{"id":4889,"date":"2023-04-11T08:24:00","date_gmt":"2023-04-11T08:24:00","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=product&#038;p=4889"},"modified":"2026-11-14T12:38:25","modified_gmt":"2026-11-14T04:38:25","slug":"high-efficiency-30w-single-output-power-supply","status":"publish","type":"product","link":"https:\/\/www.wehopower.com\/el\/product\/high-efficiency-30w-single-output-power-supply\/","title":{"rendered":"HDR-30 Series 30W Ultra Slim Step Shape DIN Rail Power Supply (HDR-30-12 \/ HDR-30-24)"},"content":{"rendered":"<p>&nbsp;<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"20%\">\u039c\u03bf\u03bd\u03c4\u03ad\u03bb\u03bf<\/td>\n<td width=\"20%\">HDR-30-5<\/td>\n<td width=\"20%\">HDR-30-12<\/td>\n<td width=\"20%\">HDR-30-24<\/td>\n<td width=\"20%\">HDR-30-48<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">DC output voltage, current<\/td>\n<td width=\"20%\">5V 0~3A<\/td>\n<td width=\"20%\">12V 0~2A<\/td>\n<td width=\"20%\">24V 0~1.5A<\/td>\n<td width=\"20%\">48V 0~0.75A<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u039a\u03cd\u03bc\u03b1 \u03ba\u03b1\u03b9 \u03b8\u03cc\u03c1\u03c5\u03b2\u03bf\u03c2<\/td>\n<td width=\"20%\">80mVp-p<\/td>\n<td width=\"20%\">120mVp-p<\/td>\n<td width=\"20%\">150mVp-p<\/td>\n<td width=\"20%\">240mVp-p<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">Inlet wire Stability<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u03a3\u03c4\u03b1\u03b8\u03b5\u03c1\u03cc\u03c4\u03b7\u03c4\u03b1 \u03c6\u03bf\u03c1\u03c4\u03af\u03bf\u03c5<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u0391\u03c0\u03bf\u03b4\u03bf\u03c4\u03b9\u03ba\u03cc\u03c4\u03b7\u03c4\u03b1<\/td>\n<td width=\"20%\">80%<\/td>\n<td width=\"20%\">86%<\/td>\n<td width=\"20%\">87%<\/td>\n<td width=\"20%\">87%<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">Adjustable Range for DC Voltage<\/td>\n<td width=\"20%\">\u00b110%<\/td>\n<td width=\"20%\">\u00b110%<\/td>\n<td width=\"20%\">\u00b110%<\/td>\n<td width=\"20%\">\u00b110%<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u0395\u03cd\u03c1\u03bf\u03c2 \u03c4\u03ac\u03c3\u03b7\u03c2 \u03b5\u03b9\u03c3\u03cc\u03b4\u03bf\u03c5<\/td>\n<td colspan=\"4\" width=\"80%\">85~264VAC; 120~370VDC; 47~63Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u03a1\u03b5\u03cd\u03bc\u03b1 \u03b5\u03c0\u03b9\u03c1\u03c1\u03bf\u03ae\u03c2<\/td>\n<td colspan=\"4\" width=\"80%\">Cold start current: 25A\/115VAC; 45A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u03a0\u03c1\u03bf\u03c3\u03c4\u03b1\u03c3\u03af\u03b1 \u03c5\u03c0\u03b5\u03c1\u03c6\u03cc\u03c1\u03c4\u03c9\u03c3\u03b7\u03c2<\/td>\n<td colspan=\"4\" width=\"80%\">105%\uff5e150% cut off the output, automatic recovery<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u03a0\u03c1\u03bf\u03c3\u03c4\u03b1\u03c3\u03af\u03b1 \u03b1\u03c0\u03cc \u03c5\u03c0\u03ad\u03c1\u03c4\u03b1\u03c3\u03b7<\/td>\n<td colspan=\"4\" width=\"80%\">115%\uff5e140% rated output power. Protection type: Hiccups mode, recovers automatically after fault condition is removed<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">Setup, Rise, Hold Up Time<\/td>\n<td colspan=\"4\" width=\"80%\">1500ms, 80ms\/230VAC; 1500ms, 80ms\/115VAC (at full load)<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u0391\u03bd\u03c4\u03bf\u03c7\u03ae \u03c4\u03ac\u03c3\u03b7\u03c2<\/td>\n<td colspan=\"4\" width=\"80%\">I\/P-O\/P: 1.5kV; I\/P-FG: 1.5kV; O\/P-FG: 0.5kV; 1 minute<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u0391\u03bd\u03c4\u03af\u03c3\u03c4\u03b1\u03c3\u03b7 \u03b1\u03c0\u03bf\u03bc\u03cc\u03bd\u03c9\u03c3\u03b7\u03c2<\/td>\n<td colspan=\"4\" width=\"80%\">I\/P-O\/P, I\/P-FG, O\/P-FG: 100M\u03a9 \/ 500VDC \/ 25\u2103 \/ 70%RH<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u0398\u03b5\u03c1\u03bc\u03bf\u03ba\u03c1\u03b1\u03c3\u03af\u03b1 \u03b5\u03c1\u03b3\u03b1\u03c3\u03af\u03b1\u03c2<\/td>\n<td colspan=\"4\" width=\"80%\">-20\u2103\uff5e+70\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u0394\u03b9\u03ac\u03c3\u03c4\u03b1\u03c3\u03b7<\/td>\n<td colspan=\"4\" width=\"80%\">35\u00d790\u00d754.5mm<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\u0392\u03ac\u03c1\u03bf\u03c2<\/td>\n<td colspan=\"4\" width=\"80%\">0.12kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why choose the HDR-30 DIN-rail power supply?<\/h2>\n<h3>Compact panel integration<\/h3>\n<p>The documented 35 \u00d7 90 \u00d7 54.5mm dimensions provide a concrete starting point for allocating DIN-rail space. Check the complete mechanical drawing and the space required by wiring and nearby equipment.<\/p>\n<h3>Four distinct DC voltage choices<\/h3>\n<p>HDR-30-5, HDR-30-12, HDR-30-24 and HDR-30-48 are separate single-output versions. Choose the version that matches the connected electronics rather than treating the four voltages as simultaneous outputs.<\/p>\n<h3>Broad documented input ranges<\/h3>\n<p>The specified input ranges are 85\u2013264VAC and 120\u2013370VDC, with an AC frequency range of 47\u201363Hz. Confirm the actual installation supply and the requirements of the selected revision.<\/p>\n<h3>Defined overload recovery<\/h3>\n<p>The specified overload range is 105%\u2013150%, with output cut-off and automatic recovery. Coordinate the load and fault response so an overloaded circuit is not treated as normal continuous operation.<\/p>\n<h2>Feature of 30W Industrial DIN Rail Single Output Power Supply<\/h2>\n<h3>Model-specific output selection<\/h3>\n<p>The output table lists 5V 0\u20133A, 12V 0\u20132A, 24V 0\u20131.5A and 48V 0\u20130.75A for the respective models. Use the exact variant&#x27;s voltage and current data for load selection; the family name is not a uniform continuous-power rating for every output option.<\/p>\n<h3>Documented regulation and adjustment<\/h3>\n<p>Line regulation and load regulation are each listed as \u00b11% for all four models. The DC voltage adjustment range is \u00b110%; confirm the connected equipment&#x27;s allowable input before adjustment.<\/p>\n<h3>Variant-specific ripple and efficiency<\/h3>\n<p>The respective ripple\/noise values are 80, 120, 150 and 240mVp-p; the respective efficiency values are 80%, 86%, 87% and 87%. Compare the exact model&#x27;s figures with the application&#x27;s noise and power-budget requirements.<\/p>\n<h3>Published electrical and mechanical interfaces<\/h3>\n<p>The terminal drawing identifies pin 1 as +V, pin 2 as \u2212V, pin 3 as AC\/L and pin 4 as AC\/N. Admissible DIN rails are TS35\/7.5 or TS35\/15. Follow the mechanical drawing and the installation&#x27;s electrical-safety requirements.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-4890\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-30-size.jpg\" alt=\"HDR-30 size\" width=\"2038\" height=\"623\" title=\"\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-30-size.jpg 2038w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-30-size-300x92.jpg 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-30-size-1024x313.jpg 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-30-size-768x235.jpg 768w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-30-size-1536x470.jpg 1536w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-30-size-1568x479.jpg 1568w\" sizes=\"(max-width: 2038px) 100vw, 2038px\" \/><\/p>\n<h2>Typical service conditions<\/h2>\n<h3>Cabinet layout and rail fit<\/h3>\n<p>Plan around the 35 \u00d7 90 \u00d7 54.5mm body and the specified TS35\/7.5 or TS35\/15 rail. Allow for terminal access, wire routing and the surrounding equipment; the dimensional drawing is not a universal clearance requirement.<\/p>\n<h3>Input supply and output polarity<\/h3>\n<p>Check the 85\u2013264VAC or 120\u2013370VDC input range against the actual source. The terminal drawing labels AC\/L and AC\/N separately from +V and \u2212V. Confirm DC-input wiring for the selected unit rather than assuming that AC terminal labels alone define every DC installation.<\/p>\n<h3>Temperature and continuous-load planning<\/h3>\n<p>The stated working-temperature range is \u221220\u00b0C to +70\u00b0C. Evaluate the selected voltage\/current version in the real enclosure and airflow conditions; this temperature range alone does not establish full-output operation at every ambient temperature.<\/p>\n<h3>Noise, start-up and fault coordination<\/h3>\n<p>Check the selected model&#x27;s ripple\/noise against the electronics being powered. The timing row lists 1500ms and 80ms at 230VAC and again at 115VAC, with a full-load condition. Coordinate downstream start-up and fault protection with the actual equipment.<\/p>\n<h2>Application guidance<\/h2>\n<p>The following are potential integration roles, not customer-installation claims. Match the exact DC voltage, steady-state current, start-up demand and environmental requirements of the equipment before selection.<\/p>\n<h3>Access-control electronics<\/h3>\n<p>Supply compatible reader, controller or interface electronics inside a protected access-control panel. Check the exact electronics input; door strikes, motors and other pulsed loads require their own load and protection assessment.<\/p>\n<h3>Process sensing and monitoring<\/h3>\n<p>Provide local DC power to compatible sensor interfaces, monitoring modules or compact indication electronics. Confirm the required supply voltage and current and compare the model&#x27;s ripple\/noise with the measurement-system requirements.<\/p>\n<h3>Building-automation control panels<\/h3>\n<p>Support compatible zone-controller or building-management interface electronics in a protected panel. Check panel temperature, available rail space and the connected devices&#x27; input limits; the supply alone does not establish outdoor or system-level approval.<\/p>\n<h3>Industrial communications interfaces<\/h3>\n<p>Power compatible gateways, serial-interface modules or local communications electronics with a matching DC input. Verify the complete load budget and start-up demand; selecting HDR-30 does not add PoE, backup or UPS functions.<\/p>\n<h2>HDR-30 technical FAQs<\/h2>\n<h3>Which DC output versions are listed for HDR-30?<\/h3>\n<p>The listed models are HDR-30-5, HDR-30-12, HDR-30-24 and HDR-30-48, providing nominal 5V, 12V, 24V and 48V outputs respectively. Each is a single-output version.<\/p>\n<h3>What output-current ranges are specified for the four versions?<\/h3>\n<p>The table specifies 0\u20133A at 5V, 0\u20132A at 12V, 0\u20131.5A at 24V and 0\u20130.75A at 48V. Keep each current range with its own model; do not substitute a common current or power limit across the four versions.<\/p>\n<h3>What input-voltage and frequency ranges are specified?<\/h3>\n<p>The input-voltage ranges are 85\u2013264VAC and 120\u2013370VDC. The AC frequency range is 47\u201363Hz. Confirm the selected unit and the installation requirements before connection.<\/p>\n<h3>What line-regulation and load-regulation figures are listed?<\/h3>\n<p>Line regulation and load regulation are each listed as \u00b11% for every HDR-30 output version.<\/p>\n<h3>What DC voltage adjustment range is listed?<\/h3>\n<p>The table lists a \u00b110% DC voltage adjustment range for each version. Check the load&#x27;s allowable input range before changing the output setting.<\/p>\n<h3>What ripple\/noise values are listed?<\/h3>\n<p>The values are 80mVp-p for HDR-30-5, 120mVp-p for HDR-30-12, 150mVp-p for HDR-30-24 and 240mVp-p for HDR-30-48. Confirm any application-specific measurement conditions separately.<\/p>\n<h3>What efficiency values are listed?<\/h3>\n<p>The listed efficiency values are 80% for HDR-30-5, 86% for HDR-30-12, and 87% for both HDR-30-24 and HDR-30-48. Use the figure for the selected voltage version.<\/p>\n<h3>What cold-start inrush-current figures are specified?<\/h3>\n<p>Cold-start current is listed as 25A at 115VAC and 45A at 230VAC. Keep the two values tied to their stated input voltages when assessing upstream protection.<\/p>\n<h3>How is overload recovery specified?<\/h3>\n<p>Overload protection is listed at 105%\u2013150%, with the output cut off and automatic recovery. Verify the response with the actual load and do not use the protection range as a normal continuous operating rating.<\/p>\n<h3>What timing information is provided for HDR-30?<\/h3>\n<p>The timing row prints 1500ms and 80ms at 230VAC, and 1500ms and 80ms at 115VAC, with a full-load condition. It does not print a separate third hold-up-time value.<\/p>\n<h3>What temperature range and body dimensions are stated?<\/h3>\n<p>The working-temperature range is \u221220\u00b0C to +70\u00b0C. Body dimensions are 35 \u00d7 90 \u00d7 54.5mm and weight is 0.12kg. Confirm thermal performance for the actual load and enclosure rather than assuming full output at every temperature.<\/p>\n<h3>Which terminal assignments and DIN rails are shown?<\/h3>\n<p>The drawing identifies pin 1 as +V, pin 2 as \u2212V, pin 3 as AC\/L and pin 4 as AC\/N. The admissible DIN rails are TS35\/7.5 and TS35\/15. Use the complete drawing and installation instructions for final integration.<\/p>","protected":false},"excerpt":{"rendered":"<p>HDR-30W Single Output Power Supply is suitable for communication and networking equipment, as well as industrial control systems. <\/p>","protected":false},"author":1,"featured_media":21074,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[45,80],"product_categories_new":[116],"class_list":["post-4889","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-din-rail-power-supply","product_category-hdr-series-din-rail-power-supply","product_categories_new-hdr-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product\/4889","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/comments?post=4889"}],"version-history":[{"count":6,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product\/4889\/revisions"}],"predecessor-version":[{"id":22016,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product\/4889\/revisions\/22016"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/media\/21074"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/media?parent=4889"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product_category?post=4889"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product_categories_new?post=4889"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}