{"id":17120,"date":"2026-09-01T23:32:01","date_gmt":"2026-09-01T15:32:01","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=news&#038;p=17120"},"modified":"2026-10-19T12:22:33","modified_gmt":"2026-10-19T04:22:33","slug":"power-supply-derating-guide","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/fr\/news\/power-supply-derating-guide\/","title":{"rendered":"Power Supply Derating: Temperature, Altitude, and Mounting"},"content":{"rendered":"<div class=\"weho-blog-content\" id=\"weho-article-07\" data-weho-article-id=\"07\">\n<p class=\"direct-answer\">Power supply derating determines the continuous output available under the actual temperature, altitude, input, mounting, and cooling conditions. Read the exact model&#8217;s curves and notes, convert each applicable limit into the same output unit, and follow its rule for simultaneous conditions. A working-temperature range does not promise full output across that range. Keep the resulting continuous ceiling separate from load margin, startup demand, and over-temperature shutdown.<\/p>\n<figure class=\"scene-hero\" id=\"application-scene-07\"><a href=\"https:\/\/www.wehopower.com\/fr\/product\/ndr-dinrail-240w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"View WEHO NDR-240-24 product details\" title=\"NDR-240-24 product details\" data-weho-link-kind=\"product_detail\" data-weho-link-role=\"product_image\" data-weho-model=\"NDR-240-24\" class=\"weho-product-image-link\"><picture><source type=\"image\/webp\" srcset=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/07-scene-960.webp?quality=85&#038;strip=all 960w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/07-scene.webp?quality=85&#038;strip=all 1672w\" sizes=\"(max-width:760px) calc(100vw - 36px), 760px\"><img fetchpriority=\"high\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/07-scene.webp?quality=85&#038;strip=all\" width=\"1672\" height=\"941\" alt=\"Power Supply Derating: Temperature, Altitude, and Mounting  title=\" loading=\"eager\" decoding=\"async\" power supply derating: and mounting title =\"\"><\/picture><\/a><figcaption>AI-assisted application illustration; not a customer installation or thermal test.<span class=\"weho-image-actions\" data-weho-image-actions=\"1\"><span class=\"weho-image-hint\">NDR-240-24 \u00b7 Select image for product details.<\/span><a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/07-scene.png\" target=\"_blank\" rel=\"noopener noreferrer\" data-weho-link-role=\"view_original\">View larger image \u2197<\/a><\/span><\/figcaption><\/figure>\n<details class=\"article-toc\" open>\n<summary>Table des mati\u00e8res<\/summary>\n<nav class=\"toc-links\" aria-label=\"Article sections\"><a href=\"#define-operating-point-before-curve\">Define the operating point before reading a curve<\/a><a href=\"#read-axes-notes-and-units\">Read the axes, conditions, and usable region together<\/a><a href=\"#mounting-and-cooling-change-output\">Mounting and cooling are part of the rating<\/a><a href=\"#include-altitude-in-the-operating-point\">Include altitude in the thermal and insulation check<\/a><a href=\"#worked-continuous-output-example\">Worked example: 300 W nominal becomes a 220 W ceiling<\/a><a href=\"#keep-transients-and-protection-separate\">Keep continuous derating separate from startup and shutdown<\/a><a href=\"#request-model-operating-point-data\">Start with the operating conditions for a WEHO candidate<\/a><\/nav>\n<\/details>\n<section id=\"define-operating-point-before-curve\">\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table des mati\u00e8res<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Basculer<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-derating-guide\/#Define_the_operating_point_before_reading_a_curve\" >Define the operating point before reading a curve<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-derating-guide\/#Read_the_axes_conditions_and_usable_region_together\" >Read the axes, conditions, and usable region together<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-derating-guide\/#Mounting_and_cooling_are_part_of_the_rating\" >Mounting and cooling are part of the rating<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-derating-guide\/#Include_altitude_in_the_thermal_and_insulation_check\" >Include altitude in the thermal and insulation check<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-derating-guide\/#Worked_example_300_W_nominal_becomes_a_220_W_ceiling\" >Worked example: 300 W nominal becomes a 220 W ceiling<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-derating-guide\/#Keep_continuous_derating_separate_from_startup_and_shutdown\" >Keep continuous derating separate from startup and shutdown<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-derating-guide\/#Start_with_the_operating_conditions_for_a_WEHO_candidate\" >Start with the operating conditions for a WEHO candidate<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Define_the_operating_point_before_reading_a_curve\"><\/span>Define the operating point before reading a curve<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Write down the complete model and output suffix, the lowest supply voltage expected at its input, the local temperature at the manufacturer&#8217;s defined reference point, and the installed orientation. Add enclosure arrangement, neighboring heat sources, cooling method, altitude, and continuous output demand. A derating value without these conditions is difficult to use in a design review.<\/p>\n<p>The relevant temperature is not automatically the room temperature or the cabinet door display. Air arriving at the supply may already have passed a drive, transformer, or another power supply. Follow the measurement location specified for the model. Do not substitute case temperature for ambient temperature unless the documentation explicitly uses case or baseplate temperature.<\/p>\n<p><a href=\"https:\/\/www.ia.omron.com\/product\/cautions\/22\/safety_precautions.html\" target=\"_blank\" rel=\"noopener noreferrer\">The referenced power-supply precautions<\/a> illustrate how temperature, mounting, and cooling affect the permitted loading. Apply that reading process to the candidate&#8217;s own curves and temperature reference point.<\/p>\n<\/section>\n<section id=\"read-axes-notes-and-units\">\n<h2><span class=\"ez-toc-section\" id=\"Read_the_axes_conditions_and_usable_region_together\"><\/span>Read the axes, conditions, and usable region together<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>First identify what the vertical axis represents: output current, output power, or percentage of a stated rating. Then identify the horizontal variable and the separate curves for input voltage, cooling, or mounting. Check whether the curve covers continuous operation or a time-limited boost. A short-duration overload allowance cannot replace the continuous thermal limit.<\/p>\n<div class=\"weho-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable comparison table\">\n<table>\n<caption>Translate the document into an available-output record<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Document item<\/th>\n<th scope=\"col\">What to record<\/th>\n<th scope=\"col\">What changes the result<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Temperature curve<\/th>\n<td>Defined temperature point, selected curve and permitted continuous output<\/td>\n<td>Different orientation, air path, adjacent heat or cooling arrangement<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Input limit<\/th>\n<td>Minimum input at the terminals, frequency or DC-input condition where applicable<\/td>\n<td>Low-line sag, a different input variant or a restricted input operating region<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Mounting note<\/th>\n<td>Allowed direction, specified clearances and any alternate-mounting restriction<\/td>\n<td>Rotating the supply or placing a duct across its airflow path<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cooling basis<\/th>\n<td>Natural convection, specified forced air, or baseplate temperature<\/td>\n<td>Fan deterioration, filter restriction or an unverified heat-transfer interface<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Altitude<\/th>\n<td>Installation elevation, permitted operating altitude, and any thermal or input restrictions<\/td>\n<td>Lower air density and a different insulation or cooling limit at the installation site<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Combination rule<\/th>\n<td>One combined curve, independent ceilings, or an explicit factor calculation<\/td>\n<td>Assuming different restrictions can be combined without instructions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Use interpolation only where the manufacturer permits it and where the curve is readable at the precision the decision needs. A point outside the documented region needs clarification; extending a straight line is not evidence of an allowed operating condition. Retain the source revision and the curve label with the result so another engineer can reproduce the reading.<\/p>\n<p>Input and output limits also need a common basis. If a limit is given in watts, the corresponding current at a specified output voltage is <strong>I = P \u00f7 V<\/strong>. Check the separate current rating and voltage-adjustment restrictions as well. An adjustable supply set above nominal voltage may reach its power limit before its nominal current limit.<\/p>\n<\/section>\n<section id=\"mounting-and-cooling-change-output\">\n<h2><span class=\"ez-toc-section\" id=\"Mounting_and_cooling_are_part_of_the_rating\"><\/span>Mounting and cooling are part of the rating<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A supply that fits sideways may not retain its standard-orientation output. This <a href=\"https:\/\/www.us.lambda.tdk.com\/resources\/blogs\/20111103.html\" target=\"_blank\" rel=\"noopener noreferrer\">manufacturer&#8217;s mounting guide<\/a> explains how orientation changes convection. Check which proposed positions the candidate permits and which output limit applies.<\/p>\n<p>The same distinction applies to \u201cfanless.\u201d Natural convection still requires an air path. A sealed cabinet can develop a local environment different from the test arrangement. A designed baseplate transfers heat through a defined conduction path, as explained in this <a href=\"https:\/\/www.xppower.com\/resources\/blog\/getting-heat-out-of-sealed-power-supply-enclosures\" target=\"_blank\" rel=\"noopener noreferrer\">sealed-enclosure cooling guide<\/a>. Bolting an ordinary metal case to a plate does not establish that cooling performance.<\/p>\n<p>When comparing <a href=\"https:\/\/www.wehopower.com\/fr\/news\/din-rail-vs-enclosed-power-supply\/\" data-weho-link-kind=\"guide\">DIN rail and chassis mounting formats<\/a>, retain cooling space in both layouts. A larger nominal wattage may be one option, but a different position, documented cooling method, or lower local temperature can be more effective. Evaluate each revision using its own evidence.<\/p>\n<\/section>\n<section id=\"include-altitude-in-the-operating-point\">\n<h2><span class=\"ez-toc-section\" id=\"Include_altitude_in_the_thermal_and_insulation_check\"><\/span>Include altitude in the thermal and insulation check<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>At higher altitude, check two engineering limits separately:<\/p>\n<ul>\n<li><strong>Cooling limit.<\/strong> Lower air density makes air cooling less effective. The exact model may require a reduced continuous load or a lower maximum local ambient temperature at the installation elevation.<\/li>\n<li><strong>Electrical insulation limit.<\/strong> Air also provides electrical insulation. Check the model&#8217;s permitted operating altitude and electrical-clearance restrictions; reducing output load alone does not establish adequate electrical clearances.<\/li>\n<\/ul>\n<p>A <a href=\"https:\/\/www.us.lambda.tdk.com\/resources\/blogs\/20121009.html\" target=\"_blank\" rel=\"noopener noreferrer\">manufacturer&#8217;s explanation of altitude effects<\/a> describes both mechanisms. Check the exact model&#8217;s maximum operating altitude, any altitude-related input or overvoltage-category restrictions, and its thermal derating instructions. Use the stated temperature correction, load factor, or combined curve where supplied. A threshold or percentage from another supply is not a WEHO rating. If the interaction is unspecified, ask for the permitted continuous output at the site&#8217;s altitude together with the input, local temperature, and cooling conditions.<\/p>\n<\/section>\n<section id=\"worked-continuous-output-example\">\n<h2><span class=\"ez-toc-section\" id=\"Worked_example_300_W_nominal_becomes_a_220_W_ceiling\"><\/span>Worked example: 300 W nominal becomes a 220 W ceiling<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Hypothetical calculation example:<\/strong> a 24 V, 300 W supply has a 12.5 A current rating. Assume its temperature-and-mounting limit is 80% of nominal power at the selected operating point. Also assume a separate 220 W low-input ceiling applies at that same point, with an explicit rule that the lower of these independent ceilings governs. These are teaching assumptions, not WEHO ratings.<\/p>\n<figure class=\"batch-figure\" id=\"guide-figure-07\"><picture><source media=\"(max-width:640px)\" type=\"image\/webp\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/guide-07-mobile.webp\" width=\"380\" height=\"709\"><source media=\"(max-width:640px)\" type=\"image\/png\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/guide-07-mobile.png\" width=\"380\" height=\"709\"><source type=\"image\/webp\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/guide-07-desktop.webp\"><img loading=\"lazy\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/guide-07-desktop.png?quality=85&#038;strip=all\" width=\"2240\" height=\"1508\" alt=\"Power Supply Derating: Temperature, Altitude, and Mounting  title=\" decoding=\"async\" power supply derating: and mounting title =\"\"><\/picture><figcaption>Hypothetical 300 W example: the lower independent ceiling governs only under the stated combination rule. The 90% project target is a separate assumption, not a WEHO rating.<\/figcaption><a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/guide-07-desktop.png\" target=\"_blank\" rel=\"noopener noreferrer\" class=\"relation-detail\">View full diagram<\/a><\/figure>\n<div class=\"weho-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable comparison table\">\n<table>\n<caption>Illustrative limits for one common operating point<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Step<\/th>\n<th scope=\"col\">Calculation<\/th>\n<th scope=\"col\">Result<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Thermal and mounting ceiling<\/th>\n<td>300 W \u00d7 0.80<\/td>\n<td>240 W<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Low-input ceiling<\/th>\n<td>Assumed separately confirmed limit<\/td>\n<td>220 W<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Available continuous power<\/th>\n<td>Minimum of 300 W, 240 W and 220 W<\/td>\n<td>220 W<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Current at 24 V<\/th>\n<td>220 W \u00f7 24 V<\/td>\n<td>9.17 A, rounded<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Application continuous load<\/th>\n<td>24 V \u00d7 8.5 A<\/td>\n<td>204 W<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Remaining power below the ceiling<\/th>\n<td>220 W \u2212 204 W<\/td>\n<td>16 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The load uses <strong>204 \u00f7 220 = 92.7%<\/strong> of the available continuous output, even though it uses only 68% of the 300 W nameplate power. That distinction matters when a purchasing comparison appears to show generous spare capacity.<\/p>\n<p>If the OEM requires continuous loading no higher than 90% of the derated ceiling, the allowed project load is <strong>220 W \u00d7 0.90 = 198 W<\/strong>. The 204 W load misses that project target by 6 W. The 90% value is an example design policy, not a universal power supply requirement. Choose a different candidate, improve the operating conditions, or revise the supported load requirement.<\/p>\n<p>This minimum rule only works under the assumed confirmation that the ceilings apply together. If a real document requires multiplicative factors or supplies a combined curve, use that method instead. If the interaction is unspecified, ask for the allowed continuous output at the combined operating point.<\/p>\n<\/section>\n<section id=\"keep-transients-and-protection-separate\">\n<h2><span class=\"ez-toc-section\" id=\"Keep_continuous_derating_separate_from_startup_and_shutdown\"><\/span>Keep continuous derating separate from startup and shutdown<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A continuous-output calculation does not settle startup compatibility. Check the amplitude, duration, and repetition of the DC load&#8217;s startup or transient demand against the exact supply&#8217;s output behavior. Separately assess <a href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-inrush-current-multiple-units\/\" data-weho-link-kind=\"guide\">AC input inrush when several supplies start together<\/a>. The DC current budget and the AC charging event are different requirements.<\/p>\n<p>Over-temperature protection is also a different function. A supply that has not tripped may still be operating outside its documented continuous region. Record expected steady output and relevant temperature limits before the test; absence of a shutdown is not a thermal acceptance criterion.<\/p>\n<p>Plan the cabinet trial around the assembled configuration: representative load states, minimum input, intended covers, actual fan\/filter arrangement, and the neighboring equipment that contributes heat. Record the local temperature and accessible manufacturer-specified case or component measurement points after conditions stabilize. Keep measurement uncertainty visible when the result is close to a boundary.<\/p>\n<\/section>\n<section id=\"request-model-operating-point-data\">\n<h2><span class=\"ez-toc-section\" id=\"Start_with_the_operating_conditions_for_a_WEHO_candidate\"><\/span>Start with the operating conditions for a WEHO candidate<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Start with the installation conditions, even if the model is still open. Once a candidate is identified, use its installation instructions and derating data to establish the continuous-output limit at that operating point.<\/p>\n<p>Keep the allowed load, document revision, measurement basis, and cabinet arrangement together. Recheck the result when a later machine revision moves the supply, changes cooling, increases load, or moves the equipment to a different altitude.<\/p>\n<p class=\"related-model-documents\">For the pictured NDR-240-24 reference, the <a href=\"https:\/\/www.wehopower.com\/fr\/product\/ndr-dinrail-240w-ac-to-dc-single-output-switching-power-supply\/\" data-weho-link-kind=\"product_detail\">NDR-240 product details<\/a> et <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/NDR-240.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" data-weho-link-kind=\"datasheet\">public NDR-240 specification<\/a> provide an identity and document starting point. Obtain the applicable installation and derating information before assigning an available output; the 300 W example is hypothetical.<\/p>\n<p class=\"article-cta\"><a href=\"https:\/\/www.wehopower.com\/fr\/contact\/\" data-weho-link-kind=\"inquiry\">Contact WEHO about model-specific derating<\/a>. Four inputs can start the inquiry: input voltage range; output voltage and load profile; local temperature and site altitude; and mounting orientation with the cooling arrangement. Add the full candidate model if known.<\/p>\n<\/section>\n<p class=\"worksheet-callout\">Optional project record: <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/weho-blog-batch2-2026-10-17-product-v4-07-power-supply-derating-operating-point.csv\" download=\"\" target=\"_blank\" rel=\"noopener noreferrer\" data-weho-link-kind=\"worksheet\">Download the derating operating-point sheet (CSV)<\/a>. Use it to record your own inputs and evidence; example entries are illustrative.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Read model-specific temperature, altitude, input, mounting, and cooling limits before treating nominal power as usable output. A hypothetical 300 W example separates a 220 W continuous ceiling from a project load target. The altitude section distinguishes thermal limits from electrical insulation.<\/p>","protected":false},"author":1,"featured_media":19448,"parent":0,"menu_order":397,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[149,148,284],"class_list":["post-17120","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-blog","news_category-industry-news","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news\/17120","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/comments?post=17120"}],"version-history":[{"count":3,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news\/17120\/revisions"}],"predecessor-version":[{"id":19638,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news\/17120\/revisions\/19638"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/media\/19448"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/media?parent=17120"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news_category?post=17120"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}