{"id":782,"date":"2021-11-01T02:14:38","date_gmt":"2021-11-01T02:14:38","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=product&#038;p=782"},"modified":"2026-11-05T16:45:48","modified_gmt":"2026-11-05T08:45:48","slug":"original-weho-60w-triple-output-5v-12v-24v-switching-power-supply","status":"publish","type":"product","link":"https:\/\/www.wehopower.com\/el\/product\/original-weho-60w-triple-output-5v-12v-24v-switching-power-supply\/","title":{"rendered":"WEHO T-60W triple output power supply \u2014 T-60A \/ T-60B \/ T-60C \/ T-60D"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_tta-container\" data-vc-action=\"collapse\"><div class=\"vc_general vc_tta vc_tta-accordion vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-o-shape-group vc_tta-controls-align-default\"><div class=\"vc_tta-panels-container\"><div class=\"vc_tta-panels\"><div class=\"vc_tta-panel vc_active\" id=\"1636701172155-32719f5d-02c1\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1636701172155-32719f5d-02c1\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u03a0\u03c1\u03bf\u03b4\u03b9\u03b1\u03b3\u03c1\u03b1\u03c6\u03ad\u03c2 &amp; \u039c\u03bf\u03bd\u03c4\u03ad\u03bb\u03bf<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<table width=\"100%\">\n<tbody>\n<tr>\n<td rowspan=\"2\">\u039c\u03bf\u03bd\u03c4\u03ad\u03bb\u03bf<\/td>\n<td colspan=\"3\">T-60A<\/td>\n<td colspan=\"3\">T-60B<\/td>\n<td colspan=\"3\">T-60C<\/td>\n<td colspan=\"3\">T-60D<\/td>\n<\/tr>\n<tr>\n<td>CH1<\/td>\n<td>CH2<\/td>\n<td>CH3<\/td>\n<td>CH1<\/td>\n<td>CH2<\/td>\n<td>CH3<\/td>\n<td>CH1<\/td>\n<td>CH2<\/td>\n<td>CH3<\/td>\n<td>CH1<\/td>\n<td>CH2<\/td>\n<td>CH3<\/td>\n<\/tr>\n<tr>\n<td>\u03a4\u03ac\u03c3\u03b7 \u03b5\u03be\u03cc\u03b4\u03bf\u03c5 DC<\/td>\n<td>5V<\/td>\n<td>12V<\/td>\n<td>-5V<\/td>\n<td>5V<\/td>\n<td>12V<\/td>\n<td>-12V<\/td>\n<td>5V<\/td>\n<td>15V<\/td>\n<td>-15V<\/td>\n<td>5V<\/td>\n<td>12V<\/td>\n<td>24 (unit not printed; verification required)<\/td>\n<\/tr>\n<tr>\n<td>Output voltage tolerance (not separately stated)<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<\/tr>\n<tr>\n<td>Rated output current (not separately stated)<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<\/tr>\n<tr>\n<td>Output current range (as printed)<\/td>\n<td>0 ~ 5A<\/td>\n<td>0 ~ 2.5A<\/td>\n<td>0 ~ 0.5A<\/td>\n<td>0 ~ 5A<\/td>\n<td>0 ~ 2.5A<\/td>\n<td>0 ~ 0.5A<\/td>\n<td>0 ~ 5A<\/td>\n<td>0 ~ 2A<\/td>\n<td>0 ~ 0.5A<\/td>\n<td>0.5 ~ 5A<\/td>\n<td>0.2 ~ 2.5A<\/td>\n<td>0.2 ~ 0.5A<\/td>\n<\/tr>\n<tr>\n<td>\u039a\u03cd\u03bc\u03b1 \u03ba\u03b1\u03b9 \u03b8\u03cc\u03c1\u03c5\u03b2\u03bf\u03c2<\/td>\n<td>50mVp-p<\/td>\n<td>100mVp-p<\/td>\n<td>100mVp-p<\/td>\n<td>100mVp-p<\/td>\n<td>120mVp-p<\/td>\n<td>120mVp-p<\/td>\n<td>100mVp-p<\/td>\n<td>120mVp-p<\/td>\n<td>120mVp-p<\/td>\n<td>80mVp-p<\/td>\n<td>100mVp-p<\/td>\n<td>100mVp-p<\/td>\n<\/tr>\n<tr>\n<td>\u03a3\u03c4\u03b1\u03b8\u03b5\u03c1\u03cc\u03c4\u03b7\u03c4\u03b1 \u03ba\u03b1\u03bb\u03c9\u03b4\u03af\u03bf\u03c5 \u03b5\u03b9\u03c3\u03cc\u03b4\u03bf\u03c5<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b11%<\/td>\n<\/tr>\n<tr>\n<td>\u03a3\u03c4\u03b1\u03b8\u03b5\u03c1\u03cc\u03c4\u03b7\u03c4\u03b1 \u03c6\u03bf\u03c1\u03c4\u03af\u03bf\u03c5<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b14%<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b14%<\/td>\n<td>\u00b14%<\/td>\n<td>\u00b14%<\/td>\n<td>\u00b14%<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b14%<\/td>\n<td>\u00b11%<\/td>\n<\/tr>\n<tr>\n<td>Series summary power (not per rail)<\/td>\n<td colspan=\"3\">60W (series summary; group rating not separately stated)<\/td>\n<td colspan=\"3\">60W (series summary; group rating not separately stated)<\/td>\n<td colspan=\"3\">60W (series summary; group rating not separately stated)<\/td>\n<td colspan=\"3\">60W (series summary; group rating not separately stated)<\/td>\n<\/tr>\n<tr>\n<td>\u0391\u03c0\u03bf\u03b4\u03bf\u03c4\u03b9\u03ba\u03cc\u03c4\u03b7\u03c4\u03b1<\/td>\n<td colspan=\"3\">72%<\/td>\n<td colspan=\"3\">72%<\/td>\n<td colspan=\"3\">72%<\/td>\n<td colspan=\"3\">72%<\/td>\n<\/tr>\n<tr>\n<td>\u03a1\u03c5\u03b8\u03bc\u03b9\u03b6\u03cc\u03bc\u03b5\u03bd\u03bf \u03b5\u03cd\u03c1\u03bf\u03c2 \u03b3\u03b9\u03b1 \u03c4\u03ac\u03c3\u03b7 DC<\/td>\n<td colspan=\"3\">CH1: \u00b110%; CH2: \u00b15%; CH3: \u00b15% (independent controls not stated)<\/td>\n<td colspan=\"3\">CH1: \u00b110%; CH2: \u00b15%; CH3: \u00b15% (independent controls not stated)<\/td>\n<td colspan=\"3\">CH1: \u00b110%; CH2: \u00b15%; CH3: \u00b15% (independent controls not stated)<\/td>\n<td colspan=\"3\">CH1: \u00b110%; CH2: \u00b15%; CH3: \u00b15% (independent controls not stated)<\/td>\n<\/tr>\n<tr>\n<td>Input voltage \/ frequency<\/td>\n<td colspan=\"12\">85 ~ 264VAC; 120 ~ 370VDC; 47 ~ 63Hz<\/td>\n<\/tr>\n<tr>\n<td>\u03a1\u03b5\u03cd\u03bc\u03b1 \u03b5\u03b9\u03c3\u03cc\u03b4\u03bf\u03c5 AC<\/td>\n<td colspan=\"12\">Cold start current 30A\/115VAC; 60A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td>\u03a1\u03b5\u03cd\u03bc\u03b1 \u03b4\u03b9\u03b1\u03c1\u03c1\u03bf\u03ae\u03c2<\/td>\n<td colspan=\"12\">Not specified in the bound datasheet.<\/td>\n<\/tr>\n<tr>\n<td>\u03a0\u03c1\u03bf\u03c3\u03c4\u03b1\u03c3\u03af\u03b1 \u03c5\u03c0\u03b5\u03c1\u03c6\u03cc\u03c1\u03c4\u03c9\u03c3\u03b7\u03c2<\/td>\n<td colspan=\"12\">105% ~ 150% cut off the output, automatic recovery; reference base, channel coverage and waveform not stated.<\/td>\n<\/tr>\n<tr>\n<td>\u03a0\u03c1\u03bf\u03c3\u03c4\u03b1\u03c3\u03af\u03b1 \u03b1\u03c0\u03cc \u03c5\u03c0\u03ad\u03c1\u03c4\u03b1\u03c3\u03b7<\/td>\n<td colspan=\"12\">CH1: 115 ~ 135%; shut down O\/P voltage, re-power on to recover. CH2\/CH3 protection not specified.<\/td>\n<\/tr>\n<tr>\n<td>Temperature Coefficient<\/td>\n<td colspan=\"12\">Not specified in the bound datasheet.<\/td>\n<\/tr>\n<tr>\n<td>Setup, Rise, Hold Up Time<\/td>\n<td colspan=\"12\">300ms, 50ms, 80ms\/230VAC at full load<\/td>\n<\/tr>\n<tr>\n<td>\u0394\u03cc\u03bd\u03b7\u03c3\u03b7<\/td>\n<td colspan=\"12\">Not specified in the bound datasheet.<\/td>\n<\/tr>\n<tr>\n<td>\u0391\u03bd\u03c4\u03bf\u03c7\u03ae \u03c4\u03ac\u03c3\u03b7\u03c2<\/td>\n<td colspan=\"12\">I\/P-O\/P: 1.5kV; I\/P-FG: 1.5kV; O\/P-FG: 0.5kV; 1 minute. Test waveform not specified; no output-to-output rating stated.<\/td>\n<\/tr>\n<tr>\n<td>\u0391\u03bd\u03c4\u03af\u03c3\u03c4\u03b1\u03c3\u03b7 \u03b1\u03c0\u03bf\u03bc\u03cc\u03bd\u03c9\u03c3\u03b7\u03c2<\/td>\n<td colspan=\"12\">I\/P-O\/P, I\/P-FG, O\/P-FG: 500VDC\/100M\u03a9. Output-to-output isolation and commoning permissions not specified.<\/td>\n<\/tr>\n<tr>\n<td>Working temperature \/ humidity<\/td>\n<td colspan=\"12\">-10\u2103 ~ +50\u2103; humidity, derating curve and full-temperature full-load conditions not specified.<\/td>\n<\/tr>\n<tr>\n<td>\u03a3\u03c5\u03bd\u03bf\u03bb\u03b9\u03ba\u03ae \u03b4\u03b9\u03ac\u03c3\u03c4\u03b1\u03c3\u03b7<\/td>\n<td colspan=\"12\">159 \u00d7 98 \u00d7 38mm<\/td>\n<\/tr>\n<tr>\n<td>\u0392\u03ac\u03c1\u03bf\u03c2<\/td>\n<td colspan=\"12\">0.55kg<\/td>\n<\/tr>\n<tr>\n<td>\u03a0\u03c1\u03cc\u03c4\u03c5\u03c0\u03b1 \u0391\u03c3\u03c6\u03b1\u03bb\u03b5\u03af\u03b1\u03c2<\/td>\n<td colspan=\"12\">Certification not specified in the bound datasheet; verification required.<\/td>\n<\/tr>\n<tr>\n<td>EMC Standards<\/td>\n<td colspan=\"12\">Approval not specified in the bound datasheet; verification required.<\/td>\n<\/tr>\n<tr>\n<td>\u03a3\u03c5\u03c3\u03ba\u03b5\u03c5\u03b1\u03c3\u03af\u03b1<\/td>\n<td colspan=\"12\">34 \u00d7 32 \u00d7 24CM\/30PCS\/16.5kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"1636701110045-2231239d-d5c7\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1636701110045-2231239d-d5c7\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u03a3\u03c7\u03ad\u03b4\u03b9\u03bf<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left wpb_content_element\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/T-60-1024x343.png\" target=\"_self\" class=\"vc_single_image-wrapper   vc_box_border_grey\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1040\" height=\"348\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/T-60.png\" class=\"vc_single_image-img attachment-full\" alt=\"T 60\" title=\"T 60\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/T-60.png 1040w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/T-60-300x100.png 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/T-60-1024x343.png 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/T-60-768x257.png 768w\" sizes=\"(max-width: 1040px) 100vw, 1040px\" style=\"width:100%;height:33.46%;max-width:1040px;\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"1636701110038-e7dfe23b-653a\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1636701110038-e7dfe23b-653a\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u03a7\u03b1\u03c1\u03b1\u03ba\u03c4\u03b7\u03c1\u03b9\u03c3\u03c4\u03b9\u03ba\u03ac<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3>Why Choose T-60<\/h3>\n<h4>Choose a documented multi-voltage combination<\/h4>\n<p>Examples include T-60B 5V\/12V\/-12V; T-60C 5V\/15V\/-15V.<\/p>\n<p>The bipolar alternatives give a host designed for logic and signed analog inputs a clear channel map for its receiver and signal-conditioning boards; actual load and reference compatibility still need qualification.<\/p>\n<h4>Build the load review around printed current windows<\/h4>\n<p>T-60B lists CH1 0 ~ 5A, CH2 0 ~ 2.5A, CH3 0 ~ 0.5A.<\/p>\n<p>Use the printed windows to review a bridge amplifier or signal receiver as a complete host, with logic and both analog paths identified separately; validate idle and startup demand rather than selecting from the series power name alone.<\/p>\n<h4>Match the input specification to the host supply<\/h4>\n<p>The input row specifies 85 ~ 264VAC, 120 ~ 370VDC and 47 ~ 63Hz.<\/p>\n<p>Review the receiver host against this model&#x27;s broad AC row and separate DC row; a switch instruction from a different series is not evidence for this model.<\/p>\n<h4>Plan the physical electronics compartment early<\/h4>\n<p>The documented envelope is 159 \u00d7 98 \u00d7 38mm and weight is 0.55kg.<\/p>\n<p>Start the receiver or bridge-instrument compartment around this envelope, then qualify fixing points, service access and ventilation rather than treating outer dimensions as a complete installation drawing.<\/p>\n<h3>Features and Benefits<\/h3>\n<h4>Version-specific triple outputs<\/h4>\n<p>The four combinations are T-60A 5V\/12V\/-5V; T-60B 5V\/12V\/-12V; T-60C 5V\/15V\/-15V; T-60D 5V\/12V\/24. The final T-60D voltage unit is not printed and must be verified.<\/p>\n<p>The complete three-channel table is the selection basis; do not split a single combination into independent output SKUs.<\/p>\n<h4>Documented overload and channel-specific overvoltage response<\/h4>\n<p>Overload protection is listed as 105% ~ 150% output cut-off with automatic recovery.<\/p>\n<p>CH1 overvoltage protection is 115 ~ 135%, with output recovery after re-powering.<\/p>\n<p>The page does not establish an overload reference base, a hiccup waveform or matching overvoltage thresholds on the other channels.<\/p>\n<h4>Timing entries with an explicit test condition<\/h4>\n<p>The table lists 300ms setup, 50ms rise and 80ms hold-up at 230VAC and full load.<\/p>\n<p>These values support interruption planning, but do not guarantee host data retention or full-load operation across the complete working-temperature range.<\/p>\n<h4>Consistent group efficiency entries<\/h4>\n<p>Efficiencies are 72%, 72%, 72%, 72% for T-60A, T-60B, T-60C and T-60D respectively.<\/p>\n<p>The group entries are not per-rail efficiencies, and their load and temperature test conditions are not supplied on the page.<\/p>\n<h3>Typical Service Conditions<\/h3>\n<h4>Assess the complete analog and digital load set<\/h4>\n<p>For a host explicitly accepting the specified bipolar analog and logic voltages, assess idle demand and measurement-start transients together.<\/p>\n<p>T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V contact-meter processing-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive analog measurement-board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative analog measurement-board supply input.<\/p>\n<p>Qualify all three channel demands together through idle, startup and transients. Printed current-range lower bounds are not independent minimum-load rules; range endpoints and series-summary power do not establish simultaneous continuous loading.<\/p>\n<p>Variant-specific terminal polarity, return mapping, signal-reference compatibility and protective bonding require separate engineering evidence. Do not assume output commoning, inter-output isolation or permitted strapping; a concealed supply does not waive these prerequisites.<\/p>\n<h4>Plan interruption and restart behaviour<\/h4>\n<p>Check recovery of the compatible decoding electronics after an input interruption; process-loop excitation and isolation are separately supplied and assessed.<\/p>\n<p>T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V loop-decoder logic-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive analog receiver-board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative analog receiver-board supply input.<\/p>\n<p>Qualify all three channel demands together through idle, startup and transients. Printed current-range lower bounds are not independent minimum-load rules; range endpoints and series-summary power do not establish simultaneous continuous loading.<\/p>\n<p>Variant-specific terminal polarity, return mapping, signal-reference compatibility and protective bonding require separate engineering evidence. Do not assume output commoning, inter-output isolation or permitted strapping; a concealed supply does not waive these prerequisites.<\/p>\n<h4>Assess compartment temperature and access<\/h4>\n<p>Qualify the mounted receiver compartment with its real joint load, access, ventilation and measured temperature rather than inferring a cooling method from enclosure shape.<\/p>\n<p>T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V waveform-acquisition processing-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive analog receiver-board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative analog receiver-board supply input.<\/p>\n<p>Qualify all three channel demands together through idle, startup and transients. Printed current-range lower bounds are not independent minimum-load rules; range endpoints and series-summary power do not establish simultaneous continuous loading.<\/p>\n<p>Variant-specific terminal polarity, return mapping, signal-reference compatibility and protective bonding require separate engineering evidence. Do not assume output commoning, inter-output isolation or permitted strapping; a concealed supply does not waive these prerequisites.<\/p>\n<h4>Confirm returns and signal-reference compatibility<\/h4>\n<p>Obtain variant-specific terminal and signal-reference evidence before connecting a compatible bipolar multiplexer front end; source legend labels do not approve return strapping.<\/p>\n<p>T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V sensor-multiplexer controller DC input; CH2 12V (0 ~ 2.5A) for 12V positive analog switching-board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative analog switching-board supply input.<\/p>\n<p>Qualify all three channel demands together through idle, startup and transients. Printed current-range lower bounds are not independent minimum-load rules; range endpoints and series-summary power do not establish simultaneous continuous loading.<\/p>\n<p>Variant-specific terminal polarity, return mapping, signal-reference compatibility and protective bonding require separate engineering evidence. Do not assume output commoning, inter-output isolation or permitted strapping; a concealed supply does not waive these prerequisites.<\/p>\n<h3>Application Industries<\/h3>\n<h4>Weigh-hopper signal processing<\/h4>\n<p>Consider only a compatible local weighing-electronics assembly; hopper gates, vibrators, process drives and safety equipment have separate power and qualification.<\/p>\n<p>T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V hopper-weight processing-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive load-cell signal-conditioning board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative load-cell signal-conditioning board supply input.<\/p>\n<p>Jointly qualify controller and bridge-board demand through empty-hopper idle, sampling and restart; the printed ranges are not independent minimum-load or simultaneous continuous-load approval.<\/p>\n<p>Confirm bridge reference, signal returns, terminal mapping and protective bonding for the exact variant before connection; no permission to common outputs or assume inter-output isolation is inferred.<\/p>\n<h4>Melt-pressure signal acquisition<\/h4>\n<p>Consider compatible local pressure-acquisition electronics only; extrusion heaters, screw drives and machine protection remain separately supplied and qualified.<\/p>\n<p>T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V pressure-acquisition processing-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive pressure-amplifier board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative pressure-amplifier board supply input.<\/p>\n<p>Evaluate pressure-acquisition demand through sensor settling, sample capture and restart as a joint-load problem; endpoint currents are not a separately approved continuous power budget.<\/p>\n<p>Confirm the pressure-amplifier references, returns and variant terminal assignments separately. The generic legend does not approve shared returns or inter-output isolation.<\/p>\n<h4>Textile tension-signal conditioning<\/h4>\n<p>Consider compatible local tension-measurement electronics, not the web-drive or actuator power; qualify bridge excitation, returns and all channel demands separately.<\/p>\n<p>T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V tension-processing controller DC input; CH2 12V (0 ~ 2.5A) for 12V positive bridge-amplifier board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative bridge-amplifier board supply input.<\/p>\n<p>Assess the complete tension-electronics load during stationary-web idle and signal acquisition; neither range endpoints nor the series description establishes a continuous combined load rating.<\/p>\n<p>Qualify bridge excitation, signal-reference compatibility, return routing and exact terminal assignments for the host; do not infer output commoning or isolation from the signed voltage labels.<\/p>\n<h4>Process-analysis detector-signal integration<\/h4>\n<p>Consider compatible local detector-signal electronics only; detector bias, heaters, pumps and analytical or hazardous-area approvals are separate requirements.<\/p>\n<p>T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V detector-signal integration-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive detector-amplifier board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative detector-amplifier board supply input.<\/p>\n<p>Review detector-amplifier and processing demand as one host during baseline settling and data capture; the printed ranges are not a metrology-performance or simultaneous-loading approval.<\/p>\n<p>Verify detector-board references, returns, protective bonding and variant-specific wiring before connection. The source does not supply output commoning or inter-output isolation permission.<\/p>\n<h3>Technical FAQ<\/h3>\n<h4>Which voltage combinations belong to T-60?<\/h4>\n<p>T-60A 5V\/12V\/-5V; T-60B 5V\/12V\/-12V; T-60C 5V\/15V\/-15V; T-60D 5V\/12V\/24. The final T-60D voltage unit is not printed and must be verified.<\/p>\n<p>These are complete three-channel model combinations; variant-specific terminal mapping remains a separate engineering prerequisite.<\/p>\n<h4>Does the series power description establish an independent rating for every output?<\/h4>\n<p>The summary describes 60W for the series.<\/p>\n<p>It does not provide separate continuous per-rail power ratings or simultaneous endpoint-load approval. Voltage-current multiplication must not be used to create those missing ratings.<\/p>\n<h4>What current ranges are printed for the exact output combinations?<\/h4>\n<p>T-60A: CH1 0 ~ 5A; CH2 0 ~ 2.5A; CH3 0 ~ 0.5A.<\/p>\n<p>T-60B: CH1 0 ~ 5A; CH2 0 ~ 2.5A; CH3 0 ~ 0.5A.<\/p>\n<p>T-60C: CH1 0 ~ 5A; CH2 0 ~ 2A; CH3 0 ~ 0.5A.<\/p>\n<p>T-60D: CH1 0.5 ~ 5A; CH2 0.2 ~ 2.5A; CH3 0.2 ~ 0.5A.<\/p>\n<p>These are literal current ranges, not independent minimum-load or cross-regulation acceptance criteria; qualify all channel demands together.<\/p>\n<h4>What input range and selection method are documented?<\/h4>\n<p>The input row is 85 ~ 264VAC, 120 ~ 370VDC and 47 ~ 63Hz.<\/p>\n<p>The page does not state an input-selection switch; do not import a switched-band instruction from another model.<\/p>\n<h4>Which cold-start current belongs to each input voltage?<\/h4>\n<p>Cold-start current is 30A at 115VAC and 60A at 230VAC.<\/p>\n<p>These are voltage-specific inrush entries, not continuous input-current ratings; assess the host input path and protection separately.<\/p>\n<h4>How are overload and overvoltage recovery scoped?<\/h4>\n<p>Overload protection is 105% ~ 150% output cut-off with automatic recovery.<\/p>\n<p>CH1 overvoltage protection is 115 ~ 135%, with re-powering to recover.<\/p>\n<p>The page does not extend that overvoltage threshold to other channels or define the overload reference base and waveform.<\/p>\n<h4>What are the setup, rise and hold-up entries and their condition?<\/h4>\n<p>The source lists 300ms setup, 50ms rise and 80ms hold-up at 230VAC and full load.<\/p>\n<p>The explicit full-load timing condition does not establish full-load thermal operation, safe process restart or host data retention.<\/p>\n<h4>How do the wave\/noise entries vary by model and channel?<\/h4>\n<p>T-60A wave\/noise: CH1 50mVp-p; CH2 100mVp-p; CH3 100mVp-p.<\/p>\n<p>T-60B wave\/noise: CH1 100mVp-p; CH2 120mVp-p; CH3 120mVp-p.<\/p>\n<p>T-60C wave\/noise: CH1 100mVp-p; CH2 120mVp-p; CH3 120mVp-p.<\/p>\n<p>T-60D wave\/noise: CH1 80mVp-p; CH2 100mVp-p; CH3 100mVp-p.<\/p>\n<p>Probe bandwidth and the complete noise test method are not specified on this page.<\/p>\n<h4>Which efficiency, line and load stability entries apply to each version?<\/h4>\n<p>T-60A efficiency 72%; line stability \u00b10.5%\/\u00b11%\/\u00b10.5% and load stability \u00b11%\/\u00b14%\/\u00b11% in CH1\/CH2\/CH3 order.<\/p>\n<p>T-60B efficiency 72%; line stability \u00b10.5%\/\u00b11%\/\u00b10.5% and load stability \u00b11%\/\u00b14%\/\u00b14% in CH1\/CH2\/CH3 order.<\/p>\n<p>T-60C efficiency 72%; line stability \u00b10.5%\/\u00b11%\/\u00b10.5% and load stability \u00b14%\/\u00b14%\/\u00b11% in CH1\/CH2\/CH3 order.<\/p>\n<p>T-60D efficiency 72%; line stability \u00b10.5%\/\u00b11%\/\u00b11% and load stability \u00b11%\/\u00b14%\/\u00b11% in CH1\/CH2\/CH3 order.<\/p>\n<p>These are group\/channel entries, not independent rail efficiency or a complete cross-load regulation method.<\/p>\n<h4>How are the printed adjustment ranges and channel labels interpreted?<\/h4>\n<p>T-60A printed adjustment cells: CH1: \u00b110%; CH2: \u00b15%; CH3: \u00b15%.<\/p>\n<p>T-60B printed adjustment cells: CH1: \u00b110%; CH2: \u00b15%; CH3: \u00b15%.<\/p>\n<p>T-60C printed adjustment cells: CH1: \u00b110%; CH2: \u00b15%; CH3: \u00b15%.<\/p>\n<p>T-60D printed adjustment cells: CH1: \u00b110%; CH2: \u00b15%; CH3: \u00b15%.<\/p>\n<p>Printed channel adjustment ranges do not establish three independently adjustable controls or simultaneous adjustment behaviour.<\/p>\n<h4>What mechanical, thermal and dielectric boundaries are supplied?<\/h4>\n<p>Working temperature is -10\u2103 ~ +50\u2103; the envelope is 159 \u00d7 98 \u00d7 38mm and weight is 0.55kg.<\/p>\n<p>Withstand entries are I\/P-O\/P 1.5kV, I\/P-FG 1.5kV and O\/P-FG 0.5kV for 1 minute.<\/p>\n<p>The resistance entry names I\/P-O\/P, I\/P-FG and O\/P-FG at 500VDC\/100M\u03a9.<\/p>\n<p>Cooling, humidity, derating, full-temperature full-load operation and the withstand AC\/DC waveform are not stated. These interface tests do not establish output-to-output isolation or permission to common outputs.<\/p>\n<h4>Does the generic terminal legend approve variant-specific wiring?<\/h4>\n<p>Pin 5 is printed as DC OUTPUT+V2.<\/p>\n<p>The legend does not establish terminal-to-rail applicability for every signed-output combination, permitted return strapping or inter-output isolation. Obtain the exact variant wiring evidence before connection.<\/p>\n<h3>Product information<\/h3>\n<p>Our partners can cooperate with us in OEM or ODM.<\/p>\n<p>WeHo\u2019s T-60 Series is an AC\/DC multi-output Power supply that standard models offer the most cost-effective option when multiple voltages are required.<\/p>\n<p>T-60 is a reliable switching power supply with high-quality material, durable, and safe to use.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"Specifications&amp;Model Model T-60A T-60B T-60C T-60D CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC Output Voltage 5V 12V -5V 5V 12V -12V 5V 15V -15V 5V 12V 24 (unit not printed; verification required) Output voltage tolerance (not separately stated) Not specified Not specified Not specified Not specified Not specified Not&hellip; <a class=\"more-link\" href=\"https:\/\/www.wehopower.com\/el\/product\/original-weho-60w-triple-output-5v-12v-24v-switching-power-supply\/\">\u03a3\u03c5\u03bd\u03b5\u03c7\u03af\u03c3\u03c4\u03b5 \u03c4\u03b7\u03bd \u03b1\u03bd\u03ac\u03b3\u03bd\u03c9\u03c3\u03b7 <span class=\"screen-reader-text\">WEHO T-60W triple output power supply \u2014 T-60A \/ T-60B \/ T-60C \/ T-60D<\/span><\/a>","protected":false},"author":1,"featured_media":783,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[35,39],"product_categories_new":[127],"class_list":["post-782","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-enclosed-switching-power-supply","product_category-d-t-q-series-multiple-output-power-supply","product_categories_new-triple-output-t-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product\/782","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/comments?post=782"}],"version-history":[{"count":1,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product\/782\/revisions"}],"predecessor-version":[{"id":20881,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product\/782\/revisions\/20881"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/media\/783"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/media?parent=782"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product_category?post=782"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/www.wehopower.com\/el\/wp-json\/wp\/v2\/product_categories_new?post=782"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}