{"id":1079,"date":"2021-11-02T01:59:04","date_gmt":"2021-11-02T01:59:04","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=product&#038;p=1079"},"modified":"2026-11-11T19:00:12","modified_gmt":"2026-11-11T11:00:12","slug":"s-35w-series-normal-single-switching-power-supply","status":"publish","type":"product","link":"https:\/\/www.wehopower.com\/el\/product\/s-35w-series-normal-single-switching-power-supply\/","title":{"rendered":"S-35W series normal single switching power supply"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_tta-container\" data-vc-action=\"collapse\"><div class=\"vc_general vc_tta vc_tta-accordion vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-o-shape-group vc_tta-controls-align-default\"><div class=\"vc_tta-panels-container\"><div class=\"vc_tta-panels\"><div class=\"vc_tta-panel vc_active\" id=\"1636701172155-32719f5d-02c1\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1636701172155-32719f5d-02c1\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u03a0\u03c1\u03bf\u03b4\u03b9\u03b1\u03b3\u03c1\u03b1\u03c6\u03ad\u03c2 &amp; \u039c\u03bf\u03bd\u03c4\u03ad\u03bb\u03bf<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<table style=\"width: 100%;\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u03a0\u03c1\u03bf\u03c3\u03b4\u03b9\u03bf\u03c1\u03b9\u03c3\u03bc\u03cc\u03c2<\/td>\n<td style=\"text-align: center;\" width=\"66\">S-35-5<\/td>\n<td style=\"text-align: center;\" width=\"74\">S-35-12<\/td>\n<td style=\"text-align: center;\" width=\"86\">S-35-15<\/td>\n<td style=\"text-align: center;\" width=\"86\">S-35-24<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">DC \u03c4\u03ac\u03c3\u03b7 \u03b5\u03be\u03cc\u03b4\u03bf\u03c5, \u03c1\u03b5\u03cd\u03bc\u03b1<\/td>\n<td style=\"text-align: center;\" width=\"66\">5V 0\uff5e7A<\/td>\n<td style=\"text-align: center;\" width=\"74\">12V 0\uff5e3A<\/td>\n<td style=\"text-align: center;\" width=\"86\">15V 0\uff5e2.4A<\/td>\n<td style=\"text-align: center;\" width=\"86\">24V 0\uff5e1.5A<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u039a\u03cd\u03bc\u03b1 \u03ba\u03b1\u03b9 \u03b8\u03cc\u03c1\u03c5\u03b2\u03bf\u03c2<\/td>\n<td style=\"text-align: center;\" width=\"66\">70mVp-p<\/td>\n<td style=\"text-align: center;\" width=\"74\">100mVp-p<\/td>\n<td style=\"text-align: center;\" width=\"86\">100mVp-p<\/td>\n<td style=\"text-align: center;\" width=\"86\">100mVp-p<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u03a3\u03c4\u03b1\u03b8\u03b5\u03c1\u03cc\u03c4\u03b7\u03c4\u03b1 \u03ba\u03b1\u03bb\u03c9\u03b4\u03af\u03bf\u03c5 \u03b5\u03b9\u03c3\u03cc\u03b4\u03bf\u03c5<\/td>\n<td style=\"text-align: center;\" width=\"66\">\u00b10,5%<\/td>\n<td style=\"text-align: center;\" width=\"74\">\u00b10,5%<\/td>\n<td style=\"text-align: center;\" width=\"86\">\u00b10,5%<\/td>\n<td style=\"text-align: center;\" width=\"86\">\u00b10,5%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u03a3\u03c4\u03b1\u03b8\u03b5\u03c1\u03cc\u03c4\u03b7\u03c4\u03b1 \u03c6\u03bf\u03c1\u03c4\u03af\u03bf\u03c5<\/td>\n<td style=\"text-align: center;\" width=\"66\">\u00b11%<\/td>\n<td style=\"text-align: center;\" width=\"74\">\u00b10,5%<\/td>\n<td style=\"text-align: center;\" width=\"86\">\u00b10,5%<\/td>\n<td style=\"text-align: center;\" width=\"86\">\u00b10,5%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u0391\u03c0\u03bf\u03b4\u03bf\u03c4\u03b9\u03ba\u03cc\u03c4\u03b7\u03c4\u03b1<\/td>\n<td style=\"text-align: center;\" width=\"66\">70%<\/td>\n<td style=\"text-align: center;\" width=\"74\">76%<\/td>\n<td style=\"text-align: center;\" width=\"86\">78%<\/td>\n<td style=\"text-align: center;\" width=\"86\">78%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u03a1\u03c5\u03b8\u03bc\u03b9\u03b6\u03cc\u03bc\u03b5\u03bd\u03bf \u03b5\u03cd\u03c1\u03bf\u03c2 \u03b3\u03b9\u03b1 \u03c4\u03ac\u03c3\u03b7 DC<\/td>\n<td style=\"text-align: center;\" width=\"66\">\u00b110%<\/td>\n<td style=\"text-align: center;\" width=\"74\">\u00b110%<\/td>\n<td style=\"text-align: center;\" width=\"86\">\u00b110%<\/td>\n<td style=\"text-align: center;\" width=\"86\">\u00b110%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u0395\u03cd\u03c1\u03bf\u03c2 \u03c4\u03ac\u03c3\u03b7\u03c2 \u03b5\u03b9\u03c3\u03cc\u03b4\u03bf\u03c5<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">90~132VAC\/180~264VAC by switch 254\uff5e370VDC 47\uff5e63Hz<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u03a1\u03b5\u03cd\u03bc\u03b1 \u03ba\u03c1\u03bf\u03cd\u03c3\u03b7\u03c2<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">Cold start current 18A\/115VAC 36A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u03a0\u03c1\u03bf\u03c3\u03c4\u03b1\u03c3\u03af\u03b1 \u03c5\u03c0\u03b5\u03c1\u03c6\u03cc\u03c1\u03c4\u03c9\u03c3\u03b7\u03c2<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">105%\uff5e150% \u03b4\u03b9\u03b1\u03ba\u03cc\u03c0\u03c4\u03b5\u03b9 \u03c4\u03b7\u03bd \u03ad\u03be\u03bf\u03b4\u03bf, \u03b1\u03c5\u03c4\u03cc\u03bc\u03b1\u03c4\u03b7 \u03b1\u03bd\u03ac\u03ba\u03c4\u03b7\u03c3\u03b7<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u03a0\u03c1\u03bf\u03c3\u03c4\u03b1\u03c3\u03af\u03b1 \u03b1\u03c0\u03cc \u03c5\u03c0\u03ad\u03c1\u03c4\u03b1\u03c3\u03b7<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">115% ~ 135% shut down O\/P voltage, re-power on to recover<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u03a1\u03cd\u03b8\u03bc\u03b9\u03c3\u03b7, \u03ac\u03bd\u03bf\u03b4\u03bf\u03c2, \u03c7\u03c1\u03cc\u03bd\u03bf\u03c2 \u03b1\u03bd\u03b1\u03bc\u03bf\u03bd\u03ae\u03c2<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">200ms,100ms,30ms\/230VAC at full load<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u0391\u03bd\u03c4\u03bf\u03c7\u03ae \u03c3\u03c4\u03b7\u03bd \u03c4\u03ac\u03c3\u03b7<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">I\/P-O\/P:1,5kV I\/P-FG:1,5kV O\/P-FG:0,5kV 1 \u03bb\u03b5\u03c0\u03c4\u03cc<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u0391\u03bd\u03c4\u03bf\u03c7\u03ae \u03c3\u03c4\u03b7\u03bd \u03b1\u03c0\u03bf\u03bc\u03cc\u03bd\u03c9\u03c3\u03b7<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">I\/P-O\/P I\/P-FG O\/P-FG:500VDC\/100M\u03a9<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u0398\u03b5\u03c1\u03bc\u03bf\u03ba\u03c1\u03b1\u03c3\u03af\u03b1 \u03b5\u03c1\u03b3\u03b1\u03c3\u03af\u03b1\u03c2<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">-10\u2103~+50\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u0394\u03b9\u03ac\u03c3\u03c4\u03b1\u03c3\u03b7<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">129\u00d798\u00d738mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u0392\u03ac\u03c1\u03bf\u03c2<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">0.4kg<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"210\" height=\"19\">\u03a3\u03c5\u03c3\u03ba\u03b5\u03c5\u03b1\u03c3\u03af\u03b1<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"312\">43\u00d732.5\u00d724CM\/45PCS\/18kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"1636701110045-2231239d-d5c7\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1636701110045-2231239d-d5c7\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u03a3\u03c7\u03ad\u03b4\u03b9\u03bf<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left wpb_content_element\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimensionmm-s-35-1024x260.jpg\" target=\"_self\" class=\"vc_single_image-wrapper   vc_box_border_grey\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1220\" height=\"310\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimensionmm-s-35.jpg\" class=\"vc_single_image-img attachment-full\" alt=\"Overall dimensionmm s 35\" title=\"Overall dimensionmm s 35\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimensionmm-s-35.jpg 1220w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimensionmm-s-35-300x76.jpg 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimensionmm-s-35-1024x260.jpg 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimensionmm-s-35-768x195.jpg 768w\" sizes=\"(max-width: 1220px) 100vw, 1220px\" style=\"width:100%;height:25.41%;max-width:1220px;\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"1636701110038-e7dfe23b-653a\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1636701110038-e7dfe23b-653a\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u03a7\u03b1\u03c1\u03b1\u03ba\u03c4\u03b7\u03c1\u03b9\u03c3\u03c4\u03b9\u03ba\u03ac<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Why Choose the S-35?<\/h2>\n<h3>Select the exact electronic supply requirement<\/h3>\n<p>The options range from S-35-5 at 5V 0~7A to S-35-24 at 24V 0~1.5A, with separate 12V and 15V variants. Match the board voltage first, then assess startup and continuous demand. The four columns are not simultaneous outputs or a selectable multi-voltage unit.<\/p>\n<h3>Include the stated inrush pair in upstream design<\/h3>\n<p>The S-35 cold-start row gives 18A\/115VAC and 36A\/230VAC. Assess upstream switching at the stated input-voltage conditions. Verify switch, protective-device and equipment-startup behavior for the real installation.<\/p>\n<h3>Check sensitive 5V loads against their own figures<\/h3>\n<p>S-35-5 lists 70mVp-p ripple, \u00b10.5% line stability and \u00b11% load stability. The other outputs list 100mVp-p ripple and \u00b10.5% load stability. A counter or communication board needs the figures for its ordered suffix, not a family-wide best case.<\/p>\n<h3>Evaluate service access around the 129mm outline<\/h3>\n<p>Use the 129\u00d798\u00d738mm outline to plan mounting, terminal access and service space. Establish the required barriers and thermal clearance for the complete equipment. A related family name or similar photograph does not establish drop-in replacement compatibility.<\/p>\n<h2>S-35 Features<\/h2>\n<h3>Model-bound output current ranges<\/h3>\n<p>S-35-5 lists 5V 0~7A; S-35-12 lists 12V 0~3A; S-35-15 lists 15V 0~2.4A; S-35-24 lists 24V 0~1.5A. The 35W family designation and printed current ranges do not define the complete continuous operating envelope.<\/p>\n<h3>Voltage adjustment is not current control<\/h3>\n<p>All four variants list \u00b110% DC-voltage adjustment and \u00b10.5% line stability. Set the voltage only within the connected board\u2019s limits and the accepted model duty. The entry does not establish constant-current operation, dimming or battery charging.<\/p>\n<h3>Manual input selection with conditioned timing<\/h3>\n<p>The AC bands are 90~132VAC\/180~264VAC by switch, with 254~370VDC and 47~63Hz also listed. Setup, rise and hold-up are 200ms, 100ms and 30ms at 230VAC and full load. Neither entry removes the need to verify the delivered unit\u2019s setting and connection instructions.<\/p>\n<h3>Different recovery paths for different faults<\/h3>\n<p>The overload range is 105%~150%, cutting off output with automatic recovery. Overvoltage is 115%~135%, shutting down output and requiring re-powering. These protective responses do not approve sustained overload or replace a complete equipment protection design.<\/p>\n<h2>Typical Service Conditions<\/h2>\n<h3>Keep textile dust outside an edge-guide display bay<\/h3>\n<p>An edge-guide display bay may evaluate a qualified S-35 output for compatible indication and interface electronics. Keep fibres away from the electrical compartment and assess its actual temperature. Web-guiding actuators, drives and alignment accuracy remain separate system functions.<\/p>\n<h3>Control wiring around a resistance-weld monitoring console<\/h3>\n<p>A weld-monitoring console needs segregation from high-current weld conductors and verification of noise at its electronic loads. S-35 would be assessed only for accepted local monitor electronics. It is not the weld source and does not establish welding performance or immunity of the finished monitor.<\/p>\n<h3>Protect a vacuum-leak instrument rack from process exposure<\/h3>\n<p>A vacuum-leak instrument rack should keep the supply in a dry, protected electrical section. Validate thermal conditions and the exact output\u2019s demand. Vacuum pumps, gauges requiring special excitation and calibrated leak-rate measurement need separately accepted equipment.<\/p>\n<h3>Assess startup in a sachet-seal controller compartment<\/h3>\n<p>A sachet-seal controller may change its electronic demand during startup and diagnostics. Test the selected S-35 output with the real control boards and safe reset policy. Seal heaters, feed motors and cutting actuators are not covered by this local electronic-load concept.<\/p>\n<h2>Potential S-35 Applications<\/h2>\n<h3>Industrial punch-counting panel<\/h3>\n<p>A punch-counting panel may assess a selected output for compatible counter, display and communication boards. Confirm actual duty and signal-interface noise. Press actuation, clutch power and operator protection must remain independently supplied and qualified.<\/p>\n<h3>Bearing-temperature acquisition station<\/h3>\n<p>Evaluate an exact S-35 model for compatible local data-acquisition electronics after checking voltage and ripple tolerance. Temperature-sensor excitation, channel isolation, calibration and any machine trip are separate requirements. The supply alone does not establish measurement accuracy.<\/p>\n<h3>Carton dimension indicator<\/h3>\n<p>A carton dimension indicator may consider an accepted output for compatible display and interface electronics in a protected cabinet. Confirm the actual boards and interruption response. Optical emitters, conveyor motors and dimensional measurement performance require independent validation.<\/p>\n<h3>Air-filter differential-pressure logger<\/h3>\n<p>Consider a qualified S-35 version for compatible logger and communication electronics. Keep the electrical compartment away from moisture and contamination, and verify the selected voltage. Pressure sensing, channel isolation and a protective filter alarm are not established by the supply specification.<\/p>\n<h2>S-35 Technical FAQs<\/h2>\n<h3>Which exact output models and current ranges are listed?<\/h3>\n<p>S-35-5 lists 5V 0~7A; S-35-12 lists 12V 0~3A; S-35-15 lists 15V 0~2.4A; S-35-24 lists 24V 0~1.5A. They are alternative single-output models, not four simultaneous rails.<\/p>\n<h3>Does the 35W designation approve every continuous operating point?<\/h3>\n<p>The family designation and printed current ranges are separate entries. Do not calculate a replacement continuous wattage from their endpoints or assume maximum output at every input and temperature. Confirm the ordered suffix\u2019s continuous and startup duty; the printed zero lower bounds do not independently establish minimum-load or no-load acceptance.<\/p>\n<h3>Is the AC input automatically selected?<\/h3>\n<p>The sheet states 90~132VAC\/180~264VAC by switch, plus 254~370VDC and 47~63Hz. Select the correct AC band before energizing; this is not automatic range selection. Confirm separate DC-input connection instructions before DC use.<\/p>\n<h3>What does the voltage-adjustment entry establish?<\/h3>\n<p>Each model lists \u00b110% DC-voltage adjustment. It does not establish regulated-current output, dimming, arbitrary programmable operation or battery charging. Confirm the adjustment procedure, connected load voltage limits and accepted operating envelope before using a changed setting.<\/p>\n<h3>What ripple and line\/load stability apply to each output?<\/h3>\n<p>S-35-5: 70mVp-p; S-35-12: 100mVp-p; S-35-15: 100mVp-p; S-35-24: 100mVp-p. All four list \u00b10.5% line stability; the 5V version lists \u00b11% load stability and the other outputs \u00b10.5%. No ripple measurement bandwidth or wiring method is specified by these entries.<\/p>\n<h3>Which efficiencies and cold-start values belong to this model?<\/h3>\n<p>Efficiencies in S-35-5, S-35-12, S-35-15, S-35-24 order are 70%, 76%, 78%, 78%. Cold-start current is 18A\/115VAC and 36A\/230VAC. Efficiency depends on the selected output; each cold-start value applies to its stated input voltage and is not a continuous input-current rating.<\/p>\n<h3>How does overload protection recover?<\/h3>\n<p>The overload entry is 105%~150%, cutting off the output with automatic recovery. This is not a continuous overload allowance or a replacement for cable and branch protection. Evaluate the connected electronics\u2019 behavior during repeated power loss and recovery as part of the equipment design.<\/p>\n<h3>Does overvoltage shutdown recover automatically?<\/h3>\n<p>The overvoltage entry is 115%~135%, shutting down the output voltage and requiring re-powering to recover. Keep this separate from automatic overload recovery. Safe restart and downstream protection need their own equipment-level verification.<\/p>\n<h3>Which setup, rise and hold-up values and conditions are specified?<\/h3>\n<p>Setup, rise and hold-up are 200ms, 100ms and 30ms at 230VAC and full load. The stated input and full-load conditions apply to this timing entry. Full-load timing does not establish full load throughout the temperature range or identical response at every input and load.<\/p>\n<h3>What working temperature, dimensions and mass are listed?<\/h3>\n<p>The values are -10\u00b0C~+50\u00b0C, 129\u00d798\u00d738mm and 0.4kg. Check actual mounting, terminal access, service clearance and local thermal conditions. These entries do not provide an ingress rating, humidity specification or complete full-load derating curve.<\/p>\n<h3>What withstand and isolation-resistance entries are printed?<\/h3>\n<p>The withstand row lists I\/P-O\/P 1.5kV, I\/P-FG 1.5kV and O\/P-FG 0.5kV for 1 minute, without an AC\/DC qualifier. Isolation resistance is listed as 500VDC\/100M\u03a9 for the named input\/output\/frame-ground pairs. These component test entries do not establish certification scope or finished-equipment approval.<\/p>\n<h3>What terminal order is shown, and can it be transferred between models?<\/h3>\n<p>The S-35 legend labels pins 1 and 2 as AC input, pin 3 as GND, pin 4 as DC output-V and pin 5 as DC output+V. Confirm the exact delivered unit, terminal markings and connection instructions before wiring, including a proposed DC-input application. Similar enclosures do not authorize transferring another model\u2019s wiring.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"Specifications&amp;Model Specification S-35-5 S-35-12 S-35-15 S-35-24 DC output voltage,current 5V 0\uff5e7A 12V 0\uff5e3A 15V 0\uff5e2.4A 24V 0\uff5e1.5A Wave and noise 70mVp-p 100mVp-p 100mVp-p 100mVp-p Inlet wire stability \u00b10.5% \u00b10.5% \u00b10.5% \u00b10.5% Load stability \u00b11% \u00b10.5% \u00b10.5% \u00b10.5% Efficiency 70% 76% 78% 78% Adjustable range for DC voltage \u00b110% \u00b110% \u00b110% \u00b110% Input voltage range 90~132VAC\/180~264VAC&hellip; <a class=\"more-link\" href=\"https:\/\/www.wehopower.com\/el\/product\/s-35w-series-normal-single-switching-power-supply\/\">\u03a3\u03c5\u03bd\u03b5\u03c7\u03af\u03c3\u03c4\u03b5 \u03c4\u03b7\u03bd \u03b1\u03bd\u03ac\u03b3\u03bd\u03c9\u03c3\u03b7 <span class=\"screen-reader-text\">S-35W series normal single switching power supply<\/span><\/a>","protected":false},"author":1,"featured_media":21137,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[35,36],"product_categories_new":[126],"class_list":["post-1079","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-enclosed-switching-power-supply","product_category-s-series-single-output-power-supply","product_categories_new-s-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product\/1079","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/comments?post=1079"}],"version-history":[{"count":2,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product\/1079\/revisions"}],"predecessor-version":[{"id":21701,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product\/1079\/revisions\/21701"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/media\/21137"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/media?parent=1079"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product_category?post=1079"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product_categories_new?post=1079"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}