{"id":23575,"date":"2026-11-22T10:08:48","date_gmt":"2026-11-22T02:08:48","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/inverter-frequency-log-clock-error\/"},"modified":"2026-11-22T10:08:48","modified_gmt":"2026-11-22T02:08:48","slug":"inverter-frequency-log-clock-error","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/","title":{"rendered":"WHP-2000 Frequency Logs: Separate Display Resolution from Clock Error"},"content":{"rendered":"<div class=\"weho-blog\">\n<p>A frequency display&#39;s decimal places do not establish its accuracy. Review the counter&#39;s timebase, observation method and response interval before using a frequency log to accept an inverter or diagnose a brief event.<\/p>\n<ul>\n<li>Separate display resolution from measurement uncertainty.<\/li>\n<li>Distinguish long-window average frequency from short-event behavior.<\/li>\n<li>Record the actual instrument and timebase conditions with the result.<\/li>\n<\/ul>\n<figure data-role=\"hero\"><a href=\"https:\/\/www.wehopower.com\/de\/product\/2000w-12v-24v-48v-dc-ac-110v-220v-pure-sine-wave-power-inverter\/\" aria-label=\"View WHP-2000 product details\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/f7288f74e23f3e75-whp-2000-inverter-application.avif\" width=\"1200\" height=\"675\" alt=\"WHP-2000 secured in an equipment setting with its front AC connection routed to the load.\" data-image-role=\"hero\" loading=\"eager\" title=\"\"><\/a><figcaption>Application illustration; not a customer installation photo. Scene created with AI assistance. WHP-2000 acquisition context includes a generic interface and blank recorder; no frequency reading or timebase performance is depicted. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/c72181897b6c2c11-original-hero.webp\">View source image<\/a><\/figcaption><\/figure>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Inhaltsverzeichnis<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Umschalten<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#What_question_should_the_frequency_log_answer\" >What question should the frequency log answer?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#How_does_timebase_uncertainty_affect_a_frequency_result\" >How does timebase uncertainty affect a frequency result?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#Why_can_a_longer_observation_hide_a_short_event\" >Why can a longer observation hide a short event?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#How_should_the_acceptance_method_be_specified\" >How should the acceptance method be specified?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#What_belongs_in_a_supplier_frequency_report\" >What belongs in a supplier frequency report?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#Prepare_a_WHP-2000_frequency_review\" >Prepare a WHP-2000 frequency review<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#Frequently_asked_questions\" >H\u00e4ufig gestellte Fragen<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#Do_four_decimal_places_prove_high_frequency_accuracy\" >Do four decimal places prove high frequency accuracy?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#Is_a_longer_gate_time_always_better\" >Is a longer gate time always better?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#Does_a_0010_Hz_difference_always_shift_a_device_clock_by_072_seconds_per_hour\" >Does a 0.010 Hz difference always shift a device clock by 0.72 seconds per hour?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/de\/news\/inverter-frequency-log-clock-error\/#Can_a_counter_be_connected_directly_to_inverter_output\" >Can a counter be connected directly to inverter output?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"what-question-should-the-frequency-log-answer\"><span class=\"ez-toc-section\" id=\"What_question_should_the_frequency_log_answer\"><\/span>What question should the frequency log answer?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A log may be intended to check steady frequency, identify a disturbance or estimate accumulated timing difference. Those are related but different questions. The instrument and observation window should be selected for the actual requirement rather than for the number of digits available on its screen.<\/p>\n<p>For a <a href=\"https:\/\/www.wehopower.com\/de\/product\/2000w-12v-24v-48v-dc-ac-110v-220v-pure-sine-wave-power-inverter\/\">WHP-2000 inverter project<\/a>, confirm the ordered AC output option and applicable requirement. A family page listing multiple options does not mean the photographed unit can be set to all of them. The measurement plan must match the delivered configuration.<\/p>\n<p>The application scene is not a frequency test record. Its image cannot establish 50 Hz, 60 Hz, stability or transient response. The examples below use an explicit hypothetical 50 Hz reference solely to explain timebase and observation effects.<\/p>\n<p>An OEM report should state whether it needs a settled average within a tolerance, an event-duration limit or a timing outcome for a connected device. A result suitable for one purpose can conceal behavior relevant to another, even when the reported average is numerically correct.<\/p>\n<nav aria-label=\"Article contents\">\n<details>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#what-question-should-the-frequency-log-answer\">What question should the frequency log answer?<\/a><\/li>\n<li><a href=\"#how-does-timebase-uncertainty-affect-a-frequency-result\">How does timebase uncertainty affect a frequency result?<\/a><\/li>\n<li><a href=\"#why-can-a-longer-observation-hide-a-short-event\">Why can a longer observation hide a short event?<\/a><\/li>\n<li><a href=\"#how-should-the-acceptance-method-be-specified\">How should the acceptance method be specified?<\/a><\/li>\n<li><a href=\"#what-belongs-in-a-supplier-frequency-report\">What belongs in a supplier frequency report?<\/a><\/li>\n<li><a href=\"#prepare-a-whp-2000-frequency-review\">Prepare a WHP-2000 frequency review<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">H\u00e4ufig gestellte Fragen<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<h2 id=\"how-does-timebase-uncertainty-affect-a-frequency-result\"><span class=\"ez-toc-section\" id=\"How_does_timebase_uncertainty_affect_a_frequency_result\"><\/span>How does timebase uncertainty affect a frequency result?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A counter derives time from a reference. Uncertainty or drift in that reference contributes to the frequency measurement. Displaying more digits can improve resolution without reducing a systematic timebase contribution, so the least displayed digit is not the complete error bound.<\/p>\n<p>Consider a <strong>hypothetical<\/strong> 50.000 Hz signal and an illustrative counter timebase contribution of \u00b120 parts per million under the stated conditions. Its frequency contribution is 50 \u00d7 20\/1,000,000 = \u00b10.001 Hz. Other contributions, including trigger and measurement method, remain separate.<\/p>\n<p>A display resolving 0.0001 Hz therefore does not by itself establish accuracy to \u00b10.0001 Hz. In the example, the timebase contribution alone is ten times that resolution step. This is a calculation of one assumed contribution, not a specification for a real instrument or WHP-2000 unit.<\/p>\n<p>If a signal is truly 0.010 Hz above 50 Hz for one hour, it accumulates 0.010 \u00d7 3600 = 36 extra cycles relative to a 50 Hz reference. For an ideal clock counting input cycles at that nominal frequency, that corresponds to 36\/50 = 0.72 seconds. An arbitrary connected device may use another time reference.<\/p>\n<figure data-role=\"technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/7b052a58680552d4-inverter-frequency-log-clock-error-engineering.svg\" width=\"1200\" height=\"675\" alt=\"Counter example separates timebase error, display resolution and accumulated cycles under stated assumptions.\" data-image-role=\"technical\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Hypothetical model. A receiver with its own clock need not follow the AC cycle count. All numerical inputs are hypothetical unless identified as mathematical relationships; no measured product performance is presented. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/7b052a58680552d4-inverter-frequency-log-clock-error-engineering.svg\">View source image<\/a><\/figcaption><\/figure>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th>Hypothetical quantity<\/th>\n<th>Example value<\/th>\n<th>Interpretation<\/th>\n<th>Limitation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Nominal signal<\/td>\n<td>50.000 Hz<\/td>\n<td>Chosen calculation reference<\/td>\n<td>Not a measured product result<\/td>\n<\/tr>\n<tr>\n<td>Timebase contribution<\/td>\n<td>\u00b120 ppm<\/td>\n<td>\u00b10.001 Hz at 50 Hz<\/td>\n<td>Other measurement terms remain<\/td>\n<\/tr>\n<tr>\n<td>Display increment<\/td>\n<td>0.0001 Hz<\/td>\n<td>Resolution of the example display<\/td>\n<td>Not total accuracy<\/td>\n<\/tr>\n<tr>\n<td>Actual +0.010 Hz for one hour<\/td>\n<td>36 extra cycles<\/td>\n<td>0.72 s for the stated ideal cycle-counting clock<\/td>\n<td>Does not describe every receiver clock<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"why-can-a-longer-observation-hide-a-short-event\"><span class=\"ez-toc-section\" id=\"Why_can_a_longer_observation_hide_a_short_event\"><\/span>Why can a longer observation hide a short event?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A longer measurement interval can improve some resolution terms while averaging over changes inside that interval. A brief frequency departure may have a modest effect on the reported average. If the requirement concerns a short event, the acquisition and reporting method must preserve enough timing information to reveal it.<\/p>\n<p>Consider an idealized ten-second average containing nine seconds at 50 Hz and one second at 49 Hz. The total is 9 \u00d7 50 + 1 \u00d7 49 = 499 cycles, giving a ten-second average of 49.9 Hz. That average does not show the one-second state directly.<\/p>\n<p>A logger updating once per second does not necessarily measure only that second or provide gap-free event coverage. It may report overlapping averages, perform internal filtering or omit intervals. Check the actual instrument&#39;s architecture and exported data definition before interpreting the timestamp as an exact acquisition boundary.<\/p>\n<p><a href=\"https:\/\/www.keysight.com\/ch\/de\/lib\/resources\/training-materials\/tips-for-making-more-accurate-measurements-with-a-frequency-counter-505277.html\" target=\"_blank\" rel=\"noopener\">Keysight&#39;s frequency-counter measurement guidance<\/a> discusses timebase and observation considerations. Follow the selected counter&#39;s specifications for its actual method. This source does not establish inverter frequency performance or a universal observation interval.<\/p>\n<h2 id=\"how-should-the-acceptance-method-be-specified\"><span class=\"ez-toc-section\" id=\"How_should_the_acceptance_method_be_specified\"><\/span>How should the acceptance method be specified?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Write the required frequency interval, applicable load and input conditions, observation duration and event treatment. Include a decision rule that considers the measurement uncertainty relevant to the requirement. A tolerance narrower than the method can support should trigger a method review rather than more displayed digits.<\/p>\n<ol>\n<li>Confirm the supplied inverter option and the required frequency quantity.<\/li>\n<li>Select a rated measurement interface and suitable counter or analyzer.<\/li>\n<li>Record timebase source, relevant calibration state and operating conditions.<\/li>\n<li>Define averaging, update interval and any gaps or event triggers.<\/li>\n<li>Preserve raw results and compare them with the pre-established criterion.<\/li>\n<\/ol>\n<p>Qualified personnel should use an appropriate isolated or otherwise suitable rated interface to inverter AC output. A frequency counter input may not accept the output voltage directly. Verify voltage, reference and transient limits for the complete measurement arrangement before connecting it.<\/p>\n<p>For event investigation, synchronize relevant load and input observations where necessary. An apparent frequency change may coincide with waveform distortion or triggering difficulty, so inspect signal quality rather than assuming every reported excursion represents the fundamental frequency accurately.<\/p>\n<h2 id=\"what-belongs-in-a-supplier-frequency-report\"><span class=\"ez-toc-section\" id=\"What_belongs_in_a_supplier_frequency_report\"><\/span>What belongs in a supplier frequency report?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Include instrument model, interface, function, timebase conditions and the actual observation definition. State whether the values represent settled averages, event captures or derived cycle counts. Preserve the load and inverter-input conditions associated with each result.<\/p>\n<p>Der <a href=\"https:\/\/www.wehopower.com\/de\/product\/2000w-12v-24v-48v-dc-ac-110v-220v-pure-sine-wave-power-inverter\/\">WHP-2000 product information<\/a> is the model entry for obtaining the applicable output documentation. Do not substitute the example&#39;s 50 Hz or assumed \u00b120 ppm term for the delivered unit&#39;s requirement or the instrument&#39;s real specification.<\/p>\n<p>Distinguish an instrument clock from the device under test. A logger timestamp can drift independently of the frequency measurement reference, while a connected machine may use its own oscillator rather than count AC cycles. The 0.72-second example applies only to the explicitly defined ideal clock model.<\/p>\n<p>A useful report can also state what was not measured. A steady ten-second average does not establish the maximum instantaneous departure, and a short capture does not establish long-term drift. These are scope distinctions, not reasons to invent an all-purpose pass\/fail statement.<\/p>\n<p>An exported timestamp may identify the end of an acquisition rather than its center or start. That distinction matters when correlating a reported departure with a load event. Use the instrument&#39;s documented timestamp convention instead of assuming all channels describe the same instant.<\/p>\n<p>A repeat test should also preserve the timebase source. Changing from an internal reference to an external one can alter the uncertainty and traceability of the result. Record the actual reference and its conditions rather than describing both captures simply as frequency measurements.<\/p>\n<figure data-role=\"product\"><a href=\"https:\/\/www.wehopower.com\/de\/product\/2000w-12v-24v-48v-dc-ac-110v-220v-pure-sine-wave-power-inverter\/\" aria-label=\"View WHP-2000 product details\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/834efd0f23efc9a6-whp-2000-inverter-product-reference.avif\" width=\"1000\" height=\"1000\" alt=\"Official WHP-2000 product photograph preserving the original enclosure, front interfaces and visible label.\" data-image-role=\"product\" title=\"\"><\/a><figcaption>Manufacturer WHP-2000 identity reference. Original visible markings are preserved; the image does not identify every available ordered DC or AC option. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/6ce064c35a7412fc-original-official-product-1.jpg\">View source image<\/a><\/figcaption><\/figure>\n<h2 id=\"prepare-a-whp-2000-frequency-review\"><span class=\"ez-toc-section\" id=\"Prepare_a_WHP-2000_frequency_review\"><\/span>Prepare a WHP-2000 frequency review<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Send WEHO the supplied option, required frequency criterion, instrument\/interface details and exported log definition. Include relevant operating states and any waveform evidence for reported excursions. This allows the discussion to distinguish real output behavior, measurement limitations and a separate receiver-timing requirement.<\/p>\n<h2 id=\"frequently-asked-questions\"><span class=\"ez-toc-section\" id=\"Frequently_asked_questions\"><\/span>H\u00e4ufig gestellte Fragen<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"do-four-decimal-places-prove-high-frequency-accuracy\"><span class=\"ez-toc-section\" id=\"Do_four_decimal_places_prove_high_frequency_accuracy\"><\/span>Do four decimal places prove high frequency accuracy?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. They describe display resolution. Timebase, trigger, method and operating conditions determine the measurement uncertainty relevant to the acceptance decision.<\/p>\n<h3 id=\"is-a-longer-gate-time-always-better\"><span class=\"ez-toc-section\" id=\"Is_a_longer_gate_time_always_better\"><\/span>Is a longer gate time always better?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Not for every task. It can improve some measurement terms while averaging over short events. Select the observation method for the required steady or transient quantity.<\/p>\n<h3 id=\"does-a-0-010-hz-difference-always-shift-a-device-clock-by-0-72-seconds-per-hour\"><span class=\"ez-toc-section\" id=\"Does_a_0010_Hz_difference_always_shift_a_device_clock_by_072_seconds_per_hour\"><\/span>Does a 0.010 Hz difference always shift a device clock by 0.72 seconds per hour?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Only for the stated ideal cycle-counting model at a 50 Hz reference. A device using an independent clock does not necessarily follow the AC cycle count.<\/p>\n<h3 id=\"can-a-counter-be-connected-directly-to-inverter-output\"><span class=\"ez-toc-section\" id=\"Can_a_counter_be_connected_directly_to_inverter_output\"><\/span>Can a counter be connected directly to inverter output?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Only if the complete input arrangement is explicitly suitable and rated. Many counter inputs require an appropriate interface; qualified personnel must establish the actual voltage and reference conditions.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Review WHP-2000 frequency records using the counter timebase and observation window. Separate display precision from a validated frequency result.<\/p>","protected":false},"author":2,"featured_media":23551,"parent":0,"menu_order":16,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-23575","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/23575","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/comments?post=23575"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/23575\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media\/23551"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media?parent=23575"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news_category?post=23575"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}