{"id":21799,"date":"2026-11-12T16:07:07","date_gmt":"2026-11-12T08:07:07","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/proximity-sensors-series-parallel-logic\/"},"modified":"2026-11-12T16:07:07","modified_gmt":"2026-11-12T08:07:07","slug":"proximity-sensors-series-parallel-logic","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/","title":{"rendered":"Inductive Sensors in Series or Parallel: Validate AND\/OR Logic"},"content":{"rendered":"<div class=\"weho-blog\">\n<div class=\"takeaways\">\n<p><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Series or parallel sensor wiring requires permission for the exact output circuit and connected load.<\/li>\n<li>A correct AND\/OR truth table does not establish electrical compatibility.<\/li>\n<li>Include simultaneous operation, loss of one sensor supply and the receiver&#8217;s OFF state in verification.<\/li>\n<li>Separate PLC inputs preserve individual sensor information and allow the required logic to be implemented explicitly.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/de\/product\/lja18-long-cylindrical-inductive-proximity-switch\/\" aria-label=\"LJA18 family details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lja18-family-application-v2.webp\" alt=\"Inductive Sensors in Series or Parallel: Validate AND\/OR Logic  title=\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" inductive sensors in series or parallel: validate><\/a><figcaption>AI-assisted application illustration. Two LJA18 family sensors face separate metal targets and have individual cables. Internal connections and permission to join sensor outputs are not established. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/application-source-5.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#start-with-the-decision-the-machine-must-make\">Start with the decision the machine must make<\/a><\/li>\n<li><a href=\"#separate-the-truth-table-from-the-electrical-circuit\">Separate the truth table from the electrical circuit<\/a><\/li>\n<li><a href=\"#why-output-type-and-model-authorization-come-first\">Why output type and model authorization come first<\/a><\/li>\n<li><a href=\"#use-a-bounded-electrical-example-to-reject-an-unsuitable-proposal\">Use a bounded electrical example to reject an unsuitable proposal<\/a><\/li>\n<li><a href=\"#compare-shared-wiring-with-separate-plc-inputs\">Compare shared wiring with separate PLC inputs<\/a><\/li>\n<li><a href=\"#verify-normal-states-transitions-and-loss-of-power\">Verify normal states, transitions and loss of power<\/a><\/li>\n<li><a href=\"#send-the-logic-requirement-with-the-sensor-enquiry\">Send the logic requirement with the sensor enquiry<\/a><\/li>\n<li><a href=\"#engineering-faq\">Engineering FAQ<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Inhaltsverzeichnis<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Umschalten<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Start_with_the_decision_the_machine_must_make\" >Start with the decision the machine must make<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Separate_the_truth_table_from_the_electrical_circuit\" >Separate the truth table from the electrical circuit<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Why_output_type_and_model_authorization_come_first\" >Why output type and model authorization come first<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Use_a_bounded_electrical_example_to_reject_an_unsuitable_proposal\" >Use a bounded electrical example to reject an unsuitable proposal<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Compare_shared_wiring_with_separate_PLC_inputs\" >Compare shared wiring with separate PLC inputs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Verify_normal_states_transitions_and_loss_of_power\" >Verify normal states, transitions and loss of power<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Send_the_logic_requirement_with_the_sensor_enquiry\" >Send the logic requirement with the sensor enquiry<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Engineering_FAQ\" >Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Can_two_PNP_sensor_outputs_always_be_connected_in_parallel\" >Can two PNP sensor outputs always be connected in parallel?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Does_series_wiring_always_produce_a_dependable_AND_signal\" >Does series wiring always produce a dependable AND signal?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Why_can_the_PLC_remain_ON_after_every_target_is_removed\" >Why can the PLC remain ON after every target is removed?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Do_separate_PLC_inputs_provide_wire-break_detection\" >Do separate PLC inputs provide wire-break detection?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.wehopower.com\/de\/news\/proximity-sensors-series-parallel-logic\/#Can_this_ANDOR_method_be_used_as_a_machine_safety_interlock\" >Can this AND\/OR method be used as a machine safety interlock?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"start-with-the-decision-the-machine-must-make\"><span class=\"ez-toc-section\" id=\"Start_with_the_decision_the_machine_must_make\"><\/span>Start with the decision the machine must make<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Combining two inductive sensor signals can reduce input count, but it also changes fault visibility. Two separate part-present signals become one combined indication. An unexpected output pulse, an unpowered sensor or a leakage path can then affect the shared receiver. Define the machine&#39;s required response before choosing a wiring arrangement.<\/p>\n<p>Der <a href=\"https:\/\/www.wehopower.com\/de\/product\/lja18-long-cylindrical-inductive-proximity-switch\/\">WEHO LJA18 inductive sensor<\/a> product page distinguishes several output variants. Record the complete ordered suffix and its corresponding connection instructions. A family photograph identifies the product range; it does not establish the output circuit inside a received sensor or permission to connect that output to another one.<\/p>\n<figure class=\"article-figure product\" data-asset=\"product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/de\/product\/lja18-long-cylindrical-inductive-proximity-switch\/\" aria-label=\"LJA18 family details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lja18-family-product.webp\" alt=\"Inductive Sensors in Series or Parallel: Validate AND\/OR Logic  title=\" width=\"800\" height=\"800\" decoding=\"async\" inductive sensors in series or parallel: validate><\/a><figcaption>Original photograph of one LJA18 family sensor, showing its threaded housing, sensing face and cable. The exact output variant and permission to connect outputs require separate documentation. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/product-source-4.jpg\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<p>For one sensor connected to one input, the existing <a href=\"https:\/\/www.wehopower.com\/de\/news\/how-to-integrate-inductive-proximity-sensors-with-plc-based-control-systems\/\">proximity sensor and PLC integration article<\/a> covers the basic interface. The additional task here is to approve the behavior of several sensors acting on one logical result, including conditions that ordinary target detection does not reveal.<\/p>\n<h2 id=\"separate-the-truth-table-from-the-electrical-circuit\"><span class=\"ez-toc-section\" id=\"Separate_the_truth_table_from_the_electrical_circuit\"><\/span>Separate the truth table from the electrical circuit<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>AND and OR describe logical relationships. For positive detection logic, AND is true when both required conditions are present; OR is true when either condition is present. A normally closed output changes the relationship between the physical target and the electrical input, so write down which state each variable represents.<\/p>\n<p>This hypothetical process example uses two independent target-present variables, A and B. The required indication is \u201cat least one lane contains a component.\u201d The table defines the intended software result before any output wires are connected.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/sensor-independent-input-logic.svg\" alt=\"Inductive Sensors in Series or Parallel: Validate AND\/OR Logic  title=\" width=\"1200\" height=\"900\" decoding=\"async\" inductive sensors in series or parallel: validate><\/div><figcaption>Conceptual Engineering Diagram. Conceptual process logic with separate controller inputs. The OR truth table does not authorize connecting sensor outputs together. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/sensor-independent-input-logic.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Target A<\/th>\n<th scope=\"col\">Target B<\/th>\n<th scope=\"col\">Required OR<\/th>\n<th scope=\"col\">Required AND<\/th>\n<th scope=\"col\">Record to retain<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Absent: 0<\/td>\n<td>Absent: 0<\/td>\n<td>0<\/td>\n<td>0<\/td>\n<td>Receiver returns to its defined OFF state<\/td>\n<\/tr>\n<tr>\n<td>Present: 1<\/td>\n<td>Absent: 0<\/td>\n<td>1<\/td>\n<td>0<\/td>\n<td>A acts without depending on B<\/td>\n<\/tr>\n<tr>\n<td>Absent: 0<\/td>\n<td>Present: 1<\/td>\n<td>1<\/td>\n<td>0<\/td>\n<td>B acts without depending on A<\/td>\n<\/tr>\n<tr>\n<td>Present: 1<\/td>\n<td>Present: 1<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>Simultaneous operation and subsequent release<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>A result that works in these four normal states can still fail during transitions. Include A releasing while B remains active and the reverse order. Record whether the receiver briefly changes state, how long that change lasts and whether downstream filtering or program execution accepts it. Define the allowed behavior from the process requirement, rather than hiding an unexplained pulse with an arbitrary delay.<\/p>\n<h2 id=\"why-output-type-and-model-authorization-come-first\"><span class=\"ez-toc-section\" id=\"Why_output_type_and_model_authorization_come_first\"><\/span>Why output type and model authorization come first<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An output transistor is an electronic interface, not an isolated relay contact. Its behavior when active, inactive and unpowered depends on its circuit. An NPN or PNP label alone does not specify reverse-current tolerance, interaction with another output or the operating conditions of a cascaded sensor.<\/p>\n<p><a href=\"https:\/\/www.ia.omron.com\/support\/faq\/answer\/41\/faq00311\/index.html\" target=\"_blank\" rel=\"noopener\">OMRON&#39;s series\/parallel connection FAQ<\/a> treats DC two-wire, AC two-wire and DC three-wire arrangements separately. Some stated cases require relay interfaces, and the FAQ identifies possible startup pulses and reset problems. Those product-specific examples demonstrate why a universal connection rule is unsuitable; their permitted sensor counts are not specifications for WEHO products.<\/p>\n<p>For a proposed hardwired arrangement, obtain the exact sensor instructions and receiver data together. Request the permitted topology, number of devices, load range, residual voltage, leakage current and power-sequencing behavior. Where the documentation does not authorize the intended combination, retain separate inputs or seek a documented interface solution before release.<\/p>\n<h2 id=\"use-a-bounded-electrical-example-to-reject-an-unsuitable-proposal\"><span class=\"ez-toc-section\" id=\"Use_a_bounded_electrical_example_to_reject_an_unsuitable_proposal\"><\/span>Use a bounded electrical example to reject an unsuitable proposal<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A voltage budget can reject a proposed series arrangement even when its logical AND behavior looks correct. The following numbers are hypothetical and apply only to an assumed, manufacturer-authorized topology. They are not LJA18 ratings or instructions to connect sensors in series.<\/p>\n<p>Assume the available supply minimum is 21.6 V, three series devices each have a maximum 1.5 V residual drop under the relevant load, and the receiver requires at least 18.0 V to guarantee ON. First calculate the device drops:<\/p>\n<p>Total residual drop = 3 \u00d7 1.5 V = 4.5 V.<\/p>\n<p>Available receiver voltage = 21.6 V \u2212 4.5 V = 17.1 V.<\/p>\n<p>The proposal misses the assumed ON requirement by 0.9 V, even before cable and contact losses are included. Reject that electrical budget. Increasing the nominal supply is not an automatic remedy: every connected device&#39;s permitted voltage and the complete operating range would need another review.<\/p>\n<p>For a parallel arrangement, make a separate OFF-state budget using documented leakage paths and the receiver&#39;s guaranteed OFF limits. Do not assume that one successful ON measurement also proves reliable release. Added interfaces, indicator circuits and unpowered devices may introduce paths that a simple sum of sensor leakage does not represent.<\/p>\n<h2 id=\"compare-shared-wiring-with-separate-plc-inputs\"><span class=\"ez-toc-section\" id=\"Compare_shared_wiring_with_separate_PLC_inputs\"><\/span>Compare shared wiring with separate PLC inputs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Separate inputs provide distinct observations of A and B. Software can calculate OR for the process while retaining the individual states for diagnostics. That architecture still needs compatible sensor\/input circuits, correct references and suitable timing. It does not turn ordinary sensors or a standard PLC into a safety system.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Review point<\/th>\n<th scope=\"col\">Shared AND\/OR wiring<\/th>\n<th scope=\"col\">Separate PLC inputs<\/th>\n<th scope=\"col\">Decision evidence<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Electrical permission<\/td>\n<td>Exact combination must be authorized<\/td>\n<td>Each sensor\/input interface must match<\/td>\n<td>Model instructions and receiver specification<\/td>\n<\/tr>\n<tr>\n<td>Simultaneous targets<\/td>\n<td>Possible interaction at the shared node<\/td>\n<td>Two individually observable states<\/td>\n<td>Both-active and release-order records<\/td>\n<\/tr>\n<tr>\n<td>One sensor loses supply<\/td>\n<td>May affect the combined signal<\/td>\n<td>May appear as a normal state unless diagnostics exist<\/td>\n<td>Defined power-loss response<\/td>\n<\/tr>\n<tr>\n<td>Fault localization<\/td>\n<td>Combined indication can conceal the source<\/td>\n<td>Individual states support diagnosis<\/td>\n<td>Service requirements and fault table<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The process owner should decide whether losing individual information is acceptable. For example, a combined OR cannot distinguish \u201cA present\u201d from \u201cB present\u201d at its single receiver. If maintenance needs that distinction, saving one input may create an avoidable troubleshooting burden. Document that tradeoff as part of the machine specification.<\/p>\n<h2 id=\"verify-normal-states-transitions-and-loss-of-power\"><span class=\"ez-toc-section\" id=\"Verify_normal_states_transitions_and_loss_of_power\"><\/span>Verify normal states, transitions and loss of power<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use a controlled commissioning plan with machine motion or hazardous process energy prevented as required by the equipment design. Verification should observe the electrical receiver and the resulting program state together. A sensor indicator alone cannot show what a PLC sampled.<\/p>\n<ol>\n<li><strong>Identify the components.<\/strong> Record complete sensor suffixes, receiver channel type, supply arrangement and instruction revisions. Verify that each received component matches the reviewed interface; inspect the actual <a href=\"https:\/\/www.wehopower.com\/de\/product\/lja18-long-cylindrical-inductive-proximity-switch\/\">LJA18 sensor model options<\/a> when preparing the order record.<\/li>\n<li><strong>Approve the connection proposal.<\/strong> Retain the supplier&#39;s permitted topology and load conditions, or select individually matched inputs. Verify voltage and current budgets against guaranteed limits rather than typical values.<\/li>\n<li><strong>Exercise the four normal states.<\/strong> Record receiver voltage\/current as appropriate and the interpreted logic. Verify every row of the agreed truth table, including the both-active condition.<\/li>\n<li><strong>Exercise transitions and power states.<\/strong> Record target release order, startup, shutdown and loss\/restoration of each relevant supply. Verify pulse durations and final states against the process requirement and actual receiver timing.<\/li>\n<li><strong>Close the exceptions.<\/strong> Record unexplained states, changed filters and revised components. Repeat the affected cases after correction and retain the final schematic, program revision and results together.<\/li>\n<\/ol>\n<p>An acceptable result is a repeatable, documented combination under the stated conditions. Changing a sensor suffix, input module, common reference or interface can change the behavior, even if the replacement has the same nominal sensing range. Review the affected cases before releasing a substitution.<\/p>\n<h2 id=\"send-the-logic-requirement-with-the-sensor-enquiry\"><span class=\"ez-toc-section\" id=\"Send_the_logic_requirement_with_the_sensor_enquiry\"><\/span>Send the logic requirement with the sensor enquiry<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Ask WEHO to confirm the exact output variant and available connection instructions for the proposed process interface. Include the receiver specification, supply limits, AND\/OR truth table, simultaneous-target conditions and required power-loss response. State whether independent PLC inputs are available so the enquiry can address a documented arrangement rather than an assumed shared-output connection.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"can-two-pnp-sensor-outputs-always-be-connected-in-parallel\"><span class=\"ez-toc-section\" id=\"Can_two_PNP_sensor_outputs_always_be_connected_in_parallel\"><\/span>Can two PNP sensor outputs always be connected in parallel?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No universal permission follows from the PNP label. Confirm the exact output circuit, allowed parallel arrangement, receiver and unpowered behavior in the applicable product instructions. Matching nominal supply voltage does not establish those conditions.<\/p>\n<h3 id=\"does-series-wiring-always-produce-a-dependable-and-signal\"><span class=\"ez-toc-section\" id=\"Does_series_wiring_always_produce_a_dependable_AND_signal\"><\/span>Does series wiring always produce a dependable AND signal?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No, electrical limits and power-up behavior can invalidate the intended logic. A downstream sensor may depend on another device&#39;s state, while cumulative voltage loss can prevent the receiver from reaching its guaranteed ON region. Use only an authorized arrangement and verify transitions.<\/p>\n<h3 id=\"why-can-the-plc-remain-on-after-every-target-is-removed\"><span class=\"ez-toc-section\" id=\"Why_can_the_PLC_remain_ON_after_every_target_is_removed\"><\/span>Why can the PLC remain ON after every target is removed?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The combined interface may not meet the receiver&#39;s OFF requirements. Evaluate documented leakage, added indicator paths, receiver thresholds and any active device holding the shared node. Compare measurements at the receiver with the full circuit, rather than judging only from sensor LEDs.<\/p>\n<h3 id=\"do-separate-plc-inputs-provide-wire-break-detection\"><span class=\"ez-toc-section\" id=\"Do_separate_PLC_inputs_provide_wire-break_detection\"><\/span>Do separate PLC inputs provide wire-break detection?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Separate inputs alone do not establish wire-break detection. A broken wire can produce the same input state as a normal process condition. Diagnostic coverage requires an appropriate interface, logic and fault-response specification; retain that distinction in the acceptance record.<\/p>\n<h3 id=\"can-this-and-or-method-be-used-as-a-machine-safety-interlock\"><span class=\"ez-toc-section\" id=\"Can_this_ANDOR_method_be_used_as_a_machine_safety_interlock\"><\/span>Can this AND\/OR method be used as a machine safety interlock?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A normal process truth table does not establish a safety function. A safety-related application needs its own risk assessment, suitable components and validation of the complete function. The examples here address process signaling and do not assign a safety rating to LJA18 sensors or PLC logic.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Check series or parallel sensor logic, receiver limits and power-loss states. Send WEHO the exact output variant and AND\/OR requirement for review.<\/p>","protected":false},"author":2,"featured_media":21777,"parent":0,"menu_order":62,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-21799","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/21799","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/comments?post=21799"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/21799\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media\/21777"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media?parent=21799"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news_category?post=21799"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}