{"id":24734,"date":"2026-11-27T10:15:08","date_gmt":"2026-11-27T02:15:08","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/supplier-8d-containment-corrective-closure\/"},"modified":"2026-11-27T10:15:08","modified_gmt":"2026-11-27T02:15:08","slug":"supplier-8d-containment-corrective-closure","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/","title":{"rendered":"Supplier 8D Closure: Separate Containment from Corrective Action"},"content":{"rendered":"<div class=\"weho-blog\">\n<blockquote>\n<p><strong>Key engineering takeaways<\/strong><\/p>\n<ul>\n<li>Containment protects the affected flow while the problem is investigated.<\/li>\n<li>A permanent action needs verified causes, implementation evidence and effectiveness checks.<\/li>\n<li>Investigate both defect creation and the reason existing controls missed it.<\/li>\n<li>Release containment against agreed evidence, not a completed form alone.<\/li>\n<\/ul>\n<\/blockquote>\n<p>An 8D report should distinguish immediate containment from a verified permanent correction and its effectiveness evidence. Sorting a suspect lot can reduce immediate exposure without changing the process that created the defect. Closing a supplier issue requires a clear chain from problem definition through causes, actions and justified release decisions.<\/p>\n<p>For a purchasing discussion involving the <a href=\"https:\/\/www.wehopower.com\/ko\/product\/wholesale-60w-single-output-din-rail-power-power-supply\/\">WEHO MDR-60-12<\/a>, agree the issue and required records before requesting an 8D response. The product is an enquiry context, not the subject of a reported defect here. The example below is a fictional identification problem with no WEHO incident or corrective-action history asserted.<\/p>\n<figure class=\"article-figure hero\" data-asset=\"K23-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/ko\/product\/wholesale-60w-single-output-din-rail-power-power-supply\/\" aria-label=\"MDR-60-12 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/60bea74f3923e2e9-mdr-60-12-application.webp\" alt=\"MDR-60-12 product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" title=\"\"><\/a><figcaption>Application illustration of MDR-60-12 in an equipment setting; not a customer installation photo. Scene created with AI assistance. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/1bc31a485662a951-application-master.webp\" target=\"_blank\" rel=\"noopener\">\uc6d0\ubcf8 \ud574\uc0c1\ub3c4\uc758 \uc774\ubbf8\uc9c0 \ubcf4\uae30<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>\uc774 \ud398\uc774\uc9c0\uc5d0\uc11c<\/summary>\n<ol>\n<li><a href=\"#define-the-problem-and-containment-boundary\">Define the problem and containment boundary<\/a><\/li>\n<li><a href=\"#verify-occurrence-and-escape-separately\">Verify occurrence and escape separately<\/a><\/li>\n<li><a href=\"#work-through-a-fictional-containment-and-closure-record\">Work through a fictional containment and closure record<\/a><\/li>\n<li><a href=\"#make-closure-criteria-visible-before-execution\">Make closure criteria visible before execution<\/a><\/li>\n<li><a href=\"#execute-an-evidence-based-closure-review\">Execute an evidence-based closure review<\/a><\/li>\n<li><a href=\"#prepare-a-corrective-action-evidence-enquiry\">Prepare a corrective-action evidence enquiry<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Frequently asked questions<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\ubaa9\ucc28<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\ubaa9\ucc28 \ud1a0\uae00\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\ube44\ub140\uc7a5<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Define_the_problem_and_containment_boundary\" >Define the problem and containment boundary<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Verify_occurrence_and_escape_separately\" >Verify occurrence and escape separately<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Work_through_a_fictional_containment_and_closure_record\" >Work through a fictional containment and closure record<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Make_closure_criteria_visible_before_execution\" >Make closure criteria visible before execution<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Execute_an_evidence-based_closure_review\" >Execute an evidence-based closure review<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Prepare_a_corrective-action_evidence_enquiry\" >Prepare a corrective-action evidence enquiry<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Frequently_asked_questions\" >Frequently asked questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Does_sorting_the_suspect_lot_count_as_a_permanent_correction\" >Does sorting the suspect lot count as a permanent correction?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Must_an_8D_investigate_the_escape_cause_separately\" >Must an 8D investigate the escape cause separately?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Can_containment_end_as_soon_as_an_action_is_installed\" >Can containment end as soon as an action is installed?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/ko\/news\/supplier-8d-containment-corrective-closure\/#Does_zero_recurrence_over_a_few_lots_prove_zero_risk\" >Does zero recurrence over a few lots prove zero risk?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"define-the-problem-and-containment-boundary\"><span class=\"ez-toc-section\" id=\"Define_the_problem_and_containment_boundary\"><\/span>Define the problem and containment boundary<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A useful problem statement identifies what was observed, where and when it occurred, the applicable requirement and the affected configuration. Separate observed facts from unverified explanations. A label discrepancy, for example, should describe the mismatched identity and records rather than immediately blaming an operator.<\/p>\n<p><a href=\"https:\/\/asq.org\/quality-resources\/eight-disciplines-8d\" target=\"_blank\" rel=\"noopener\">ASQ&#39;s eight-disciplines overview<\/a> separates interim containment from cause verification and permanent corrective actions. Use that structure to maintain different evidence and owners for immediate protection and systemic change. Completing a sort is not evidence that the original cause has been removed.<\/p>\n<p>Containment needs an explicit population and a method capable of finding the reported condition. Include relevant material in transit, stock, work in process and other locations supported by traceability. Record unresolved scope questions rather than claiming the boundary is complete because the most visible carton was checked.<\/p>\n<p>A temporary screen can introduce its own errors or damage if it requires handling, relabeling or repeated connections. Define approved instructions, identification and disposition before beginning. Verify the screen with controlled references relevant to the condition and retain the results by unit or traceable quantity.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Activity<\/th>\n<th scope=\"col\">Immediate purpose<\/th>\n<th scope=\"col\">Required evidence<\/th>\n<th scope=\"col\">\uadf8\uac83\uc774 \ub9cc\ub4e4\uc5b4\uc9c0\uc9c0 \uc54a\ub294 \uac83\uc740<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Containment<\/td>\n<td>Control suspect flow<\/td>\n<td>Population, screen and dispositions<\/td>\n<td>Removal of the creating cause<\/td>\n<\/tr>\n<tr>\n<td>Cause verification<\/td>\n<td>Explain occurrence and escape<\/td>\n<td>Evidence testing the causal explanation<\/td>\n<td>That a proposed action works<\/td>\n<\/tr>\n<tr>\n<td>Permanent action<\/td>\n<td>Change the responsible process\/control<\/td>\n<td>Approved implementation and verification<\/td>\n<td>Sustained effectiveness by paperwork alone<\/td>\n<\/tr>\n<tr>\n<td>Containment release<\/td>\n<td>Return to agreed normal controls<\/td>\n<td>Predetermined exit criteria and approval<\/td>\n<td>Guaranteed absence of future defects<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"verify-occurrence-and-escape-separately\"><span class=\"ez-toc-section\" id=\"Verify_occurrence_and_escape_separately\"><\/span>Verify occurrence and escape separately<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Occurrence cause explains how the nonconformance was produced. Escape cause explains why the existing controls did not prevent the affected item from reaching the next stage. The two causes can involve different systems, so one action may not address both.<\/p>\n<p>In a fictional identification issue, a variant selection process might create the wrong label, while an incomplete comparison at release might allow it through. Those are hypotheses until supported. Training a person to look more carefully does not by itself verify either mechanism or establish a durable change.<\/p>\n<p><a href=\"https:\/\/www.siemens.com\/en-gb\/technology\/8d-report\/\" target=\"_blank\" rel=\"noopener\">Siemens&#39; 8D explanation<\/a> describes structured problem solving through containment, root-cause work and corrective action. A practical cause record should state the evidence expected if a hypothesis is true and compare it with actual findings. Preserve rejected hypotheses where they explain why an attractive explanation was not adopted.<\/p>\n<p>A controlled reproduction or configuration review can support a cause without requiring unsafe product misuse. Use approved simulation or nonproduction test arrangements when appropriate. Do not intentionally misidentify saleable products or bypass release controls simply to obtain an illustrative failure.<\/p>\n<figure class=\"article-figure product\" data-asset=\"K23-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/ko\/product\/wholesale-60w-single-output-din-rail-power-power-supply\/\" aria-label=\"MDR-60-12 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/00af49cf0d1a3c23-mdr-60-12-product-reference.webp\" alt=\"MDR-60-12 product reference preserving the original housing, visible label and connection features.\" width=\"800\" height=\"800\" decoding=\"async\" title=\"\"><\/a><figcaption>Product appearance reference for MDR-60-12, preserving the source housing, visible label and connections. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/3ab97502e2658a89-product-original.jpg\" target=\"_blank\" rel=\"noopener\">\uc6d0\ubcf8 \ud574\uc0c1\ub3c4\uc758 \uc774\ubbf8\uc9c0 \ubcf4\uae30<\/a><\/figcaption><\/figure>\n<h2 id=\"work-through-a-fictional-containment-and-closure-record\"><span class=\"ez-toc-section\" id=\"Work_through_a_fictional_containment_and_closure_record\"><\/span>Work through a fictional containment and closure record<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assume a fictional lot contains 200 identified assemblies and the agreed concern is one specific label-to-configuration mismatch. An authorized inspection examines all 200 for that condition and records six suspect units and 194 with no observed instance of that condition. Six divided by 200 is an observed 3% discrepancy fraction in the screened lot.<\/p>\n<p>That 3% is not a supplier&#39;s general defect rate, a field failure estimate or proof about other characteristics. The 194 screened units still require all other applicable acceptance evidence. The six suspects remain controlled until their individual dispositions are authorized; the sort does not determine whether rework is technically or contractually acceptable.<\/p>\n<p>Now assume the verified occurrence cause is an incorrect approved-data selection rule and the verified escape cause is a missing identity comparison. A proposed permanent action changes the selection logic and adds the required comparison. Challenge the revised path with approved correct and incorrect identity combinations before production release.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Fictional stage<\/th>\n<th scope=\"col\">\uae30\ub85d (Record)<\/th>\n<th scope=\"col\">Decision supported<\/th>\n<th scope=\"col\">Still required<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Containment screen<\/td>\n<td>200 checked; 6 suspect; 194 condition-clear<\/td>\n<td>Control the named suspect population<\/td>\n<td>Individual disposition and other acceptance<\/td>\n<\/tr>\n<tr>\n<td>Cause verification<\/td>\n<td>Selection and comparison mechanisms evidenced<\/td>\n<td>Choose targeted permanent actions<\/td>\n<td>Implemented action verification<\/td>\n<\/tr>\n<tr>\n<td>Controlled challenge<\/td>\n<td>Correct accepted; mismatch blocked<\/td>\n<td>Verify intended revised behavior<\/td>\n<td>Defined production effectiveness evidence<\/td>\n<\/tr>\n<tr>\n<td>Exit review<\/td>\n<td>Predetermined criteria and approvals<\/td>\n<td>Authorize containment release<\/td>\n<td>Ongoing normal control and recurrence response<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The example deliberately assigns no universal number of follow-up lots or days. Define the effectiveness window using risk, production opportunity and the mechanism involved. Ten units produced under one unchanged condition may provide less relevant evidence than a smaller, deliberately varied verification exercise followed by an appropriate production review.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"K23-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/2c1820cd1a8c3a28-8d-containment-to-effectiveness.svg\" alt=\"Fictional issue progresses from containment through verified causes and changed controls to effectiveness-based closure.\" width=\"1200\" height=\"675\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. A fictional 200-unit screen finds six suspects and 194 with no observed named discrepancy. Screening controls the reported condition; it does not establish removal of its cause or a WEHO defect rate. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/2c1820cd1a8c3a28-8d-containment-to-effectiveness.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>Zero observations in a follow-up population do not prove zero future risk. Report the number of relevant opportunities, the inspection method and any limitations. If the action&#39;s intended effect is to prevent a selection error, include evidence that the critical selection conditions actually occurred during verification rather than relying only on calendar time.<\/p>\n<h2 id=\"make-closure-criteria-visible-before-execution\"><span class=\"ez-toc-section\" id=\"Make_closure_criteria_visible_before_execution\"><\/span>Make closure criteria visible before execution<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A closure plan should state who approves the action, which documents or software change, how effectiveness is measured and when containment can end. Keep implementation completion separate from effectiveness completion. An installed control may still need evidence that it operates correctly across the intended product variants and actual workflow.<\/p>\n<p><a href=\"https:\/\/asq.org\/-\/media\/public\/wqm\/ASQ-WQM26-01_EightDisciplines-8D.pdf\" target=\"_blank\" rel=\"noopener\">ASQ&#39;s 8D reference sheet<\/a> identifies the sequence through implementation, validation and prevention of recurrence. Use the report to connect those stages, not merely to collect signatures. Customer-specific timing and approval obligations must come from the applicable agreement, not from this general article.<\/p>\n<p>An effectiveness check should also watch for unintended consequences. A new identification interlock could block the wrong legitimate variant, route records incorrectly or encourage an uncontrolled bypass when production is busy. Retain legitimate accepted-state and rejected-state evidence together, with a defined process for handling exceptions.<\/p>\n<p>\uadf8\ub9cc\ud07c <a href=\"https:\/\/www.wehopower.com\/ko\/news\/din-rail-power-supply-first-article-approval-checklist\/\">WEHO first-article approval checklist<\/a> provides a related product-record framework. An 8D closure record adds verified problem mechanisms and evidence that the corrective action addresses them. A revised first-article record may be needed, but it does not automatically close every affected lot or complaint.<\/p>\n<h2 id=\"execute-an-evidence-based-closure-review\"><span class=\"ez-toc-section\" id=\"Execute_an_evidence-based_closure_review\"><\/span>Execute an evidence-based closure review<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Bound the issue.<\/strong> Record the observed requirement failure, affected identities and known locations. Verify the population against available traceability and retain unresolved scope limitations.<\/li>\n<li><strong>Control the flow.<\/strong> Approve containment instructions, screening evidence and dispositions. Record quantities and unit references; verify that suspect material cannot enter accepted stock through an ordinary movement.<\/li>\n<li><strong>Verify the causes.<\/strong> Test occurrence and escape explanations against evidence. Record the reasoning and alternative hypotheses; verify that the selected actions address the supported mechanisms.<\/li>\n<li><strong>Validate the change.<\/strong> Confirm installation, document revisions and challenge outcomes before normal release. Record acceptance and rejection paths; verify that the action does not create an uncontrolled exception route.<\/li>\n<li><strong>Close against exit criteria.<\/strong> Review the predetermined effectiveness evidence and affected material dispositions. Record responsible approvals; verify that containment release, issue closure and ongoing monitoring are separately stated.<\/li>\n<\/ol>\n<p>A buyer-facing summary can protect confidential process details while still providing the problem scope, action rationale, implementation evidence and effectiveness conclusion. Agree what supporting records may be reviewed and how confidential attachments are controlled. A polished report should not conceal unresolved causes or open material dispositions.<\/p>\n<h2 id=\"prepare-a-corrective-action-evidence-enquiry\"><span class=\"ez-toc-section\" id=\"Prepare_a_corrective-action_evidence_enquiry\"><\/span>Prepare a corrective-action evidence enquiry<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Send WEHO the exact <a href=\"https:\/\/www.wehopower.com\/ko\/product\/wholesale-60w-single-output-din-rail-power-power-supply\/\">MDR-60-12 enquiry identity<\/a>, the applicable requirement, observed evidence and traceable unit or lot references. Distinguish an actual complaint from a prospective supplier-quality requirement. Agree response timing, containment scope and closure evidence with the responsible parties; no standard WEHO 8D deadline or incident is implied here.<\/p>\n<h2 id=\"frequently-asked-questions\"><span class=\"ez-toc-section\" id=\"Frequently_asked_questions\"><\/span>Frequently asked questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"does-sorting-the-suspect-lot-count-as-a-permanent-correction\"><span class=\"ez-toc-section\" id=\"Does_sorting_the_suspect_lot_count_as_a_permanent_correction\"><\/span>Does sorting the suspect lot count as a permanent correction?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Sorting can support containment and individual dispositions for the named condition. A permanent correction must address a verified cause and have appropriate implementation and effectiveness evidence.<\/p>\n<h3 id=\"must-an-8d-investigate-the-escape-cause-separately\"><span class=\"ez-toc-section\" id=\"Must_an_8D_investigate_the_escape_cause_separately\"><\/span>Must an 8D investigate the escape cause separately?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes, when the existing control allowed the reported condition to reach the next stage. The occurrence mechanism and the missed-detection mechanism may need different actions and verification.<\/p>\n<h3 id=\"can-containment-end-as-soon-as-an-action-is-installed\"><span class=\"ez-toc-section\" id=\"Can_containment_end_as_soon_as_an_action_is_installed\"><\/span>Can containment end as soon as an action is installed?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Not automatically. Containment release should follow the agreed exit criteria and responsible approval. Implementation alone may not provide the required effectiveness evidence or resolve suspect material.<\/p>\n<h3 id=\"does-zero-recurrence-over-a-few-lots-prove-zero-risk\"><span class=\"ez-toc-section\" id=\"Does_zero_recurrence_over_a_few_lots_prove_zero_risk\"><\/span>Does zero recurrence over a few lots prove zero risk?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Report the observed population, relevant opportunities and inspection limits. Absence of an observed recurrence supports a bounded conclusion rather than a guarantee about every future product.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Separate supplier containment from permanent corrective action, verify occurrence and escape causes, and enquire about WEHO MDR-60-12 quality evidence.<\/p>","protected":false},"author":2,"featured_media":22248,"parent":0,"menu_order":9,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-24734","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/news\/24734","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/comments?post=24734"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/news\/24734\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/media\/22248"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/media?parent=24734"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/news_category?post=24734"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}