{"id":23600,"date":"2026-11-23T10:20:07","date_gmt":"2026-11-23T02:20:07","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/dc-connection-ringing-pulse-stress\/"},"modified":"2026-11-23T10:20:07","modified_gmt":"2026-11-23T02:20:07","slug":"dc-connection-ringing-pulse-stress","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/","title":{"rendered":"DC Connection Ringing: Check Cable Inductance and Pulse Stress"},"content":{"rendered":"<div class=\"weho-blog\">\n<p>Connecting an energized DC path to uncharged input capacitance can create a local voltage peak above the source&#39;s steady voltage. Qualify the connection transient and any damping component&#39;s pulse stress together; a clean steady-state voltage does not answer either question.<\/p>\n<div class=\"key-takeaways\"><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Include cable inductance and capacitor initial voltage.<\/li>\n<li>Observe voltage at the receiving input, not only the source.<\/li>\n<li>Separate damping pulse energy from average resistor wattage.<\/li>\n<li>Treat energized connection permission as a separate design requirement.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"K08-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/product\/ndr-dinrail-240w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"NDR-240-24 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/dfde7b4c2a46e5ee-ndr-240-24-application.webp\" alt=\"NDR-240-24 product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" fetchpriority=\"high\" decoding=\"async\" title=\"\"><\/a><figcaption>Application illustration of NDR-240-24 in an equipment setting; not a customer installation photo. Scene created with AI assistance. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/5d20177cce824342-application-master.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#1-define-the-connection-event-before-choosing-a-remedy\">1. Define the connection event before choosing a remedy<\/a><\/li>\n<li><a href=\"#2-keep-initial-condition-ringing-separate-from-running-stability\">2. Keep initial-condition ringing separate from running stability<\/a><\/li>\n<li><a href=\"#3-recalculate-an-ideal-connection-model\">3. Recalculate an ideal connection model<\/a><\/li>\n<li><a href=\"#4-screen-pulse-stress-using-a-separate-declared-model\">4. Screen pulse stress using a separate declared model<\/a><\/li>\n<li><a href=\"#5-qualify-the-complete-approved-interface\">5. Qualify the complete approved interface<\/a><\/li>\n<li><a href=\"#6-prepare-the-integration-question\">6. Prepare the integration question<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Frequently Asked Questions<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#1_Define_the_connection_event_before_choosing_a_remedy\" >1. Define the connection event before choosing a remedy<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#2_Keep_initial-condition_ringing_separate_from_running_stability\" >2. Keep initial-condition ringing separate from running stability<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#3_Recalculate_an_ideal_connection_model\" >3. Recalculate an ideal connection model<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#4_Screen_pulse_stress_using_a_separate_declared_model\" >4. Screen pulse stress using a separate declared model<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#5_Qualify_the_complete_approved_interface\" >5. Qualify the complete approved interface<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#6_Prepare_the_integration_question\" >6. Prepare the integration question<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#Frequently_Asked_Questions\" >Frequently Asked Questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#Can_the_receiving_input_exceed_the_nominal_source_voltage_during_connection\" >Can the receiving input exceed the nominal source voltage during connection?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#Does_adding_a_capacitor_always_remove_the_problem\" >Does adding a capacitor always remove the problem?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#Is_a_low_average_resistor_power_enough_to_select_a_damping_resistor\" >Is a low average resistor power enough to select a damping resistor?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/de\/news\/dc-connection-ringing-pulse-stress\/#Does_this_analysis_authorize_plugging_live_wires_into_a_power-supply_terminal\" >Does this analysis authorize plugging live wires into a power-supply terminal?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"1-define-the-connection-event-before-choosing-a-remedy\"><span class=\"ez-toc-section\" id=\"1_Define_the_connection_event_before_choosing_a_remedy\"><\/span>1. Define the connection event before choosing a remedy<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An equipment engineer investigating an input failure should identify the switching event first. Source power-up with the load already connected differs from connecting an already energized cable to an initially uncharged board. Initial capacitor voltage, source impedance and contact behavior can change the resulting waveform.<\/p>\n<p>The <a href=\"https:\/\/www.wehopower.com\/product\/ndr-dinrail-240w-ac-to-dc-single-output-switching-power-supply\/\">WEHO NDR-240-24 product reference<\/a> identifies a possible upstream 24 V source. This article examines an external connection interface. It does not claim that the model permits energized manual connections, contains a specified damping circuit or has the ideal source behavior used in the calculations.<\/p>\n<p><a href=\"https:\/\/www.analog.com\/media\/en\/technical-documentation\/application-notes\/an88f.pdf\" target=\"_blank\" rel=\"noopener\">Analog Devices AN88<\/a> describes overvoltage transients produced by lead inductance and low-ESR input capacitance. A nominal voltage label alone therefore cannot establish the receiver&#39;s connection peak. The actual source, cable, receiving network and approved switching arrangement belong inside the investigation.<\/p>\n<h2 id=\"2-keep-initial-condition-ringing-separate-from-running-stability\"><span class=\"ez-toc-section\" id=\"2_Keep_initial-condition_ringing_separate_from_running_stability\"><\/span>2. Keep initial-condition ringing separate from running stability<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The existing <a href=\"https:\/\/www.wehopower.com\/news\/dc-dc-input-filter-resonance-source-impedance\/\">input-filter resonance guide<\/a> addresses source\/filter\/converter interaction, including startup validation. The narrower task here is the first connection transient: how an energized source charges a receiving capacitance and what pulse stress appears in a proposed damping path.<\/p>\n<p><a href=\"https:\/\/www.ti.com\/lit\/an\/sluaal8\/sluaal8.pdf\" target=\"_blank\" rel=\"noopener\">TI&#39;s hot-plug overshoot application note<\/a> models cable inductance, input capacitance and damping in its named charger application. Its component examples are not transferable installation values for an NDR system. Use the selected receiver&#39;s absolute limits and the complete network before evaluating a remedy.<\/p>\n<p>Reducing a resonance peak can change inrush, startup time and source loading. Adding capacitance is not an unconditional improvement, and adding resistance can create its own short-duration stress. A component selected only from nominal capacitance or continuous wattage can miss the relevant failure mechanism.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Boundary<\/th>\n<th scope=\"col\">Required information<\/th>\n<th scope=\"col\">What it determines<\/th>\n<th scope=\"col\">Evidence to retain<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Source and cable<\/td>\n<td>Voltage, impedance, inductance and source state<\/td>\n<td>Applied step and energy path<\/td>\n<td>Configuration and local waveform<\/td>\n<\/tr>\n<tr>\n<td>Receiving input<\/td>\n<td>Capacitance, bias dependence and initial voltage<\/td>\n<td>Connection response<\/td>\n<td>Applicable component data<\/td>\n<\/tr>\n<tr>\n<td>Damping network<\/td>\n<td>Topology, pulse limits and repetition<\/td>\n<td>Resistor\/capacitor stress<\/td>\n<td>Waveform and energy calculation<\/td>\n<\/tr>\n<tr>\n<td>Connection hardware<\/td>\n<td>Approved switching and mating conditions<\/td>\n<td>Whether the event is permitted<\/td>\n<td>Documented design approval<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"3-recalculate-an-ideal-connection-model\"><span class=\"ez-toc-section\" id=\"3_Recalculate_an_ideal_connection_model\"><\/span>3. Recalculate an ideal connection model<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assume an ideal 24 V step source, a series inductance of 2 \u00b5H and an initially uncharged 10 \u00b5F capacitor. Ignore resistance, source regulation, load current and contact bounce solely for this mathematical illustration. The invented network is not a characterization of an NDR-240-24 or an actual cable assembly.<\/p>\n<p>For this ideal lossless series LC step response, capacitor voltage is Vc(t) = Vs \u00d7 [1 \u2212 cos(t\/\u221a(LC))]. The natural frequency is 1\/[2\u03c0\u221a(LC)] \u2248 35.59 kHz. The first peak occurs at \u03c0\u221a(LC) \u2248 14.05 \u00b5s, where Vc reaches 2Vs = 48 V.<\/p>\n<p>The factor of two belongs to these explicit initial conditions and this ideal model. Real damping, finite source behavior, capacitor characteristics and protection can change the waveform. Other initial conditions or switching behavior can also produce a different result; 48 V is neither a prediction nor an upper guarantee for the illustrated product.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"K08-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/bae4bd0053ee6235-technical.svg\" alt=\"Ideal capacitor voltage peaks above its source during an explicitly assumed lossless connection transient.\" width=\"1200\" height=\"675\" loading=\"lazy\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Ideal 24 V step through 2 \u00b5H into uncharged 10 \u00b5F, with zero resistance and no load; the 48 V first peak is not a WEHO measurement or guaranteed bound. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/bae4bd0053ee6235-technical.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>For the same illustrative inductance and capacitance, a simple series RLC model reaches critical damping at Rcrit = 2\u221a(L\/C) \u2248 0.894 \u03a9. This is the total series resistance of that idealized topology. It is not a recommended resistor value or an RC snubber design for the actual equipment.<\/p>\n<p>A practical damping network can use a separate resistor-capacitor branch rather than putting that resistance directly in the operating load path. Those are different circuits. Do not take the critical-damping value from one topology and assign it to another without deriving and validating the complete response.<\/p>\n<h2 id=\"4-screen-pulse-stress-using-a-separate-declared-model\"><span class=\"ez-toc-section\" id=\"4_Screen_pulse_stress_using_a_separate_declared_model\"><\/span>4. Screen pulse stress using a separate declared model<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Consider a separate ideal RC charging example: an initially uncharged 10 \u00b5F damping capacitor charges from an ideal 24 V source through 2 \u03a9. This example has no series inductor and is not the previous LC waveform. Initial resistor power is 24\u00b2\/2 = 288 W, and the time constant is RC = 20 \u00b5s.<\/p>\n<p>The resistor&#39;s total charging energy in this RC model is \u00bdCV\u00b2 = 2.88 mJ. Capacitor stored energy at the final 24 V is also 2.88 mJ. The source supplies 5.76 mJ overall; half becomes stored energy and half resistor heat under these ideal assumptions.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Invented model<\/th>\n<th scope=\"col\">Calculation<\/th>\n<th scope=\"col\">Result<\/th>\n<th scope=\"col\">Boundary<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Lossless LC frequency<\/td>\n<td>1\/[2\u03c0\u221a(2 \u00b5H \u00d7 10 \u00b5F)]<\/td>\n<td>35.59 kHz<\/td>\n<td>No damping or load<\/td>\n<\/tr>\n<tr>\n<td>Lossless LC first peak<\/td>\n<td>\u03c0\u221a(LC); 2 \u00d7 24 V<\/td>\n<td>14.05 \u00b5s; 48 V<\/td>\n<td>Initially uncharged capacitor<\/td>\n<\/tr>\n<tr>\n<td>Separate RC initial stress<\/td>\n<td>24\u00b2\/2 \u03a9<\/td>\n<td>288 W<\/td>\n<td>Ideal RC circuit only<\/td>\n<\/tr>\n<tr>\n<td>Separate RC pulse energy<\/td>\n<td>\u00bd \u00d7 10 \u00b5F \u00d7 24\u00b2<\/td>\n<td>2.88 mJ<\/td>\n<td>Complete charging event<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>At an invented repetition rate of one fully discharged charging event per second, average resistor dissipation from these pulses is only 2.88 mW. That small average does not establish survival of the 288 W initial pulse. Review the selected resistor&#39;s applicable pulse-energy, waveform, voltage, repetition and thermal restrictions.<\/p>\n<p><a href=\"https:\/\/www.ti.com\/document-viewer\/lit\/html\/SSZTDA5\/GUID-A708FC6E-38D2-4FCF-BEB3-0E9E75E1FCEC\" target=\"_blank\" rel=\"noopener\">TI&#39;s damping-resistor discussion<\/a> explicitly addresses this pulse-power and energy problem. Its named laboratory example motivates the check; the values above are independently chosen arithmetic. Validate the actual circuit rather than selecting a resistor from the example alone.<\/p>\n<figure class=\"article-figure product\" data-asset=\"K08-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/product\/ndr-dinrail-240w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"NDR-240-24 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/2e3b109c73664e7b-ndr-240-24-product-reference.webp\" alt=\"NDR-240-24 product reference preserving the original housing, visible label and connection features.\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\" title=\"\"><\/a><figcaption>Product appearance reference for NDR-240-24, preserving the source housing, visible label and connections. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/1b88961a2a1ee7e5-product-original.jpg\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"5-qualify-the-complete-approved-interface\"><span class=\"ez-toc-section\" id=\"5_Qualify_the_complete_approved_interface\"><\/span>5. Qualify the complete approved interface<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Identify the event.<\/strong> Record source state, capacitor initial voltage, switching arrangement and connected load. Verify that the evaluated connection condition is permitted by the hardware design.<\/li>\n<li><strong>Bound the network.<\/strong> Record cable geometry, estimated or measured inductance, capacitance characteristics and damping topology. Verify that the model represents the actual receiving input.<\/li>\n<li><strong>Capture the transient.<\/strong> Record source and local receiver voltage with appropriate measurement bandwidth and probing. Verify that the observed peak is real and its uncertainty is understood.<\/li>\n<li><strong>Check component stress.<\/strong> Record pulse voltage, current, duration, energy and repetition. Verify each relevant limit against applicable component documentation and the defined conditions.<\/li>\n<li><strong>Repeat the required corners.<\/strong> Record cable variants, temperatures, source states and repeated-event results. Verify receiver operation and source recovery as well as the absence of unacceptable component stress.<\/li>\n<\/ol>\n<p>A successful first connection does not qualify repeated operation after partial discharge. A capacitor retaining voltage changes the next event&#39;s initial condition. Record that residual state when the service sequence allows short intervals, and evaluate any contact bounce under an appropriate controlled test plan.<\/p>\n<h2 id=\"6-prepare-the-integration-question\"><span class=\"ez-toc-section\" id=\"6_Prepare_the_integration_question\"><\/span>6. Prepare the integration question<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For an <a href=\"https:\/\/www.wehopower.com\/product\/ndr-dinrail-240w-ac-to-dc-single-output-switching-power-supply\/\">NDR-240-24 interface review<\/a>, provide the source configuration, receiving schematic, cable variants, initial states and measured local waveform. Include the proposed damping components and their stress calculations. Request matching supply information while the equipment team qualifies the complete connection arrangement and receiver requirements.<\/p>\n<h2 id=\"frequently-asked-questions\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Frequently Asked Questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"can-the-receiving-input-exceed-the-nominal-source-voltage-during-connection\"><span class=\"ez-toc-section\" id=\"Can_the_receiving_input_exceed_the_nominal_source_voltage_during_connection\"><\/span>Can the receiving input exceed the nominal source voltage during connection?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes. An inductive path charging low-loss input capacitance can ring above the steady source voltage. The actual peak depends on the complete circuit and event, so measure it at the receiver.<\/p>\n<h3 id=\"does-adding-a-capacitor-always-remove-the-problem\"><span class=\"ez-toc-section\" id=\"Does_adding_a_capacitor_always_remove_the_problem\"><\/span>Does adding a capacitor always remove the problem?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Added capacitance changes resonance, inrush and stored energy. Qualify its characteristics, damping and source interaction rather than treating capacitance alone as the remedy.<\/p>\n<h3 id=\"is-a-low-average-resistor-power-enough-to-select-a-damping-resistor\"><span class=\"ez-toc-section\" id=\"Is_a_low_average_resistor_power_enough_to_select_a_damping_resistor\"><\/span>Is a low average resistor power enough to select a damping resistor?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. A short charging pulse can have high peak power despite a small average. The selected part needs applicable pulse, voltage, repetition and thermal evidence.<\/p>\n<h3 id=\"does-this-analysis-authorize-plugging-live-wires-into-a-power-supply-terminal\"><span class=\"ez-toc-section\" id=\"Does_this_analysis_authorize_plugging_live_wires_into_a_power-supply_terminal\"><\/span>Does this analysis authorize plugging live wires into a power-supply terminal?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Connection permission depends on the equipment and connection hardware. This article defines a design-validation question, not a live-wiring or load-breaking instruction.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Evaluate local DC connection overshoot from cable inductance and input capacitance, then check damping pulse energy separately from average resistor power.<\/p>","protected":false},"author":2,"featured_media":22238,"parent":0,"menu_order":4,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-23600","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/23600","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/comments?post=23600"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news\/23600\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media\/22238"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/media?parent=23600"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/de\/wp-json\/wp\/v2\/news_category?post=23600"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}