{"id":1146,"date":"2021-11-02T03:36:52","date_gmt":"2021-11-02T03:36:52","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=product&#038;p=1146"},"modified":"2026-11-12T17:04:34","modified_gmt":"2026-11-12T09:04:34","slug":"s-3000w-series-normal-single-switching-power-supply","status":"publish","type":"product","link":"https:\/\/www.wehopower.com\/es\/product\/s-3000w-series-normal-single-switching-power-supply\/","title":{"rendered":"Serie S-3000W fuente de alimentaci\u00f3n de conmutaci\u00f3n simple normal"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_tta-container\" data-vc-action=\"collapse\"><div class=\"vc_general vc_tta vc_tta-accordion vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-o-shape-group vc_tta-controls-align-default\"><div class=\"vc_tta-panels-container\"><div class=\"vc_tta-panels\"><div class=\"vc_tta-panel vc_active\" id=\"1636701172155-32719f5d-02c1\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1636701172155-32719f5d-02c1\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Especificaciones y modelo<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<table style=\"width: 100%;\" width=\"100%\">\n<tbody>\n<tr>\n<td width=\"210\">Especificaci\u00f3n<\/td>\n<td width=\"86\">S-3000-24<\/td>\n<td width=\"82\">S-3000-27<\/td>\n<td width=\"82\">S-3000-36<\/td>\n<td width=\"88\">S-3000-48<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Tensi\u00f3n de salida CC, corriente<\/td>\n<td width=\"86\">24V 0 ~ 125A<\/td>\n<td width=\"82\">27V 0 ~ 111A<\/td>\n<td width=\"82\">36V 0 ~ 83A<\/td>\n<td width=\"88\">48V 0 ~ 62.5A<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Ola y ruido<\/td>\n<td width=\"86\">240mVp-p<\/td>\n<td width=\"82\">240mVp-p<\/td>\n<td width=\"82\">300mVp-p<\/td>\n<td width=\"88\">300mVp-p<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Estabilidad del cable de entrada<\/td>\n<td width=\"86\">\u00b10,5%<\/td>\n<td width=\"82\">\u00b10,5%<\/td>\n<td width=\"82\">\u00b10,5%<\/td>\n<td width=\"88\">\u00b10,5%<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Estabilidad de carga<\/td>\n<td width=\"86\">\u00b10,5%<\/td>\n<td width=\"82\">\u00b10,5%<\/td>\n<td width=\"82\">\u00b10,5%<\/td>\n<td width=\"88\">\u00b10,5%<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Eficiencia<\/td>\n<td width=\"86\">80%<\/td>\n<td width=\"82\">82%<\/td>\n<td width=\"82\">85%<\/td>\n<td width=\"88\">87%<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Rango ajustable para voltaje CC<\/td>\n<td width=\"86\">\u00b110%<\/td>\n<td width=\"82\">\u00b110%<\/td>\n<td width=\"82\">\u00b110%<\/td>\n<td width=\"88\">\u00b110%<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Rango de voltaje de entrada<\/td>\n<td colspan=\"4\" width=\"338\">200 ~ 264VAC<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Corriente de impacto<\/td>\n<td colspan=\"4\" width=\"338\">Cold start current 70A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Protecci\u00f3n contra sobrecarga<\/td>\n<td colspan=\"4\" width=\"338\">105% ~ 135% cut off the output, automatic recovery<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Protecci\u00f3n contra sobretensi\u00f3n<\/td>\n<td colspan=\"4\" width=\"338\">Not specified in this datasheet (overvoltage threshold and short-circuit recovery mode are not stated).<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Configurar, levantarse, mantener el tiempo de actividad<\/td>\n<td colspan=\"4\" width=\"338\">2000ms, 50ms, 20ms\/230VAC at full load<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Voltaje de soporte<\/td>\n<td colspan=\"4\" width=\"338\">I\/P-O\/P: 1.5kV; I\/P-FG: 1.5kV; O\/P-FG: 0.5kV; 1 minute<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Resistencia de aislamiento<\/td>\n<td colspan=\"4\" width=\"338\">I\/P-O\/P, I\/P-FG, O\/P-FG: 500 VCC\/100 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Temperatura de trabajo<\/td>\n<td colspan=\"4\" width=\"338\">-10\u00b0C ~ +50\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Dimensi\u00f3n<\/td>\n<td colspan=\"4\" width=\"338\">291 \u00d7 132 \u00d7 136mm<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Peso<\/td>\n<td colspan=\"4\" width=\"338\">5.3kg<\/td>\n<\/tr>\n<tr>\n<td width=\"210\">Embalaje<\/td>\n<td colspan=\"4\" width=\"338\">38 \u00d7 37.5 \u00d7 21CM\/2PCS\/11kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"1636701110045-2231239d-d5c7\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1636701110045-2231239d-d5c7\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Dise\u00f1o<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left wpb_content_element\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimension-s-3000-1024x273.jpg\" target=\"_self\" class=\"vc_single_image-wrapper   vc_box_border_grey\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1223\" height=\"326\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimension-s-3000.jpg\" class=\"vc_single_image-img attachment-full\" alt=\"Overall dimension s 3000\" title=\"Overall dimension s 3000\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimension-s-3000.jpg 1223w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimension-s-3000-300x80.jpg 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimension-s-3000-1024x273.jpg 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/Overall-dimension-s-3000-768x205.jpg 768w\" sizes=\"(max-width: 1223px) 100vw, 1223px\" style=\"width:100%;height:26.66%;max-width:1223px;\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"1636701110038-e7dfe23b-653a\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1636701110038-e7dfe23b-653a\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Caracter\u00edsticas<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Why choose S-3000<\/h2>\n<h3>A clear high-current selection set<\/h3>\n<p>S-3000-24, S-3000-27, S-3000-36 and S-3000-48 address different fixed-voltage loads. The 48V model lists a 62.5A upper endpoint; the choice is not four outputs from one unit or an interchangeable set of ratings.<\/p>\n<h3>A defined high-line input boundary<\/h3>\n<p>The input is listed as 200~264VAC. Confirm the actual frequency, input pin functions and branch protection; this sheet does not state a low-line selector, DC-input range or three-phase connection.<\/p>\n<h3>Mechanical planning before cabinet commitment<\/h3>\n<p>The table gives 291\u00d7132\u00d7136mm and 5.3kg. Verify the third-dimension reference, projecting output contacts and ventilation\/service clearances against the actual unit before approving an enclosure drawing.<\/p>\n<h3>Substantial DC loading with a documented purpose<\/h3>\n<p>A high-current product-validation rig can warrant this power class where its DC demand is proven. A small status-board-only installation needs a separate sizing reason. The higher listed current makes conductor losses, joint heating and the continuous-duty assessment central to selection.<\/p>\n<h2>S-3000 features<\/h2>\n<h3>Ripple\/noise differs by voltage<\/h3>\n<p>The 24V and 27V columns list 240mVp-p; the 36V and 48V columns list 300mVp-p. Check the actual load\u2019s tolerance and the measurement method instead of applying a lower family member\u2019s noise figure.<\/p>\n<h3>Model-specific efficiency and stability<\/h3>\n<p>Line and load stability are each printed as \u00b10.5%. Efficiency entries are 80%, 82%, 85% and 87% in 24V, 27V, 36V and 48V order. The sheet does not provide the input, load and ambient conditions behind those efficiency figures.<\/p>\n<h3>Adjustment within an exact model<\/h3>\n<p>The adjustment entry is \u00b110% for each output. Validate device voltage tolerance, allowable current and heating at the intended setting; trim capability does not make the unit a programmable source or establish constant-power operation.<\/p>\n<h3>Automatic recovery after overload cut-off<\/h3>\n<p>The stated overload threshold is 105%~135%, with output cut-off and automatic recovery. Coordinate external protection and restart behaviour; do not infer additional protection functions or a permitted fault-duration rating.<\/p>\n<h2>S-3000 service conditions<\/h2>\n<h3>Display-module upstream-circuit planning<\/h3>\n<p>A rugged display-module aging gantry must operate within 200~264VAC. Its listed cold-start current is 70A at 230VAC; do not replace it with the 45A value of another model or treat it as the running current. The proposed DC duty is compatible DC electronic inputs of a measured display-module batch, not the gantry handling drives. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.<\/p>\n<h3>Telecom distribution-unit fixture service<\/h3>\n<p>A telecommunications DC distribution-unit acceptance rig needs the exact output, cable routes, contact temperature limits and load sequence established first. The 0~125A, 0~111A, 0~83A and 0~62.5A ranges do not establish continuous fixture capability or a minimum-load requirement. The proposed DC duty is compatible fixed-voltage DC inputs of distribution units under test, with branch loading and bonding individually designed. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.<\/p>\n<h3>Camera-module test-compartment ventilation<\/h3>\n<p>An industrial camera-module soak-test carousel must allow fan access, terminations and service space around the complete unit. Working temperature is listed as \u221210\u00b0C~+50\u00b0C; there is no airflow specification or derating curve proving full load at the endpoints. The proposed DC duty is compatible DC inputs of camera modules in an aggregate batch; optical targets and measurement supplies are separately specified. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.<\/p>\n<h3>Signalling-module sequenced testing<\/h3>\n<p>A DC signalling-module production tower should accommodate setup 2000ms, rise 50ms and hold-up 20ms at 230VAC and full load. Verify behaviour with the intended loads and assess overload recovery separately from normal startup timing. The proposed DC duty is compatible signalling-module DC input branches; not signalling logic or a protective function. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.<\/p>\n<h2>S-3000 application considerations<\/h2>\n<h3>Controller-assembly batch acceptance<\/h3>\n<p>A palletized controller-board acceptance machine may assess S-3000-24 for products specified to accept 24V DC. Confirm aggregate demand, startup current, switching noise and the continuous thermal allowance. Product motion outputs, regenerative loads, test instrumentation and the carrier drive remain separately engineered; the supply is not a precision programmable source. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.<\/p>\n<h3>Industrial DC blower-module qualification<\/h3>\n<p>An industrial DC blower-module qualification tunnel may evaluate a matching 24V or 48V S-3000 variant for documented product-side load demand. Verify start and stall current, switching transients, external protection and allowed duty before connection. The tunnel drive, facility ventilation and measurement equipment are separate; no airflow, efficiency or motor-control performance is claimed. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.<\/p>\n<h3>Machine-vision light-module batch checks<\/h3>\n<p>A machine-vision illuminator burn-in gantry may assess one matching 24V or 48V S-3000 output for fixed-voltage assemblies with a documented aggregate load. Confirm the module interface, branch protection and thermal duty. No constant-current LED driving, dimming, exposure synchronization or inspection accuracy is provided by implication; those functions need their own specified circuitry. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.<\/p>\n<h3>Industrial printer-mechanism batch tests<\/h3>\n<p>An industrial printer-mechanism assembly test conveyor may assess S-3000-24 for compatible 24V DC product inputs. Establish the batch load budget, start demand, harness losses and continuous duty before selection. Product functions and test sequences require independent controls; the conveyor drive, heaters and facility mains are not assigned to this supply. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.<\/p>\n<h2>S-3000 technical FAQs<\/h2>\n<h3>Which exact output models are listed?<\/h3>\n<p>S-3000-24: 24V 0~125A; S-3000-27: 27V 0~111A; S-3000-36: 36V 0~83A; S-3000-48: 48V 0~62.5A. These are separate model choices, not simultaneous outputs. The lower bound of each printed range is zero; that alone does not establish minimum-load behaviour or a complete continuous-duty specification.<\/p>\n<h3>Does the 3000W class label guarantee continuous power in my enclosure?<\/h3>\n<p>No. The summary states 3000W for the family, while each output column has its own printed current range. The sheet does not define the continuous-load relationship to ambient temperature, airflow, mounting or adjustment. The printed ranges do not establish a continuous-power rating calculated from voltage times current.<\/p>\n<h3>What input range and selection method are documented?<\/h3>\n<p>The stated input is 200~264VAC. No input frequency, DC range, low-line switching band or three-phase connection is specified. Obtain the exact unit\u2019s input connection details before installation.<\/p>\n<h3>What cold-start current must the upstream design consider?<\/h3>\n<p>The listed cold-start current is 70A at 230VAC. It is not a normal running-current figure and no second input condition is supplied. Coordinate the actual circuit and starting sequence rather than extrapolating this value to every input voltage.<\/p>\n<h3>What are the setup, rise and hold-up times?<\/h3>\n<p>Setup is 2000ms, rise is 50ms and hold-up is 20ms at 230VAC and full load, in that order. These values do not establish the response at another input voltage, a different load or during overload recovery.<\/p>\n<h3>What ripple\/noise values should be used for selection?<\/h3>\n<p>S-3000-24: 240mVp-p; S-3000-27: 240mVp-p; S-3000-36: 300mVp-p; S-3000-48: 300mVp-p. Measurement bandwidth, probing and load conditions are not given. Validate compatibility with sensitive loads using the agreed test method.<\/p>\n<h3>How are stability and efficiency specified?<\/h3>\n<p>The line-stability and load-stability rows each print \u00b10.5% for all four models. S-3000-24: 80%; S-3000-27: 82%; S-3000-36: 85%; S-3000-48: 87%. Efficiency measurement conditions are not stated; these entries do not prove system-level heat rejection.<\/p>\n<h3>How much voltage adjustment is shown?<\/h3>\n<p>The visible table shows \u00b110% DC-voltage adjustment for each selected model. Check device voltage tolerance and permitted current at the chosen setting. Adjustment does not establish a programmable control interface, constant-power operation or interchangeability with another model.<\/p>\n<h3>What overload behaviour is stated?<\/h3>\n<p>The threshold is 105%~135%, with output cut-off and automatic recovery. No permissible fault duration, recovery waveform or additional short-circuit\/overvoltage action is stated. Engineer external protection and safe restart independently.<\/p>\n<h3>What do the temperature and insulation entries establish?<\/h3>\n<p>Working temperature is listed as \u221210\u00b0C~+50\u00b0C without a derating curve or airflow requirement. Withstand values are 1.5kV input-to-output, 1.5kV input-to-frame and 0.5kV output-to-frame for one minute; AC\/DC waveform is not specified. Isolation resistance is listed as 100M\u03a9 at 500VDC for those pairs. These tests do not authorize a common-ground or output-strapping arrangement.<\/p>\n<h3>What mechanical and shipping information is available?<\/h3>\n<p>The table lists 291\u00d7132\u00d7136mm, 5.3kg and packing 38\u00d737.5\u00d721CM\/2PCS\/11kg. The drawing shows a 291mm chassis span, 132mm depicted face\/span and 30mm post projection, but does not separately dimension the table\u2019s 136mm extent. Verify mounting reference points, actual orientation, terminal clearances and service space before approving fit.<\/p>\n<h3>Can I wire the equipment from the outline drawing alone?<\/h3>\n<p>The input drawing has five screw symbols, with only the middle three numbered 1, 2 and 3; it provides no L\/N\/FG function legend. The output end shows POS(+)\/+V, NEG(\u2212)\/\u2212V and LED with additional contact symbols. Confirm the actual input functions, output-contact relationship, bonding, conductor sizes, torque and branch protection; do not infer strapping from the drawing.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"Specifications&amp;Model Specification S-3000-24 S-3000-27 S-3000-36 S-3000-48 DC output voltage,current 24V 0 ~ 125A 27V 0 ~ 111A 36V 0 ~ 83A 48V 0 ~ 62.5A Wave and noise 240mVp-p 240mVp-p 300mVp-p 300mVp-p Inlet wire stability \u00b10.5% \u00b10.5% \u00b10.5% \u00b10.5% Load stability \u00b10.5% \u00b10.5% \u00b10.5% \u00b10.5% Efficiency 80% 82% 85% 87% Adjustable range for DC voltage&hellip; <a class=\"more-link\" href=\"https:\/\/www.wehopower.com\/es\/product\/s-3000w-series-normal-single-switching-power-supply\/\">Continuar leyendo <span class=\"screen-reader-text\">Serie S-3000W fuente de alimentaci\u00f3n de conmutaci\u00f3n simple normal<\/span><\/a>","protected":false},"author":1,"featured_media":21177,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[35,36],"product_categories_new":[126],"class_list":["post-1146","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-enclosed-switching-power-supply","product_category-s-series-single-output-power-supply","product_categories_new-s-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/product\/1146","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/comments?post=1146"}],"version-history":[{"count":2,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/product\/1146\/revisions"}],"predecessor-version":[{"id":21810,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/product\/1146\/revisions\/21810"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/media\/21177"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/media?parent=1146"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/product_category?post=1146"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/www.wehopower.com\/es\/wp-json\/wp\/v2\/product_categories_new?post=1146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}