Product Categories

S-3000W series normal single switching power supply

WEHO S-3000 is a 3000W-class enclosed single-output family for engineered high-current DC loads, with a listed 200~264VAC input. Separate models provide 24V 0~125A, 27V 0~111A, 36V 0~83A or 48V 0~62.5A. Use it as a candidate for a defined DC equipment rail or load-test assembly, with exact-variant, wiring and thermal validation; neither the family wattage nor a current-range endpoint establishes continuous duty in every enclosure.

Εάν έχετε οποιεσδήποτε ερωτήσεις, μη διστάσετε να επικοινωνήσετε μαζί μας στο E-mail: [email protected]

Προσδιορισμός S-3000-24 S-3000-27 S-3000-36 S-3000-48
DC τάση εξόδου, ρεύμα 24V 0 ~ 125A 27V 0 ~ 111A 36V 0 ~ 83A 48V 0 ~ 62.5A
Κύμα και θόρυβος 240mVp-p 240mVp-p 300mVp-p 300mVp-p
Σταθερότητα καλωδίου εισόδου ±0,5% ±0,5% ±0,5% ±0,5%
Σταθερότητα φορτίου ±0,5% ±0,5% ±0,5% ±0,5%
Αποδοτικότητα 80% 82% 85% 87%
Ρυθμιζόμενο εύρος για τάση DC ±10% ±10% ±10% ±10%
Εύρος τάσης εισόδου 200 ~ 264VAC
Ρεύμα κρούσης Cold start current 70A/230VAC
Προστασία υπερφόρτωσης 105% ~ 135% cut off the output, automatic recovery
Προστασία από υπέρταση Not specified in this datasheet (overvoltage threshold and short-circuit recovery mode are not stated).
Ρύθμιση, άνοδος, χρόνος αναμονής 2000ms, 50ms, 20ms/230VAC at full load
Αντοχή στην τάση I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute
Αντοχή στην απομόνωση I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ
Θερμοκρασία εργασίας -10°C ~ +50°C
Διάσταση 291 × 132 × 136mm
Βάρος 5.3kg
Συσκευασία 38 × 37.5 × 21CM/2PCS/11kg

Why choose S-3000

A clear high-current selection set

S-3000-24, S-3000-27, S-3000-36 and S-3000-48 address different fixed-voltage loads. The 48V model lists a 62.5A upper endpoint; the choice is not four outputs from one unit or an interchangeable set of ratings.

A defined high-line input boundary

The input is listed as 200~264VAC. Confirm the actual frequency, input pin functions and branch protection; this sheet does not state a low-line selector, DC-input range or three-phase connection.

Mechanical planning before cabinet commitment

The table gives 291×132×136mm and 5.3kg. Verify the third-dimension reference, projecting output contacts and ventilation/service clearances against the actual unit before approving an enclosure drawing.

Substantial DC loading with a documented purpose

A high-current product-validation rig can warrant this power class where its DC demand is proven. A small status-board-only installation needs a separate sizing reason. The higher listed current makes conductor losses, joint heating and the continuous-duty assessment central to selection.

S-3000 features

Ripple/noise differs by voltage

The 24V and 27V columns list 240mVp-p; the 36V and 48V columns list 300mVp-p. Check the actual load’s tolerance and the measurement method instead of applying a lower family member’s noise figure.

Model-specific efficiency and stability

Line and load stability are each printed as ±0.5%. Efficiency entries are 80%, 82%, 85% and 87% in 24V, 27V, 36V and 48V order. The sheet does not provide the input, load and ambient conditions behind those efficiency figures.

Adjustment within an exact model

The adjustment entry is ±10% for each output. Validate device voltage tolerance, allowable current and heating at the intended setting; trim capability does not make the unit a programmable source or establish constant-power operation.

Automatic recovery after overload cut-off

The stated overload threshold is 105%~135%, with output cut-off and automatic recovery. Coordinate external protection and restart behaviour; do not infer additional protection functions or a permitted fault-duration rating.

S-3000 service conditions

Display-module upstream-circuit planning

A rugged display-module aging gantry must operate within 200~264VAC. Its listed cold-start current is 70A at 230VAC; do not replace it with the 45A value of another model or treat it as the running current. The proposed DC duty is compatible DC electronic inputs of a measured display-module batch, not the gantry handling drives. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.

Telecom distribution-unit fixture service

A telecommunications DC distribution-unit acceptance rig needs the exact output, cable routes, contact temperature limits and load sequence established first. The 0~125A, 0~111A, 0~83A and 0~62.5A ranges do not establish continuous fixture capability or a minimum-load requirement. The proposed DC duty is compatible fixed-voltage DC inputs of distribution units under test, with branch loading and bonding individually designed. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.

Camera-module test-compartment ventilation

An industrial camera-module soak-test carousel must allow fan access, terminations and service space around the complete unit. Working temperature is listed as −10°C~+50°C; there is no airflow specification or derating curve proving full load at the endpoints. The proposed DC duty is compatible DC inputs of camera modules in an aggregate batch; optical targets and measurement supplies are separately specified. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.

Signalling-module sequenced testing

A DC signalling-module production tower should accommodate setup 2000ms, rise 50ms and hold-up 20ms at 230VAC and full load. Verify behaviour with the intended loads and assess overload recovery separately from normal startup timing. The proposed DC duty is compatible signalling-module DC input branches; not signalling logic or a protective function. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.

S-3000 application considerations

Controller-assembly batch acceptance

A palletized controller-board acceptance machine may assess S-3000-24 for products specified to accept 24V DC. Confirm aggregate demand, startup current, switching noise and the continuous thermal allowance. Product motion outputs, regenerative loads, test instrumentation and the carrier drive remain separately engineered; the supply is not a precision programmable source. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.

Industrial DC blower-module qualification

An industrial DC blower-module qualification tunnel may evaluate a matching 24V or 48V S-3000 variant for documented product-side load demand. Verify start and stall current, switching transients, external protection and allowed duty before connection. The tunnel drive, facility ventilation and measurement equipment are separate; no airflow, efficiency or motor-control performance is claimed. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.

Machine-vision light-module batch checks

A machine-vision illuminator burn-in gantry may assess one matching 24V or 48V S-3000 output for fixed-voltage assemblies with a documented aggregate load. Confirm the module interface, branch protection and thermal duty. No constant-current LED driving, dimming, exposure synchronization or inspection accuracy is provided by implication; those functions need their own specified circuitry. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.

Industrial printer-mechanism batch tests

An industrial printer-mechanism assembly test conveyor may assess S-3000-24 for compatible 24V DC product inputs. Establish the batch load budget, start demand, harness losses and continuous duty before selection. Product functions and test sequences require independent controls; the conveyor drive, heaters and facility mains are not assigned to this supply. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.

S-3000 technical FAQs

Which exact output models are listed?

S-3000-24: 24V 0~125A; S-3000-27: 27V 0~111A; S-3000-36: 36V 0~83A; S-3000-48: 48V 0~62.5A. These are separate model choices, not simultaneous outputs. The lower bound of each printed range is zero; that alone does not establish minimum-load behaviour or a complete continuous-duty specification.

Does the 3000W class label guarantee continuous power in my enclosure?

No. The summary states 3000W for the family, while each output column has its own printed current range. The sheet does not define the continuous-load relationship to ambient temperature, airflow, mounting or adjustment. The printed ranges do not establish a continuous-power rating calculated from voltage times current.

What input range and selection method are documented?

The stated input is 200~264VAC. No input frequency, DC range, low-line switching band or three-phase connection is specified. Obtain the exact unit’s input connection details before installation.

What cold-start current must the upstream design consider?

The listed cold-start current is 70A at 230VAC. It is not a normal running-current figure and no second input condition is supplied. Coordinate the actual circuit and starting sequence rather than extrapolating this value to every input voltage.

What are the setup, rise and hold-up times?

Setup is 2000ms, rise is 50ms and hold-up is 20ms at 230VAC and full load, in that order. These values do not establish the response at another input voltage, a different load or during overload recovery.

What ripple/noise values should be used for selection?

S-3000-24: 240mVp-p; S-3000-27: 240mVp-p; S-3000-36: 300mVp-p; S-3000-48: 300mVp-p. Measurement bandwidth, probing and load conditions are not given. Validate compatibility with sensitive loads using the agreed test method.

How are stability and efficiency specified?

The line-stability and load-stability rows each print ±0.5% for all four models. S-3000-24: 80%; S-3000-27: 82%; S-3000-36: 85%; S-3000-48: 87%. Efficiency measurement conditions are not stated; these entries do not prove system-level heat rejection.

How much voltage adjustment is shown?

The visible table shows ±10% DC-voltage adjustment for each selected model. Check device voltage tolerance and permitted current at the chosen setting. Adjustment does not establish a programmable control interface, constant-power operation or interchangeability with another model.

What overload behaviour is stated?

The threshold is 105%~135%, with output cut-off and automatic recovery. No permissible fault duration, recovery waveform or additional short-circuit/overvoltage action is stated. Engineer external protection and safe restart independently.

What do the temperature and insulation entries establish?

Working temperature is listed as −10°C~+50°C without a derating curve or airflow requirement. Withstand values are 1.5kV input-to-output, 1.5kV input-to-frame and 0.5kV output-to-frame for one minute; AC/DC waveform is not specified. Isolation resistance is listed as 100MΩ at 500VDC for those pairs. These tests do not authorize a common-ground or output-strapping arrangement.

What mechanical and shipping information is available?

The table lists 291×132×136mm, 5.3kg and packing 38×37.5×21CM/2PCS/11kg. The drawing shows a 291mm chassis span, 132mm depicted face/span and 30mm post projection, but does not separately dimension the table’s 136mm extent. Verify mounting reference points, actual orientation, terminal clearances and service space before approving fit.

Can I wire the equipment from the outline drawing alone?

The input drawing has five screw symbols, with only the middle three numbered 1, 2 and 3; it provides no L/N/FG function legend. The output end shows POS(+)/+V, NEG(−)/−V and LED with additional contact symbols. Confirm the actual input functions, output-contact relationship, bonding, conductor sizes, torque and branch protection; do not infer strapping from the drawing.

Ποια είναι τα καλύτερα προϊόντα Power Supply για την επιχείρησή σας;

Ενισχύστε την επιχείρησή σας με ποιοτικά προϊόντα τροφοδοσίας WEHO.

Ρωτήστε έναν ειδικό
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.