{"id":5414,"date":"2023-08-24T06:30:57","date_gmt":"2023-08-24T06:30:57","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=product&#038;p=5414"},"modified":"2025-07-21T10:55:26","modified_gmt":"2025-07-21T02:55:26","slug":"ip67-waterproof-led-driver-ac-95-264v-dc-12v-24v-36v-48v-60w-single-output-constant-current-switching-power-supply","status":"publish","type":"product","link":"https:\/\/www.wehopower.com\/fr\/product\/ip67-waterproof-led-driver-ac-95-264v-dc-12v-24v-36v-48v-60w-single-output-constant-current-switching-power-supply\/","title":{"rendered":"Pilote LED \u00e9tanche IP67, AC 95-264V DC 12V 24V 36V 48V 60W, sortie unique, courant Constant, alimentation \u00e0 d\u00e9coupage"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_tta-container\" data-vc-action=\"collapse\"><div class=\"vc_general vc_tta vc_tta-accordion vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-o-shape-group vc_tta-controls-align-default\"><div class=\"vc_tta-panels-container\"><div class=\"vc_tta-panels\"><div class=\"vc_tta-panel vc_active\" id=\"1636701172155-32719f5d-02c1\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1636701172155-32719f5d-02c1\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Sp\u00e9cifications et mod\u00e8le<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"250\">Mod\u00e8le<\/td>\n<td width=\"173\">XLG-60-12<\/td>\n<td width=\"173\">XLG-60-24<\/td>\n<td width=\"173\">XLG-60-36<\/td>\n<td width=\"173\">XLG-60-48<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Tension de sortie CC<\/td>\n<td>12V<\/td>\n<td>24V<\/td>\n<td>36V<\/td>\n<td>48V<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Courant de sortie nominal<\/td>\n<td>5A<\/td>\n<td>2,5A<\/td>\n<td>1.7A<\/td>\n<td>1.25A<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Plage de courant constant<\/td>\n<td>6~12V<\/td>\n<td>12 ~ 24 V<\/td>\n<td>18 ~ 36 V<\/td>\n<td>24 ~ 48 V<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Puissance de sortie<\/td>\n<td>60W<\/td>\n<td>60W<\/td>\n<td>61.2W<\/td>\n<td>60W<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Vague et bruit<\/td>\n<td>150 mVcr\u00eate \u00e0 cr\u00eate<\/td>\n<td>150 mVcr\u00eate \u00e0 cr\u00eate<\/td>\n<td>180 mVcr\u00eate \u00e0 cr\u00eate<\/td>\n<td>200 mVcr\u00eate \u00e0 cr\u00eate<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Pr\u00e9cision de la tension<\/td>\n<td>\u00b12%<\/td>\n<td>\u00b1 1,5%<\/td>\n<td>\u00b1 1,5%<\/td>\n<td>\u00b1 1,5%<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">R\u00e9gulation de ligne<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b10,5%<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">R\u00e9gulation de charge<\/td>\n<td>\u00b12%<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b10,5%<\/td>\n<td>\u00b10,5%<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Commencer, monter, tenir le temps<\/td>\n<td colspan=\"4\">500\u00a0ms, 80\u00a0ms, 16\u00a0ms\/230 V\u00a0CA (\u00e0 pleine charge)<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Plage de tension d'entr\u00e9e<\/td>\n<td colspan=\"4\">95 ~ 264 VCA, 135 ~ 373 VCC<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Gamme de fr\u00e9quence<\/td>\n<td colspan=\"4\">47 ~ 63 Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Courant d'entr\u00e9e CA<\/td>\n<td colspan=\"4\">1.4A\/115VAC\u00a0\u00a0\u00a0 0.8A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Efficacit\u00e9<\/td>\n<td>87.5%<\/td>\n<td>88.5%<\/td>\n<td>89.5%<\/td>\n<td>90.0%<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Courant d'impulsion<\/td>\n<td colspan=\"4\">Cold start current\u00a0\u00a0 50A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Courant de fuite<\/td>\n<td colspan=\"4\">&lt;1mA\/240VAC<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Protection contre les surintensit\u00e9s<\/td>\n<td colspan=\"4\" width=\"693\">95% ~ 108% du courant de sortie nominal d\u00e9marre la limite de surintensit\u00e9,<br \/>\nr\u00e9cup\u00e9rer automatiquement apr\u00e8s la suppression des conditions anormales<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Protection de court-circuit<\/td>\n<td colspan=\"4\">Mode Hiccup\u00a0: r\u00e9cup\u00e8re automatiquement la sortie normale une fois les conditions anormales supprim\u00e9es<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Temp\u00e9rature de travail<\/td>\n<td colspan=\"4\">-20 \u2103 ~ +60 \u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Humidit\u00e9 de travail<\/td>\n<td colspan=\"4\">20% ~ 90% RH, sans condensation<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Temp\u00e9rature et humidit\u00e9 de stockage<\/td>\n<td colspan=\"4\">-40 \u2103 ~ +85 \u2103 ; 10% ~ 95% RH, sans condensation<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">R\u00e9sistance sismique<\/td>\n<td colspan=\"4\">10 ~ 500 Hz, 3G 10 min\/1 cycle, axes X, Y, Z, dur\u00e9e 60 minutes<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">R\u00e9sistance \u00e0 la pression<\/td>\n<td colspan=\"4\">I\/P~O\/P\u00a0: 1,5\u00a0KVAC\u00a0\u00a0\u00a0 I\/P~FG\u00a0: 1,5\u00a0KVAC\u00a0\u00a0\u00a0 O\/P~FG\u00a0:\u00a00,5KVAC<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">R\u00e9sistance d'isolement<\/td>\n<td colspan=\"4\">I\/P ~ O\/P, I\/P ~ FG, O\/P ~ FG\u00a0: 100 M Ohms\/500 V CC\/25 \u2103\/70%RH<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Norme de s\u00e9curit\u00e9<\/td>\n<td colspan=\"4\">Conformit\u00e9 aux normes UL 60950-1, TUV EN 60950-1, GB19510.1, KC 61347-1, IP67<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">\u00c9mission de compatibilit\u00e9 \u00e9lectromagn\u00e9tique<\/td>\n<td colspan=\"4\">Conformit\u00e9 \u00e0 EN55022 classe A, GB17625.1, EN55015<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Immunit\u00e9 de compatibilit\u00e9 \u00e9lectromagn\u00e9tique<\/td>\n<td colspan=\"4\">Conformit\u00e9 \u00e0 EN55024<\/td>\n<\/tr>\n<tr>\n<td width=\"250\">Dimension<\/td>\n<td colspan=\"4\">170*49*34mm (L*L*H)<\/td>\n<\/tr>\n<tr>\n<td>Emballage<\/td>\n<td colspan=\"4\">0,45 kg\/30 pi\u00e8ces\/14,5 kg\/0,025 m\u00e8tres cubes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"1679370308601-4517364e-63fa\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1679370308601-4517364e-63fa\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">D\u00e9tails<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"171\" src=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2023\/08\/Dimensions-3.jpg?quality=85&strip=all\" class=\"vc_single_image-img attachment-full\" alt=\"Dimensions 3\" title=\"Dimensions 3\" srcset=\"https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2023\/08\/Dimensions-3.jpg?quality=85&strip=all 800w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2023\/08\/Dimensions-3-300x64.jpg?quality=85&strip=all 300w, https:\/\/i1.wp.com\/www.wehopower.com\/wp-content\/uploads\/2023\/08\/Dimensions-3-768x164.jpg?quality=85&strip=all 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" style=\"width:100%;height:21.38%;max-width:800px;\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>XLG-60W adopts the international common AC input voltage range\uff0cand the whole series provides 12V\uff0c24V\uff0c36V and 48V outputs.<\/p>","protected":false},"author":1,"featured_media":5423,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[85,42],"product_categories_new":[132],"class_list":["post-5414","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-xlg-waterproof-series","product_category-led-driver","product_categories_new-waterproof-xlg-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/product\/5414","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/comments?post=5414"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/product\/5414\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/media\/5423"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/media?parent=5414"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/product_category?post=5414"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/www.wehopower.com\/fr\/wp-json\/wp\/v2\/product_categories_new?post=5414"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}