- An inductive sensor's nominal range does not approve every metal thickness, finish or layered target.
- Identify the base metal, conductive layers, thickness and geometry of the actual production part.
- Compare controlled coupons before attributing a sensing change to plating alone.
- Validate both target-present and target-absent states within the permitted installation, then retain the accepted target specification.

Describe the metal structure before selecting by range
A metal name alone is an incomplete inductive sensing requirement when the target is foil, plated stock or a layered component. The base material, conducting layer, geometry and position can all change the detection task. Procurement should therefore retain a target drawing or sample specification alongside the sensor order.
Ο WEHO LJA18 family product information provides the appropriate starting point for identifying a candidate sensor. Match the complete suffix and applicable performance documents to the intended target. The product photograph does not establish a correction factor, minimum foil thickness or guaranteed distance for a plated part.
Consider a conveyor OEM that changes a metal flag's finish or substitutes a laminated label carrier. A successful test with the previous target does not automatically cover the replacement. The engineering question is whether the changed production target still provides the required output states throughout the allowed mechanical conditions.
Separate material, thickness and coating effects
An inductive sensor responds to the electromagnetic interaction with its target. Conductivity, magnetic properties and target geometry affect that interaction. A thin conducting sheet and a thick plate made from the same named metal should not be assumed to have interchangeable behavior.
OMRON's proximity sensor precautions discuss target material, size, thickness and plating separately. The examples include different outcomes for different base materials and plating systems. Those manufacturer-specific values demonstrate why the target construction matters; they are not numerical design limits for LJA18 sensors.
Distinguish a nonconducting paint layer from a conductive metallic coating. Paint can change the physical separation between the sensing face and the underlying metal, while a conductive layer can also participate in the electromagnetic response. A multilayer structure should be identified by its actual construction rather than treated as a thicker version of a single metal.
IFM's inductive technology overview explains the influence of target size, shape and material on sensing range. Use that principle to choose representative samples. Do not borrow another manufacturer's material factors or assume that a sensor with a similar diameter has the same response.

Build a coupon comparison that can support a decision
A useful coupon matrix changes one factor at a time where practical. Compare plated and unplated samples with the same base metal and dimensions to investigate finish. Evaluate a foil construction separately when its base material, thickness and support also change.
Record the coupon's relevant dimensions, layer stack and mounting method. A metal backing plate or nearby fixture can participate in detection and make an unsupported foil appear easier to sense. Use the intended support arrangement, or explicitly identify the difference between the coupon fixture and the final equipment.
A published Pepperl+Fuchs inductive sensor datasheet presents target-size curves tied to specified materials and a stated plate thickness. That is an example of condition-bound engineering data. It does not allow its graph to be reused for a WEHO sensor or for an arbitrarily thin target.
For the LJA18 review, ask which exact target and approach conditions were used for the applicable specification. Keep nominal sensing distance separate from the proposed working gap. If the actual target construction lies outside the available evidence, retain that gap and request a supported sample-evaluation method.
Screen the actual gap with a hypothetical example
Consider a hypothetical axial detection task, not a WEHO test result. The project places its target at a nominal 2.40 mm gap, with a combined allowed mechanical increase of 0.20 mm. The largest intended gap is therefore 2.40 + 0.20 = 2.60 mm.
Suppose a proposed sample study returns the minimum observed ON distance shown below, using the same sensor, approach direction and fixture. The two steel coupons share a base geometry; the foil assembly is a different target construction. The illustrative values exist only to explain the screening calculation.
| Hypothetical target | Minimum observed ON distance | Distance minus 2.60 mm gap | Initial interpretation |
|---|---|---|---|
| Unplated steel coupon | 3.40 mm | +0.80 mm | Positive observed distance difference |
| Matched plated steel coupon | 3.05 mm | +0.45 mm | Finish change requires its own retained record |
| Thin-foil assembly | 2.25 mm | −0.35 mm | Largest intended gap is beyond observed ON distance |
For the foil assembly, 2.25 − 2.60 = −0.35 mm. The stated observations do not support assuming detection at the largest project gap. Increasing sensitivity or moving the target may change the task, but neither change is automatically approved without repeating the applicable checks.
Swipe horizontally on a small screen, or open the full-size diagram.
For the plated coupon, the observed difference from the unplated sample is 3.40 − 3.05 = 0.35 mm. A controlled pair can support investigating that particular finish change. Comparing the steel and foil rows cannot isolate thickness alone because their material and construction also differ.
Positive differences in this table are not complete application approval. The study would still need adequate repetitions, relevant environmental conditions, replacement units, measurement capability and target-absent checks. A sampled minimum is an observation within the test, not a guaranteed production bound.
Test absence as well as presence
An acceptable target-present result must be paired with a correct target-absent state. Nearby guides, mounting metal, offcuts or a metal-backed support may produce a different result after the intended target leaves. Document those physical conditions instead of testing the coupon in an empty space that does not represent the equipment.
Retain the direction and path of movement. Axial approach, lateral passage and an angled foil edge are different sensing arrangements. Do not convert a distance observed on one path into a guaranteed edge-position result on another.
Ο WEHO aluminum-detection guide addresses the broader question of sensing a nonferrous material. Thin and layered target procurement adds construction control to that review. A “metal target accepted” note should therefore name the actual sample, finish and drawing revision.
Release a target-specific qualification record
- Identify the target construction. Record base metal, layer materials, thickness tolerances, dimensions and drawing revision. Accept a sample as representative only when its construction matches the intended production supply.
- Identify the sensor configuration. Retain the complete LJA18 label, suffix, mounting instructions and documented target conditions. Resolve missing information before assigning a target-specific working distance.
- Control the comparison. Record coupon support, surrounding metal, approach path and measurement method. Use matched samples to investigate one change, and label comparisons that change several variables.
- Check the operating envelope. Test required present and absent states across the approved mechanical and operating conditions. Judge results against project requirements rather than the nominal range alone.
- Preserve the accepted combination. Link sensor, target revision, settings and evidence in the release record. Reopen the review when a plating supplier, material thickness or support arrangement changes.
Send WEHO the real target specification
For an LJA18 sensing inquiry, provide the full sensor label, target drawing, material stack and required position range. Include samples or photographs that identify the construction without treating photographs as thickness measurements. Ask for applicable target data and a supported evaluation approach before approving the combination.
Frequently asked questions
Does an inductive sensor detect every metal at its nominal distance?
No. Nominal distance is associated with defined target and test conditions. Obtain the selected model's data and evaluate the actual target construction, position and installation.
Can plating be ignored because the base part is steel?
No. A conductive coating can affect sensing behavior, and a finish can also change geometry. Compare a controlled plated and unplated pair before attributing the effect or accepting a change.
Does one foil sample prove the whole material specification?
No. A sample observation covers its stated conditions. Qualification must account for the production construction, thickness range, mounting and other relevant variation before the result supports a release.
Can an external metal support invalidate a foil comparison?
Yes. A support within the sensing field can contribute to the response. Identify the complete fixture and repeat the assessment with the intended production support arrangement.