{"id":3087,"date":"2022-06-07T03:06:03","date_gmt":"2022-06-07T03:06:03","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=news&#038;p=3087"},"modified":"2026-09-07T19:11:19","modified_gmt":"2026-09-07T11:11:19","slug":"what-is-led-driver%ef%bc%9f","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/","title":{"rendered":"What Is LED Driver? LED Driver Power Supply Basics"},"content":{"rendered":"<p class=\"weho-last-updated\" style=\"text-align:center;color:#E60013\">Last Updated: 2026-09-03<\/p>\n<blockquote class=\"weho-quick-answer\">\n<p>What is led driver means a regulated power device that converts incoming AC or DC power into a controlled output for an LED load. It may regulate constant current or constant voltage, so buyers should confirm LED rating, wattage, dimming needs, wiring distance, heat, and installation environment.<\/p>\n<\/blockquote>\n<figure class=\"weho-blog-image weho-blog-hero\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/01-hero-22.png?quality=85&strip=all\" alt=\"WEHO XLG LED driver power supply mounted in a lighting validation rack\" title=\"WEHO XLG LED driver power supply mounted in a lighting validation rack\" width=\"1536\" height=\"1024\" class=\"alignnone size-full wp-image-17438\" srcset=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/01-hero-22.png?quality=85&strip=all 1536w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/01-hero-22-300x200.png?quality=85&strip=all 300w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/01-hero-22-1024x683.png?quality=85&strip=all 1024w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/01-hero-22-768x512.png?quality=85&strip=all 768w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/01-hero-22-18x12.png?quality=85&strip=all 18w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#what_is_led_driver_for_B2B_lighting_projects\" >what is led driver for B2B lighting projects<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#How_an_LED_driver_regulates_power\" >How an LED driver regulates power<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#Constant_current_and_constant_voltage_choices\" >Constant current and constant voltage choices<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#Use_approved_WEHO_LED_driver_references\" >Use approved WEHO LED driver references<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#Wiring_heat_and_commissioning_checks\" >Wiring, heat, and commissioning checks<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#Common_selection_mistakes\" >Common selection mistakes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#When_to_contact_WEHO\" >When to contact WEHO<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#FAQs\" >FAQs<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#What_is_a_led_driver_power_supply\" >What is a led driver power supply?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#Is_an_LED_driver_the_same_as_a_normal_power_supply\" >Is an LED driver the same as a normal power supply?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#How_do_I_choose_between_constant_current_and_constant_voltage\" >How do I choose between constant current and constant voltage?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#Why_does_heat_matter_when_choosing_an_LED_driver\" >Why does heat matter when choosing an LED driver?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#What_WEHO_facts_are_safe_to_cite_for_LED_driver_sourcing\" >What WEHO facts are safe to cite for LED driver sourcing?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#When_should_I_contact_WEHO_before_selecting_a_driver\" >When should I contact WEHO before selecting a driver?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#Key_Takeaways\" >Key Takeaways<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.wehopower.com\/fr\/news\/what-is-led-driver\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"what_is_led_driver_for_B2B_lighting_projects\"><\/span>what is led driver for B2B lighting projects<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>What is led driver<\/strong> is a practical sourcing question, not only a definition. An LED driver is selected around the LED load, not around a generic wattage number alone. The buyer needs to know whether the load expects regulated current, regulated voltage, dimming control, waterproof construction, cabinet mounting, or a special operating environment.<\/p>\n<p>For a B2B lighting project, the first step is to list the LED module type, rated input, total load, installation location, cable distance, ambient temperature, duty cycle, and service requirements. These inputs decide whether the correct product is a constant-current driver, a constant-voltage driver, or another power architecture.<\/p>\n<p>Many field problems start when a normal DC supply is treated as interchangeable with an LED driver. The label may look similar, but the output behavior, protection response, load range, and installation limits can be different. That is why <strong>what is led driver<\/strong> should be answered from the LED module requirement first.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_an_LED_driver_regulates_power\"><\/span>How an LED driver regulates power<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure class=\"weho-blog-image\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/02-technical-diagram-23.png?quality=85&strip=all\" alt=\"LED driver power supply regulation diagram for constant current and constant voltage loads\" title=\"LED driver power supply regulation diagram for constant current and constant voltage loads\" width=\"1536\" height=\"1024\" class=\"alignnone size-full wp-image-17439\" loading=\"lazy\" srcset=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/02-technical-diagram-23.png?quality=85&strip=all 1536w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/02-technical-diagram-23-300x200.png?quality=85&strip=all 300w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/02-technical-diagram-23-1024x683.png?quality=85&strip=all 1024w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/02-technical-diagram-23-768x512.png?quality=85&strip=all 768w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/02-technical-diagram-23-18x12.png?quality=85&strip=all 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n<p>An LED load needs controlled electrical conditions. In a constant-current design, the driver regulates current and allows voltage to move within a documented output-voltage window. In a constant-voltage design, the driver holds a fixed DC voltage and the LED load or strip design controls current.<\/p>\n<p>This distinction matters because LEDs are sensitive to overcurrent and heat. Too much current can shorten service life or damage modules. Too little available voltage, excessive cable drop, or poor matching can cause unstable brightness, flicker, nuisance protection trips, or incomplete startup.<\/p>\n<p>A <strong>led driver power supply<\/strong> should therefore be checked against the exact LED module specification. Confirm the drive current, voltage range, total wattage, minimum and maximum load, dimming method, protection behavior, and whether the driver can operate in the project&#8217;s enclosure and temperature range.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Constant_current_and_constant_voltage_choices\"><\/span>Constant current and constant voltage choices<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use a constant-current driver when the LED module datasheet specifies a required current, such as a defined milliampere rating, plus a forward-voltage range. This layout is common where LED strings are designed to be current controlled.<\/p>\n<p>Use a constant-voltage driver when the LED product is designed for a fixed DC bus, such as 12 V, 24 V, 36 V, or 48 V strip and signage systems. In that case, the connected LED assembly must already include suitable current control or resistance, and the supply must have enough current capacity for the total connected load.<\/p>\n<p>Do not mix these output types without checking the load design. A constant-current output connected to the wrong kind of load can behave unpredictably. A fixed-voltage output connected to bare LED strings can create excessive current unless the LED assembly is designed for that voltage.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Use_approved_WEHO_LED_driver_references\"><\/span>Use approved WEHO LED driver references<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure class=\"weho-blog-image\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/03-product-22.png?quality=85&strip=all\" alt=\"WEHO XLG LED driver power supply in a quality inspection cradle\" title=\"WEHO XLG LED driver power supply in a quality inspection cradle\" width=\"1536\" height=\"1024\" class=\"alignnone size-full wp-image-17440\" loading=\"lazy\" srcset=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/03-product-22.png?quality=85&strip=all 1536w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/03-product-22-300x200.png?quality=85&strip=all 300w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/03-product-22-1024x683.png?quality=85&strip=all 1024w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/03-product-22-768x512.png?quality=85&strip=all 768w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/03-product-22-18x12.png?quality=85&strip=all 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n<p>Start selection from the approved <a href=\"https:\/\/www.wehopower.com\/product_category\/led-driver\/\">WEHO LED driver category<\/a> and compare the product family against the load requirement. The category includes LED power options for different output types, wattages, installation environments, and protection requirements.<\/p>\n<p>For a product-specific reference, review this approved <a href=\"https:\/\/www.wehopower.com\/product\/150w-ip67-waterproof-constant-current-power-supply-12v-24v-36v-48v-led-driver\/\">WEHO 150W IP67 LED driver page<\/a>. Treat the page as a starting point for product matching, then confirm the exact variant, datasheet, wiring diagram, derating curve, and installation instructions before purchase.<\/p>\n<p>If the project is mainly outdoor signage or display lighting, this approved WEHO article on <a href=\"https:\/\/www.wehopower.com\/news\/enclosed-switching-power-supply-for-outdoor-signage-and-displays\/\">enclosed switching power supply for outdoor signage and displays<\/a> can help compare environment, enclosure, and load-planning concerns.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Wiring_heat_and_commissioning_checks\"><\/span>Wiring, heat, and commissioning checks<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure class=\"weho-blog-image\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/04-installation-24.png?quality=85&strip=all\" alt=\"Technician mounting a WEHO LED driver power supply in a protected enclosure\" title=\"Technician mounting a WEHO LED driver power supply in a protected enclosure\" width=\"1536\" height=\"1024\" class=\"alignnone size-full wp-image-17441\" loading=\"lazy\" srcset=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/04-installation-24.png?quality=85&strip=all 1536w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/04-installation-24-300x200.png?quality=85&strip=all 300w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/04-installation-24-1024x683.png?quality=85&strip=all 1024w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/04-installation-24-768x512.png?quality=85&strip=all 768w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/04-installation-24-18x12.png?quality=85&strip=all 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n<p>Installation should be performed by qualified personnel with incoming power isolated and verified safe. Separate AC input conductors from low-voltage output wiring, protect branches according to the system design, observe polarity, and use terminals, connectors, and cable glands within their documented ratings.<\/p>\n<p>Heat is a major selection gate for any <strong>led driver power supply<\/strong>. Check ambient temperature, enclosure temperature, mounting surface, airflow, spacing around the product, and nearby heat sources. A driver that works on a bench can be marginal in a sealed sign cabinet or outdoor fixture if derating is ignored.<\/p>\n<p>Commission the system under real load. Record input voltage, output voltage, output current, load state, ambient temperature, abnormal sound, abnormal heat, protection behavior, and measured voltage at the far end of long cable runs. These measurements give maintenance teams a baseline for later troubleshooting.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Common_selection_mistakes\"><\/span>Common selection mistakes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>Choosing by wattage alone without checking current mode, voltage range, and derating.<\/li>\n<li>Using a constant-current driver for a load that needs fixed voltage.<\/li>\n<li>Using a fixed-voltage supply for LED modules that require current regulation.<\/li>\n<li>Ignoring cable voltage drop, enclosure heat, dimming compatibility, or minimum-load limits.<\/li>\n<li>Assuming an IP rating, certification, or wiring method that is not confirmed by product documentation.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"When_to_contact_WEHO\"><\/span>When to contact WEHO<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure class=\"weho-blog-image\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/05-application-22.png?quality=85&strip=all\" alt=\"WEHO LED driver power supply serving an outdoor commercial lighting scene\" title=\"WEHO LED driver power supply serving an outdoor commercial lighting scene\" width=\"1536\" height=\"1024\" class=\"alignnone size-full wp-image-17442\" loading=\"lazy\" srcset=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/05-application-22.png?quality=85&strip=all 1536w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/05-application-22-300x200.png?quality=85&strip=all 300w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/05-application-22-1024x683.png?quality=85&strip=all 1024w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/05-application-22-768x512.png?quality=85&strip=all 768w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2026\/09\/05-application-22-18x12.png?quality=85&strip=all 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n<p>Contact WEHO when the LED load is not fully specified, when the installation is outdoors, when cables are long, when dimming controls are involved, or when the enclosure temperature may be high. Provide the input voltage, LED module rating, total wattage, wiring distance, mounting environment, control requirements, and expected duty cycle.<\/p>\n<p>WEHO was founded in 2007 and offers 1000+ models. Confirmed WEHO quality facts include 100% high-temperature full-load testing, 99.7% yield, and ISO9001, CE, RoHS, FCC, and CCC. Do not treat these facts as a substitute for checking the exact model&#8217;s technical file.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"FAQs\"><\/span>FAQs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"weho-visible-faq\">\n<h3><span class=\"ez-toc-section\" id=\"What_is_a_led_driver_power_supply\"><\/span>What is a led driver power supply?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A led driver power supply is a regulated power device made for LED loads. It controls either current or voltage so the connected LED module operates inside its rated electrical range.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Is_an_LED_driver_the_same_as_a_normal_power_supply\"><\/span>Is an LED driver the same as a normal power supply?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Not always. Some LED drivers behave like constant-voltage supplies, while constant-current drivers regulate output current and allow voltage to vary within a documented range.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"How_do_I_choose_between_constant_current_and_constant_voltage\"><\/span>How do I choose between constant current and constant voltage?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Use constant current when the LED module specifies a drive current and forward-voltage range. Use constant voltage when the load is designed for a fixed DC voltage, such as many strip-lighting systems.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Why_does_heat_matter_when_choosing_an_LED_driver\"><\/span>Why does heat matter when choosing an LED driver?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Heat affects lifetime and usable output margin. Check ambient temperature, enclosure temperature, airflow, mounting surface, derating data, and whether the driver is installed near other heat sources.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_WEHO_facts_are_safe_to_cite_for_LED_driver_sourcing\"><\/span>What WEHO facts are safe to cite for LED driver sourcing?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>WEHO was founded in 2007, offers 1000+ models, performs 100% high-temperature full-load testing, reports 99.7% yield, and lists ISO9001, CE, RoHS, FCC, and CCC.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"When_should_I_contact_WEHO_before_selecting_a_driver\"><\/span>When should I contact WEHO before selecting a driver?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Contact WEHO when the project has outdoor exposure, long cable runs, dimming controls, high operating temperature, uncertain load ratings, or a need to compare constant-current and constant-voltage options.<\/p>\n<\/div>\n<h2><span class=\"ez-toc-section\" id=\"Key_Takeaways\"><\/span>Key Takeaways<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>A <strong>led driver power supply<\/strong> must match the LED load&#8217;s current or voltage requirement.<\/li>\n<li>Constant-current and constant-voltage drivers are not interchangeable without load verification.<\/li>\n<li>Check wattage, load range, cable drop, dimming, protection, heat, and installation environment together.<\/li>\n<li>Use approved WEHO category and product pages, then verify the exact model documentation.<\/li>\n<li>Record commissioning measurements so troubleshooting has a reliable baseline.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A reliable answer to <strong>what is led driver<\/strong> starts with the LED module specification and ends with measured commissioning data. Match output mode first, then confirm wattage, derating, wiring distance, thermal conditions, controls, protection, and documentation for the exact model.<\/p>\n<p>Review the <a href=\"https:\/\/www.wehopower.com\/product_category\/led-driver\/\">WEHO LED driver category<\/a> or <a href=\"https:\/\/www.wehopower.com\/contact\/\">contact WEHO<\/a> with your load schedule and installation details. You can also email sarayu@chnwh.com for product matching support.<\/p>\n<div class=\"weho-article-cta\">\n<p>Review the <a href=\"https:\/\/www.wehopower.com\/product_category\/led-driver\/\">relevant WEHO product category<\/a>, email <a href=\"mailto:sarayu@chnwh.com\">sarayu@chnwh.com<\/a>, or <a href=\"https:\/\/www.wehopower.com\/contact\/\">contact WEHO<\/a> with the input voltage, output load, ambient temperature, and installation details.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\" class=\"weho-faq-schema\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is a led driver power supply?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A led driver power supply is a regulated power device made for LED loads. It controls either current or voltage so the connected LED module operates inside its rated electrical range.\"}},{\"@type\":\"Question\",\"name\":\"Is an LED driver the same as a normal power supply?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Not always. Some LED drivers behave like constant-voltage supplies, while constant-current drivers regulate output current and allow voltage to vary within a documented range.\"}},{\"@type\":\"Question\",\"name\":\"How do I choose between constant current and constant voltage?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Use constant current when the LED module specifies a drive current and forward-voltage range. Use constant voltage when the load is designed for a fixed DC voltage, such as many strip-lighting systems.\"}},{\"@type\":\"Question\",\"name\":\"Why does heat matter when choosing an LED driver?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Heat affects lifetime and usable output margin. Check ambient temperature, enclosure temperature, airflow, mounting surface, derating data, and whether the driver is installed near other heat sources.\"}},{\"@type\":\"Question\",\"name\":\"What WEHO facts are safe to cite for LED driver sourcing?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"WEHO was founded in 2007, offers 1000+ models, performs 100% high-temperature full-load testing, reports 99.7% yield, and lists ISO9001, CE, RoHS, FCC, and CCC.\"}},{\"@type\":\"Question\",\"name\":\"When should I contact WEHO before selecting a driver?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Contact WEHO when the project has outdoor exposure, long cable runs, dimming controls, high operating temperature, uncertain load ratings, or a need to compare constant-current and constant-voltage options.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>what is led driver explains how LED driver power supply selection works for constant current, constant voltage, wiring, heat, and WEHO LED driver checks.<\/p>","protected":false},"author":1,"featured_media":17438,"parent":0,"menu_order":429,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[149,148],"class_list":["post-3087","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-blog","news_category-industry-news","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news\/3087","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/comments?post=3087"}],"version-history":[{"count":4,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news\/3087\/revisions"}],"predecessor-version":[{"id":17443,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news\/3087\/revisions\/17443"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/media\/17438"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/media?parent=3087"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/news_category?post=3087"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}