The WEHO NDR-960 is a high-performance 960W single-phase DIN rail power supply, engineered for industrial applications demanding high reliability and efficiency. It is available in 24V and 48V output models, both featuring a high efficiency of 92% and a wide operating temperature range of -30°C to +70°C, cooled by natural convection.

Designed for durability and safety, the NDR-960 complies with international safety standards including UL508 and TUV BS EN/EN62368-1.[1] It features comprehensive protection against overload, overvoltage, and over-temperature, ensuring robust operation in harsh environments.[2] With a peak load capability of 1250W for 3 seconds, it can handle demanding start-up loads. The slim, space-saving design for TS35/7.5 or TS35/15 DIN rails makes it an ideal and dependable power solution for industrial control systems, factory automation, and other critical equipment.

Modèle NDR-960-24 NDR-960-48
Sortir DC Voltage 24V 48V
DC Current 40A 20A
Current Range 0~40A 0~20A
Puissance nominale 960W 960W
Peak current 52A 26A
Peek Power 1250W(3s)
Ripple and Noise (Max) 240mVp-p 480mVp-p
Voltage adjustment range 24~28V 48~55V
Précision de la tension ±1,0% ±1,0%
Régulation de ligne ±0,5% ±0,5%
Régulation de charge ±2.0% ±2.0%
Start-up and rise time  Less than 3S, less than 300ms/230VAC (at full load)
Holding time (Typ.)  Greater than 10.5ms/230VAC (at full load)
Saisir Plage de tension  200~264VAC      285-370VDC
Gamme de fréquence  47~63Hz
Power Factor(Typ.)  PF≥0.95/230VAC (at full load)
Efficiency (Typ.) 92% 92%
Alternating current (Typ.)  6A/230VAC
Surge current (Typ.)  Cold start 80A/230VAC
Courant de fuite  <3.5mA/240VAC
Protéger Overload  Normally operates within 105-130% of the rated output for more than 3 seconds, then shuts off the output voltage, and automatically recovers within 30 seconds after the peak load is removed
 Protection mode: Constant current limit within 130-150% of rated output, output voltage is turned off after 3 seconds, and restarts to recover
Overvoltage 29~34V 56~65V
 Protection mode: turn off the output voltage, automatically recover or restart to recover
Surchauffe  95℃±15℃(TSW) detection of heat sink for power switch
 Protection mode: shut down the output voltage, and automatically recover when the temperature drops.

 

Quels sont les meilleurs produits d’alimentation électrique pour votre entreprise ?

Boostez votre entreprise avec les produits d'alimentation électrique de qualité WEHO.

Demandez à un expert
#!trpst#trp-gettext data-trpgettextoriginal=658#!trpen#Seraphinite Accelerator#!trpst#/trp-gettext#!trpen##!trpst#trp-gettext data-trpgettextoriginal=659#!trpen#Optimized by #!trpst#trp-gettext data-trpgettextoriginal=658#!trpen#Seraphinite Accelerator#!trpst#/trp-gettext#!trpen##!trpst#/trp-gettext#!trpen#
#!trpst#trp-gettext data-trpgettextoriginal=660#!trpen#Turns on site high speed to be attractive for people and search engines.#!trpst#/trp-gettext#!trpen#