{"id":19034,"date":"2026-10-12T16:44:11","date_gmt":"2026-10-12T08:44:11","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/"},"modified":"2026-10-12T16:44:11","modified_gmt":"2026-10-12T08:44:11","slug":"xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/fa\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/","title":{"rendered":"XLG Waterproof LED Driver Sizing: Match the Load and Resolve the Installation Revision"},"content":{"rendered":"<p>Sizing a waterproof XLG LED driver starts with the electrical load and ends with the complete installation. Procurement teams should not choose by wattage and an IP marking alone. The required output behaviour, simultaneous fixture demand, input conditions and protected connections must all describe the same proposed system.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0641\u0647\u0631\u0633\u062a \u0645\u0637\u0627\u0644\u0628<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u062a\u063a\u06cc\u06cc\u0631 \u0648\u0636\u0639\u06cc\u062a \u062f\u0647\u06cc\u062f<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/fa\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/#Confirm_constant-voltage_operation_first\" >Confirm constant-voltage operation first<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/fa\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/#Build_a_load_schedule_not_a_single_guess\" >Build a load schedule, not a single guess<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/fa\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/#Check_the_source_and_the_load_ends_separately\" >Check the source and the load ends separately<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/fa\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/#%E2%80%9CWaterproof%E2%80%9D_is_not_the_whole_assembly_specification\" >\u201cWaterproof\u201d is not the whole assembly specification<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/fa\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/#Resolve_the_mechanical_revision_before_tooling\" >Resolve the mechanical revision before tooling<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/fa\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/#Record_an_auditable_purchasing_decision\" >Record an auditable purchasing decision<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/fa\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/#Frequently_asked_questions\" >Frequently asked questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/fa\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/#Does_a_100_W_family_name_mean_exactly_100_W_for_every_output_model\" >Does a 100 W family name mean exactly 100 W for every output model?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/fa\/news\/xlg-waterproof-led-driver-sizing-match-the-load-and-resolve-the-installation-revision\/#Is_the_IP67_marking_enough_to_approve_an_outdoor_installation\" >Is the IP67 marking enough to approve an outdoor installation?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Confirm_constant-voltage_operation_first\"><\/span>Confirm constant-voltage operation first<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>\u0631\u0627 <a href=\"https:\/\/www.wehopower.com\/fa\/product\/ac-dc-12v-24v-36v-48v-led-driver-100w-constant-voltage-waterproof-ip67-switching-power-supply\/\">official WEHO XLG-100 page<\/a> describes a constant-voltage family and identifies XLG-100-24 at 24 V, 4.2 A, with 100.8 W in its output table. The authentic specimen carries the same model and output marking. It is not evidence that an arbitrary bare LED string can be connected as a constant-current load.<\/p>\n<figure><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/03-product-detail-46.png?quality=85&strip=all\" alt=\"XLG Waterproof LED Driver Sizing: Match the Load and Resolve the Installation Revision  title=\" width=\"1536\" height=\"1024\" xlg waterproof led driver sizing: match the load and resolve installation revision title=\"\"><figcaption>\u72ec\u7acb\u6280\u672f\u6838\u9a8c\u901a\u8fc7 \u00b7 Original XLG-100-24 product photograph, cropped only above the physical unit to remove separate framing branding and uniformly resized. This is source evidence, not an installed or tested lighting system.<\/figcaption><\/figure>\n<p>The page also contains a row headed \u201cconstant current range.\u201d Do not turn that ambiguous row into a promised operating curve or an extra control mode. Confirm the current revision and the lighting product&#8217;s required supply type with the supplier. A model name is useful only when its electrical behaviour matches the actual fixture.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/01-application-a-49.png?quality=85&strip=all\" alt=\"XLG Waterproof LED Driver Sizing: Match the Load and Resolve the Installation Revision  title=\" width=\"1536\" height=\"1024\" xlg waterproof led driver sizing: match the load and resolve installation revision title=\"\"><figcaption>\u72ec\u7acb\u6280\u672f\u6838\u9a8c\u901a\u8fc7 \u00b7 Conceptual functional indoor-sign lighting illustration using a source-specific conditional 24 V branch and protected factory-jacket routing. Illuminated LEDs do not represent an unpowered fit stage, measurement, customer commissioning result or proven fixture compatibility. The order-specific header revision remains unresolved.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Build_a_load_schedule_not_a_single_guess\"><\/span>Build a load schedule, not a single guess<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>List each compatible lighting branch, its documented demand, quantity and operating pattern. Distinguish an illuminated sign operating continuously from zones that are switched separately. Add all loads that can run simultaneously, including any genuinely associated electronics. Do not assume that lighting branches remain separate simply because they occupy different physical parts of a sign.<\/p>\n<p>For a purely illustrative calculation, four compatible 24 V branches drawing 0.6 A each total 2.4 A. That example does not establish the consumption of a particular fixture, a tested XLG assembly or a required universal percentage margin. Use actual fixture data and an engineering allowance appropriate to the operating conditions and anticipated changes.<\/p>\n<p>Keep the continuous budget separate from startup and control transitions. Ask for the information needed to assess those conditions rather than interpreting a protective response as normal usable capacity. If the available fixture data is incomplete, the sizing decision remains conditional; a larger model name does not supply the missing evidence.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Check_the_source_and_the_load_ends_separately\"><\/span>Check the source and the load ends separately<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The photographed XLG-100-24 label states INPUT 95\u2013264 VAC 2.2 A 50\/60 Hz and OUTPUT +24 V with the original DC line symbol, 4.2 A. The frequency range given elsewhere in the specification is not a replacement inscription for the nameplate. Preserve each source&#8217;s meaning rather than editing the physical label to match a table.<\/p>\n<p>Have the electrical designer review the project&#8217;s actual input source, circuit and applicable operating conditions. Do not infer identical usable output at every input and temperature from a headline input range. On the output side, assess connection losses and the voltage delivered to each fixture, particularly when branches extend to different areas of a sign or building-lighting assembly.<\/p>\n<p>Describe the distribution and service isolation clearly. The driver does not decide how an installer protects every branch or identifies a failed fixture. Cable selection, protection and mains work require the matched documentation and qualified personnel; this article does not prescribe conductor sizes or protective-device values.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/02-application-b-47.png?quality=85&strip=all\" alt=\"XLG Waterproof LED Driver Sizing: Match the Load and Resolve the Installation Revision  title=\" width=\"1536\" height=\"1024\" xlg waterproof led driver sizing: match the load and resolve installation revision title=\"\"><figcaption>\u72ec\u7acb\u6280\u672f\u6838\u9a8c\u901a\u8fc7 \u00b7 Distinct dry wall-wash lighting service-module pretermination fit\/access concept with dark fixture optics, genuine integral flange\/deck contact and the original two factory jackets. Not completed wiring, an energized test or an accepted order-specific installation.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"%E2%80%9CWaterproof%E2%80%9D_is_not_the_whole_assembly_specification\"><\/span>\u201cWaterproof\u201d is not the whole assembly specification<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The real specimen carries IP67. That marking does not establish the protection of an external joint, enclosure entry or installed lighting system. Identify the actual exposure and the connection method before approving a project drawing. An indoor dry service compartment and an exposed outdoor joint are different design situations, even when they use the same marked driver.<\/p>\n<p>Keep factory cable exits mechanically supported and do not add a dimming cable or terminal block that the source specimen does not have. The inspected unit uses fixed cable tails at opposite ends and flange fixing, not DIN-rail mounting. Its ribbed casing is not permission to place it against insulation or declare every mounting orientation thermally acceptable.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Resolve_the_mechanical_revision_before_tooling\"><\/span>Resolve the mechanical revision before tooling<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The complete drawing explicitly distinguishes a 166 mm body from a 190 mm overall span to the outer mounting-ear ends, with 49 mm width. The dimension row gives 34 mm height. Each cable tail is separately marked 180 \u00b1 20 mm, followed by a 30 mm stripped section; those tails are not included in the 190 mm mounting envelope.<\/p>\n<p>The general-table heading nevertheless says 170 \u00d7 49 \u00d7 34 mm. No 170 mm body dimension is identified in the drawing, so this is still an unresolved revision discrepancy\u2014not \u201c170 mm plus cables equals 190 mm.\u201d The public page states 190 mm, but it does not close the delivered-unit revision. The scene concepts follow the documented flange\/body relationship, not an approved installation or hole-drilling template.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/04-engineering-context-50.png?quality=85&strip=all\" alt=\"XLG Waterproof LED Driver Sizing: Match the Load and Resolve the Installation Revision  title=\" width=\"1536\" height=\"1024\" xlg waterproof led driver sizing: match the load and resolve installation revision title=\"\"><figcaption>\u72ec\u7acb\u6280\u672f\u6838\u9a8c\u901a\u8fc7 \u00b7 Source-document evidence map, not wiring or supplier clarification: 166 mm body, 190 mm outer mounting ears and separately dimensioned cables; the 170 mm header remains unresolved.<\/figcaption><\/figure>\n<p>Request a corrected, model-matched drawing before releasing mounting holes or a tight compartment. Confirm the real flange positions, cable space and access. Separating this mechanical question from the electrical load budget prevents a correctly sized output from being mistaken for an installation-ready order.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Record_an_auditable_purchasing_decision\"><\/span>Record an auditable purchasing decision<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The RFQ should include the exact model, compatible fixture information, simultaneous-load schedule, actual input, environment, connection requirements and matched mechanical revision. Keep measured commissioning results separate from nominal ratings. Purchasing can then compare proposals on the same basis without inventing certification, waterproofing or fixture-compatibility conclusions.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Frequently_asked_questions\"><\/span>Frequently asked questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"Does_a_100_W_family_name_mean_exactly_100_W_for_every_output_model\"><\/span>Does a 100 W family name mean exactly 100 W for every output model?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Use the selected model&#8217;s documented voltage and current rather than treating the family headline as the full rating.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Is_the_IP67_marking_enough_to_approve_an_outdoor_installation\"><\/span>Is the IP67 marking enough to approve an outdoor installation?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. The complete equipment, joints and installation conditions need their own assessment.<\/p>","protected":false},"excerpt":{"rendered":"<p>A source-specific sizing guide that separates voltage-fed lighting demand, input conditions and external connection protection from an unresolved mechanical revision.<\/p>","protected":false},"author":2,"featured_media":19030,"parent":0,"menu_order":2,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[149,284],"class_list":["post-19034","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-blog","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/fa\/wp-json\/wp\/v2\/news\/19034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/fa\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/fa\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fa\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fa\/wp-json\/wp\/v2\/comments?post=19034"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/fa\/wp-json\/wp\/v2\/news\/19034\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fa\/wp-json\/wp\/v2\/media\/19030"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/fa\/wp-json\/wp\/v2\/media?parent=19034"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/fa\/wp-json\/wp\/v2\/news_category?post=19034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}