance.csv\" download=\"\" target=\"_blank\" rel=\"noopener noreferrer\" data-weho-link-kind=\"worksheet\">Download the dimming-path acceptance sheet (CSV)<\/a>. Use it to record your own inputs and evidence; example entries are illustrative.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Check LED dimming as a complete controller-to-load path. A source\/sink current example reveals a control-channel overload; the guide distinguishes minimum-output operation, electronic dim-to-off, and physical AC isolation. Sample records cover endpoint consistency, fades, restart, and the exact digital product configuration.<\/p>","protected":false},"author":2,"featured_media":19460,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-19572","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/news\/19572","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/comments?post=19572"}],"version-history":[{"count":1,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/news\/19572\/revisions"}],"predecessor-version":[{"id":19648,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/news\/19572\/revisions\/19648"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/media\/19460"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/media?parent=19572"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/news_category?post=19572"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}