{"id":22091,"date":"2026-11-15T18:07:42","date_gmt":"2026-11-15T10:07:42","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/pulsed-dc-load-rms-current-heating\/"},"modified":"2026-11-15T18:09:24","modified_gmt":"2026-11-15T10:09:24","slug":"pulsed-dc-load-rms-current-heating","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/","title":{"rendered":"Pulsed DC Load Heating: Separate RMS Current from Average Demand"},"content":{"rendered":"<p><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Average current supports an energy calculation at a fixed voltage.<\/li>\n<li>RMS current supports a resistive-heating calculation for the defined waveform.<\/li>\n<li>Check the instantaneous load voltage and supply requirements separately.<\/li>\n<li>Keep duty-cycle examples distinct from a product&#39;s documented overload capability.<\/li>\n<\/ul>\n<figure data-role=\"hero\"><a href=\"https:\/\/www.wehopower.com\/product\/lrs-series-35w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"View LRS-35-24 product details\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-35-24-application.avif\" width=\"1200\" height=\"675\" alt=\"Pulsed DC Load Heating: Separate RMS Current from Average Demand  title=\" data-image-role=\"hero\" loading=\"eager\" fetchpriority=\"high\" Pulsed DC Load Heating: Separate RMS Current from Average Demand title=\"\"><\/a><figcaption>Application illustration; not a customer installation or test. The AI-assisted scene retains original LRS-35-24 product artwork. This cabinet context does not portray the article&#8217;s hypothetical measurements or constitute installation approval. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-hero-v2-1.png\">View source image<\/a><\/figcaption><\/figure>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#Why_can_average_current_understate_harness_heating\" >Why can average current understate harness heating?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#How_do_you_calculate_average_and_RMS_current\" >How do you calculate average and RMS current?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#Standard_Engineering_Sizing_Example\" >Standard Engineering Sizing Example<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#Which_quantities_belong_in_the_load-cycle_matrix\" >Which quantities belong in the load-cycle matrix?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#How_should_an_OEM_validate_a_repeating_DC_load\" >How should an OEM validate a repeating DC load?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#What_does_RMS_current_leave_unresolved\" >What does RMS current leave unresolved?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#What_should_an_OEM_send_WEHO_for_a_pulsed-load_review\" >What should an OEM send WEHO for a pulsed-load review?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#Engineering_FAQ\" >Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#Can_average_current_be_used_to_calculate_cable_heating\" >Can average current be used to calculate cable heating?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#Does_RMS_current_determine_the_required_supply_output_rating\" >Does RMS current determine the required supply output rating?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#Are_the_examples_currents_measured_LRS-35-24_performance\" >Are the example&#39;s currents measured LRS-35-24 performance?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#Can_two_pulses_with_the_same_duty_cycle_have_different_thermal_behavior\" >Can two pulses with the same duty cycle have different thermal behavior?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.wehopower.com\/de\/news\/pulsed-dc-load-rms-current-heating\/#Does_a_low_calculated_harness_loss_prove_that_the_contact_is_good\" >Does a low calculated harness loss prove that the contact is good?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"why-can-average-current-understate-harness-heating\"><span class=\"ez-toc-section\" id=\"Why_can_average_current_understate_harness_heating\"><\/span>Why can average current understate harness heating?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For a changing current, average resistive heating depends on the average of current squared. Squaring the average current can produce a lower result and miss the effect of repeated pulses. The engineering task is to assess the harness under the actual operating cycle while also checking the supply&#39;s instantaneous load requirements.<\/p>\n<p>The <a href=\"https:\/\/www.wehopower.com\/product\/lrs-series-35w-ac-to-dc-single-output-switching-power-supply\/\">LRS-35-24 supply product reference<\/a> provides an enclosed 24 V candidate for this example. The numerical waveform below is hypothetical. It does not describe a measured LRS-35 output or grant an undocumented repetitive overload allowance.<\/p>\n<p>A small industrial controller may alternate between an idle state and a brief actuator-on state. The purchasing record should retain both states and their timing. A single average-current number can be useful, but it cannot replace every electrical and thermal check.<\/p>\n<nav aria-label=\"Article contents\">\n<details>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#why-can-average-current-understate-harness-heating\">Why can average current understate harness heating?<\/a><\/li>\n<li><a href=\"#how-do-you-calculate-average-and-rms-current\">How do you calculate average and RMS current?<\/a><\/li>\n<li><a href=\"#which-quantities-belong-in-the-load-cycle-matrix\">Which quantities belong in the load-cycle matrix?<\/a><\/li>\n<li><a href=\"#how-should-an-oem-validate-a-repeating-dc-load\">How should an OEM validate a repeating DC load?<\/a><\/li>\n<li><a href=\"#what-does-rms-current-leave-unresolved\">What does RMS current leave unresolved?<\/a><\/li>\n<li><a href=\"#what-should-an-oem-send-weho-for-a-pulsed-load-review\">What should an OEM send WEHO for a pulsed-load review?<\/a><\/li>\n<li><a href=\"#engineering-faq\">Engineering FAQ<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<h2 id=\"how-do-you-calculate-average-and-rms-current\"><span class=\"ez-toc-section\" id=\"How_do_you_calculate_average_and_RMS_current\"><\/span>How do you calculate average and RMS current?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For a two-state waveform, average current is I<sub>avg<\/sub> = dI<sub>on<\/sub> + (1 \u2212 d)I<sub>off<\/sub>, where d is the fraction of the complete cycle spent in the ON state. RMS current is I<sub>rms<\/sub> = \u221a[dI<sub>on<\/sub>\u00b2 + (1 \u2212 d)I<sub>off<\/sub>\u00b2]. Both formulas require the actual defined cycle.<\/p>\n<h3 id=\"standard-engineering-sizing-example\"><span class=\"ez-toc-section\" id=\"Standard_Engineering_Sizing_Example\"><\/span>Standard Engineering Sizing Example<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Assume a hypothetical 24 V load draws 1.00 A for 25% of each cycle and 0.25 A for the remaining 75%. Assume the current is constant within each state, the waveform repeats, and the defined harness segment has a constant resistance of 0.20 \u03a9. These are calculation inputs, not manufacturer limits.<\/p>\n<p>Average current is 0.25 \u00d7 1.00 + 0.75 \u00d7 0.25 = 0.4375 A. At an assumed constant 24 V load voltage, average load power is 24 \u00d7 0.4375 = 10.5 W. This power result describes energy demand within the stated approximation.<\/p>\n<p>RMS current is \u221a(0.25 \u00d7 1.00\u00b2 + 0.75 \u00d7 0.25\u00b2) = \u221a0.296875 = approximately 0.5449 A. Average resistive loss in the defined segment is I<sub>rms<\/sub>\u00b2R = 0.296875 \u00d7 0.20 = 0.059375 W, approximately 0.0594 W.<\/p>\n<figure data-role=\"technical\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-35-24-engineering-example.svg\" width=\"1200\" height=\"675\" alt=\"Pulsed DC Load Heating: Separate RMS Current from Average Demand  title=\" data-image-role=\"technical\" loading=\"lazy\" Pulsed DC Load Heating: Separate RMS Current from Average Demand title=\"\"><figcaption>Conceptual Engineering Diagram. The two-state waveform, 0.20 \u03a9 resistance and all calculated values are hypothetical, not product measurements or manufacturer limits. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-35-24-engineering-example.svg\">View source image<\/a><\/figcaption><\/figure>\n<p>Squaring the average instead gives 0.4375\u00b2 \u00d7 0.20 = approximately 0.0383 W. That is lower than the correct result for the assumed waveform. The difference occurs because the high-current part of the cycle contributes disproportionately to I\u00b2R heating.<\/p>\n<p>The two state-specific losses provide a cross-check. At 1.00 A the segment dissipates 0.200 W; at 0.25 A it dissipates 0.0125 W. Weighting those losses by their cycle fractions gives 0.25 \u00d7 0.200 + 0.75 \u00d7 0.0125 = 0.059375 W, matching the RMS calculation.<\/p>\n<h2 id=\"which-quantities-belong-in-the-load-cycle-matrix\"><span class=\"ez-toc-section\" id=\"Which_quantities_belong_in_the_load-cycle_matrix\"><\/span>Which quantities belong in the load-cycle matrix?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Keep peak or state current, average current and RMS current as different fields. The appropriate quantity depends on the decision. A current waveform with the same average as another waveform can have different resistive heating, instantaneous voltage drop and source requirements.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th>Quantity<\/th>\n<th>Hypothetical result<\/th>\n<th>Useful decision<\/th>\n<th>Does not prove<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>High-state current<\/td>\n<td>1.00 A<\/td>\n<td>Instantaneous demand and drop<\/td>\n<td>Repetitive overload permission<\/td>\n<\/tr>\n<tr>\n<td>Average current<\/td>\n<td>0.4375 A<\/td>\n<td>Average energy at fixed voltage<\/td>\n<td>Resistive heating by itself<\/td>\n<\/tr>\n<tr>\n<td>RMS current<\/td>\n<td>0.5449 A<\/td>\n<td>Average I\u00b2R loss<\/td>\n<td>Contact temperature or source transient response<\/td>\n<\/tr>\n<tr>\n<td>Segment loss<\/td>\n<td>0.0594 W<\/td>\n<td>Defined segment&#8217;s heat input<\/td>\n<td>Complete harness qualification<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The instantaneous drop across the assumed segment is 1.00 A \u00d7 0.20 \u03a9 = 0.20 V during the high state, and 0.25 A \u00d7 0.20 \u03a9 = 0.05 V during idle. A load with a narrow operating window might care about the 0.20 V event even when the average power is modest.<\/p>\n<p>Do not derive a component temperature directly from the calculated loss. Temperature depends on geometry, material, contacts, neighboring loads, enclosure conditions and time behavior. Use the applicable component evidence and the representative assembled thermal evaluation for the actual acceptance decision.<\/p>\n<h2 id=\"how-should-an-oem-validate-a-repeating-dc-load\"><span class=\"ez-toc-section\" id=\"How_should_an_OEM_validate_a_repeating_DC_load\"><\/span>How should an OEM validate a repeating DC load?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Record current and voltage with enough time resolution to capture the required cycle. A slow averaging meter can hide short peaks or transitions. The necessary instrument bandwidth, capture window and measurement method depend on the actual event and decision.<\/p>\n<ol>\n<li>Identify every relevant state, its duration and the conditions that can change the sequence. Include maintenance or software modes that alter repetition.<\/li>\n<li>Record current through the defined harness segment and voltage at the load. Keep measurement points and instrument settings with the waveform.<\/li>\n<li>Calculate average current, RMS current and state-specific drop using the captured or justified waveform. Include all states over the complete period.<\/li>\n<li>Compare source demand, conductor\/contact requirements and load voltage with their own applicable limits. Do not substitute one calculation for the other checks.<\/li>\n<li>Verify the representative assembled condition and record the acceptance method. Reassess after a load, harness, component or cycle change.<\/li>\n<\/ol>\n<p>If the waveform contains a short charging or switching transient, include it where it contributes to the required quantity. A two-level approximation that omits that event may not represent the actual cycle. Report the approximation and its limits rather than silently calling a simplified trace a measurement.<\/p>\n<p>Changes to energized conductors and access to mains terminals require qualified personnel and the applicable isolation procedure. Current measurement can also introduce burden or alter a connection event. Use a suitable method for the system rather than inserting a meter without assessing the effect.<\/p>\n<h2 id=\"what-does-rms-current-leave-unresolved\"><span class=\"ez-toc-section\" id=\"What_does_RMS_current_leave_unresolved\"><\/span>What does RMS current leave unresolved?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>RMS current is not a blanket power-supply selection rule. A source can have adequate average output capacity while failing an instantaneous load, startup or protection requirement. The <a href=\"https:\/\/www.wehopower.com\/product\/lrs-series-35w-ac-to-dc-single-output-switching-power-supply\/\">LRS-35-24 operating documentation<\/a> must still support the required load under its applicable input, temperature and installation conditions.<\/p>\n<figure data-role=\"product\"><a href=\"https:\/\/www.wehopower.com\/product\/lrs-series-35w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"View LRS-35-24 product details\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-35-24-product-reference.avif\" width=\"1000\" height=\"1000\" alt=\"Pulsed DC Load Heating: Separate RMS Current from Average Demand  title=\" data-image-role=\"product\" loading=\"lazy\" Pulsed DC Load Heating: Separate RMS Current from Average Demand title=\"\"><\/a><figcaption>Official LRS-35-24 product photograph retained as an identity reference. Numerical examples in this article are hypothetical and are not product test results. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-lrs-35-source.jpg\">View source image<\/a><\/figcaption><\/figure>\n<p>A resistive-loss calculation also does not establish suppression behavior for an inductive actuator. Turn-off voltage, release time and the destination of stored energy require their own circuit review. Keeping those questions separate prevents an acceptable RMS result from being interpreted as complete actuator compatibility.<\/p>\n<p>Repetition rate matters when determining temperature cycling and response. Two cycles can have the same duty fraction and RMS current but different on-time duration. Their long-term average resistive heat may match under the model, while their temperature excursions and load behavior differ.<\/p>\n<p>Retain the source of the resistance value. It should correspond to the segment actually being evaluated, including relevant conductors and contacts. If resistance changes materially with temperature, a constant-resistance calculation is only an approximation and should be refined or supported by representative measurements.<\/p>\n<h2 id=\"what-should-an-oem-send-weho-for-a-pulsed-load-review\"><span class=\"ez-toc-section\" id=\"What_should_an_OEM_send_WEHO_for_a_pulsed-load_review\"><\/span>What should an OEM send WEHO for a pulsed-load review?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Send the required 24 V operating window, high and idle currents, state durations, repetition rate, startup behavior and operating environment when discussing the <a href=\"https:\/\/www.wehopower.com\/product\/lrs-series-35w-ac-to-dc-single-output-switching-power-supply\/\">LRS-35-24 supply candidate<\/a>. Include the load-terminal waveform and relevant harness details. Ask for applicable product documentation before approving the assembly.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"can-average-current-be-used-to-calculate-cable-heating\"><span class=\"ez-toc-section\" id=\"Can_average_current_be_used_to_calculate_cable_heating\"><\/span>Can average current be used to calculate cable heating?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>For a changing current, use the average of I\u00b2R or the corresponding RMS current when resistance is treated as constant. Squaring average current can understate loss. A steady current is the special case where average and RMS values coincide.<\/p>\n<h3 id=\"does-rms-current-determine-the-required-supply-output-rating\"><span class=\"ez-toc-section\" id=\"Does_RMS_current_determine_the_required_supply_output_rating\"><\/span>Does RMS current determine the required supply output rating?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Not by itself. Check the instantaneous current, duration, startup and allowed operating conditions as well as average demand. RMS is useful for a defined resistive-heating question, not a substitute for the source&#39;s documented load envelope.<\/p>\n<h3 id=\"are-the-example-39-s-currents-measured-lrs-35-24-performance\"><span class=\"ez-toc-section\" id=\"Are_the_examples_currents_measured_LRS-35-24_performance\"><\/span>Are the example&#39;s currents measured LRS-35-24 performance?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. They are hypothetical load states used to demonstrate the calculation. The article does not report a product test, define a repetitive overload rating or establish a particular actuator&#39;s compatibility.<\/p>\n<h3 id=\"can-two-pulses-with-the-same-duty-cycle-have-different-thermal-behavior\"><span class=\"ez-toc-section\" id=\"Can_two_pulses_with_the_same_duty_cycle_have_different_thermal_behavior\"><\/span>Can two pulses with the same duty cycle have different thermal behavior?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes. Their average resistive loss may match in a simplified model, while pulse duration and repetition affect temperature excursions and time response. Evaluate the quantities required by the actual component and equipment limits.<\/p>\n<h3 id=\"does-a-low-calculated-harness-loss-prove-that-the-contact-is-good\"><span class=\"ez-toc-section\" id=\"Does_a_low_calculated_harness_loss_prove_that_the_contact_is_good\"><\/span>Does a low calculated harness loss prove that the contact is good?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. A calculation depends on its resistance assumption and boundary. A damaged or poorly terminated contact can behave differently. Check the representative assembly, applicable component requirements and measured results before accepting the connection.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Calculate average and RMS current for a pulsed LRS-35-24 load example. Check instantaneous voltage and harness heating before sending WEHO your duty cycle.<\/p>","protected":false},"author":2,"featured_media":22047,"parent":0,"menu_order":32,"comment_status":"closed","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-22091","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/22091","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/comments?post=22091"}],"version-history":[{"count":1,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/22091\/revisions"}],"predecessor-version":[{"id":22101,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/22091\/revisions\/22101"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media\/22047"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media?parent=22091"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news_category?post=22091"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}