{"id":22004,"date":"2026-11-14T10:55:27","date_gmt":"2026-11-14T02:55:27","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/whpu-500-low-voltage-warning-time\/"},"modified":"2026-11-14T10:55:27","modified_gmt":"2026-11-14T02:55:27","slug":"whpu-500-low-voltage-warning-time","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/","title":{"rendered":"WHPU-500 Low-Voltage Warning: Check Minimum Lead Time"},"content":{"rendered":"<p><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>WHPU-500 12 V columns list a 10.5 \u00b1 0.5 V alarm and 10 \u00b1 0.5 V low-voltage protection threshold.<\/li>\n<li>The published function describes an alarm first, then shutdown as voltage continues falling.<\/li>\n<li>Overlapping numerical intervals do not overturn that sequence or specify a minimum warning time.<\/li>\n<li>Specify the required alarm-to-output-loss sequence and verify the delivered configuration.<\/li>\n<\/ul>\n<figure class=\"article-figure hero\" data-asset=\"hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/it\/product\/whpu-500-dc-to-ac-pure-sine-wave-power-inverter-with-charger\/\" aria-label=\"WHPU-500 family details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/whpu-500-application-da85781f45.avif\" alt=\"WHPU-500 Low-Voltage Warning: Check Minimum Lead Time  title=\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" whpu-500 low-voltage warning: check minimum lead time title =\"\"><\/a><figcaption>AI-assisted application illustration retaining the official WHPU-500 family product image. The connected equipment context is not a measured low-voltage warning, shutdown sequence or guaranteed warning duration. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/source-whpu-500-application-reused-master-1e0fcfe0.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Sommario<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Attiva\/disattiva Sommario\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Attiva\/disattiva<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#Why_is_a_nominal_voltage_gap_insufficient_for_a_warning_requirement\" >Why is a nominal voltage gap insufficient for a warning requirement?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#What_do_the_published_12_V_thresholds_actually_say\" >What do the published 12 V thresholds actually say?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#How_do_the_tolerance_intervals_change_the_conclusion\" >How do the tolerance intervals change the conclusion?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#When_can_a_voltage_gap_be_converted_into_an_illustrative_time\" >When can a voltage gap be converted into an illustrative time?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#How_should_the_required_sequence_be_verified\" >How should the required sequence be verified?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#What_should_procurement_ask_the_supplier_to_clarify\" >What should procurement ask the supplier to clarify?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#Engineering_FAQ\" >Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#Does_the_05_V_nominal_gap_guarantee_several_seconds_of_warning\" >Does the 0.5 V nominal gap guarantee several seconds of warning?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#Does_interval_overlap_prove_that_shutdown_happens_first\" >Does interval overlap prove that shutdown happens first?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#Can_a_slow-ramp_result_qualify_a_fast_voltage_step\" >Can a slow-ramp result qualify a fast voltage step?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/it\/news\/whpu-500-low-voltage-warning-time\/#Is_the_recovery_threshold_another_warning_threshold\" >Is the recovery threshold another warning threshold?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"why-is-a-nominal-voltage-gap-insufficient-for-a-warning-requirement\"><span class=\"ez-toc-section\" id=\"Why_is_a_nominal_voltage_gap_insufficient_for_a_warning_requirement\"><\/span>Why is a nominal voltage gap insufficient for a warning requirement?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A voltage difference is not a time specification. A buyer who needs a warning before loss of AC output must consider threshold tolerances, the rate of input-voltage change and the behavior of the alarm and protection functions. Subtracting two nominal voltages leaves those conditions unresolved.<\/p>\n<p>IL <a href=\"https:\/\/www.wehopower.com\/it\/product\/whpu-500-dc-to-ac-pure-sine-wave-power-inverter-with-charger\/\">WHPU-500 inverter and charger information<\/a> lists separate alarm and protection thresholds for its 12 V and 24 V input columns. This article examines the published 12 V values.<\/p>\n<p>The low-voltage function description states an alarm first, followed by shutdown as voltage continues falling. That qualitative sequence is accepted here; the separate question is whether a minimum warning duration is documented for the required conditions.<\/p>\n<p>For an OEM writing a warning requirement, the decision is whether the available evidence supports a minimum lead time. If it does not, specify the required behavior and obtain applicable information or qualification evidence rather than assuming a favorable result.<\/p>\n<h2 id=\"what-do-the-published-12-v-thresholds-actually-say\"><span class=\"ez-toc-section\" id=\"What_do_the_published_12_V_thresholds_actually_say\"><\/span>What do the published 12 V thresholds actually say?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The product table lists low-voltage alarm at 10.5 \u00b1 0.5 V and low-voltage protection at 10 \u00b1 0.5 V in the 12 V columns. It also lists a separate low-voltage recovery value of 12.3 \u00b1 0.5 V. These are different functions and should remain separate in the requirement.<\/p>\n<p>The nominal falling-voltage difference is 10.5 V \u2212 10.0 V = 0.5 V. That calculation is correct as a comparison of nominal values. It becomes misleading only when used as a guaranteed separation or converted directly into a promised warning time.<\/p>\n<p>The cited table does not describe how alarm and cutoff tolerances track within a unit. Nor does it provide a complete minimum warning-time specification for every input trajectory and load. Its alarm-first functional statement remains relevant. Do not infer independent threshold extremes, perfect tracking, or a minimum delay that the table does not specify.<\/p>\n<p>The official photograph shows the 500 W family form and a WHPU-500W model banner. It does not establish which 12 V or 24 V table column applies to a delivered unit. Confirm the complete input\/output configuration; the photograph does not establish the internal implementation or timing of protection functions.<\/p>\n<figure class=\"article-figure product\" data-asset=\"product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/it\/product\/whpu-500-dc-to-ac-pure-sine-wave-power-inverter-with-charger\/\" aria-label=\"WHPU-500 family details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/whpu-500-product-reference-e7ce1935d7.avif\" alt=\"WHPU-500 Low-Voltage Warning: Check Minimum Lead Time  title=\" width=\"1000\" height=\"1000\" decoding=\"async\" whpu-500 low-voltage warning: check minimum lead time title =\"\"><\/a><figcaption>Official WHPU-500 family product artwork. It does not establish every input\/output ordering option or the certification implied by source-artwork logos. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/source-whpu-500-official-d5e89a9a.jpg\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"how-do-the-tolerance-intervals-change-the-conclusion\"><span class=\"ez-toc-section\" id=\"How_do_the_tolerance_intervals_change_the_conclusion\"><\/span>How do the tolerance intervals change the conclusion?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use a <strong>Published-Threshold Interval Example<\/strong> based on the 12 V table. This is interval arithmetic on manufacturer values, not a measurement of a WHPU-500.<\/p>\n<p>Alarm interval = 10.5 V \u00b1 0.5 V = 10.0\u201311.0 V.<\/p>\n<p>Protection interval = 10.0 V \u00b1 0.5 V = 9.5\u201310.5 V.<\/p>\n<p>Their numerical overlap is 10.0\u201310.5 V. The ranges therefore do not, by themselves, establish a positive guaranteed separation. A conservative uncoupled comparison gives 10.0 V \u2212 10.5 V = \u22120.5 V. That bound is not a prediction of a real unit or a reason to contradict the stated alarm-first behavior; it shows why separate tolerance ranges cannot quantify the guaranteed lead time.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Funzione<\/th>\n<th scope=\"col\">Published 12 V value<\/th>\n<th scope=\"col\">Calculated interval<\/th>\n<th scope=\"col\">Timing information to confirm<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Low-voltage alarm<\/td>\n<td>10.5 \u00b1 0.5 V<\/td>\n<td>10.0\u201311.0 V<\/td>\n<td>Alarm indication and response timing<\/td>\n<\/tr>\n<tr>\n<td>Low-voltage protection<\/td>\n<td>10.0 \u00b1 0.5 V<\/td>\n<td>9.5\u201310.5 V<\/td>\n<td>Minimum alarm-to-output-loss duration<\/td>\n<\/tr>\n<tr>\n<td>Low-voltage recovery<\/td>\n<td>12.3 \u00b1 0.5 V<\/td>\n<td>11.8\u201312.8 V<\/td>\n<td>Complete output-return sequence<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The practical result is a distinction between function and timing. Use the stated alarm-first behavior as the functional description. An application that needs a guaranteed duration still requires timing evidence under its specified input and load conditions.<\/p>\n<p>Ask whether the offered revision specifies a minimum lead time or voltage separation under the required conditions. A timing statement tied to the actual voltage trajectory is more useful to that requirement than another nominal threshold value.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/whpu-500-threshold-intervals-b1a86bd916.svg\" alt=\"WHPU-500 Low-Voltage Warning: Check Minimum Lead Time  title=\" width=\"1200\" height=\"675\" decoding=\"async\" whpu-500 low-voltage warning: check minimum lead time title =\"\"><\/div><figcaption>Conceptual Engineering Diagram. WHPU-500 states an alarm-first function; overlapping published 12 V intervals do not quantify a guaranteed minimum warning time. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/source-whpu-500-threshold-intervals-b1a86bd9.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<h2 id=\"when-can-a-voltage-gap-be-converted-into-an-illustrative-time\"><span class=\"ez-toc-section\" id=\"When_can_a_voltage_gap_be_converted_into_an_illustrative_time\"><\/span>When can a voltage gap be converted into an illustrative time?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A voltage gap can be converted into time only under a defined voltage trajectory and response model. For an ideal linear fall with slope magnitude r, the interval between two fixed crossing voltages is:<\/p>\n<p>Crossing interval = (alarm voltage \u2212 cutoff voltage) \u00f7 r.<\/p>\n<p>For a <strong>Hypothetical Linear-Ramp Example<\/strong>, assume fixed thresholds exactly at 10.5 V and 10.0 V, a constant fall of 0.1 V\/s and no additional event delays. The crossing interval is 0.5 V \u00f7 0.1 V\/s = 5 s. With the same ideal thresholds and a fall of 1 V\/s, it becomes 0.5 s.<\/p>\n<p>Neither figure is a WHPU-500 warning-time specification. The example assumes away threshold variation and response delays to show why the input trajectory matters. A fast step can cross both nominal levels within an interval that a slow ramp does not represent.<\/p>\n<p>The relevant alarm may also need to be noticed or captured by another system. Define whether the requirement concerns a local indication, an audible event, a documented electrical signal or a machine response. Do not infer a remote alarm interface from a protection-table description.<\/p>\n<h2 id=\"how-should-the-required-sequence-be-verified\"><span class=\"ez-toc-section\" id=\"How_should_the_required_sequence_be_verified\"><\/span>How should the required sequence be verified?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li>Identify the actual 12 V configuration, applicable product revision and intended load. Record the required warning event and what counts as loss of usable output.<\/li>\n<li>Define the input-voltage trajectories relevant to the equipment. Include their starting conditions, ramp or step characteristics and permitted operating limits.<\/li>\n<li>Establish synchronized observation of input voltage at the inverter, the applicable alarm event and output behavior. Select equipment and timing resolution appropriate to the requirement.<\/li>\n<li>Perform the authorized qualification procedure using a suitable controlled source and load. Do not deliberately over-discharge a battery to create an undocumented test condition.<\/li>\n<li>Record the event order, observed thresholds and elapsed time with the test conditions. Compare the results with the explicit requirement rather than with the nominal 0.5 V subtraction alone.<\/li>\n<li>Evaluate the separate recovery sequence if the equipment depends on it. Keep alarm, output loss and output return as distinct observations.<\/li>\n<\/ol>\n<p>Use qualified personnel and the equipment safety and isolation procedures. The public product page is not a complete installation or destructive-test instruction. Avoid repeated cycling outside the applicable operating conditions while trying to discover an undocumented margin.<\/p>\n<h2 id=\"what-should-procurement-ask-the-supplier-to-clarify\"><span class=\"ez-toc-section\" id=\"What_should_procurement_ask_the_supplier_to_clarify\"><\/span>What should procurement ask the supplier to clarify?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Ask for the offered revision&#39;s applicable threshold conditions, definition of the alarm event and any guaranteed minimum alarm-to-output-loss time. If the machine requires a minimum warning duration, provide the input trajectory and load conditions that make that duration meaningful.<\/p>\n<p>IL <a href=\"https:\/\/www.wehopower.com\/it\/product\/whpu-500-dc-to-ac-pure-sine-wave-power-inverter-with-charger\/\">WHPU-500 12 V protection reference<\/a> provides the published starting values. It does not replace the complete ordering record or the OEM&#39;s qualification of the required sequence.<\/p>\n<p>Use the <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/low-voltage-warning-sequence.csv\">threshold and event-sequence worksheet<\/a> to keep published intervals, supplier clarifications and actual observations separate. <a href=\"https:\/\/www.wehopower.com\/it\/contact\/\">Send WEHO the warning-time requirement<\/a> with the exact configuration, voltage trajectory, load and event definition. This makes the unresolved question specific enough to evaluate.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"does-the-0-5-v-nominal-gap-guarantee-several-seconds-of-warning\"><span class=\"ez-toc-section\" id=\"Does_the_05_V_nominal_gap_guarantee_several_seconds_of_warning\"><\/span>Does the 0.5 V nominal gap guarantee several seconds of warning?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The nominal gap does not guarantee a warning time. Time depends on the actual threshold relationship, input trajectory and event response. The separate tolerance intervals alone do not quantify a minimum lead time; they do not invalidate the published alarm-first function.<\/p>\n<h3 id=\"does-interval-overlap-prove-that-shutdown-happens-first\"><span class=\"ez-toc-section\" id=\"Does_interval_overlap_prove_that_shutdown_happens_first\"><\/span>Does interval overlap prove that shutdown happens first?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. The page describes an alarm-first low-voltage function. Overlapping numeric intervals do not disprove that stated sequence, and they do not quantify a minimum time. Obtain applicable timing information and verify the required behavior under defined conditions.<\/p>\n<h3 id=\"can-a-slow-ramp-result-qualify-a-fast-voltage-step\"><span class=\"ez-toc-section\" id=\"Can_a_slow-ramp_result_qualify_a_fast_voltage_step\"><\/span>Can a slow-ramp result qualify a fast voltage step?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A slow ramp and a fast step are different input events. Qualify the trajectories relevant to the equipment and use observation timing capable of resolving the required alarm-to-output-loss interval.<\/p>\n<h3 id=\"is-the-recovery-threshold-another-warning-threshold\"><span class=\"ez-toc-section\" id=\"Is_the_recovery_threshold_another_warning_threshold\"><\/span>Is the recovery threshold another warning threshold?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Recovery is a separate return condition. Its voltage value does not establish a minimum falling-voltage warning duration or the complete output-return sequence. Record recovery independently if the equipment depends on it.<\/p>","protected":false},"excerpt":{"rendered":"<p>Review WHPU-500 alarm-first behavior and voltage tolerances. Separate sequence from minimum warning time, then send WEHO your required conditions.<\/p>","protected":false},"author":2,"featured_media":21989,"parent":0,"menu_order":42,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-22004","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/it\/wp-json\/wp\/v2\/news\/22004","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/it\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/it\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/it\/wp-json\/wp\/v2\/comments?post=22004"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/it\/wp-json\/wp\/v2\/news\/22004\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/it\/wp-json\/wp\/v2\/media\/21989"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/it\/wp-json\/wp\/v2\/media?parent=22004"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/it\/wp-json\/wp\/v2\/news_category?post=22004"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}