{"id":20730,"date":"2026-11-03T10:08:38","date_gmt":"2026-11-03T02:08:38","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/tx4m-power-interruption-retained-settings-restart\/"},"modified":"2026-11-03T10:08:38","modified_gmt":"2026-11-03T02:08:38","slug":"tx4m-power-interruption-retained-settings-restart","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/es\/news\/tx4m-power-interruption-retained-settings-restart\/","title":{"rendered":"TX4-M After a Power Interruption: Separate Retained Settings from Restart Permission"},"content":{"rendered":"<figure class=\"hero\"><a href=\"https:\/\/www.wehopower.com\/es\/product\/tx4-series-tx4-m-economic-dual-display-pid-temperature-controller\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/hero-5.webp\" alt=\"TX4-M beside an external restart-review screen and thermal chamber, with the machine start button unlit.\" fetchpriority=\"high\" title=\"\"><\/a><figcaption>Retained settings and machine restart permission are separate checks. The external screen illustrates a machine-level review sequence, not a documented TX4 automatic restart feature. AI-assisted illustration.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-2.png\">View original product image<\/a><\/figure>\n<p><strong>Retained temperature-controller settings do not by themselves authorize a hot process to restart.<\/strong> A TX4-M can be part of a local temperature loop, but the machine must still determine the actual thermal state, sensor validity and permitted output state after power returns.<\/p>\n<p>This guide is for an OEM controls engineer writing a restart acceptance test. The central distinction is between information stored in a controller and the present condition of the equipment. It does not assert a verified TX4-M output state for every power-loss sequence.<\/p>\n<nav class=\"toc\" aria-label=\"On this page\">\n<ol>\n<li><a href=\"#what-is-retained\">List settings separately from physical process state<\/a><\/li>\n<li><a href=\"#outage-states\">Define several restart cases instead of one power cycle<\/a><\/li>\n<li><a href=\"#worked-temperature\">Show why the same retained setpoint is insufficient<\/a><\/li>\n<li><a href=\"#output-permission\">Make the restart permission explicit in the machine design<\/a><\/li>\n<li><a href=\"#acceptance\">Observe the complete return-to-service sequence<\/a><\/li>\n<li><a href=\"#configuration-control\">Keep the complete M code with the restart test<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"what-is-retained\">\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Tabla de contenido<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Alternar tabla de contenidos\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Palanca<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/es\/news\/tx4m-power-interruption-retained-settings-restart\/#List_settings_separately_from_physical_process_state\" >List settings separately from physical process state<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/es\/news\/tx4m-power-interruption-retained-settings-restart\/#Define_several_restart_cases_instead_of_one_power_cycle\" >Define several restart cases instead of one power cycle<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/es\/news\/tx4m-power-interruption-retained-settings-restart\/#Show_why_the_same_retained_setpoint_is_insufficient\" >Show why the same retained setpoint is insufficient<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/es\/news\/tx4m-power-interruption-retained-settings-restart\/#Make_the_restart_permission_explicit_in_the_machine_design\" >Make the restart permission explicit in the machine design<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/es\/news\/tx4m-power-interruption-retained-settings-restart\/#Observe_the_complete_return-to-service_sequence\" >Observe the complete return-to-service sequence<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/es\/news\/tx4m-power-interruption-retained-settings-restart\/#Keep_the_complete_M_code_with_the_restart_test\" >Keep the complete M code with the restart test<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/es\/news\/tx4m-power-interruption-retained-settings-restart\/#Power-interruption_restart_record\" >Power-interruption restart record<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/es\/news\/tx4m-power-interruption-retained-settings-restart\/#Sources_and_further_reading\" >Sources and further reading<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"List_settings_separately_from_physical_process_state\"><\/span>List settings separately from physical process state<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>El <a href=\"https:\/\/www.wehopower.com\/es\/product\/tx4-series-tx4-m-economic-dual-display-pid-temperature-controller\/\">WEHO TX4-M product table<\/a> describes nonvolatile memory retention for the family. The <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/11\/TX4.pdf\">TX4 230808EN manual<\/a> identifies startup display behavior and configuration items. These are useful starting documents, but a retention-duration statement does not demonstrate the complete output sequence of a specific installed unit after a voltage dip or outage.<\/p>\n<p>Set value, sensor type, units and control-output selection are configuration. Actual tool temperature, product condition, coolant flow and actuator position are physical states. A restored set value cannot tell the machine whether all of those states are ready for the next production cycle.<\/p>\n<\/section>\n<section id=\"outage-states\">\n<h2><span class=\"ez-toc-section\" id=\"Define_several_restart_cases_instead_of_one_power_cycle\"><\/span>Define several restart cases instead of one power cycle<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"fig-diagram\" class=\"diagram\"><img decoding=\"async\" class=\"technical-desktop\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-5.svg\" alt=\"Retained settings, actual process condition andoutput permission combine in a restart decision\" loading=\"lazy\" title=\"\"><img decoding=\"async\" class=\"technical-mobile\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-mobile-5.svg\" alt=\"Retained settings, actual process condition andoutput permission combine in a restart decision\" loading=\"lazy\" title=\"\"><figcaption>Restart review method;no specific TX4-M output sequence is claimed.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-5.svg\">Open full-size technical illustration<\/a><\/figure>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Case<\/th>\n<th scope=\"col\">What can differ after return<\/th>\n<th scope=\"col\">Evidence to record<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cold start<\/td>\n<td>Equipment and product begin near ambient<\/td>\n<td>Configuration, sensor reading, output permission<\/td>\n<\/tr>\n<tr>\n<td>Short interruption<\/td>\n<td>Tool may remain hot while controls reboot<\/td>\n<td>Interruption duration, PV, command state<\/td>\n<\/tr>\n<tr>\n<td>Long interruption<\/td>\n<td>Temperature and product condition may change substantially<\/td>\n<td>Actual condition and restart disposition<\/td>\n<\/tr>\n<tr>\n<td>Interrupted motion\/process step<\/td>\n<td>Sequence may no longer match physical position<\/td>\n<td>Machine-state recovery and operator action<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>These cases are not a universal timer specification. Choose durations and conditions from the actual process requirements. A dip that does not fully reboot one device may still reset another device in the chain, so the complete system response matters.<\/p>\n<\/section>\n<section id=\"worked-temperature\">\n<h2><span class=\"ez-toc-section\" id=\"Show_why_the_same_retained_setpoint_is_insufficient\"><\/span>Show why the same retained setpoint is insufficient<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Consider a hypothetical process whose retained set value is 160 \u00b0C. After one interruption the measured process temperature is 154 \u00b0C; after another it is 82 \u00b0C. The differences from the set value are 6 \u00b0C and 78 \u00b0C. Both cases can show the same 160 \u00b0C set value while requiring different warm-up, product disposition and readiness decisions.<\/p>\n<p>These are illustrative numbers, not measured TX4 temperatures or approved process tolerances. Neither a 6 \u00b0C difference nor a 78 \u00b0C difference alone determines restart permission. The process owner must define the acceptable thermal history and any other required conditions. Do not infer a soak-complete or product-quality result from a display returning to its set value.<\/p>\n<\/section>\n<section id=\"output-permission\">\n<h2><span class=\"ez-toc-section\" id=\"Make_the_restart_permission_explicit_in_the_machine_design\"><\/span>Make the restart permission explicit in the machine design<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Identify which device holds the power-switching command inactive until the machine is ready, how readiness is established and what happens if the controller reboots before the rest of the system. Use the documented complete output option and external switching interface. Avoid assuming that a relay or SSR-drive output automatically restarts safely, remains OFF or resumes its previous duty without an actual applicable source and verification.<\/p>\n<p>Separate controller operation from the independent protections required by the machine design. A local process controller, retained recipe and ordinary alarm should not be described as an independently qualified protective system. Any required manual acknowledgement must be a defined machine function, not merely an instruction hidden in the blog.<\/p>\n<\/section>\n<section id=\"acceptance\">\n<h2><span class=\"ez-toc-section\" id=\"Observe_the_complete_return-to-service_sequence\"><\/span>Observe the complete return-to-service sequence<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use an approved commissioning procedure to record source interruption, controller startup indications, actual measured temperature, selected output mode, external-switch command and the machine&#8217;s restart-permission state. Check that configuration read-back matches the controlled record. Include a case where the controller and another relevant subsystem return at different times if that can occur in the equipment.<\/p>\n<p>After restoration, verify the sensor and actual process state before admitting production. Record whether the process is resumed, rewarmed, inspected or rejected according to the process specification. Do not use a successful laboratory reboot as evidence for every voltage dip, firmware revision or installed power-switching arrangement.<\/p>\n<\/section>\n<section id=\"configuration-control\">\n<h2><span class=\"ez-toc-section\" id=\"Keep_the_complete_M_code_with_the_restart_test\"><\/span>Keep the complete M code with the restart test<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"fig-original\" class=\"product-original\"><a href=\"https:\/\/www.wehopower.com\/es\/product\/tx4-series-tx4-m-economic-dual-display-pid-temperature-controller\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-2.png\" alt=\"WEHO TX4-M front form with dual display and base model marking\" loading=\"lazy\" title=\"\"><\/a><figcaption>Official TX4-M front-form illustration. The complete order code and rear connection option must be confirmed separately.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-2.png\">View original image<\/a><\/figure>\n<p>The official TX4-M image identifies a 72 \u00d772 mm front form, not the full supply\/output\/alarm option or the exact restart behavior. Retain the device marking, manual revision, parameter record and tested machine logic together. A replacement controller or a restored recipe should trigger the relevant read-back and restart checks rather than inheriting the previous unit&#8217;s result automatically.<\/p>\n<\/section>\n<section class=\"cta\">\n<p>Send <a href=\"https:\/\/www.wehopower.com\/es\/contact\/\">WEHO<\/a> the complete TX4-M code, manual revision, outage cases, external output interface and restart observations. Ask for clarification of documented controller behavior while keeping machine restart acceptance with the responsible controls and process teams.<\/p>\n<\/section>\n<section id=\"worksheet\" class=\"sheet\">\n<h2><span class=\"ez-toc-section\" id=\"Power-interruption_restart_record\"><\/span>Power-interruption restart record<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"sheet-row\"><label>Full model<input aria-label=\"Full model\"><\/label><label>Parameter record\/revision<input aria-label=\"Parameter record\/revision\"><\/label><label>External switch<input aria-label=\"External switch\"><\/label><label>Process restart requirement<input aria-label=\"Process restart requirement\"><\/label><\/div>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Case<\/th>\n<th scope=\"col\">Interruption\/return sequence<\/th>\n<th scope=\"col\">Measured temperature<\/th>\n<th scope=\"col\">Actual process condition<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Read-back<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Sensor\/unit\/output selection<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Set value<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Diferencia<\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Output permission<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Before\/after return<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Machine interlocks<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Observed behavior<\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Disposition<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Resume\/warm\/inspect\/reject<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Evidence<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Responsible signoff<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Blank project worksheet. Enter verified project data; example calculations above are not measurements.<\/p>\n<\/section>\n<section class=\"source-list\">\n<h2><span class=\"ez-toc-section\" id=\"Sources_and_further_reading\"><\/span>Sources and further reading<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><a href=\"https:\/\/www.wehopower.com\/es\/product\/tx4-series-tx4-m-economic-dual-display-pid-temperature-controller\/\">WEHO TX4-M product information<\/a><\/li>\n<li><a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/11\/TX4.pdf\">TX4 230808EN startup\/configuration manual<\/a><\/li>\n<\/ol>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Review the TX4-M after a power interruption with a restart-state record. Stored temperature settings alone do not establish permission to resume heating.<\/p>","protected":false},"author":2,"featured_media":20705,"parent":0,"menu_order":177,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-20730","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/news\/20730","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/comments?post=20730"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/news\/20730\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/media\/20705"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/media?parent=20730"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/news_category?post=20730"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}