Fuente de alimentación conmutada única normal serie S-15W

WEHO S-15 is a 15W-designated single-output power-supply family for compatible local control, display and interface electronics. Separate 5V, 12V, 15V and 24V versions use a 98×97×35mm enclosure and have a listed mass of 0.3kg. AC input is 90~132VAC/180~264VAC by switch; 254~370VDC is also listed. Choose the exact output suffix and confirm load, startup, thermal and connection requirements for the equipment.

Si tiene alguna pregunta, no dude en contactarnos en Correo electrónico: [email protected]

Especificación S-15-5 S-15-12 S-15-15 S-15-24
Tensión de salida CC, corriente 5V 0~3A 12V 0~1.3A 15V0~1A 24V 0~0.7A
Ola y ruido 50mVp-p 50mVp-p 75 mVp-P 100mVp-p
Estabilidad del cable de entrada ±0,5% ±0,5% ±0,5% ±0,5%
Estabilidad de carga ±1% ±0,5% ±0,5% ±0,5%
Eficiencia 65% 68% 70% 72%
Rango ajustable para voltaje CC ±10% ±10% ±10% ±10%
Rango de voltaje de entrada 90 ~ 132VAC/180 ~ 264VAC por interruptor 254 ~ 370VDC 47 ~ 63Hz
Corriente de impacto Corriente de arranque en frío 15A/115VAC 30A/230VAC
Protección contra sobrecarga 105%~150%corta la salida, recuperación automática
Protección contra sobretensión 115% ~ 135% shut down O/P voltage, re-power on to recover
Configurar, levantarse, mantener el tiempo de actividad 200ms,100ms,30ms/230VAC at full load
Voltaje de soporte I/P-O/P:1,5 kV I/P-FG:1,5 kV O/P-FG:0,5 kV 1 minuto
Resistencia de aislamiento I/P-O/P I/P-FG O/P-FG: 500 VCC/100 MΩ
Temperatura de trabajo -10℃~+50℃
Dimensión 98×97×35mm
Peso 0.3kg
Embalaje 43×32.5×24CM/60PCS/18kg

Why Choose the S-15?

Make the input setting part of the equipment build

The AC range is 90~132VAC/180~264VAC by switch. Equipment supplied to different line-voltage systems needs the correct selector setting, labeling and connection checks. Manual selection is required; the stated bands do not describe automatic universal-input operation.

Choose by the exact output and load tolerance

S-15-5, S-15-12, S-15-15 and S-15-24 are separate alternatives. The 5V model has ±1% load stability, while the others list ±0.5%. Use the ordered model’s current, ripple and regulation entries when checking its connected electronics.

Plan installation around the S-15 outline

The listed outline is 98×97×35mm. The S-15 legend places DC output+V at pin 1, DC output-V at pin 2, GND at pin 3 and AC input at pins 4 and 5. Check the actual drawing and delivered markings, with separate allowance for mounting, mains segregation and service access.

Use conditioned timing for startup coordination

The row lists 200ms setup, 100ms rise and 30ms hold-up at 230VAC and full load. These are useful inputs to a controller reset assessment, not a promise for every load and interruption. Include the real board demand and required restart behavior in system tests.

S-15 Features

Four single-output voltage choices

The table lists 5V 0~3A, 12V 0~1.3A, 15V 0~1A and 24V 0~0.7A as separate output models. Choose the exact suffix for the electronic load. The 15W designation and printed range endpoints do not define usable continuous duty for every input and temperature.

Output-dependent ripple and stability

Ripple and noise are 50mVp-p, 50mVp-p, 75mVp-p and 100mVp-p in output-voltage order. Line stability is ±0.5% for all versions; load stability is ±1% at 5V and ±0.5% for the other outputs. No one best figure applies to every model.

Cold-start values at two input conditions

The table states 15A at 115VAC and 30A at 230VAC. Keep these values with their actual conditions for upstream switching assessment. They are transient inrush entries, not continuous input-current ratings or proof of identical behavior at all line voltages.

Adjustment and separate fault recovery

Each model lists ±10% DC-voltage adjustment. Overload cutoff at 105%~150% has automatic recovery, while overvoltage shutdown at 115%~135% requires re-powering. Adjustment is not constant-current control, and protective responses are not finished-equipment certification.

Typical Service Conditions

Keep a tank-level alarm panel dry

A tank-level alarm panel may evaluate the S-15 for compatible display and interface electronics in a protected enclosure. Manage condensation and separate the supply from process moisture. Sensor isolation, hazardous-area requirements and the alarm’s safety role need independent design evidence.

Confirm input selection in a hatch-position monitor

A hatch-position monitor needs the correct AC switch setting before the equipment is energized. Check the delivered terminal markings, connection instructions and board voltage. Actuator power, position safety and emergency operation remain separate functions.

Segregate a pump-room status annunciator

A status annunciator may assess a selected output for compatible indication and communication electronics. Keep mains and signal routing controlled, and assess local heat and humidity separately. Pump-motor power and building-wide distribution require separate system design.

Check thermal exposure around a chamber display bay

A thermal-chamber display bay must keep the supply within its accepted local thermal conditions, not the chamber process temperature. The -10°C~+50°C entry does not approve full load at every temperature. Heaters, compressors, fans and chamber safety require separate power and system design.

Potential S-15 Applications

Differential-pressure display panel

Evaluate an exact S-15 output for compatible local display and interface electronics in a dry pressure-monitoring panel. Confirm voltage tolerance and noise at the board. Pressure measurement accuracy, sensor isolation and any protective trip function are independent requirements.

Loom yarn-break monitor

A yarn-break monitor may assess a qualified S-15 variant for compatible logic and indication electronics inside a protected electrical section. Validate the real sensor-interface demand. Loom drives, stop-motion actuation and machine safety are not qualified by the power-supply choice.

Access-lane status indicator

Consider a selected output for compatible status-indication and interface electronics in an industrial access-lane cabinet. Verify voltage, startup and environmental conditions. Gate motors, locks, emergency egress and safety interlocks require separately qualified systems.

Optical micrometer controller

An optical micrometer controller may evaluate an S-15 variant for accepted local electronics after checking noise and thermal conditions. Optical emitter power, signal isolation and dimensional accuracy need independent validation. The supply is not a calibrated measurement reference or an approved laser driver.

S-15 Technical FAQs

Which output models and current ranges are listed?

S-15-5 lists 5V 0~3A; S-15-12 lists 12V 0~1.3A; S-15-15 lists 15V 0~1A; S-15-24 lists 24V 0~0.7A. They are alternative single-output variants, not four simultaneous outputs.

Does the 15W designation prove continuous operation at every endpoint?

The 15W family designation and the printed current ranges do not define a complete continuous operating envelope. Confirm the exact suffix’s continuous duty, startup demand, input conditions and local temperature. The printed zero lower bounds do not independently establish no-load regulation or minimum-load requirements.

Is the S-15 input automatically selected?

AC input is 90~132VAC/180~264VAC by switch. The input row also lists 254~370VDC and 47~63Hz. Select the correct AC band before energizing; this is not automatic range selection. Confirm the delivered unit’s separate DC-input connection requirements before DC use.

Does the ±10% adjustment provide constant-current output?

No constant-current function is established by the ±10% DC-voltage adjustment entry. Check the load’s allowed voltage and the model’s permitted duty before adjustment. Dimming, programmable output and battery charging require their own documented functions.

How do ripple and stability differ by output?

Ripple is 50mVp-p for S-15-5 and S-15-12, 75mVp-p for S-15-15 and 100mVp-p for S-15-24. All versions list ±0.5% line stability. Load stability is ±1% for the 5V version and ±0.5% for the other three; no ripple bandwidth is supplied in this row.

What efficiencies and cold-start values are printed?

Efficiencies are 65%, 68%, 70% and 72% for S-15-5, S-15-12, S-15-15 and S-15-24 respectively. Cold-start current is 15A/115VAC and 30A/230VAC. Keep both input conditions intact; neither inrush value is a continuous input-current rating.

How does overload protection recover?

The overload row states 105%~150%, cutting off the output with automatic recovery. It does not approve sustained overload or replace cable and branch protection. Check the connected electronics’ behavior during a fault and automatic restart.

What restart is required after overvoltage shutdown?

The entry states 115%~135%, shutdown of the output voltage and re-powering to recover. Keep this separate from the overload row’s automatic recovery. The equipment’s restart policy and downstream protection must be evaluated independently.

Which three timing figures and condition belong to S-15?

Setup, rise and hold-up are 200ms, 100ms and 30ms at 230VAC and full load. The stated input and full-load conditions apply to this timing entry; they do not establish full-load operation across the entire temperature range. Check the connected electronics’ reset and interruption requirements in the actual equipment.

What working temperature, dimensions and mass are listed?

The values are -10°C~+50°C, 98×97×35mm and 0.3kg. Confirm the actual mounting drawing, terminal access and thermal instructions. No ingress rating, humidity specification or complete full-load derating curve is provided by those entries.

What dielectric and resistance entries are given?

The withstand row lists I/P-O/P 1.5kV, I/P-FG 1.5kV and O/P-FG 0.5kV for 1 minute, without an AC/DC qualifier. Isolation resistance is listed as 500VDC/100MΩ for the named pairs. These tests do not establish an undocumented certification or a complete equipment approval.

What terminal assignment is shown for S-15?

The S-15 legend labels pin 1 as DC output+V, pin 2 as DC output-V, pin 3 as GND and pins 4 and 5 as AC input. Confirm the exact delivered markings and connection instructions before wiring. The AC-input legend does not specify the connection requirements for a separate DC-input application.