{"id":23423,"date":"2026-11-21T10:15:57","date_gmt":"2026-11-21T02:15:57","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/ssr-pulse-analogue-interface-check\/"},"modified":"2026-11-21T10:15:57","modified_gmt":"2026-11-21T02:15:57","slug":"ssr-pulse-analogue-interface-check","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/","title":{"rendered":"SSR Drive Pulses and 0\u201310 V Signals: Verify the Interface"},"content":{"rendered":"<div class=\"weho-blog\">\n<div class=\"key-takeaways\"><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>SSR drive pulses encode demand through switching time, not a steady analogue level.<\/li>\n<li>An average voltage reading cannot establish output and input compatibility.<\/li>\n<li>Confirm the ordered controller output and the receiver&#8217;s electrical requirements.<\/li>\n<li>Keep relay contacts, SSR drive, linear voltage and load power separate.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"F12-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/de\/product\/tx4-series-tx4-s-economic-dual-display-pid-temperature-controller\/\" aria-label=\"TX4-S details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/acdcda1e844dc939-tx4-s-application.webp\" alt=\"TX4-S product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" title=\"\"><\/a><figcaption>AI-assisted application illustration of TX4-S. Display segments identify the panel context; no particular input curve or control response is demonstrated. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/2ce50d51a5f9fd3d-application-master.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#the-same-meter-reading-can-represent-different-commands\">The same meter reading can represent different commands<\/a><\/li>\n<li><a href=\"#separate-output-type-from-the-controlled-load\">Separate output type from the controlled load<\/a><\/li>\n<li><a href=\"#compare-two-hypothetical-signals-with-the-same-ideal-average\">Compare two hypothetical signals with the same ideal average<\/a><\/li>\n<li><a href=\"#record-the-receiver-as-carefully-as-the-controller\">Record the receiver as carefully as the controller<\/a><\/li>\n<li><a href=\"#verify-the-interface-before-connecting-the-actuator\">Verify the interface before connecting the actuator<\/a><\/li>\n<li><a href=\"#resolve-a-mismatch-before-purchasing-an-adapter\">Resolve a mismatch before purchasing an adapter<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">H\u00e4ufig gestellte Fragen<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Inhaltsverzeichnis<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Umschalten<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#The_same_meter_reading_can_represent_different_commands\" >The same meter reading can represent different commands<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Separate_output_type_from_the_controlled_load\" >Separate output type from the controlled load<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Read_the_rear_label_as_configuration_evidence\" >Read the rear label as configuration evidence<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Compare_two_hypothetical_signals_with_the_same_ideal_average\" >Compare two hypothetical signals with the same ideal average<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Record_the_receiver_as_carefully_as_the_controller\" >Record the receiver as carefully as the controller<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Verify_the_interface_before_connecting_the_actuator\" >Verify the interface before connecting the actuator<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Resolve_a_mismatch_before_purchasing_an_adapter\" >Resolve a mismatch before purchasing an adapter<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Frequently_asked_questions\" >H\u00e4ufig gestellte Fragen<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Can_an_SSR-drive_pulse_output_directly_replace_a_0%E2%80%9310_V_analogue_output\" >Can an SSR-drive pulse output directly replace a 0\u201310 V analogue output?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Does_a_2_V_multimeter_reading_prove_the_controller_has_a_0%E2%80%9310_V_output\" >Does a 2 V multimeter reading prove the controller has a 0\u201310 V output?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Does_the_TX4-S_front-panel_name_establish_its_output_configuration\" >Does the TX4-S front-panel name establish its output configuration?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/de\/news\/ssr-pulse-analogue-interface-check\/#Can_a_capacitor_turn_SSR_pulses_into_a_usable_analogue_command\" >Can a capacitor turn SSR pulses into a usable analogue command?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"the-same-meter-reading-can-represent-different-commands\"><span class=\"ez-toc-section\" id=\"The_same_meter_reading_can_represent_different_commands\"><\/span>The same meter reading can represent different commands<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An SSR-drive output and a 0\u201310 V analogue input are not interchangeable merely because a meter shows a plausible voltage. A time-proportioned command and a continuous level carry different meanings, so a replacement decision must match the complete interface. Identify the controller, the receiver and their connection requirements before applying power to the actuator.<\/p>\n<p>Der <a href=\"https:\/\/www.wehopower.com\/de\/product\/tx4-series-tx4-s-economic-dual-display-pid-temperature-controller\/\">WEHO TX4-S temperature controller<\/a> is the product context for this interface review. The available W1T\/R-2 reference photograph has distinct printed relay and SSR output labels. Those labels do not establish a 0\u201310 V linear output, an installed wiring state or the electrical capacity of every TX4 configuration.<\/p>\n<h2 id=\"separate-output-type-from-the-controlled-load\"><span class=\"ez-toc-section\" id=\"Separate_output_type_from_the_controlled_load\"><\/span>Separate output type from the controlled load<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An SSR drive is a control signal for the input of a compatible solid-state relay, rather than the heater&#39;s load supply. OMRON&#39;s <a href=\"https:\/\/www.ia.omron.com\/support\/glossary\/meaning\/3684.html\" target=\"_blank\" rel=\"noopener\">SSR-drive glossary<\/a> describes the ON\/OFF voltage principle and notes that voltage depends on manufacturer and model. Do not transfer another manufacturer&#39;s example voltage to a WEHO controller.<\/p>\n<p>In time-proportioning control, the controller varies how long the output is ON within a control cycle. OMRON&#39;s <a href=\"https:\/\/www.ia.omron.com\/data_pdf\/guide\/53\/temperature_tg%28further_info%29.pdf\" target=\"_blank\" rel=\"noopener\">temperature-controller technical guide<\/a> explains this intermittent relay or SSR operation. The receiver&#39;s specified input thresholds and timing behaviour still govern whether a particular switching signal is acceptable.<\/p>\n<p>A linear 0\u201310 V command represents demand as a voltage level within the receiver&#39;s defined range. A relay output instead changes the state of contacts and may require a separate source appropriate to the interface. Identify these types from the exact ordered documentation; a shared word such as \u201cvoltage\u201d or \u201coutput\u201d does not resolve the distinction.<\/p>\n<h3 id=\"read-the-rear-label-as-configuration-evidence\"><span class=\"ez-toc-section\" id=\"Read_the_rear_label_as_configuration_evidence\"><\/span>Read the rear label as configuration evidence<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The available TX4-S W1T\/R-2 rear reference shows twelve physical terminal clamps and printed alternative connection outlines. An alternative outline is not an extra fitted terminal or proof of another installed option. Use the actual product label and the applicable diagram together rather than extending wiring from a generic family illustration.<\/p>\n<p>Der <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/11\/TX4.pdf\">WEHO TX4 manual<\/a> distinguishes relay and SSR output selection and cautions that the order information does not make every combination available. This article therefore gives no assumed TX4 SSR-drive voltage, current or linear-output capability. Configuration confirmation comes before receiver matching, especially when replacing an instrument identified only by its front panel.<\/p>\n<figure class=\"article-figure product\" data-asset=\"F12-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/de\/product\/tx4-series-tx4-s-economic-dual-display-pid-temperature-controller\/\" aria-label=\"TX4-S details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/3ac2ffaf271bb0c0-tx4-s-product-reference.webp\" alt=\"TX4-S product reference preserving original housing, model identification and visible connection details for comparison.\" width=\"800\" height=\"800\" decoding=\"async\" title=\"\"><\/a><figcaption>Product reference for TX4-S; original visible identity is retained. Display segments identify the panel context; no particular input curve or control response is demonstrated. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/c996904ae289c83f-product-original.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"compare-two-hypothetical-signals-with-the-same-ideal-average\"><span class=\"ez-toc-section\" id=\"Compare_two_hypothetical_signals_with_the_same_ideal_average\"><\/span>Compare two hypothetical signals with the same ideal average<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Consider an illustrative pulse signal that switches between 0 V and 10 V over a 2.0 s cycle. At 20% duty, the signal is ON for 0.4 s and OFF for 1.6 s. These deliberately assumed values describe a mathematical example; they are not TX4 output ratings, recommended timing settings or measured waveforms.<\/p>\n<p>The ideal time average is 10 V \u00d7 0.20 + 0 V \u00d7 0.80 = 2.0 V. Now consider a separate ideal linear 0\u201310 V interface where a steady 2.0 V represents 20% demand by its defined transfer function. Both examples have a 2.0 V ideal average, but one alternates between endpoints and the other remains at 2.0 V.<\/p>\n<p>A compatible SSR input interprets valid ON and OFF states according to its specifications. An analogue receiver expects a level and may have its own sampling, filtering and out-of-range behaviour. Applying a pulse to that analogue input could produce a filtered response, oscillating interpretation or another model-dependent result; the average arithmetic does not establish any of those behaviours.<\/p>\n<p>An ordinary multimeter may also respond differently depending on measurement mode, integration time and waveform characteristics. A displayed 2.0 V is therefore an observation to investigate, not evidence that the source is a continuous 2.0 V command. Use appropriate instrumentation and the equipment&#39;s approved commissioning method to identify the waveform without exposing the heater to an unverified command.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"F12-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/0811f33ee4d85932-ssr-pulse-analogue-interface-engineering-example.svg\" alt=\"Illustrative SSR pulse and linear voltage waveforms showing different signal meanings despite equal ideal average.\" width=\"1200\" height=\"675\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Assumed 0\/10 V pulses at20% duty and a steady2 V analogue example share an ideal average but differ as interfaces. No TX4 voltage, current, period or analogue-output capability is asserted. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/0811f33ee4d85932-ssr-pulse-analogue-interface-engineering-example.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<caption>Two assumed signal types with the same ideal average; no TX4 electrical rating is implied<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Interface feature<\/th>\n<th scope=\"col\">Illustrative pulse<\/th>\n<th scope=\"col\">Illustrative linear voltage<\/th>\n<th scope=\"col\">Matching question<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Command variable<\/td>\n<td>ON time within a cycle<\/td>\n<td>Continuous voltage level<\/td>\n<td>What does the receiver interpret?<\/td>\n<\/tr>\n<tr>\n<td>Example at 20% demand<\/td>\n<td>0\/10 V; 0.4 s ON per 2.0 s<\/td>\n<td>Steady 2.0 V on a 0\u201310 V scale<\/td>\n<td>Is the required signal type present?<\/td>\n<\/tr>\n<tr>\n<td>Ideal average<\/td>\n<td>2.0 V<\/td>\n<td>2.0 V<\/td>\n<td>Has waveform identity been checked?<\/td>\n<\/tr>\n<tr>\n<td>Electrical checks<\/td>\n<td>ON\/OFF limits, current and timing<\/td>\n<td>Range, loading and reference<\/td>\n<td>Do both data sheets agree?<\/td>\n<\/tr>\n<tr>\n<td>Power function<\/td>\n<td>Receiver control input only<\/td>\n<td>Receiver control input only<\/td>\n<td>Where is the separately rated load path?<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"record-the-receiver-as-carefully-as-the-controller\"><span class=\"ez-toc-section\" id=\"Record_the_receiver_as_carefully_as_the_controller\"><\/span>Record the receiver as carefully as the controller<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A receiver described as a power controller may accept several optional input types, with only one fitted or selected. Obtain its complete model, input diagram and configuration record. Check signal reference, polarity, input loading and isolation requirements without assuming that two negative-labelled terminals can always be joined.<\/p>\n<p>Manufacturers normally state these interface classes separately. For example, OMRON&#39;s <a href=\"https:\/\/www.ia.omron.com\/products\/family\/3101\/specification.html\" target=\"_blank\" rel=\"noopener\">controller specification table<\/a> distinguishes SSR-drive voltage, relay and linear outputs. This source illustrates why the categories must be checked; its available options and ratings are not a specification for WEHO products or the selected receiver.<\/p>\n<h2 id=\"verify-the-interface-before-connecting-the-actuator\"><span class=\"ez-toc-section\" id=\"Verify_the_interface_before_connecting_the_actuator\"><\/span>Verify the interface before connecting the actuator<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Identify both ordered devices.<\/strong> Record the controller&#39;s full rear label, receiver model, terminal drawing and applicable manual revisions. Acceptance requires a confirmed output type and a confirmed input type, not a family-level assumption.<\/li>\n<li><strong>Compare the electrical requirements.<\/strong> Record the source&#39;s documented levels, available current or contact function and the receiver&#39;s loading, reference and timing requirements. Approve only a compatible pair; leave missing TX4 values unresolved until the applicable documentation is confirmed.<\/li>\n<li><strong>Plan a controlled signal check.<\/strong> Qualified personnel should follow the equipment procedure with the hazardous load prevented from responding unexpectedly. Record instrument type, connection arrangement and isolation provisions; acceptance requires a method suitable for the signal and its reference.<\/li>\n<li><strong>Observe representative demands.<\/strong> Compare low, intermediate and high commanded outputs using permitted settings and appropriate observation time. Record waveform or stable level, period where relevant, and receiver interpretation; the criterion is agreement with the documented interface rather than a convenient average reading.<\/li>\n<li><strong>Release the complete control path.<\/strong> Restore the approved load arrangement and complete the machine&#39;s functional checks. Preserve device identities, settings, wiring revision and test observations; any later output-type substitution should trigger another compatibility review.<\/li>\n<\/ol>\n<p>Signal verification and independent fault control remain separate engineering tasks. A correct command interface does not establish how the machine responds to a failed power switch, sensor fault or lost reference. WEHO&#39;s <a href=\"https:\/\/www.wehopower.com\/de\/news\/tx4-temperature-alarm-external-interlock-setup\/\">TX4 alarm and external interlock guide<\/a> addresses the separate alarm\/interlock boundary without making a pulse output a protective device.<\/p>\n<h2 id=\"resolve-a-mismatch-before-purchasing-an-adapter\"><span class=\"ez-toc-section\" id=\"Resolve_a_mismatch_before_purchasing_an_adapter\"><\/span>Resolve a mismatch before purchasing an adapter<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An interface converter is a component choice that needs its own specified input, output, dynamics and failure behaviour. A simple smoothing capacitor changes the waveform but does not automatically create a calibrated, isolated or correctly referenced industrial analogue interface. Select any conversion arrangement through the machine&#39;s engineering review rather than improvising one from the average-voltage equation.<\/p>\n<p>Send WEHO the <a href=\"https:\/\/www.wehopower.com\/de\/product\/tx4-series-tx4-s-economic-dual-display-pid-temperature-controller\/\">TX4-S full model identification<\/a>, a legible rear-label photo, the receiver&#39;s exact input specification and the intended wiring drawing. State whether the requested command is SSR time proportioning, relay contact operation or a linear analogue signal. Request the applicable output confirmation before approving the purchase or replacement.<\/p>\n<h2 id=\"frequently-asked-questions\"><span class=\"ez-toc-section\" id=\"Frequently_asked_questions\"><\/span>H\u00e4ufig gestellte Fragen<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"can-an-ssr-drive-pulse-output-directly-replace-a-0-10-v-analogue-output\"><span class=\"ez-toc-section\" id=\"Can_an_SSR-drive_pulse_output_directly_replace_a_0%E2%80%9310_V_analogue_output\"><\/span>Can an SSR-drive pulse output directly replace a 0\u201310 V analogue output?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No, direct replacement requires a documented compatible receiver or an appropriately specified conversion arrangement. An SSR drive carries switching states and timing, while a linear input expects a level. Confirm both device specifications before connecting the control path.<\/p>\n<h3 id=\"does-a-2-v-multimeter-reading-prove-the-controller-has-a-0-10-v-output\"><span class=\"ez-toc-section\" id=\"Does_a_2_V_multimeter_reading_prove_the_controller_has_a_0%E2%80%9310_V_output\"><\/span>Does a 2 V multimeter reading prove the controller has a 0\u201310 V output?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No, a single meter reading does not identify the waveform or its command meaning. Pulses can have the same ideal average as a steady level, and meter response depends on its measurement method. Verify the output type and observe it with suitable instrumentation.<\/p>\n<h3 id=\"does-the-tx4-s-front-panel-name-establish-its-output-configuration\"><span class=\"ez-toc-section\" id=\"Does_the_TX4-S_front-panel_name_establish_its_output_configuration\"><\/span>Does the TX4-S front-panel name establish its output configuration?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No, the family name does not establish the complete ordered output configuration. Check the full rear label and the applicable manual or supplier confirmation. Printed alternative diagrams do not prove that all shown options are fitted to the instrument.<\/p>\n<h3 id=\"can-a-capacitor-turn-ssr-pulses-into-a-usable-analogue-command\"><span class=\"ez-toc-section\" id=\"Can_a_capacitor_turn_SSR_pulses_into_a_usable_analogue_command\"><\/span>Can a capacitor turn SSR pulses into a usable analogue command?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A capacitor alone does not establish a compatible industrial analogue interface. Loading, scaling, timing, isolation, reference and fault behaviour still need engineering verification. Use a documented conversion arrangement where required, and validate the complete controller-to-receiver path before release.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Compare SSR drive pulses with linear 0\u201310 V commands, then send WEHO the TX4-S label and receiver input specification before approving the connection.<\/p>","protected":false},"author":2,"featured_media":22223,"parent":0,"menu_order":29,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-23423","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/23423","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/comments?post=23423"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/23423\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media\/22223"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media?parent=23423"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news_category?post=23423"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}