An EMI level is interpretable only with its detector, bandwidth, measurement conditions and applicable limit. A lower average-detector reading can still exceed its own limit while a higher quasi-peak reading remains below a different limit at the same frequency.
Key engineering takeaways
- Associate every reported level with its detector.
- Compare quasi-peak and average results to their respective limits.
- Preserve timing, bandwidth and operating-state evidence.
- Treat a pre-scan as evidence within its actual scope.

What should the OEM learn from a detector comparison?
The useful engineering decision is whether the report contains the required measurement and correct comparison for the intended equipment assessment. A screenshot showing one trace below one line cannot answer every conducted-emission question. The receiver configuration and the selected requirement must remain identifiable.
For an NDR-120-24 equipment review, identify the actual supply, host equipment, load and tested ports. A component photograph does not establish an equipment emission result. Neither an article example nor a family description proves that the complete assembly satisfies a particular standard.
The existing conducted-emission report review addresses report scope and classification evidence. This article examines the narrower detector-to-limit relationship. Keep the applicable standard, edition and laboratory decision rule with the real assessment instead of selecting a convenient limit from an unrelated example.
Why can the same signal produce several reported levels?
An EMI receiver processes the incoming signal through a defined measurement chain. The detector determines how that signal is weighted over time. Peak, quasi-peak and average labels therefore describe different measurement operations rather than interchangeable names for one numerical result.
Rohde & Schwarz's precompliance application note describes detector modes and defined bandwidths as part of EMI measurement. Record the actual settings used for each result. Do not compare two numbers as if detector selection were the only change when their bandwidth, observation time or equipment state also differs.
Quasi-peak weighting responds to pulse behavior through defined charging and discharging characteristics. An EMI average measurement addresses a different weighting operation. Neither can be reconstructed reliably by reading a peak marker and subtracting a generic fixed number of decibels.
An ordinary arithmetic average of displayed decibel samples is also not automatically the specified EMI average detector. Preserve the exact receiver mode and its applicable documentation. A software trace labeled “average” needs enough configuration detail to establish which averaging operation actually produced it.
A hypothetical report with opposite comparison outcomes
Assume an engineering worksheet evaluates one frequency at 400 kHz using two invented illustrative limits: 60 dBµV for a quasi-peak result and 50 dBµV for an EMI average result. These are not quoted standard limits, WEHO results or a declaration of compliance. Ignore measurement uncertainty for this arithmetic demonstration only.
Define worksheet margin as applicable limit minus reported level, so a positive number means the assumed level is below that assumed line. In case A, suppose the quasi-peak entry is 57 dBµV and the average entry is 52 dBµV. Their separate margins are 60 − 57 = +3 dB and 50 − 52 = −2 dB.
The average level is numerically lower than the quasi-peak level, yet its comparison is unfavorable. Comparing 52 dBµV with the 60 dBµV quasi-peak line would incorrectly report an 8 dB margin. The correct hypothetical average comparison is 2 dB above its own 50 dBµV line.
| Hypothetical record at 400 kHz | Quasi-peak: level / margin | Average: level / margin | Worksheet interpretation |
|---|---|---|---|
| Case A | 57 dBµV / +3 dB | 52 dBµV / −2 dB | Average comparison exceeds its assumed line |
| Case B | 59 dBµV / +1 dB | 48 dBµV / +2 dB | Both assumed comparisons are below their lines |
| Peak-only pre-scan | No quasi-peak result supplied | No average result supplied | Do not invent the missing detector results |
Swipe horizontally on a small screen, or open the full-size diagram.
For a unit check, dBµV = 20 × log10(V/1 µV). The assumed 60 dBµV line corresponds to 1,000 µV, while 50 dBµV corresponds to about 316.2 µV. This conversion reinforces that the two lines represent different voltage levels; a single convenient threshold cannot be substituted for both.
The table makes only the stated arithmetic comparisons. A real laboratory's uncertainty treatment and decision rule can affect its reported conclusion, particularly near a limit. A +1 dB worksheet margin is not by itself a certification result, nor proof that another configuration or operating mode will remain below a required line.
What can a peak pre-scan tell the reviewer?
A peak scan can help locate candidate frequencies for further evaluation. Its interpretation depends on the measurement method, bandwidth, signal behavior and the comparison being made. A peak crossing does not automatically establish the corresponding quasi-peak or average outcome.
Keysight's conducted-emission example explicitly pairs quasi-peak and average results with their respective lines. Its historical standard names and setup example are not adopted here as current requirements. Use the applicable method for the actual product and market, with a competent laboratory determining the required assessment.
Conversely, a favorable preliminary trace cannot fill missing documentation. If a method permits a conservative detector substitution, record the basis, bandwidth and conditions that make it valid. Do not turn that conditional possibility into an unrestricted claim that any peak-only screen completes every EMI requirement.
Retain scan and final-measurement states separately. A later measurement may use another detector or dwell time, while a development change may alter the equipment itself. A comparison is useful only when the record shows which differences were intentional and which quantities remain comparable.
Why do time and operating state matter?
An emission associated with a repeating machine action can be missed or weighted differently when observation does not capture the relevant behavior. Record the operating mode, load cycle and acquisition duration. A low reading from an idle state does not establish the result during the intended activity.
را Rohde & Schwarz ESPI operating manual distinguishes measurement time from settling behavior and explains detector-dependent timing. Those instructions are instrument-specific. They support checking the actual receiver and method rather than copying a universal dwell time into an OEM requirement.
Also retain correction factors, connection configuration and overload checks required by the chosen method. A detector comparison does not repair an invalid input chain. Qualified personnel should manage mains-connected test equipment and its protective arrangements under the laboratory's procedures; this guide is a report-interpretation method, not a LISN wiring instruction.
| Record field | Required relationship | Useful verification | Unresolved shortcut |
|---|---|---|---|
| Detector and result | Each numerical entry names its exact detector | Match report row to receiver configuration | Unlabeled screenshot peak |
| Limit and method | Line matches detector, port and applicable assessment | Check controlled method and edition | One imported line used for every trace |
| Bandwidth and timing | Settings support the detector and signal behavior | Review actual setup and observation interval | Default settings accepted without scope |
| Equipment state | Result covers the identified configuration and activity | Trace model, load, mode and revision | Component label presented as system evidence |
Build a detector-specific review record
- Identify the assessment. Record equipment, revision, tested port and applicable method. Verify that the requested evidence concerns this actual assembly rather than a different component or configuration.
- Map each result. Record frequency, detector, level, units and associated limit. Verify that the correct line is selected before calculating any margin or copying a pass label.
- Check the measurement conditions. Record bandwidth, timing, operating cycle and correction configuration. Verify that the relevant event was observed using the actual instrument's documented method.
- Separate preliminary and final evidence. Record pre-scan findings and subsequent detector measurements distinctly. Verify any permitted substitution from its applicable basis; do not fabricate missing results.
- Apply the declared decision rule. Record uncertainty handling, exceptions and the scope of the conclusion. Accept the report only when the required comparisons are supported, leaving unrelated system or market claims outside that result.

Prepare an NDR-120-24 EMC evidence enquiry
Send WEHO the NDR-120-24 candidate reference, host configuration, load, intended market and the exact documentation question. Include the detector-specific report rows if interpreting an existing test. Request applicable model evidence without presenting that evidence as automatic approval of the complete equipment.
Before the next review, label the detector, attach its correct comparison line and retain the operating conditions. Those actions make the reported margin traceable while keeping precompliance observations, formal laboratory conclusions and product photographs in their proper roles.
Engineering FAQ
Can an average result be lower yet fail its comparison?
Yes. An average result can exceed its own lower applicable limit while a higher quasi-peak result remains below another limit. Compare each detector's result to its associated line rather than ranking the levels alone.
Is an average of displayed dB values an EMI average result?
No. The specified detector operation and an arithmetic average of decibel readings are different procedures. Identify the actual instrument mode, weighting and method before treating a software average as the required EMI quantity.
Does a peak pre-scan crossing automatically prove quasi-peak failure?
No. It identifies a condition requiring interpretation or further measurement within the applicable method. The quasi-peak and average outcomes must be supported by their measurements or an explicitly valid substitution, not assumed from the peak label alone.
Are the 60 and 50 dBµV example lines legal limits for this supply?
No. They are invented worksheet inputs used to explain detector-specific comparisons. The actual product, installation, port, market and applicable assessment determine which documented requirements and decision rule must be used.