{"id":20726,"date":"2026-11-03T10:07:31","date_gmt":"2026-11-03T02:07:31","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/c3z-tof1p-near-range-target-stroke-window\/"},"modified":"2026-11-03T10:07:31","modified_gmt":"2026-11-03T02:07:31","slug":"c3z-tof1p-near-range-target-stroke-window","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/de\/news\/c3z-tof1p-near-range-target-stroke-window\/","title":{"rendered":"C3Z-TOF1P Near-Range Check: Keep the Full Target Stroke Inside the Qualified Window"},"content":{"rendered":"<figure class=\"hero\"><a href=\"https:\/\/www.wehopower.com\/de\/product\/c3z-tof1-series-anti-interference-miniature-photoelectric-switch-sensor\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/hero-1.webp\" alt=\"C3Z-family sensor fixed above a manual linear-stage fixture with a white upright target, visible handwheel and end supports.\" fetchpriority=\"high\" title=\"\"><\/a><figcaption>Conceptual whole-stroke check fixture using the official C3Z-family body: a fixed sensor faces a white target on a supported manual slide. The shared photo does not establish an exact TOF1P exterior or a measured sensing window. AI-assisted illustration.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original.jpeg\">View original product image<\/a><\/figure>\n<p><strong>Check the nearest target position before selecting a long-range photoelectric sensor.<\/strong> The C3Z-TOF1 table begins its adjustable distance range at 50 mm. A target that passes closer than that is outside the listed lower boundary even if its farthest position is comfortably below 1000 mm.<\/p>\n<p>For an OEM mechanical designer locating a sensor around a moving carrier, the decision is whether the entire required detection stroke fits the documented range and a verified application envelope. Maximum distance alone is not enough.<\/p>\n<nav class=\"toc\" aria-label=\"On this page\">\n<ol>\n<li><a href=\"#source-and-suffix\">Use the TOF1 table and record the page conflict<\/a><\/li>\n<li><a href=\"#range-versus-setting\">A threshold is not a guarantee across every closer position<\/a><\/li>\n<li><a href=\"#stroke-budget\">Calculate the nearest and farthest points<\/a><\/li>\n<li><a href=\"#real-target\">Evaluate the real optical path at the endpoints<\/a><\/li>\n<li><a href=\"#release-the-motion\">Validate the required stroke and the change triggers<\/a><\/li>\n<li><a href=\"#photo-evidence\">Do not use a T15 image to illustrate TOF1<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"source-and-suffix\">\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Inhaltsverzeichnis<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Umschalten<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/de\/news\/c3z-tof1p-near-range-target-stroke-window\/#Use_the_TOF1_table_and_record_the_page_conflict\" >Use the TOF1 table and record the page conflict<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/de\/news\/c3z-tof1p-near-range-target-stroke-window\/#A_threshold_is_not_a_guarantee_across_every_closer_position\" >A threshold is not a guarantee across every closer position<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/de\/news\/c3z-tof1p-near-range-target-stroke-window\/#Calculate_the_nearest_and_farthest_points\" >Calculate the nearest and farthest points<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/de\/news\/c3z-tof1p-near-range-target-stroke-window\/#Evaluate_the_real_optical_path_at_the_endpoints\" >Evaluate the real optical path at the endpoints<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/de\/news\/c3z-tof1p-near-range-target-stroke-window\/#Validate_the_required_stroke_and_the_change_triggers\" >Validate the required stroke and the change triggers<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/de\/news\/c3z-tof1p-near-range-target-stroke-window\/#Do_not_use_a_T15_image_to_illustrate_TOF1\" >Do not use a T15 image to illustrate TOF1<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/de\/news\/c3z-tof1p-near-range-target-stroke-window\/#Full-stroke_optical_range_record\" >Full-stroke optical range record<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/de\/news\/c3z-tof1p-near-range-target-stroke-window\/#Sources_and_further_reading\" >Sources and further reading<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Use_the_TOF1_table_and_record_the_page_conflict\"><\/span>Use the TOF1 table and record the page conflict<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Der <a href=\"https:\/\/www.wehopower.com\/de\/product\/c3z-tof1-series-anti-interference-miniature-photoelectric-switch-sensor\/\">C3Z-TOF1 product table<\/a> lists C3Z-TOF1P as PNP, describes diffuse-reflective TOF operation and gives 50\u20131000 mm adjustable distance using 10 \u00d710cm white non-glossy paper. It also lists 12\u201324 VDC supply and 10 ms response. The opening prose incorrectly refers to C3Z-D100, so it must not be read as independent confirmation of a TOF1 specification.<\/p>\n<p>Use the explicit TOF1 table as the initial candidate description and have the applicable current model specification confirmed. Do not extrapolate below 50 mm, assume zero-distance detection or import the capabilities of another TOF product. The stated target condition also does not establish every material, angle or small object.<\/p>\n<\/section>\n<section id=\"range-versus-setting\">\n<h2><span class=\"ez-toc-section\" id=\"A_threshold_is_not_a_guarantee_across_every_closer_position\"><\/span>A threshold is not a guarantee across every closer position<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Distance-settable detection has an applicable sensing region. Reducing a threshold does not automatically make the region extend to the lens surface. The <a href=\"https:\/\/www.ia.omron.com\/support\/guide\/43\/explanation_of_terms.html\" target=\"_blank\" rel=\"noopener\">OMRON photoelectric terminology<\/a> distinguishes set range, sensing range and near dead zone. Those definitions help frame the question but do not supply a measured dead-zone map for C3Z-TOF1P.<\/p>\n<p>Define the position at which the target must be recognized and every position where its absence must be recognized. If detection is needed only at one stopped position, say so. Requiring detection throughout motion is a broader task and needs the complete travel envelope.<\/p>\n<\/section>\n<section id=\"stroke-budget\">\n<h2><span class=\"ez-toc-section\" id=\"Calculate_the_nearest_and_farthest_points\"><\/span>Calculate the nearest and farthest points<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"fig-diagram\" class=\"diagram\"><img decoding=\"async\" class=\"technical-desktop\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-1.svg\" alt=\"Initial target stroke within table endpoints and a revised 44 mm position below the 50 mm lower endpoint\" loading=\"lazy\" title=\"\"><img decoding=\"async\" class=\"technical-mobile\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-mobile-1.svg\" alt=\"Initial target stroke within table endpoints and a revised 44 mm position below the 50 mm lower endpoint\" loading=\"lazy\" title=\"\"><figcaption>Hypothetical stroke envelope and published table endpoints; not a measured C3Z sensing curve.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-1.svg\">Open full-size technical illustration<\/a><\/figure>\n<p>In a hypothetical machine, the target&#8217;s nominal nearest position is 70 mm from the sensing reference, and travel adds up to 140 mm away. Allow\u00b18 mm assembly variation and\u00b16 mm target movement unrelated to the intended stroke. The nearest possible distance is <strong>70\u22128\u22126=56 mm<\/strong>; the farthest is <strong>70+140+8+6=224 mm<\/strong>.<\/p>\n<p>The 56\u2013224 mm geometric envelope lies within the table&#8217;s 50\u20131000 mm endpoints. That is only an initial range screen. If a later fixture change moves the nominal nearest position to 58 mm, the nearest extreme becomes <strong>44 mm<\/strong>, below the 50 mm endpoint. That change needs redesign or new applicable evidence, even though the far end still looks easy.<\/p>\n<\/section>\n<section id=\"real-target\">\n<h2><span class=\"ez-toc-section\" id=\"Evaluate_the_real_optical_path_at_the_endpoints\"><\/span>Evaluate the real optical path at the endpoints<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Include the actual target area seen by the beam at the closest and farthest positions, its angle, surface and background. Do not apply a universal spot size because none has been established here. A lip or hole in a carrier can change the visible return during movement even when the central distance remains within the nominal envelope.<\/p>\n<p>Keep the sensor face reference explicit: measuring to the front of a protective enclosure instead of the actual optical reference can shift the range record. Any protective window must be supported for the arrangement, rather than assumed transparent to the sensing system because it looks clear to a person.<\/p>\n<\/section>\n<section id=\"release-the-motion\">\n<h2><span class=\"ez-toc-section\" id=\"Validate_the_required_stroke_and_the_change_triggers\"><\/span>Validate the required stroke and the change triggers<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Test the real target across the required positions using a defined speed and electrical interface. Record the output and receiving state, including target-absent positions with the real background. Avoid declaring color independence from a short demonstration or a broad marketing sentence. The application record should define the surfaces and geometry actually evaluated.<\/p>\n<p>Changes in carrier height, sensor mounting, protective windows or target finish can alter the qualified window. Preserve the near-distance calculation with the mechanical drawing so the next machine variant does not consume the remaining 6 mm arithmetic difference in the example without review. That 6 mm is not a recommended universal margin.<\/p>\n<\/section>\n<section id=\"photo-evidence\">\n<h2><span class=\"ez-toc-section\" id=\"Do_not_use_a_T15_image_to_illustrate_TOF1\"><\/span>Do not use a T15 image to illustrate TOF1<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The official TOF1 gallery repeats images visibly marked C3Z-T15P-D. They do not establish the TOF1P exterior or a valid installed application. Preserve those source observations in procurement review, but use an accurate TOF1P photograph for its product illustration rather than editing the printed model.<\/p>\n<figure id=\"fig-original\" class=\"product-original\"><a href=\"https:\/\/www.wehopower.com\/de\/product\/c3z-tof1-series-anti-interference-miniature-photoelectric-switch-sensor\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original.jpeg\" alt=\"Official WEHO C3Z-family photograph with its complete coiled factory cable; exact selected model appearance unverified.\" loading=\"lazy\" title=\"\"><\/a><figcaption>Official WEHO C3Z-family reference photograph. This unmarked view does not verify the selected model suffix, optical operating principle or wire functions; the original complete cable and tail are retained.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original.jpeg\">View original image<\/a><\/figure>\n<p class=\"source-list\"><a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2024\/08\/C3Z-Series.jpeg\">Official WEHO family photograph source<\/a><\/p>\n<\/section>\n<section class=\"cta\">\n<p>Send <a href=\"https:\/\/www.wehopower.com\/de\/contact\/\">WEHO<\/a> the C3Z-TOF1P requirement, nearest\/farthest target positions, tolerance stack, target and background samples, speed and receiving input. Request the current exact-model specification and outline to complete the application review.<\/p>\n<\/section>\n<section id=\"worksheet\" class=\"sheet\">\n<h2><span class=\"ez-toc-section\" id=\"Full-stroke_optical_range_record\"><\/span>Full-stroke optical range record<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"sheet-row\"><label>Exact model\/revision<input aria-label=\"Exact model\/revision\"><\/label><label>Reference face<input aria-label=\"Reference face\"><\/label><label>Target\/sample<input aria-label=\"Target\/sample\"><\/label><label>Background<input aria-label=\"Background\"><\/label><label>Required detection positions<input aria-label=\"Required detection positions\"><\/label><\/div>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Initial geometry<\/th>\n<th scope=\"col\">Nearest nominal<\/th>\n<th scope=\"col\">Farthest nominal<\/th>\n<th scope=\"col\">Tolerance contributors<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Bounded envelope<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Nearest extreme<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Farthest extreme<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Source endpoints<\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Optical trial<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Endpoint and transition results<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Output\/input<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Qualified range<\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Change control<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Carrier\/window\/finish change<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">New envelope<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Disposition<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Blank project worksheet. Enter verified project data; example calculations above are not measurements.<\/p>\n<\/section>\n<section class=\"source-list\">\n<h2><span class=\"ez-toc-section\" id=\"Sources_and_further_reading\"><\/span>Sources and further reading<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><a href=\"https:\/\/www.wehopower.com\/de\/product\/c3z-tof1-series-anti-interference-miniature-photoelectric-switch-sensor\/\">WEHO C3Z-TOF1 model table<\/a><\/li>\n<li><a href=\"https:\/\/www.ia.omron.com\/support\/guide\/43\/explanation_of_terms.html\" target=\"_blank\" rel=\"noopener\">OMRON photoelectric range terminology<\/a><\/li>\n<\/ol>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Check the complete C3Z-TOF1P target stroke against the documented sensing window, including its 50 mm near boundary and mechanical tolerances.<\/p>","protected":false},"author":2,"featured_media":20691,"parent":0,"menu_order":173,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-20726","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/20726","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/comments?post=20726"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/20726\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media\/20691"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media?parent=20726"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news_category?post=20726"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}