{"id":24007,"date":"2026-11-25T10:12:45","date_gmt":"2026-11-25T02:12:45","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/radiated-field-correction-chain-units\/"},"modified":"2026-11-25T10:12:45","modified_gmt":"2026-11-25T02:12:45","slug":"radiated-field-correction-chain-units","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/","title":{"rendered":"Radiated Field Conversion: Apply Antenna and Path Factors Once"},"content":{"rendered":"<div class=\"weho-blog\">\n<p>Convert receiver voltage into field strength using the correct antenna factor and the losses and gains of the actual measurement path. Before adding corrections, establish whether the instrument&#39;s displayed result already includes them.<\/p>\n<div class=\"key-takeaways\"><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Preserve the reference plane and units of the raw reading.<\/li>\n<li>Add path losses and subtract external gain once.<\/li>\n<li>Match antenna-factor type and calibration conditions.<\/li>\n<li>Keep conversion separate from spatial search and detector selection.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"K11-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/ko\/product\/ndr-dinrail-120w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"NDR-120-24 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/5c902365198df58f-ndr-120-24-application.webp\" alt=\"NDR-120-24 product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" title=\"\"><\/a><figcaption>Application illustration of NDR-120-24 in an equipment setting; not a customer installation photo. Scene created with AI assistance. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/c098f4405daa5c57-application-master.webp\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#1-identify-which-quantity-the-report-displays\">1. Identify which quantity the report displays<\/a><\/li>\n<li><a href=\"#2-write-the-reference-plane-equation\">2. Write the reference-plane equation<\/a><\/li>\n<li><a href=\"#3-recalculate-a-hypothetical-correction-chain\">3. Recalculate a hypothetical correction chain<\/a><\/li>\n<li><a href=\"#4-check-active-antennas-and-composite-factors\">4. Check active antennas and composite factors<\/a><\/li>\n<li><a href=\"#5-verify-one-reproducible-correction-chain\">5. Verify one reproducible correction chain<\/a><\/li>\n<li><a href=\"#6-request-the-component-and-report-evidence\">6. Request the component and report evidence<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\ubaa9\ucc28<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\ubaa9\ucc28 \ud1a0\uae00\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\ube44\ub140\uc7a5<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#1_Identify_which_quantity_the_report_displays\" >1. Identify which quantity the report displays<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#2_Write_the_reference-plane_equation\" >2. Write the reference-plane equation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#3_Recalculate_a_hypothetical_correction_chain\" >3. Recalculate a hypothetical correction chain<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#4_Check_active_antennas_and_composite_factors\" >4. Check active antennas and composite factors<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#5_Verify_one_reproducible_correction_chain\" >5. Verify one reproducible correction chain<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#6_Request_the_component_and_report_evidence\" >6. Request the component and report evidence<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#Frequently_Asked_Questions\" >\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#Can_a_receiver_value_in_dB%C2%B5V_be_compared_directly_with_a_dB%C2%B5Vm_limit\" >Can a receiver value in dB\u00b5V be compared directly with a dB\u00b5V\/m limit?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#Should_external_preamplifier_gain_be_added_to_the_receiver_reading\" >Should external preamplifier gain be added to the receiver reading?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#Does_an_active_antenna_need_its_built-in_gain_corrected_separately\" >Does an active antenna need its built-in gain corrected separately?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/ko\/news\/radiated-field-correction-chain-units\/#Does_correct_field_conversion_establish_equipment_compliance\" >Does correct field conversion establish equipment compliance?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"1-identify-which-quantity-the-report-displays\"><span class=\"ez-toc-section\" id=\"1_Identify_which_quantity_the_report_displays\"><\/span>1. Identify which quantity the report displays<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A buyer reviewing an equipment emission result can encounter a receiver reading in dB\u00b5V and a reported field in dB\u00b5V\/m. Those are different quantities. The conversion requires the measurement antenna and path information, not a simple change to the axis label or a comparison against a limit in incompatible units.<\/p>\n<p>\uadf8\ub9cc\ud07c <a href=\"https:\/\/www.wehopower.com\/ko\/product\/ndr-dinrail-120w-ac-to-dc-single-output-switching-power-supply\/\">WEHO NDR-120-24 product reference<\/a> identifies one source in an equipment context. The following measurement-chain example does not establish that supply&#39;s emissions or certification. Ask for exact-model evidence while reviewing the complete equipment&#39;s antenna, receiver and correction record independently.<\/p>\n<p><a href=\"https:\/\/download.tek.com\/document\/EMI%20Pre-Compliance%20Testing_App-Note_37W-61518-0_02.pdf\" target=\"_blank\" rel=\"noopener\">Tektronix&#39;s EMI pre-compliance note<\/a> explicitly relates receiver voltage, antenna factor, cable loss and external preamplifier gain to a field result. Its software can perform this calculation automatically when the accessory information is configured. That makes correction-state traceability essential before any manual recalculation.<\/p>\n<h2 id=\"2-write-the-reference-plane-equation\"><span class=\"ez-toc-section\" id=\"2_Write_the_reference-plane_equation\"><\/span>2. Write the reference-plane equation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For an electric-field measurement with the declared antenna factor, a useful logarithmic chain is E = Vreceiver + AF + Lcable + Lother \u2212 Gexternal. E is in dB\u00b5V\/m, Vreceiver in dB\u00b5V, AF in dB\/m and the path gains or losses in dB. Define the included path before applying the equation.<\/p>\n<p>Antenna factor relates the antenna-terminal voltage to the relevant incident field under its calibration conditions. Cable loss reverses attenuation between that plane and the receiver. An external preamplifier increases the receiver voltage, so its gain is subtracted when recovering the corresponding field value. Additional attenuation must also be included if present.<\/p>\n<p>The official <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/86318\" target=\"_blank\" rel=\"noopener\">CISPR 16-2-3 overview<\/a> identifies the radiated-disturbance measurement framework and separate uncertainty references. This arithmetic worksheet does not supply the complete applicable method, site qualification, uncertainty budget or product limit. Those remain part of the actual laboratory decision.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Quantity<\/th>\n<th scope=\"col\">Typical record unit<\/th>\n<th scope=\"col\">Role in this chain<\/th>\n<th scope=\"col\">Check before use<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Receiver voltage<\/td>\n<td>dB\u00b5V<\/td>\n<td>Starting observation<\/td>\n<td>Raw or already corrected?<\/td>\n<\/tr>\n<tr>\n<td>Electric antenna factor<\/td>\n<td>dB\/m<\/td>\n<td>Add to recover field<\/td>\n<td>Correct antenna and frequency?<\/td>\n<\/tr>\n<tr>\n<td>Cable\/attenuator loss<\/td>\n<td>dB<\/td>\n<td>Add path attenuation<\/td>\n<td>Included elsewhere already?<\/td>\n<\/tr>\n<tr>\n<td>External preamplifier gain<\/td>\n<td>dB<\/td>\n<td>Subtract external gain<\/td>\n<td>Correct gain state and reference planes?<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>A label such as \u201cantenna correction\u201d is insufficient when the file may contain a composite factor. Determine whether the saved values represent the antenna alone, antenna plus cable or a complete path. A mathematically correct sum of incorrectly interpreted files still produces an invalid field estimate.<\/p>\n<h2 id=\"3-recalculate-a-hypothetical-correction-chain\"><span class=\"ez-toc-section\" id=\"3_Recalculate_a_hypothetical_correction_chain\"><\/span>3. Recalculate a hypothetical correction chain<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assume an invented raw receiver reading of 35 dB\u00b5V at one frequency. Assume the applicable electric antenna factor is 18 dB\/m, cable loss is 2 dB and external preamplifier gain is 20 dB. Assume no other attenuator or path correction and no compression or mismatch correction in this simplified example.<\/p>\n<p>The converted electric field is 35 + 18 + 2 \u2212 20 = 35 dB\u00b5V\/m. The net numerical correction is zero in this chosen example, but the physical quantity and unit still change. Equal numbers do not mean receiver voltage and electric field are interchangeable.<\/p>\n<p>Converting the field result to linear units gives 10^(35\/20) \u2248 56.23 \u00b5V\/m. The raw 35 dB\u00b5V receiver voltage separately corresponds to 56.23 \u00b5V at the receiver reference plane. Their numerical equality follows from the invented net-zero factor, not from a general relationship between volts and volts per metre.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"K11-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/4d57336e36fff9b8-technical.svg\" alt=\"Illustrative logarithmic correction waterfall separates receiver voltage from field strength and external gain.\" width=\"1200\" height=\"675\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Assumed 35dB\u00b5V raw voltage, +18dB\/m electric antenna factor, +2dB cable loss and \u221220dB external gain yield 35dB\u00b5V\/m; no equipment measurement implied. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/4d57336e36fff9b8-technical.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>If the 20 dB external gain were omitted, the calculation would produce 55 dB\u00b5V\/m. That corresponds to approximately 562.34 \u00b5V\/m, ten times the correctly converted example field amplitude. The error is a factor of ten in field amplitude, not a statement about radiated power or the equipment&#39;s actual emission.<\/p>\n<p>Now suppose the receiver instead displays an already corrected 35 dB\u00b5V\/m. Adding the 18 dB\/m antenna factor again would produce a numerical 53 dB\u00b5V\/m claim, an 18 dB overstatement. The safe arithmetic is to retain the displayed corrected result and its configuration, or reconstruct from genuinely raw data once.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Invented processing<\/th>\n<th scope=\"col\">Calculation<\/th>\n<th scope=\"col\">Reported field<\/th>\n<th scope=\"col\">Disposition<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Complete raw-data chain<\/td>\n<td>35 + 18 + 2 \u2212 20<\/td>\n<td>35 dB\u00b5V\/m<\/td>\n<td>Correct under declared assumptions<\/td>\n<\/tr>\n<tr>\n<td>External gain omitted<\/td>\n<td>35 + 18 + 2<\/td>\n<td>55 dB\u00b5V\/m<\/td>\n<td>20 dB error<\/td>\n<\/tr>\n<tr>\n<td>Antenna factor added twice<\/td>\n<td>Corrected 35 + 18<\/td>\n<td>53 dB\u00b5V\/m<\/td>\n<td>18 dB duplicate correction<\/td>\n<\/tr>\n<tr>\n<td>Raw voltage relabeled<\/td>\n<td>No documented chain<\/td>\n<td>Unsupported field claim<\/td>\n<td>Numerical coincidence is insufficient<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"4-check-active-antennas-and-composite-factors\"><span class=\"ez-toc-section\" id=\"4_Check_active_antennas_and_composite_factors\"><\/span>4. Check active antennas and composite factors<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The applicable factor must describe the antenna actually used. ISED&#39;s <a href=\"https:\/\/www.ised-isde.canada.ca\/site\/spectrum-management-telecommunications\/en\/devices-and-equipment\/radio-equipment-standards\/radio-standards-specifications-rss\/rss-gen-general-requirements-compliance-radio-apparatus\" target=\"_blank\" rel=\"noopener\">RSS-Gen informative antenna-factor annex<\/a> gives an instructive active-loop example: its antenna factor already includes the built-in preamplifier. The separate external-gain term concerns an additional external preamplifier, not that internal gain again.<\/p>\n<p>That annex has a defined radio-apparatus and low-frequency loop context. It does not make its specific magnetic\/electric conversion rules universally applicable to every industrial measurement. Its relevant lesson here is to understand the calibrated reference plane and included functions before composing a measurement chain.<\/p>\n<p>An electric antenna factor and a magnetic antenna factor also have different dimensions. Do not substitute one because the calibration file has similar-looking numbers. Identify the measured field quantity, antenna type, frequency and required limit quantity, then apply the actual method&#39;s conversion conditions where a conversion is justified.<\/p>\n<p>Path factors vary with frequency. A gain specified at one frequency cannot automatically correct an entire emission sweep. Retain calibration identifiers, the frequency-dependent tables and the software interpolation or correction settings used to produce the result. Preserve an expired or changed calibration as a review issue rather than silently replacing its file.<\/p>\n<figure class=\"article-figure product\" data-asset=\"K11-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/ko\/product\/ndr-dinrail-120w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"NDR-120-24 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/c1d1da3932e864b9-ndr-120-24-product-reference.webp\" alt=\"NDR-120-24 product reference preserving the original housing, visible label and connection features.\" width=\"800\" height=\"800\" decoding=\"async\" title=\"\"><\/a><figcaption>Product appearance reference for NDR-120-24, preserving the source housing, visible label and connections. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/e03f11f17a629a7f-product-original.jpg\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"5-verify-one-reproducible-correction-chain\"><span class=\"ez-toc-section\" id=\"5_Verify_one_reproducible_correction_chain\"><\/span>5. Verify one reproducible correction chain<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Identify the display state.<\/strong> Record units, correction enablement and raw-data availability. Verify whether the selected observation is receiver voltage or an already converted field value.<\/li>\n<li><strong>Map the physical path.<\/strong> Record antenna, cables, attenuators and external amplifier states. Verify reference planes against the actual connected equipment.<\/li>\n<li><strong>Match the factor files.<\/strong> Record calibration identifiers, frequency and included functions. Verify that no gain or loss appears in two different composite factors.<\/li>\n<li><strong>Recalculate a point.<\/strong> Record the raw value and every signed term. Verify unit consistency and reproduce the displayed result within the relevant processing precision.<\/li>\n<li><strong>Release the bounded result.<\/strong> Record the corrected field, method and uncertainty information. Verify the required detector and spatial-search evidence separately before making the equipment acceptance decision.<\/li>\n<\/ol>\n<p>Changing a cable or amplifier after calibration mapping changes the measurement chain. Review that change even when the receiver model and antenna remain the same. A saved setup file is useful only if its accessory identities and gain states still match the physical arrangement used for the measurement.<\/p>\n<h2 id=\"6-request-the-component-and-report-evidence\"><span class=\"ez-toc-section\" id=\"6_Request_the_component_and_report_evidence\"><\/span>6. Request the component and report evidence<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For an <a href=\"https:\/\/www.wehopower.com\/ko\/product\/ndr-dinrail-120w-ac-to-dc-single-output-switching-power-supply\/\">NDR-120-24 equipment review<\/a>, provide the equipment configuration, intended market and relevant emission report. Include raw\/corrected units and the factor-chain record when a reported value is unclear. Request matching product documentation while the EMC laboratory retains responsibility for the complete equipment measurement and applicable acceptance decision.<\/p>\n<h2 id=\"frequently-asked-questions\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"can-a-receiver-value-in-db-v-be-compared-directly-with-a-db-v-m-limit\"><span class=\"ez-toc-section\" id=\"Can_a_receiver_value_in_dB%C2%B5V_be_compared_directly_with_a_dB%C2%B5Vm_limit\"><\/span>Can a receiver value in dB\u00b5V be compared directly with a dB\u00b5V\/m limit?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Receiver voltage and field strength are different quantities. Establish the appropriate antenna and path conversion before comparing a field result with a compatible limit.<\/p>\n<h3 id=\"should-external-preamplifier-gain-be-added-to-the-receiver-reading\"><span class=\"ez-toc-section\" id=\"Should_external_preamplifier_gain_be_added_to_the_receiver_reading\"><\/span>Should external preamplifier gain be added to the receiver reading?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. In the declared reconstruction equation, external gain is subtracted because it increased the observed receiver voltage. Check whether the software or a composite factor already includes that gain.<\/p>\n<h3 id=\"does-an-active-antenna-need-its-built-in-gain-corrected-separately\"><span class=\"ez-toc-section\" id=\"Does_an_active_antenna_need_its_built-in_gain_corrected_separately\"><\/span>Does an active antenna need its built-in gain corrected separately?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Not necessarily. Its calibrated factor may already include built-in amplification. Use the actual calibration definition instead of applying an additional gain correction by assumption.<\/p>\n<h3 id=\"does-correct-field-conversion-establish-equipment-compliance\"><span class=\"ez-toc-section\" id=\"Does_correct_field_conversion_establish_equipment_compliance\"><\/span>Does correct field conversion establish equipment compliance?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Correct arithmetic is one part of the record. Applicable method, detector, geometry, operating configuration, uncertainty and limit evaluation still require their own evidence.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Convert receiver voltage to field strength with antenna factor, cable loss and external gain while preventing duplicated software or manual corrections.<\/p>","protected":false},"author":2,"featured_media":22647,"parent":0,"menu_order":0,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-24007","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/news\/24007","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/comments?post=24007"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/news\/24007\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/media\/22647"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/media?parent=24007"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/news_category?post=24007"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}