{"id":18510,"date":"2026-10-03T18:00:00","date_gmt":"2026-10-03T10:00:00","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=news&#038;p=18510"},"modified":"2026-10-05T10:52:54","modified_gmt":"2026-10-05T02:52:54","slug":"power-supply-cooling-fanless-cabinet-thermal-acceptance","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/","title":{"rendered":"Refroidissement de l'alimentation: acceptation thermique du cabinet sans ventilateur"},"content":{"rendered":"<p><strong>Derni\u00e8re mise \u00e0 jour:<\/strong> 3 octobre 2026<\/p>\n<p><strong>Quick r\u00e9ponse:<\/strong> Pour une armoire candidate sans ventilateur, l'acceptation du refroidissement de l'alimentation \u00e9lectrique devrait commencer par un plan d'essai contr\u00f4l\u00e9, et non par une affirmation g\u00e9n\u00e9rale selon laquelle le retrait d'un ventilateur rend l'armoire appropri\u00e9e. Enregistrer le mod\u00e8le et la r\u00e9vision exacts, le profil de charge, les conditions d'air locales, le montage et la configuration de l'armoire; convenir des limites applicables avant de mesurer. Conserver les preuves r\u00e9sultantes et examiner les modifications apport\u00e9es \u00e0 la disposition, \u00e0 la charge, ventilation ou entretien. Le WEHO DR-120 - 24 L'exemple illustr\u00e9 ici est un exemple de rail DIN 24 V, 5 A v\u00e9rifi\u00e9 par la source, et non une qualification thermique document\u00e9e d'une armoire scell\u00e9e ou un r\u00e9sultat d'essai mesur\u00e9.<\/p>\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/01-product-detail-5.png\" alt=\"Refroidissement de l&#039;alimentation \u00e9lectrique: Cabinet sans ventilateur Acceptation thermique titre =\" class=\"wp-image-18506\" loading=\"eager\" power supply cooling: fanless cabinet thermal acceptance title =\"\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/01-product-detail-5.png 1536w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/01-product-detail-5-300x200.png 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/01-product-detail-5-1024x683.png 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/01-product-detail-5-768x512.png 768w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/01-product-detail-5-18x12.png 18w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n<p>Un acheteur OEM enqu\u00eate <strong>Supply Cooling \u00e9lectrique<\/strong> besoin d'une r\u00e9ponse \u00e0 une question de lib\u00e9ration sp\u00e9cifique: l'unit\u00e9 command\u00e9e restera-t-elle dans ses conditions de fonctionnement document\u00e9es dans cette armoire et ce cycle de service particuliers? Une comparaison de catalogue entre les mod\u00e8les sans ventilateur et refroidis par ventilateur ne r\u00e9pond pas \u00e0 cette question.<\/p>\n<p>Ce guide est une liste de contr\u00f4le de planification de l'acceptation thermique pour l'\u00e9lectronique de commande auxiliaire. Il ne classe pas les technologies de refroidissement, ne promet pas de dur\u00e9e de vie ou ne fournit pas de courbe de r\u00e9duction. Les illustrations montrent une pr\u00e9paration m\u00e9canique d\u00e9connect\u00e9e; aucune ne repr\u00e9sente un essai thermique sous tension ou ne prouve la compatibilit\u00e9 avec les machines environnantes.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table des mati\u00e8res<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Basculer<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Freeze_the_sample_and_configuration_before_the_trial\" >Congeler l'\u00e9chantillon et la configuration avant l'essai<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Keep_room_temperature_separate_from_local_air_and_case_temperature\" >Maintenir la temp\u00e9rature ambiante s\u00e9par\u00e9e de l'air local et de la temp\u00e9rature du bo\u00eetier<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Use_the_exact_model_as_an_evidence_anchor\" >Utiliser le mod\u00e8le exact comme ancrage de preuve<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Write_limits_first_then_compare_the_evidence\" >\u00c9crire les limites d'abord, puis comparer les preuves<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Review_dust_exposure_maintenance_and_later_changes\" >Examiner l'exposition \u00e0 la poussi\u00e8re, l'entretien et les changements ult\u00e9rieurs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Key_Takeaways\" >Points cl\u00e9s \u00e0 retenir<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Conclusion\" >Conclusion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Frequently_Asked_Questions\" >Questions fr\u00e9quemment pos\u00e9es<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Is_this_another_fanless-versus-fan-cooled_comparison\" >Est-ce une autre comparaison fanless versus fan-cooled?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Does_the_DR-120-24_image_prove_a_sealed-cabinet_rating\" >L'image DR-120 - 24 prouve-t-elle une classification d'armoire scell\u00e9e?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Can_room_temperature_be_used_as_the_supplys_local_air_temperature\" >La temp\u00e9rature ambiante peut-elle \u00eatre utilis\u00e9e comme temp\u00e9rature de l'air local de l'alimentation?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#How_long_should_every_thermal_trial_run\" >Combien de temps doit durer chaque essai thermique?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#What_DR-120-24_derating_curve_is_supplied_here\" >Quelle courbe de d\u00e9ratation DR-120 - 24 est fournie ici?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#Do_the_moulding_and_baggage_images_show_measured_performance\" >Les images de moulage et de bagages montrent-elles des performances mesur\u00e9es?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.wehopower.com\/fr\/news\/power-supply-cooling-fanless-cabinet-thermal-acceptance\/#When_does_a_cabinet_change_need_reassessment\" >Quand un changement de cabinet doit-il \u00eatre r\u00e9\u00e9valu\u00e9?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Freeze_the_sample_and_configuration_before_the_trial\"><\/span>Congeler l'\u00e9chantillon et la configuration avant l'essai<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Donnez \u00e0 l'\u00e9valuation un enregistrement de configuration.Identifiez le mod\u00e8le complet, la r\u00e9vision et l'\u00e9chantillon; enregistrez l'\u00e9tat d'entr\u00e9e, le r\u00e9glage de sortie, les \u00e9tats de charge normaux et exigeants, l'orientation du montage et les composants voisins pertinents.Liez la sp\u00e9cification actuelle et les instructions d'installation plut\u00f4t que de vous fier \u00e0 une classification familiale m\u00e9moris\u00e9e.<\/p>\n<p>Enregistrez l'enceinte telle qu 'elle sera \u00e9valu\u00e9e: \u00e9tat de la porte, couvercles install\u00e9s, conduits de c\u00e2bles, ouvertures, filtres ou ventilation de l'armoire et voisins produisant de la chaleur. Un r\u00e9sultat de banc ouvert est une preuve de cette configuration de banc, pas une preuve automatique pour un panneau de production ferm\u00e9. Si le fonctionnement de la porte de service est un \u00e9tat de machine autoris\u00e9, \u00e9valuez-le comme une condition enregistr\u00e9e s\u00e9par\u00e9ment plut\u00f4t que de m\u00e9langer les configurations dans un seul r\u00e9sultat.<\/p>\n<p>Documenter l'incertitude dans les donn\u00e9es de charge. Un appareil de chauffage, un entra\u00eenement de moulage ou un moteur de convoyeur de bagages n'est pas suppos\u00e9 appartenir \u00e0 une alimentation de contr\u00f4leur de 24 V. V\u00e9rifier l'\u00e9lectronique auxiliaire r\u00e9elle et la demande de chevauchement \u00e0 partir de leurs sp\u00e9cifications ou mesures de s\u00e9curit\u00e9. Si le pire \u00e9tat est inconnu, ne remplacez pas un pourcentage appropri\u00e9 de la puissance plaque signal\u00e9tique et appelez-le la charge d'acceptation.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Keep_room_temperature_separate_from_local_air_and_case_temperature\"><\/span>Maintenir la temp\u00e9rature ambiante s\u00e9par\u00e9e de l'air local et de la temp\u00e9rature du bo\u00eetier<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>D\u00e9finissez les emplacements de mesure avant de collecter les donn\u00e9es. L'air ambiant, l'air proche de l'alimentation, l'air de l'enceinte et un point de bo\u00eetier externe d\u00e9crivent des conditions diff\u00e9rentes. Une pi\u00e8ce confortable peut coexister avec une poche plus chaude pr\u00e8s de l'\u00e9quipement voisin. De m\u00eame, une lecture de bo\u00eetier n'\u00e9tablit pas la temp\u00e9rature interne de chaque composant.<\/p>\n<p>Utiliser la m\u00e9thode de mesure et les emplacements requis par les documents contr\u00f4l\u00e9s ou le plan d'ing\u00e9nierie convenu. Enregistrer l'identit\u00e9 du capteur, l'emplacement, la fixation, le cas \u00e9ch\u00e9ant, l'incertitude et si la mesure elle-m\u00eame modifie l'acc\u00e8s ou le d\u00e9bit d'air. Le personnel qualifi\u00e9 doit g\u00e9rer l'acc\u00e8s \u00e9lectrique et l'instrumentation en toute s\u00e9curit\u00e9; ce guide n'indique pas \u00e0 quiconque de placer une sonde sur des pi\u00e8ces sous tension expos\u00e9es.<\/p>\n<p>Convenir de la fa\u00e7on dont la stabilisation thermique sera reconnue et document\u00e9e. Ne pas appliquer un temps d'attente fixe arbitraire \u00e0 chaque panneau. Un enregistrement utile pr\u00e9serve l'historique du temps, la charge et les conditions environnementales utilis\u00e9es pour la d\u00e9cision, ainsi que le crit\u00e8re de l'examinateur responsable. Sans un crit\u00e8re convenu, une seule photographie de temp\u00e9rature n'est pas un r\u00e9sultat d'acceptation en condition stable d\u00e9fendable.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Use_the_exact_model_as_an_evidence_anchor\"><\/span>Utiliser le mod\u00e8le exact comme ancrage de preuve<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Le <a href=\"https:\/\/www.wehopower.com\/fr\/product\/120w-single-output-din-rail-power-high-power-led-driver-120w\/\">Page produit WEHO DR-120<\/a> identifie le DR-120 - 24 \u00e0 24 V, 5 A et 120 W. Les sp\u00e9cifications m\u00e9caniques actuelles enregistrent <strong>65.5 mm largeur \u00d7 125,2 mm hauteur \u00d7 100 mm profondeur<\/strong>, Cette enveloppe exclut la ventilation suppl\u00e9mentaire, le c\u00e2blage et l'espace de service requis par les instructions d'installation command\u00e9es.<\/p>\n<p>La photographie de la source approuv\u00e9e montre un bo\u00eetier m\u00e9tallique ventil\u00e9 et aucun ventilateur visible. Elle n'\u00e9tablit pas un bo\u00eetier \u00e0 la poussi\u00e8re, une cote de bo\u00eete scell\u00e9e, un bruit \u00e9lectrique z\u00e9ro ou une limite thermique particuli\u00e8re. Confirmez les conditions de refroidissement et d'installation document\u00e9es de l'unit\u00e9 command\u00e9e. Ne d\u00e9duisez pas une courbe courant\/temp\u00e9rature admissible de l'absence d'un ventilateur ou des sp\u00e9cifications d'un autre mod\u00e8le.<\/p>\n<p>Conservez l'entr\u00e9e nominale de l'\u00e9tiquette de la source \u201c100 - 240VAC 3.3A\u201d et \u201c50\/60Hz\u201d s\u00e9par\u00e9ment de la table de fonctionnement 85 - 264 VAC et 47 - 63 Hz de la sp\u00e9cification actuelle. R\u00e9soudre la r\u00e9vision ordonn\u00e9e avant la lib\u00e9ration \u00e9lectrique. Cet article n'adopte pas de formulation d'entr\u00e9e de page publique conflictuelle ou ne convertit pas une image de source m\u00e9canique en preuve d'un point de fonctionnement thermique.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/02-injection-moulding-controls.png\" alt=\"Refroidissement de l&#039;alimentation \u00e9lectrique: Cabinet sans ventilateur Acceptation thermique titre =\" class=\"wp-image-18507\" power supply cooling: fanless cabinet thermal acceptance title =\"\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/02-injection-moulding-controls.png 1536w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/02-injection-moulding-controls-300x200.png 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/02-injection-moulding-controls-1024x683.png 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/02-injection-moulding-controls-768x512.png 768w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/02-injection-moulding-controls-18x12.png 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n<p>La premi\u00e8re sc\u00e8ne d'application concerne l'armoire de commande auxiliaire d'un constructeur d'\u00e9quipements de moulage par injection. La machine \u00e0 proximit\u00e9 \u00e9tablit le champ, mais l'alimentation d\u00e9connect\u00e9e n'alimente pas les chauffages du moule ou l'entra\u00eenement hydraulique. Le chauffage r\u00e9el de l'armoire, le cycle de service et la demande de charge de contr\u00f4le n\u00e9cessitent leur propre \u00e9valuation; une illustration d'assemblage ne fournit aucune de ces mesures.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Write_limits_first_then_compare_the_evidence\"><\/span>\u00c9crire les limites d'abord, puis comparer les preuves<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Le plan d'acceptation doit identifier les limites de sortie contr\u00f4l\u00e9es et les restrictions environnementales et d'installation pertinentes pour la r\u00e9vision command\u00e9e. Demander les informations manquantes du fabricant avant de r\u00e9gler une porte de d\u00e9verrouillage. Une plage de temp\u00e9rature de fonctionnement g\u00e9n\u00e9rique sans ses conditions de charge, de montage et de refroidissement ne suffit pas pour justifier chaque installation ferm\u00e9e.<\/p>\n<p>Indiquez ce qui sera observ\u00e9: les points de temp\u00e9rature convenus, la sortie aux charges de contr\u00f4le exigeantes, l'\u00e9tat de fonctionnement pertinent et tout comportement anormal dans les conditions d'essai d\u00e9finies. Pr\u00e9ciser comment les interruptions ou les changements de configuration sont enregistr\u00e9s. Une tension moyenne passante seule ne ferme pas une question thermique, et une fen\u00eatre d'indicateur n'est pas une mesure de temp\u00e9rature ind\u00e9pendante.<\/p>\n<p>N'inventez pas de limite de passage thermique, de pourcentage de d\u00e9gradation ou de temp\u00e9rature d'arr\u00eat lorsque les documents n'en fournissent aucun. Enregistrez la base manquante comme une action ouverte du fournisseur ou de l'ing\u00e9nierie. Si l'\u00e9chantillon effectue des cycles inattendus, r\u00e9initialise les charges ou pr\u00e9sente un comportement anormal, conservez ces preuves et enqu\u00eatez en toute s\u00e9curit\u00e9 plut\u00f4t que de supposer la cause ou de modifier le crit\u00e8re apr\u00e8s avoir vu le r\u00e9sultat.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/03-baggage-handling-controls.png\" alt=\"Refroidissement de l&#039;alimentation \u00e9lectrique: Cabinet sans ventilateur Acceptation thermique titre =\" class=\"wp-image-18508\" power supply cooling: fanless cabinet thermal acceptance title =\"\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/03-baggage-handling-controls.png 1536w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/03-baggage-handling-controls-300x200.png 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/03-baggage-handling-controls-1024x683.png 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/03-baggage-handling-controls-768x512.png 768w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/03-baggage-handling-controls-18x12.png 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n<p>La deuxi\u00e8me sc\u00e8ne est un atelier prot\u00e9g\u00e9 d'\u00e9quipement de manutention de bagages \u00e0 sec. Elle montre une station d'ajustement auxiliaire-contr\u00f4leur \u00e0 c\u00f4t\u00e9 d'un convoyeur de bagages arr\u00eat\u00e9, et non une installation a\u00e9roportuaire motoris\u00e9e. L'utilisation du candidat n'\u00e9tablit pas l'homologation a\u00e9ronautique, la s\u00e9curit\u00e9 de l'\u00e9quipement ou la capacit\u00e9 de propulsion du moteur. Les conditions de service et les exigences du syst\u00e8me responsable doivent \u00eatre v\u00e9rifi\u00e9es de mani\u00e8re ind\u00e9pendante.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Review_dust_exposure_maintenance_and_later_changes\"><\/span>Examiner l'exposition \u00e0 la poussi\u00e8re, l'entretien et les changements ult\u00e9rieurs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Sans ventilateur ne signifie pas sans ventilation ou sans entretien. Pour un candidat m\u00e9tal ventil\u00e9, \u00e9valuez l'exposition \u00e0 la contamination r\u00e9elle de l'armoire, la protection de l'enceinte et les dispositions d'entretien document\u00e9es. Ne pr\u00e9tendez pas qu 'une photographie de l'alimentation interne \u00e9tablit une cote de protection contre l'entr\u00e9e pour l'armoire finie. Gardez les ouvertures et l'acc\u00e8s conformes aux instructions d'installation; les proc\u00e9dures de nettoyage doivent respecter les exigences de service s\u00e9curitaire de l'\u00e9quipement.<\/p>\n<p>Rendre l'enregistrement de configuration utile apr\u00e8s la qualification initiale. Augmentation de la demande de contr\u00f4le, changement d'un disque voisin, r\u00e9acheminement des conduits, Le d\u00e9placement de l'alimentation ou la modification de la ventilation de l'armoire peut modifier les conditions thermiques \u00e9valu\u00e9es. Demandez \u00e0 l'examinateur responsable de d\u00e9cider si les preuves existantes demeurent applicables ou si une \u00e9valuation plus approfondie est n\u00e9cessaire. Un filtre modifi\u00e9 ou un intervalle d'entretien m\u00e9rite \u00e9galement un examen d'impact document\u00e9 lorsqu 'il affecte les conditions \u00e9valu\u00e9es. Configuration.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/04-thermal-evidence-configuration.png\" alt=\"Refroidissement de l&#039;alimentation \u00e9lectrique: Cabinet sans ventilateur Acceptation thermique titre =\" class=\"wp-image-18509\" power supply cooling: fanless cabinet thermal acceptance title =\"\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/04-thermal-evidence-configuration.png 1536w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/04-thermal-evidence-configuration-300x200.png 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/04-thermal-evidence-configuration-1024x683.png 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/04-thermal-evidence-configuration-768x512.png 768w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/04-thermal-evidence-configuration-18x12.png 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n<p>Pour l'approvisionnement, demandez un fichier tra\u00e7able contenant les documents du mod\u00e8le command\u00e9, le plan d'essai convenu, l'identit\u00e9 de l'\u00e9chantillon, l'enregistrement de configuration, les r\u00e9sultats r\u00e9els, les \u00e9carts et la d\u00e9cision de lib\u00e9ration.Gardez les informations manquantes visibles. Aucune pr\u00e9diction de dur\u00e9e de vie, approbation de l'armoire scell\u00e9e ou performance thermique garantie n'est \u00e9tablie par ce guide ou ses images g\u00e9n\u00e9r\u00e9es par l'IA.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Key_Takeaways\"><\/span>Points cl\u00e9s \u00e0 retenir<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul><li>D\u00e9finissez la configuration de l'unit\u00e9 et de l'armoire command\u00e9e avant de collecter les donn\u00e9es thermiques.<\/li><li>Distinguer l'air ambiant, l'air local et les points de cas; enregistrer l'incertitude de mesure.<\/li><li>Convenir des limites document\u00e9es et des crit\u00e8res de stabilisation avant d'examiner les r\u00e9sultats.<\/li><li>Ne d\u00e9duisez pas l'\u00e9tanch\u00e9it\u00e9 \u00e0 la poussi\u00e8re, la capacit\u00e9 de la bo\u00eete scell\u00e9e ou une courbe de d\u00e9gradation de l'absence de ventilateur.<\/li><li>Examiner la disposition, la charge et les modifications de service par rapport aux preuves conserv\u00e9es.<\/li><\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>DR-120 - 24 proporciona una identidad mec\u00e1nica espec\u00edfica de 24 V, 5 A para la discusi\u00f3n, mientras que las condiciones de enfriamiento ordenadas y el rendimiento real del gabinete siguen siendo controles de ingenier\u00eda. Pregunte a WEHO por la informaci\u00f3n controlada aplicable, conserve datos de muestra reales y resuelva preguntas abiertas antes de liberar el panel de control auxiliar.<\/p>\n<section class=\"weho-faq\" aria-labelledby=\"weho-faq-heading\">\n<h2 id=\"weho-faq-heading\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Questions fr\u00e9quemment pos\u00e9es<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<article class=\"weho-faq-item\">\n<h3><span class=\"ez-toc-section\" id=\"Is_this_another_fanless-versus-fan-cooled_comparison\"><\/span>Est-ce une autre comparaison fanless versus fan-cooled?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Il s'agit d'un plan d'acceptation thermique contr\u00f4l\u00e9 et d'une preuve de configuration pour une armoire de commande auxiliaire, plut\u00f4t que de classer les technologies de refroidissement.<\/p>\n<\/article>\n<article class=\"weho-faq-item\">\n<h3><span class=\"ez-toc-section\" id=\"Does_the_DR-120-24_image_prove_a_sealed-cabinet_rating\"><\/span>L'image DR-120 - 24 prouve-t-elle une classification d'armoire scell\u00e9e?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>La photo approuv\u00e9e montre une unit\u00e9 m\u00e9tallique ventil\u00e9e et aucun ventilateur visible. Les conditions de refroidissement et d'installation command\u00e9es n\u00e9cessitent toujours une documentation contr\u00f4l\u00e9e; l'image ne prouve ni les performances de la bo\u00eete scell\u00e9e ni l'\u00e9tanch\u00e9it\u00e9 \u00e0 la poussi\u00e8re.<\/p>\n<\/article>\n<article class=\"weho-faq-item\">\n<h3><span class=\"ez-toc-section\" id=\"Can_room_temperature_be_used_as_the_supplys_local_air_temperature\"><\/span>La temp\u00e9rature ambiante peut-elle \u00eatre utilis\u00e9e comme temp\u00e9rature de l'air local de l'alimentation?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>L'air ambiant, l'air local, l'air de l'enceinte et les points de cas externes sont des conditions diff\u00e9rentes et doivent \u00eatre identifi\u00e9s s\u00e9par\u00e9ment dans le plan d'essai.<\/p>\n<\/article>\n<article class=\"weho-faq-item\">\n<h3><span class=\"ez-toc-section\" id=\"How_long_should_every_thermal_trial_run\"><\/span>Combien de temps doit durer chaque essai thermique?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Convenir d'un crit\u00e8re de stabilisation et d'enregistrement adapt\u00e9 \u00e0 l'unit\u00e9, \u00e0 l'enceinte et au cycle de fonctionnement document\u00e9s avant de collecter les donn\u00e9es.<\/p>\n<\/article>\n<article class=\"weho-faq-item\">\n<h3><span class=\"ez-toc-section\" id=\"What_DR-120-24_derating_curve_is_supplied_here\"><\/span>Quelle courbe de d\u00e9ratation DR-120 - 24 est fournie ici?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Aucune. Aucune courbe courant\/temp\u00e9rature ou valeur de passage thermique admissible n'est d\u00e9duite. Obtenir les informations de r\u00e9vision ordonn\u00e9e applicables et laisser une limite non r\u00e9solue ouverte plut\u00f4t que d'en inventer une.<\/p>\n<\/article>\n<article class=\"weho-faq-item\">\n<h3><span class=\"ez-toc-section\" id=\"Do_the_moulding_and_baggage_images_show_measured_performance\"><\/span>Les images de moulage et de bagages montrent-elles des performances mesur\u00e9es?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Les deux sont des sc\u00e8nes de pr\u00e9paration m\u00e9canique isol\u00e9es avec des bornes d'alimentation vides et de l'\u00e9quipement sombre. Ils n'\u00e9tablissent pas les charges r\u00e9elles, les r\u00e9sultats thermiques, l'approbation de l'aviation ou la compatibilit\u00e9 de la machine.<\/p>\n<\/article>\n<article class=\"weho-faq-item\">\n<h3><span class=\"ez-toc-section\" id=\"When_does_a_cabinet_change_need_reassessment\"><\/span>Quand un changement de cabinet doit-il \u00eatre r\u00e9\u00e9valu\u00e9?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>L'examinateur responsable devrait \u00e9valuer les changements apport\u00e9s \u00e0 la charge, \u00e0 la disposition, aux sources de chaleur avoisinantes, \u00e0 la ventilation et aux dispositifs de service pertinents en fonction des donn\u00e9es de configuration conserv\u00e9es et d\u00e9cider si une \u00e9valuation plus approfondie est n\u00e9cessaire.<\/p>\n<\/article>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Planifier l'acceptation du refroidissement de l'alimentation \u00e9lectrique avec une configuration d'armoire contr\u00f4l\u00e9e, des points de temp\u00e9rature locaux, des limites document\u00e9es et un examen des modifications pour les contr\u00f4les OEM.<\/p>","protected":false},"author":1,"featured_media":18506,"parent":0,"menu_order":169,"comment_status":"closed","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[149],"class_list":["post-18510","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-blog","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news\/18510","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/comments?post=18510"}],"version-history":[{"count":1,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news\/18510\/revisions"}],"predecessor-version":[{"id":18523,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news\/18510\/revisions\/18523"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/media\/18506"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/media?parent=18510"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news_category?post=18510"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}