{"id":14205,"date":"2026-04-21T10:51:15","date_gmt":"2026-04-21T02:51:15","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=product&#038;p=11068"},"modified":"2026-04-28T14:50:40","modified_gmt":"2026-04-28T06:50:40","slug":"weho-sp-9000-series-9000w-intelligent-programmable-dc-power-module-with-advanced-modbus-telemetry","status":"publish","type":"product","link":"https:\/\/www.wehopower.com\/fr\/product\/weho-sp-9000-series-9000w-intelligent-programmable-dc-power-module-with-advanced-modbus-telemetry\/","title":{"rendered":"WEHO SP-9000 Series: 9000W Intelligent Programmable DC Power Module with Advanced Modbus Telemetry"},"content":{"rendered":"<p><strong>R\u00e9sum\u00e9<\/strong><\/p>\n<p>Single output: Power 9000W<\/p>\n<p>Input voltage: 95-190VAC(output current 50%)195-265VAC(output current 100%)<\/p>\n<p>&nbsp;<\/p>\n<p><strong><b>Differentiated Advantages<\/b><\/strong><\/p>\n<p>The SP-9000 separates itself from conventional high-wattage power supplies through its highly customizable fault-logic and deep integration capabilities:<\/p>\n<p><strong><b>Programmable Surge Tolerance (5-Second Delay):<\/b><\/strong>\u00a0Unlike standard industrial units that instantly shut down during current spikes, the SP-9000 features a user-programmable over-current logic. Operators can set a specific over-current threshold with a 5-second delay. This uniquely allows the system to absorb massive startup surges from heavy inductive motors or capacitive loads without triggering a disruptive system-wide reset.<\/p>\n<p><strong><b>Absolute Zero-to-Peak Tuning:<\/b><\/strong>\u00a0It breaks the mold of static converters by offering extreme linear adjustability. Both output voltage and constant current can be meticulously dialed in from absolute zero up to their maximum over-ratings (e.g., 0-242V continuous tuning on the 220V model). This provides the surgical precision required for highly sensitive electrochemical processing, EV battery formation, and rigorous R&amp;D stress testing.<\/p>\n<p><strong><b>Customizable Industrial Telemetry:<\/b><\/strong>\u00a0Designed for seamless SCADA and PLC ecosystem integration, it pairs its RS485 Modbus protocol with customizable hardware feedback. With bespoke options for dry-contact &#8220;Power Good&#8221; alarm signals (\u226436V, 0.1A) and high-level remote switching, it allows facility engineers to monitor power health in real-time, drastically reducing the need for expensive third-party relays and secondary wiring in OEM control cabinets.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Sp\u00e9cification g\u00e9n\u00e9rale<\/strong><\/p>\n<table style=\"width: 100%;\" width=\"100%\">\n<tbody>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Mod\u00e8le<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">SP-9000-24<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">SP-9000-30<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">SP-9000-36<\/td>\n<td style=\"text-align: center; width: 11.8927%;\" width=\"119\">SP-9000-48<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">SP-9000-60<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">SP-9000-110<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">SP-9000-220<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Tension continue<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">24V<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">30V<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">36V<\/td>\n<td style=\"text-align: center; width: 11.8927%;\" width=\"119\">48V<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">60V<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">110V<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">220V<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Courant nominal<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">337.5A<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">270A<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">225A<\/td>\n<td style=\"text-align: center; width: 11.8927%;\" width=\"119\">168.8A<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">135A<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">73.6A<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">36.8A<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Plage actuelle<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">0-337.5A<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">0-270A<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">0-225A<\/td>\n<td style=\"text-align: center; width: 11.8927%;\" width=\"119\">0-168.8A<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">0-135A<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">0-73.6A<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">0-36.8A<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Puissance nominale<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">9000W<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Ondulation<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">500mV<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">500mV<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">500mV<\/td>\n<td style=\"text-align: center; width: 11.8927%;\" width=\"119\">600mV<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">600mV<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">1000mV<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">1500mV<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Plage optimale \u00e0 courant constant<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">12-24V<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">15-30V<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">18-36V<\/td>\n<td style=\"text-align: center; width: 11.8927%;\" width=\"119\">24-48V<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">30-60V<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">55-110V<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">110-220V<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Pr\u00e9cision de la tension nominale<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">\u00b11,0%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">R\u00e9gulation de ligne<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">\u00b11,0%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">R\u00e9gulation de charge<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">\u00b11,0%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Startup&amp;Rise Time<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">1500mS,700mS\/230VAC (Fully loaded)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Plage de tension<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">95-190VAC(Output Current 50%),195-265VAC(Output Curent 100%)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Gamme de fr\u00e9quence<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">45Hz-65Hz<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Facteur de puissance<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">PF\u22650.99\/230VAC (Fully loaded)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Efficacit\u00e9 (MAX)<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">0.9<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">0.9<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">0.915<\/td>\n<td style=\"text-align: center; width: 11.8927%;\" width=\"119\">0.92<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">0.92<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">0.925<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">0.93<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Courant alternatif<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">&lt;56A<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Courant de fuite<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">&lt;3,0 mA\/240 VCA<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Court-circuit<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">When the constant current is entered and the voltage is lower than 10%of the rated voltage,the output is shut down and locked after 1 second,and recover after restarting.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Over current<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">The user can set the over-curent value to delay the oufout for 5 seconds and then shut down the output,and then resume after restarting.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Surpression<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">Users can set the overvoltage value to shut down the output voltage,and restore after restart.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Surchauffe<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">Shut down the output,automatically recover or restart after the temperature drops.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">R\u00e9glage de la tension de sortie<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">0-26,4V<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">0-33V<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">0-39,6V<\/td>\n<td style=\"text-align: center; width: 11.8927%;\" width=\"119\">0-52,8V<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">0-66V<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">0-121V<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">0-242V<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">R\u00e9glage du courant constant de sortie<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">0-337.5A<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">0-270A<\/td>\n<td style=\"text-align: center; width: 11.6751%;\" width=\"117\">0-225A<\/td>\n<td style=\"text-align: center; width: 11.8927%;\" width=\"119\">0-168.8A<\/td>\n<td style=\"text-align: center; width: 11.9652%;\" width=\"120\">0-135A<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">0-73.6A<\/td>\n<td style=\"text-align: center; width: 12.5453%;\" width=\"127\">0-36.8A<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">485 Communications<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">Protocole de communication MODBUS<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Isolated auxiliary<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">12V0.5A (Need customization)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Commutateur \u00e0 distance de sortie<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">Default power on,high level power off (5V-12V)(Need customization)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Sortie de signal d'alarme<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">Power Good Signal(Dry Contact\u226436V,0.1A)\u00a0 (Need customization)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Temp\u00e9rature de fonctionnement<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">-20-+60\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Humidit\u00e9 de fonctionnement<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">-20-90%RH No condensation<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Temp\u00e9rature et humidit\u00e9 de stockage<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">-40-+85\u2103,10-95%RHNo condensation<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">R\u00e9sistance aux vibrations<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">110-500Hz,2G10 Min\/cycle, X,Y,Z60 Min<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Insulaion resistance<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">\u8f93\u5165\u8f93\u51fa\uff1a100Mhms\/500VDC\/25\u00b0C\/70%RH<br \/>\nInput to Output:100Mhms\/500VDC\/25\u00b0C\/70%RH<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">R\u00e9sistance \u00e0 la pression<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">I\/P-O\/P:2KVAC IP-FG:2KVAC O\/P-FG:0.5KVAC<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Taille<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">432\u00d7179\u00d7242mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.3582%;\" width=\"110\">Poids net<\/td>\n<td style=\"text-align: center; width: 84.264%;\" colspan=\"7\" width=\"850\">12.5 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Dimension globale (mm)<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-10702\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2024\/11\/DIMENSION-SP9000.png?quality=85&strip=all\" alt=\"WEHO SP-9000 Series: 9000W Intelligent Programmable DC Power Module with Advanced Modbus Telemetry  title=\" width=\"741\" height=\"250\" weho sp-9000 series: 9000w intelligent programmable dc power module with advanced modbus telemetry title=\"\"><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Summary Single output: Power 9000W Input voltage: 95-190VAC(output current 50%)195-265VAC(output current 100%) &nbsp; Differentiated Advantages The SP-9000 separates itself from conventional high-wattage power supplies through its highly customizable fault-logic and deep integration capabilities: Programmable Surge Tolerance (5-Second Delay):\u00a0Unlike standard industrial units that instantly shut down during current spikes, the SP-9000 features a user-programmable over-current logic.&hellip; <a class=\"more-link\" href=\"https:\/\/www.wehopower.com\/fr\/product\/weho-sp-9000-series-9000w-intelligent-programmable-dc-power-module-with-advanced-modbus-telemetry\/\">Continue reading <span class=\"screen-reader-text\">WEHO SP-9000 Series: 9000W Intelligent Programmable DC Power Module with Advanced Modbus Telemetry<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":13738,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[232],"product_categories_new":[],"class_list":["post-14205","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-se-sed-sp-series-adjustable-ac-to-dc-power-supply","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/product\/14205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/comments?post=14205"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/product\/14205\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/media\/13738"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/media?parent=14205"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/product_category?post=14205"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/product_categories_new?post=14205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}