{"id":24303,"date":"2026-11-26T10:08:20","date_gmt":"2026-11-26T02:08:20","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/pid-integral-reset-unit-transfer\/"},"modified":"2026-11-26T10:08:20","modified_gmt":"2026-11-26T02:08:20","slug":"pid-integral-reset-unit-transfer","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/","title":{"rendered":"PID Integral Units: Verify Reset Time Before Transferring Tuning"},"content":{"rendered":"<div class=\"weho-l40-article\" lang=\"en-US\">\n<p>By WEHO<\/p>\n<p>PID integral settings must be transferred with their units and algorithm definition. Reset time and reset rate are reciprocal quantities, so increasing one weakens integral action while increasing the other strengthens it under the corresponding model. Convert the documented meaning first, then verify the receiving loop.<\/p>\n<div class=\"key-takeaways\"><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Preserve time versus rate units.<\/li>\n<li>Check the PID equation as well.<\/li>\n<li>Validate the transferred response.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"L18-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/bn\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\" aria-label=\"TX4-W product details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/tx4-w-production-parameter-lock-application.webp\" width=\"1200\" height=\"675\" alt=\"TX4-W controller mounted in a packaging-machine panel beside process controls and sealing equipment\" loading=\"eager\" decoding=\"async\" title=\"\"><\/a><figcaption>Application illustration; not a customer installation photo. Scene created with AI assistance. TX4-W packaging-panel context. Source display artwork is retained and does not demonstrate integral units, tuning or an accepted loop response. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/33297cd7cf2445108995b6af0573e17ec733e6b5a926dac3a2438e81c03b6805.png\" target=\"_blank\" rel=\"noopener\">View original image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#identify-what-the-tuning-sheet-actually-specifies\">Identify what the tuning sheet actually specifies<\/a><\/li>\n<li><a href=\"#separate-reciprocal-units-from-different-pid-forms\">Separate reciprocal units from different PID forms<\/a><\/li>\n<li><a href=\"#work-a-hypothetical-conversion-and-output-check\">Work a hypothetical conversion and output check<\/a><\/li>\n<li><a href=\"#build-a-controlled-parameter-transfer-sequence\">Build a controlled parameter-transfer sequence<\/a><\/li>\n<li><a href=\"#interpret-discrepancies-beyond-the-i-numeral\">Interpret discrepancies beyond the I numeral<\/a><\/li>\n<li><a href=\"#send-the-unit-definitions-with-the-controller-enquiry\">Send the unit definitions with the controller enquiry<\/a><\/li>\n<li><a href=\"#engineering-faq\">Engineering FAQ<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u09b8\u09c2\u099a\u09bf\u09aa\u09a4\u09cd\u09b0<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u099f\u0997\u09b2 \u0995\u09b0\u09c1\u09a8<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#Identify_what_the_tuning_sheet_actually_specifies\" >Identify what the tuning sheet actually specifies<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#Separate_reciprocal_units_from_different_PID_forms\" >Separate reciprocal units from different PID forms<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#Work_a_hypothetical_conversion_and_output_check\" >Work a hypothetical conversion and output check<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#Build_a_controlled_parameter-transfer_sequence\" >Build a controlled parameter-transfer sequence<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#Interpret_discrepancies_beyond_the_I_numeral\" >Interpret discrepancies beyond the I numeral<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#Send_the_unit_definitions_with_the_controller_enquiry\" >Send the unit definitions with the controller enquiry<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#Engineering_FAQ\" >Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#Does_a_larger_integral_setting_always_mean_stronger_action\" >Does a larger integral setting always mean stronger action?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#What_reset_rate_corresponds_to_120_seconds_per_repeat\" >What reset rate corresponds to 120 seconds per repeat?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#Is_unit_conversion_enough_to_guarantee_equivalent_tuning\" >Is unit conversion enough to guarantee equivalent tuning?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/bn\/news\/pid-integral-reset-unit-transfer\/#Can_a_zero_integral_value_be_inverted\" >Can a zero integral value be inverted?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"identify-what-the-tuning-sheet-actually-specifies\"><span class=\"ez-toc-section\" id=\"Identify_what_the_tuning_sheet_actually_specifies\"><\/span>Identify what the tuning sheet actually specifies<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An OEM replacing a temperature controller may receive a commissioning sheet containing only P, I and D numbers. That sheet is incomplete when the old and new instruments use different time bases or PID forms. A numerically identical I entry can produce a different integral contribution or even move its strength in the wrong direction.<\/p>\n<p>\u09a6 <a href=\"https:\/\/www.wehopower.com\/bn\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\">TX4-W temperature-controller documentation entry<\/a> identifies the intended unit for a configuration enquiry. Confirm the applicable instructions and revision before entering any converted value. The front-panel artwork does not establish the internal equation, the time basis or an accepted tuning result.<\/p>\n<p>The purchasing output should be a parameter-transfer record with original meaning, conversion, receiving meaning and validation. It should preserve the source controller&#39;s identity and the state in which the tuning was accepted. A historical number without the connected sensor, actuator and process condition is a weak starting point for replacement approval.<\/p>\n<h2 id=\"separate-reciprocal-units-from-different-pid-forms\"><span class=\"ez-toc-section\" id=\"Separate_reciprocal_units_from_different_PID_forms\"><\/span>Separate reciprocal units from different PID forms<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For a dependent PI form, write u = Kc \u00d7 (e + integral(e dt)\/Ti), with any bias or limits identified separately. Ti is integral time. For a constant nonzero error and no limiting, the integral contribution grows at Kc \u00d7 e\/Ti. A shorter Ti therefore produces a faster integral ramp within this stated form.<\/p>\n<p>Some instruments describe the reciprocal quantity R = 1\/Ti as reset rate. The <a href=\"https:\/\/www.watlow.com\/-\/media\/documents\/user-manuals\/series-d8-rev-b-november-2008.ashx\" target=\"_blank\" rel=\"noopener\">Watlow D8 user guide<\/a> explicitly contrasts seconds per repeat with repeats per minute. Its conversion discussion also cautions that implementations can differ, so unit conversion alone does not prove equivalent controller behavior.<\/p>\n<p>\u09a6 <a href=\"https:\/\/archive.nptel.ac.in\/content\/storage2\/courses\/103103037\/module4\/lec2\/4.html\" target=\"_blank\" rel=\"noopener\">NPTEL process-control lesson<\/a> explains integral time and its reciprocal reset-rate interpretation. These sources support the distinction, not a universal tuning range or a recommended TX4-W value. Keep any example setting separate from an actual process recommendation.<\/p>\n<p>A parallel PI form, u = Kp \u00d7 e + Ki \u00d7 integral(e dt), uses an integral coefficient Ki. Under compatible scaling, Ki = Kc\/Ti for the dependent form above. Simply applying 1\/Ti is insufficient when the proportional factor or error\/output units differ. Obtain the actual equations and scaling rather than inferring them from the letters on a menu.<\/p>\n<h2 id=\"work-a-hypothetical-conversion-and-output-check\"><span class=\"ez-toc-section\" id=\"Work_a_hypothetical_conversion_and_output_check\"><\/span>Work a hypothetical conversion and output check<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assume an old tuning record specifies Ti = 120 s per repeat. This equals 2.0 min per repeat. Its reciprocal reset rate is R = 1\/2.0 = 0.50 repeats per minute, or 1\/120 = 0.008333 repeats per second. These are equivalent expressions of the stated time quantity.<\/p>\n<p>For an assumed dependent PI implementation, let Kc = 2 output percentage points per \u00b0C and hold e = 3 \u00b0C constant. The immediate proportional contribution is 2 \u00d7 3 = 6 percentage points. The integral ramp is 2 \u00d7 3\/120 = 0.05 percentage points per second, giving another 6 points after 120 s if no limit or other term intervenes.<\/p>\n<p>If someone enters 120 into a receiving reset-rate field expressed in repeats per minute, the implied time becomes 60\/120 = 0.50 s per repeat. That is 240 times faster than the original 120 s value under this ideal comparison. The example illustrates a unit error; it is not permission to run that setting on equipment.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"L18-technical\">\n<p class=\"scroll-help\">Swipe to view the complete diagram, or open full size.<\/p>\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/pid-integral-reset-unit-transfer-example.svg\" width=\"1200\" height=\"675\" alt=\"Hypothetical PID integral conversion linking seconds per repeat, minutes per repeat and reciprocal reset rate\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Equivalent reciprocal-time values for the stated hypothetical PI model; different algorithms or scaling need additional conversion. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/b668a93afd863149c5b3794cbd467858fb36ec6c1485e216419b8aaedcd2337b.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><\/figure>\n<p class=\"scroll-help\">Swipe table horizontally when needed.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Assumed representation<\/th>\n<th scope=\"col\">Equivalent value<\/th>\n<th scope=\"col\">Units<\/th>\n<th scope=\"col\">Required condition<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Integral time<\/td>\n<td>120<\/td>\n<td>s per repeat<\/td>\n<td>Time interpretation confirmed<\/td>\n<\/tr>\n<tr>\n<td>Integral time<\/td>\n<td>2.0<\/td>\n<td>min per repeat<\/td>\n<td>Same definition and scaling<\/td>\n<\/tr>\n<tr>\n<td>Reset rate<\/td>\n<td>0.50<\/td>\n<td>repeats per min<\/td>\n<td>Reciprocal-time definition<\/td>\n<\/tr>\n<tr>\n<td>Parallel coefficient<\/td>\n<td>0.016667<\/td>\n<td>output percentage points\/(\u00b0C\u00b7s)<\/td>\n<td>Kc = 2 points\/\u00b0C in the stated form<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The final row comes from Ki = 2\/120. It is not a dimensionless reset-rate value. Retain enough numerical precision for the receiving field and record any rounding separately. If the instrument accepts only discrete increments, assess the actual accepted setting rather than claiming the entered target was reproduced exactly.<\/p>\n<figure class=\"article-figure product\" data-asset=\"L18-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/bn\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\" aria-label=\"TX4-W product details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/tx4-w-production-parameter-lock-product.webp\" width=\"1000\" height=\"1000\" alt=\"Official TX4-W product reference showing the original housing, visible markings and interface details\" decoding=\"async\" title=\"\"><\/a><figcaption>Official TX4-W product reference. Original visible markings and source clarity are retained; the image is not a measurement or configuration record. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/33297cd7cf2445108995b6af0573e17ec733e6b5a926dac3a2438e81c03b6805.png\" target=\"_blank\" rel=\"noopener\">View original image<\/a><\/figcaption><\/figure>\n<h2 id=\"build-a-controlled-parameter-transfer-sequence\"><span class=\"ez-toc-section\" id=\"Build_a_controlled_parameter-transfer_sequence\"><\/span>Build a controlled parameter-transfer sequence<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li>Preserve the old controller&#39;s complete configuration and source instructions. Record the parameter names, units, algorithm form and input\/output scaling. Verify whether the accepted tuning sheet corresponds to the installed revision and current process.<\/li>\n<li>Obtain the receiving controller&#39;s applicable definition. Record its time base, field limits and special codes. Verify what zero or disabled means; do not apply a reciprocal conversion to a value that represents an instruction rather than a finite time.<\/li>\n<li>Convert each physical quantity explicitly. Record the equation, units and result. Verify the arithmetic independently, keeping the proportional gain or band, integral quantity and derivative quantity as separate fields.<\/li>\n<li>Compare control structure and supporting functions. Record any differences in limiting, manual behavior, filtering or setpoint treatment that the documentation identifies. Verify which differences prevent a claim of mathematical equivalence even after units match.<\/li>\n<li>Evaluate the permitted configuration through the machine&#39;s commissioning procedure. Record setpoint, temperature, output and relevant disturbances. Verify the actual process requirement without changing several unrelated tuning or hardware variables at once.<\/li>\n<li>Release the receiving configuration with its readback and acceptance evidence. Retain the original record and conversion history. Reassess the affected response if the sensor, actuator or thermal operating region changes later.<\/li>\n<\/ol>\n<p>The process team should define output permission, stop conditions and independent protection throughout the evaluation. A theoretical constant-error demonstration is suitable for an appropriate simulation or approved test arrangement; it is not a reason to force a production heater into an unrestricted error condition.<\/p>\n<h2 id=\"interpret-discrepancies-beyond-the-i-numeral\"><span class=\"ez-toc-section\" id=\"Interpret_discrepancies_beyond_the_I_numeral\"><\/span>Interpret discrepancies beyond the I numeral<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>If a converted setting gives a different response, preserve the trace before retuning. The discrepancy may come from a different PID form, error scaling, actuator cycle or process state. A conversion worksheet is intended to expose those differences, not guarantee that they are absent.<\/p>\n<p>Consider an assumed replacement with matching integral time but a proportional gain twice the original value in a dependent form. The integral ramp also doubles for the same constant error because Kc multiplies the integral term. Correctly converting seconds to minutes cannot resolve that separate gain mismatch.<\/p>\n<p>Now consider an implementation with a parallel coefficient and the same displayed I numeral as a dependent controller. The coefficient may carry different units and omit the outside proportional multiplier. Without its equation, the sheet cannot establish equivalence, even if the two instruments both describe their algorithms as PID.<\/p>\n<p>Special values deserve particular attention. A field value of zero may disable integral action, select a mode or have another documented meaning. It cannot be treated as a finite time and inverted. Keep the semantic value in the record and obtain the receiving implementation&#39;s corresponding supported behavior.<\/p>\n<p>A steady final temperature is only one validation result. Review disturbance recovery, overshoot and output behavior under the required operating states. Two configurations can eventually reach setpoint while behaving differently during a short production stage. Preserve the relevant timing and limits with the accepted outcome.<\/p>\n<h2 id=\"send-the-unit-definitions-with-the-controller-enquiry\"><span class=\"ez-toc-section\" id=\"Send_the_unit_definitions_with_the_controller_enquiry\"><\/span>Send the unit definitions with the controller enquiry<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use the <a href=\"https:\/\/www.wehopower.com\/bn\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\">TX4-W configuration reference for enquiries<\/a> to identify the intended instrument. <a href=\"https:\/\/www.wehopower.com\/bn\/contact\/\">Send WEHO the application record<\/a> with the old parameter sheet, its units and equation, the connected sensor and output device, and the required loop behavior. Ask which definitions and settings apply to the ordered revision.<\/p>\n<p>Avoid requesting a replacement that merely accepts the same three numbers. The useful requirement is a documented configuration and an agreed evaluation of the actual process. Keep that installed acceptance separate from the supplier&#39;s confirmation of available parameter fields.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"does-a-larger-integral-setting-always-mean-stronger-action\"><span class=\"ez-toc-section\" id=\"Does_a_larger_integral_setting_always_mean_stronger_action\"><\/span>Does a larger integral setting always mean stronger action?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. A larger integral time reduces the ramp rate in the stated dependent form, while a larger reciprocal reset rate increases it. Identify the physical quantity and implementation first.<\/p>\n<h3 id=\"what-reset-rate-corresponds-to-120-seconds-per-repeat\"><span class=\"ez-toc-section\" id=\"What_reset_rate_corresponds_to_120_seconds_per_repeat\"><\/span>What reset rate corresponds to 120 seconds per repeat?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>It corresponds to 0.50 repeats per minute under the reciprocal-time definition. Confirm that the receiving field uses that definition before entering the value.<\/p>\n<h3 id=\"is-unit-conversion-enough-to-guarantee-equivalent-tuning\"><span class=\"ez-toc-section\" id=\"Is_unit_conversion_enough_to_guarantee_equivalent_tuning\"><\/span>Is unit conversion enough to guarantee equivalent tuning?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. PID form, scaling, limiting, filtering and connected process behavior can differ. Use the conversion as one part of a documented transfer and commissioning assessment.<\/p>\n<h3 id=\"can-a-zero-integral-value-be-inverted\"><span class=\"ez-toc-section\" id=\"Can_a_zero_integral_value_be_inverted\"><\/span>Can a zero integral value be inverted?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Determine its documented meaning first. If it disables integral action or selects a special mode, transfer that behavior through the receiving controller&#39;s supported configuration instead of performing a reciprocal calculation.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Convert integral time and reset rate with explicit units, check the PID equation, then send WEHO the old settings and required loop behavior.<\/p>","protected":false},"author":2,"featured_media":21569,"parent":0,"menu_order":0,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-24303","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/news\/24303","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/comments?post=24303"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/news\/24303\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/media\/21569"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/media?parent=24303"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/bn\/wp-json\/wp\/v2\/news_category?post=24303"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}