| Especificación | S-75-12 | S-75-15 | S-75-24 | S-75-48 |
| Tensión de salida CC, corriente | 12V 0~6A | 15V 0~5A | 24V 0~3.2A | 48V 0~1.5A |
| Ola y ruido | 100mVp-p | 100mVp-p | 120mVp-p | 150mVp-p |
| Estabilidad del cable de entrada | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Estabilidad de carga | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Eficiencia | 78% | 79% | 82% | 83% |
| Rango ajustable para voltaje CC | ±10% | ±10% | ±10% | ±10% |
| Rango de voltaje de entrada | 90 ~ 132VAC/180 ~ 264VAC por interruptor 254 ~ 370VDC 47 ~ 63Hz | |||
| Corriente de impacto | Corriente de arranque en frío 15A/115VAC 30A/230VAC | |||
| Protección contra sobrecarga | 105%~150%corta la salida, recuperación automática | |||
| Protección contra sobretensión | 115% ~ 135% shut down O/P voltage, re-power on to recover | |||
| Configurar, levantarse, mantener el tiempo de actividad | 200ms, 50ms, 20ms/230VAC a plena carga | |||
| Voltaje de soporte | I/P-O/P:1,5 kV I/P-FG:1,5 kV O/P-FG:0,5 kV 1 minuto | |||
| Resistencia de aislamiento | I/P-O/P I/P-FG O/P-FG: 500 VCC/100 MΩ | |||
| Temperatura de trabajo | -10℃~+50℃ | |||
| Dimensión | Tamaño 159 × 98 × 38mm | |||
| Peso | 0.55kg | |||
| Embalaje | 34×32×24CM/30PCS/16.5kg | |||
Serie S-75 fuente de alimentación de conmutación simple normal
WEHO S-75 offers separate 12V, 15V, 24V and 48V single-output versions in a 159×98×38mm enclosure. This 75W-designated family gives equipment builders a compact option to evaluate for compatible local interface and monitoring electronics. The AC input is 90~132VAC/180~264VAC by switch, with 254~370VDC also listed. Select the exact suffix using its printed current range, ripple and the actual electronic load profile; confirm continuous duty, cooling and connections for the finished assembly. Share the required voltage and startup demand for model selection.
Si tiene alguna pregunta, no dude en contactarnos en Correo electrónico: [email protected]
- Descripción
Why Choose the S-75?
Match the 12V or 15V board without changing families
S-75-12 lists 12V 0~6A and S-75-15 lists 15V 0~5A. These separate alternatives let an equipment builder compare a board’s required voltage with a specific output column. Check startup and continuous duty for the selected suffix; the 75W designation does not define every usable voltage-current operating point.
Compare higher-voltage noise before selecting an interface supply
S-75-24 lists 120mVp-p ripple and S-75-48 lists 150mVp-p, versus 100mVp-p for the 12V and 15V versions. This distinction matters when screening interface electronics with different noise tolerances. Confirm performance at the connected board and cable arrangement rather than extending the lowest ripple figure to every model.
Plan installation around the actual 159mm outline
The 159×98×38mm outline and 0.55kg mass provide a concrete starting point for a protected electronics compartment. Check the mechanical drawing, mounting support, terminal access and thermal conditions in the real assembly. A similar enclosure photograph does not establish replacement compatibility or a required ventilation clearance.
Include both input selection and interruption behavior
The AC ranges require a switch setting, and setup, rise and hold-up are 200ms, 50ms and 20ms at 230VAC and full load. Include these conditions in equipment startup and reset planning. Neither the switch entry nor the hold-up figure establishes universal automatic selection or uninterrupted operation.
S-75 Features
Four alternative single-output models
S-75-12 lists 12V 0~6A; S-75-15 lists 15V 0~5A; S-75-24 lists 24V 0~3.2A; S-75-48 lists 48V 0~1.5A. These are separately ordered models, not four simultaneous outputs. The printed zero lower bounds do not independently establish no-load regulation.
Consistent stability with output-specific efficiency
All four models list ±0.5% line stability, ±0.5% load stability and ±10% DC-voltage adjustment. Efficiencies are 78%, 79%, 82% and 83% in 12V, 15V, 24V and 48V order. Use the figures for the selected version when evaluating voltage tolerance and heat in the equipment.
Condition-qualified input startup
Cold-start current is 15A at 115VAC and 30A at 230VAC. Assess upstream switching at the applicable input voltage. These transient entries are not continuous input-current ratings and do not determine a circuit-breaker rating for the completed equipment.
Different responses for overload and overvoltage
Overload at 105%~150% cuts off output with automatic recovery. Overvoltage at 115%~135% shuts down output and requires re-powering to recover. This distinction supports reset planning, but does not replace downstream protection or establish sustained fault duty.
Typical Service Conditions
Keep a card-encoding kiosk’s electronics dry
A magnetic-stripe card-encoding kiosk may evaluate a selected S-75 for compatible local controller and user-interface boards. Protect the electrical compartment from cleaning fluid and debris, and confirm actual compartment temperature and load demand. Card-transport motors and write-head excitation require separately qualified power and controls.
Separate dryer monitoring from process heat
A desiccant-dryer monitoring tower needs its supply compartment separated from hot process surfaces, with a verified thermal environment. A suitable S-75 version would serve only compatible local monitoring and communication electronics. Regeneration heaters, blowers and pressure controls remain separate functions; -10°C~+50°C is not a full-load thermal guarantee.
Protect a parts-washer cycle indicator from spray
For a parts-washer cycle indicator, use a dry, separately engineered electrical area and verify cable entry, bonding and electronic-load compatibility. S-75 is only a candidate for local indication and interface boards. Pumps, heaters, fluid-contact equipment and any wet-area installation rating need independent qualification.
Control noise at a PCB depaneling console
A PCB depaneling operator console needs routing that separates mains and machine-drive conductors from its interface wiring. Evaluate the exact S-75 output’s ripple and board startup response in the actual enclosure. Spindles, cutting axes, extraction equipment and machine safety are outside this proposed electronic role.
Potential S-75 Applications
Fiber-optic patch test station
Evaluate a selected S-75 output for compatible status, display and communication boards in a fiber-optic patch test station. Verify voltage tolerance and reset behavior with the real electronics. Optical transmitters, receiver references and measurement accuracy require their own qualification; the supply choice does not establish an optical test specification.
Pallet stretch-wrapper operator pedestal
A pallet stretch-wrapper operator pedestal may assess an exact S-75 suffix for compatible interface and status electronics. Check continuous and startup demand and protected service access. Turntable drives, film-carriage motors, braking and emergency-stop functions require separately engineered power and safety systems.
Industrial sewing pattern terminal
Consider an S-75 version for compatible pattern-selection, display and communication electronics on an industrial sewing workstation. Verify the actual boards and restart sequence. Sewing motors, needle positioning, solenoids and operator protection remain independently qualified functions.
Air-compressor event recorder
An air-compressor event recorder may evaluate a qualified S-75 output for compatible local logging and communication electronics. Check vibration exposure, compartment temperature and voltage requirements. Compressor motors, unloading valves, pressure-sensor excitation and protective shutdown are not established by this electronic-supply concept.
S-75 Technical FAQs
Which exact output models and current ranges are listed?
S-75-12 lists 12V 0~6A; S-75-15 lists 15V 0~5A; S-75-24 lists 24V 0~3.2A; S-75-48 lists 48V 0~1.5A. These are separate single-output models, not simultaneous rails. Select one exact suffix for the connected board.
Does the 75W designation establish every continuous operating point?
The family designation and the printed current ranges are separate entries. Do not calculate a replacement continuous wattage from their endpoints or assume maximum output at every input and temperature. Confirm the ordered suffix’s continuous and startup duty. The printed zero lower bounds do not independently establish minimum-load or no-load acceptance.
Is the AC input automatically selected?
The input entry is 90~132VAC/180~264VAC by switch, with 254~370VDC and 47~63Hz also listed. This requires manual AC selection, not an automatic universal-input assumption. Confirm the actual switch setting and connection instructions before energizing, including any proposed DC-input use.
What does the DC-voltage adjustment range establish?
All listed versions have ±10% DC-voltage adjustment. Check the connected board’s voltage limits and the exact model’s accepted duty before adjusting. This entry does not establish regulated-current output, dimming, battery charging or arbitrary programmable operation.
What ripple and line/load stability apply to each suffix?
S-75-12: 100mVp-p, line stability ±0.5%, load stability ±0.5%; S-75-15: 100mVp-p, line stability ±0.5%, load stability ±0.5%; S-75-24: 120mVp-p, line stability ±0.5%, load stability ±0.5%; S-75-48: 150mVp-p, line stability ±0.5%, load stability ±0.5%. Keep the line and load entries distinct. These entries do not specify a ripple measurement bandwidth or cable method.
Which efficiency and cold-start entries apply to this family?
S-75-12: 78%; S-75-15: 79%; S-75-24: 82%; S-75-48: 83%. Cold-start current is 15A/115VAC and 30A/230VAC. Each transient applies to its stated input voltage and is not continuous input current. Efficiency measurement conditions beyond the printed entries need confirmation.
How does overload protection recover?
The overload entry is 105%~150%, cutting off output with automatic recovery. It is not a continuous overload allowance or a replacement for branch and cable protection. Evaluate the electronics’ restart behavior and repeated-fault response in the completed equipment.
Does overvoltage shutdown require re-powering?
The overvoltage entry is 115%~135%, shutting down output voltage and requiring re-powering to recover. Keep this separate from automatic overload recovery. Downstream protection and safe equipment restart require their own verification.
Which setup, rise and hold-up times and test conditions are stated?
Setup, rise and hold-up are 200ms, 50ms and 20ms at 230VAC and full load. The stated input and full-load conditions apply to this timing entry. Full-load timing does not establish full-temperature full-load operation, an uninterrupted supply or the same response at all input voltages and loads.
What working temperature, dimensions and mass are listed?
The entries are -10°C~+50°C, 159×98×38mm and 0.55kg. Check the actual compartment temperature, mounting, terminal access and cooling arrangement. These entries do not provide an ingress rating, humidity limit or complete full-load derating curve.
What withstand and isolation-resistance entries are printed?
Withstand entries are I/P-O/P 1.5kV, I/P-FG 1.5kV and O/P-FG 0.5kV for 1 minute, without a printed AC/DC qualifier. Isolation resistance is I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ. These component test entries do not establish certification scope or finished-equipment approval.
What terminal order does the drawing show?
The drawing labels pins 1 and 2: AC input; pin 3: GND; pin 4: DC output-V; pin 5: DC output+V. Confirm the delivered terminal markings, connection instructions, conductor ratings and protective bonding before wiring. The AC labels do not establish DC-input terminal assignments.