{"id":22099,"date":"2026-11-15T18:08:57","date_gmt":"2026-11-15T10:08:57","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/tx4-s-sensor-response-timing\/"},"modified":"2026-11-15T18:08:57","modified_gmt":"2026-11-15T10:08:57","slug":"tx4-s-sensor-response-timing","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/","title":{"rendered":"TX4-S Sensor Response: Separate Probe Lag from Controller Timing"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0935\u093f\u0937\u092f\u0938\u0942\u091a\u0940<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u091f\u0949\u0917\u0932<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#Key_Engineering_Takeaways\" >Key Engineering Takeaways<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#Why_Can_a_Temperature_Reading_Arrive_Late\" >Why Can a Temperature Reading Arrive Late?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#What_Does_a_Probe_Response-Time_Number_Mean\" >What Does a Probe Response-Time Number Mean?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#Standard_Engineering_Response-Criterion_Example\" >Standard Engineering Response-Criterion Example<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#Which_Delays_Belong_to_the_Measurement_Chain\" >Which Delays Belong to the Measurement Chain?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#How_Should_an_OEM_Compare_Two_Probe_Assemblies\" >How Should an OEM Compare Two Probe Assemblies?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#What_Decision_Should_the_Comparison_Support\" >What Decision Should the Comparison Support?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#Engineering_FAQ\" >Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#Is_a_display_refresh_time_the_same_as_probe_response_time\" >Is a display refresh time the same as probe response time?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#Is_632_calculated_from_zero_degrees\" >Is 63.2% calculated from zero degrees?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#Can_an_air-test_response_be_compared_with_a_water-test_response\" >Can an air-test response be compared with a water-test response?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#Will_a_faster_probe_always_improve_a_TX4-S_loop\" >Will a faster probe always improve a TX4-S loop?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.wehopower.com\/hi\/news\/tx4-s-sensor-response-timing\/#Does_this_article_specify_a_TX4-S_response-time_limit\" >Does this article specify a TX4-S response-time limit?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"key-engineering-takeaways\"><span class=\"ez-toc-section\" id=\"Key_Engineering_Takeaways\"><\/span>Key Engineering Takeaways<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>A faster display update cannot remove the thermal lag of a probe or its mounting.<\/li>\n<li>Compare response-time claims only when the percentage criterion and test conditions match.<\/li>\n<li>A hypothetical 20-to-100 \u00b0C step reaches its 63.2% point at about 70.6 \u00b0C.<\/li>\n<li>Record the TX4-S configuration and the complete probe assembly before deciding what to change.<\/li>\n<\/ul>\n<figure data-role=\"hero\"><a href=\"https:\/\/www.wehopower.com\/hi\/product\/tx4-series-tx4-s-economic-dual-display-pid-temperature-controller\/\" aria-label=\"View TX4-S product details\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/tx4-s-probe-response-application.avif\" width=\"1200\" height=\"675\" alt=\"TX4-S Sensor Response: Separate Probe Lag from Controller Timing  title=\" data-image-role=\"hero\" loading=\"eager\" tx4-s sensor response: separate probe lag from controller timing title =\"\"><\/a><figcaption>Application illustration; not a customer installation photo. Scene created with AI assistance. The inactive TX4-S display and generic protected probe connection do not depict a response test or establish rear terminal wiring. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-tx4-s-control-direction-application-1200x675-master.png\">View source image<\/a><\/figcaption><\/figure>\n<nav aria-label=\"Article contents\">\n<details>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#key-engineering-takeaways\">Key Engineering Takeaways<\/a><\/li>\n<li><a href=\"#why-can-a-temperature-reading-arrive-late\">Why Can a Temperature Reading Arrive Late?<\/a><\/li>\n<li><a href=\"#what-does-a-probe-response-time-number-mean\">What Does a Probe Response-Time Number Mean?<\/a><\/li>\n<li><a href=\"#standard-engineering-response-criterion-example\">Standard Engineering Response-Criterion Example<\/a><\/li>\n<li><a href=\"#which-delays-belong-to-the-measurement-chain\">Which Delays Belong to the Measurement Chain?<\/a><\/li>\n<li><a href=\"#how-should-an-oem-compare-two-probe-assemblies\">How Should an OEM Compare Two Probe Assemblies?<\/a><\/li>\n<li><a href=\"#what-decision-should-the-comparison-support\">What Decision Should the Comparison Support?<\/a><\/li>\n<li><a href=\"#engineering-faq\">Engineering FAQ<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<h2 id=\"why-can-a-temperature-reading-arrive-late\"><span class=\"ez-toc-section\" id=\"Why_Can_a_Temperature_Reading_Arrive_Late\"><\/span>Why Can a Temperature Reading Arrive Late?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A machine can develop a real temperature change before its temperature probe reports the full change. Heat must pass through the installed probe assembly, and the measuring junction has thermal mass. The controller then processes the input and presents a value. These stages should be investigated separately before a team orders a different controller to solve an unidentified delay.<\/p>\n<p>The <a href=\"https:\/\/www.wehopower.com\/hi\/product\/tx4-series-tx4-s-economic-dual-display-pid-temperature-controller\/\">TX4-S temperature controller<\/a> is the product reference here. The engineering task is to distinguish probe response from controller and observation timing. This article does not assign an undocumented response time to a TX4-S unit or to the generic probe shown in the application illustration.<\/p>\n<h2 id=\"what-does-a-probe-response-time-number-mean\"><span class=\"ez-toc-section\" id=\"What_Does_a_Probe_Response-Time_Number_Mean\"><\/span>What Does a Probe Response-Time Number Mean?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A response time needs a defined temperature change, endpoint criterion and test environment. <a href=\"https:\/\/www.dwyeromega.com\/en-gb\/resources\/thermocouples-response-time\" target=\"_blank\" rel=\"noopener\">OMEGA&#39;s thermocouple response explanation<\/a> describes the time constant using 63.2% of an applied step change. A number stated at 90% or 95% is a different criterion and cannot be compared directly without an appropriate model and conditions.<\/p>\n<p>The environment also changes the result. Probe construction, sheath, surrounding medium, movement of that medium and installation contact affect heat transfer. A value measured in moving water is not automatically the response of the same assembly inside a metal block or still air. Keep the conditions attached to the number when preparing a purchase comparison.<\/p>\n<p>A sheath and a thermowell are separate parts of the assembly. If the quoted result describes a bare probe, adding a protective well or a poorly contacting mounting arrangement can change the response. Evaluate the installed assembly that the process will actually use rather than assuming the catalog probe value applies unchanged.<\/p>\n<figure data-role=\"product\"><a href=\"https:\/\/www.wehopower.com\/hi\/product\/tx4-series-tx4-s-economic-dual-display-pid-temperature-controller\/\" aria-label=\"View TX4-S product details\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/tx4-s-probe-response-product-reference.avif\" width=\"1000\" height=\"1000\" alt=\"TX4-S Sensor Response: Separate Probe Lag from Controller Timing  title=\" data-image-role=\"product\" tx4-s sensor response: separate probe lag from controller timing title =\"\"><\/a><figcaption>Official TX4-S product photograph. Original markings and source clarity are retained; the image is not a test or configuration record. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-tx4-s-official.png\">View source image<\/a><\/figcaption><\/figure>\n<h2 id=\"standard-engineering-response-criterion-example\"><span class=\"ez-toc-section\" id=\"Standard_Engineering_Response-Criterion_Example\"><\/span>Standard Engineering Response-Criterion Example<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assume a hypothetical sensor is exposed to a temperature step from 20 \u00b0C to 100 \u00b0C under a specified laboratory method. The size of that step is 100 \u2212 20 = 80 \u00b0C. The 63.2% criterion is referenced to the change, not to the final temperature alone.<\/p>\n<p>The corresponding temperature is 20 + 0.632 \u00d7 80 = 70.56 \u00b0C, or about 70.6 \u00b0C. A hypothetical trace reaching 70.6 \u00b0C after 4 seconds would have a 4-second 63.2% response under that test. It would not mean that the sensor reaches 100 \u00b0C in 4 seconds.<\/p>\n<p>For comparison, the 90% criterion for the same step is 20 + 0.90 \u00d7 80 = 92 \u00b0C. The time at which the trace reaches 92 \u00b0C must be read from the trace or calculated from a justified model. Do not treat 4 seconds at 63.2% as 4 seconds at 90%.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Criterion<\/th>\n<th scope=\"col\">Calculation<\/th>\n<th scope=\"col\">Temperature<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Initial condition<\/td>\n<td>Defined starting value<\/td>\n<td>20 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Step size<\/td>\n<td>100 \u2212 20<\/td>\n<td>80 \u00b0C change<\/td>\n<\/tr>\n<tr>\n<td>63.2% of the change<\/td>\n<td>20 + 0.632 \u00d7 80<\/td>\n<td>70.56 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>90% of the change<\/td>\n<td>20 + 0.90 \u00d7 80<\/td>\n<td>92 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Final condition<\/td>\n<td>Defined final value<\/td>\n<td>100 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>This arithmetic only establishes temperatures corresponding to the stated criteria. Real assemblies may have several thermal paths, nonuniform contact and more than one apparent time constant. It does not establish a first-order model, a TX4-S sampling period or a finished machine&#39;s protective response.<\/p>\n<figure data-role=\"technical\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/tx4-s-probe-response-decision.svg\" width=\"1200\" height=\"675\" alt=\"TX4-S Sensor Response: Separate Probe Lag from Controller Timing  title=\" data-image-role=\"technical\" tx4-s sensor response: separate probe lag from controller timing title =\"\"><figcaption>Conceptual Engineering Diagram. The 63.2% and 90% criteria apply to the hypothetical 80 \u00b0C change; the corresponding temperatures are 70.56 \u00b0C and 92 \u00b0C. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/tx4-s-probe-response-decision.svg\">View source image<\/a><\/figcaption><\/figure>\n<h2 id=\"which-delays-belong-to-the-measurement-chain\"><span class=\"ez-toc-section\" id=\"Which_Delays_Belong_to_the_Measurement_Chain\"><\/span>Which Delays Belong to the Measurement Chain?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Start with the physical process. The heat source and the product may change at different times and positions. A reference probe at one point cannot automatically define the exact temperature history at another point. State the measurand and the physical location before comparing traces.<\/p>\n<p>Next consider the installed probe. Its geometry, contact, insertion, protective parts and surrounding flow govern how it exchanges heat with the process. Follow the sensor manufacturer&#39;s mounting instructions and retain the assembly description. Do not use a guessed universal immersion depth or a photograph-derived dimension as an acceptance rule.<\/p>\n<p>Then record the configured controller input and any relevant processing settings documented for the supplied unit. Use the <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/11\/TX4.pdf\">TX4 series instruction manual<\/a> with the actual order code. Do not assume that a parameter exists or has a particular value merely because another controller offers it.<\/p>\n<p>Finally, identify how the observations were collected. A human reading a display every 10 seconds, a video recording and an independent data logger create different timing records. The logging interval is not necessarily the controller&#39;s input-conversion interval. Preserve both when known, and state which timing uncertainty affects the result.<\/p>\n<h2 id=\"how-should-an-oem-compare-two-probe-assemblies\"><span class=\"ez-toc-section\" id=\"How_Should_an_OEM_Compare_Two_Probe_Assemblies\"><\/span>How Should an OEM Compare Two Probe Assemblies?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li>Specify the process point, temperature transition, response criterion and allowed operating conditions. Decide whether the test assesses the probe, the complete input chain or the full machine.<\/li>\n<li>Identify both probes by full part number, sensing type, sheath and protective assembly. Confirm compatibility with the actual TX4-S input configuration.<\/li>\n<li>Keep the installation and test environment comparable. Record mounting, medium, flow and reference placement instead of relying on a shared nominal temperature.<\/li>\n<li>Use suitable synchronized recording equipment. Record the transition start and the criterion-crossing time, including observation and reference limitations.<\/li>\n<li>Compare results only within the defined method. Keep raw traces and note whether the final state was sufficiently established for the chosen criterion.<\/li>\n<li>Recheck the machine after an approved change. A faster probe can change control-loop behavior, noise susceptibility or the process relationship; it is not automatically a drop-in improvement.<\/li>\n<\/ol>\n<p>Work on electrical connections, hot processes or moving equipment requires the machine&#39;s approved procedures and qualified personnel. Do not create an improvised temperature step that exceeds probe or equipment limits. Maintain any independent protective system while ordinary control performance is evaluated.<\/p>\n<h2 id=\"what-decision-should-the-comparison-support\"><span class=\"ez-toc-section\" id=\"What_Decision_Should_the_Comparison_Support\"><\/span>What Decision Should the Comparison Support?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use the record to choose the next investigation, not simply to label one component \u201cslow.\u201d If the installed probe is the limiting thermal element, review its assembly with the probe supplier. If two suitable probes show similar physical behavior but the recorded indication differs, investigate configuration and observation timing with the controller documentation.<\/p>\n<p>Preserve functional tradeoffs. Changing a grounded junction to improve thermal response can affect electrical isolation; reducing protection can affect mechanical or environmental suitability. Those issues require separate evidence. A shorter measured response under one method does not prove that the alternative is suitable for the complete application.<\/p>\n<p>For a <a href=\"https:\/\/www.wehopower.com\/hi\/product\/tx4-series-tx4-s-economic-dual-display-pid-temperature-controller\/\">TX4-S input-chain review<\/a>, send WEHO the order code, configured input, probe specification, installed assembly description and response record. Include the percentage criterion and test conditions. This gives the supplier a defined question and avoids requesting a generic \u201cfast sensor\u201d without a process requirement.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"is-a-display-refresh-time-the-same-as-probe-response-time\"><span class=\"ez-toc-section\" id=\"Is_a_display_refresh_time_the_same_as_probe_response_time\"><\/span>Is a display refresh time the same as probe response time?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Display timing describes an electronic or presentation stage; probe response describes thermal behavior under stated conditions. A complete observation can include both, so identify the stage being measured.<\/p>\n<h3 id=\"is-63-2-calculated-from-zero-degrees\"><span class=\"ez-toc-section\" id=\"Is_632_calculated_from_zero_degrees\"><\/span>Is 63.2% calculated from zero degrees?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Apply the percentage to the temperature change and add the initial value. For the hypothetical 20-to-100 \u00b0C step, the 63.2% criterion is 70.56 \u00b0C.<\/p>\n<h3 id=\"can-an-air-test-response-be-compared-with-a-water-test-response\"><span class=\"ez-toc-section\" id=\"Can_an_air-test_response_be_compared_with_a_water-test_response\"><\/span>Can an air-test response be compared with a water-test response?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Not as a like-for-like result. The surrounding medium and its movement affect heat transfer. Request comparable methods or assess each assembly under the conditions relevant to the process.<\/p>\n<h3 id=\"will-a-faster-probe-always-improve-a-tx4-s-loop\"><span class=\"ez-toc-section\" id=\"Will_a_faster_probe_always_improve_a_TX4-S_loop\"><\/span>Will a faster probe always improve a TX4-S loop?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. The changed assembly can affect other thermal and electrical behavior. Verify compatibility and repeat the relevant machine acceptance tests after an authorized change.<\/p>\n<h3 id=\"does-this-article-specify-a-tx4-s-response-time-limit\"><span class=\"ez-toc-section\" id=\"Does_this_article_specify_a_TX4-S_response-time_limit\"><\/span>Does this article specify a TX4-S response-time limit?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. It explains how to define and compare a measurement method. Any controller-specific timing claim must come from the applicable WEHO documentation for the supplied configuration.<\/p>","protected":false},"excerpt":{"rendered":"<p>Separate TX4-S probe response from display and recording delays. Define the response criterion and send WEHO the input and installed-probe details.<\/p>","protected":false},"author":2,"featured_media":22085,"parent":0,"menu_order":40,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-22099","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/hi\/wp-json\/wp\/v2\/news\/22099","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/hi\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/hi\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/hi\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/hi\/wp-json\/wp\/v2\/comments?post=22099"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/hi\/wp-json\/wp\/v2\/news\/22099\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/hi\/wp-json\/wp\/v2\/media\/22085"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/hi\/wp-json\/wp\/v2\/media?parent=22099"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/hi\/wp-json\/wp\/v2\/news_category?post=22099"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}