{"id":4883,"date":"2023-04-11T08:04:19","date_gmt":"2023-04-11T08:04:19","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=product&#038;p=4883"},"modified":"2026-11-13T16:27:17","modified_gmt":"2026-11-13T08:27:17","slug":"60w-ultra-slim-step-shape-din-rail-power-supply-hdr-60","status":"publish","type":"product","link":"https:\/\/www.wehopower.com\/ko\/product\/60w-ultra-slim-step-shape-din-rail-power-supply-hdr-60\/","title":{"rendered":"AC-DC DIN \ub808\uc77c \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58 60W 5V 12V 24V 48V \uc6b8\ud2b8\ub77c \uc2ac\ub9bc \uc2a4\ud15d \ubaa8\uc591 DIN \ub808\uc77c HDR-60"},"content":{"rendered":"<p>&nbsp;<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"20%\">\ubaa8\ub378<\/td>\n<td width=\"20%\">HDR-60-5<\/td>\n<td width=\"20%\">HDR-60-12<\/td>\n<td width=\"20%\">HDR-60-24<\/td>\n<td width=\"20%\">HDR-60-48<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">DC output voltage, current<\/td>\n<td width=\"20%\">5V 0\uff5e6.5A<\/td>\n<td width=\"20%\">12V 0\uff5e4.5A<\/td>\n<td width=\"20%\">24V 0\uff5e2.5A<\/td>\n<td width=\"20%\">48V 0\uff5e1.25A<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\ud30c\ub3c4\uc640 \uc18c\uc74c<\/td>\n<td width=\"20%\">80mVp-p<\/td>\n<td width=\"20%\">120mVp-p<\/td>\n<td width=\"20%\">150mVp-p<\/td>\n<td width=\"20%\">240mVp-p<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\uc785\uad6c \uc640\uc774\uc5b4 \uc548\uc815\uc131<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\ubd80\ud558 \uc548\uc815\uc131<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<td width=\"20%\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\ub2a5\ub960<\/td>\n<td width=\"20%\">82%<\/td>\n<td width=\"20%\">85%<\/td>\n<td width=\"20%\">88%<\/td>\n<td width=\"20%\">88%<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">DC \uc804\uc555\uc758 \uc870\uc815 \uac00\ub2a5 \ubc94\uc704<\/td>\n<td width=\"20%\">\u00b110%<\/td>\n<td width=\"20%\">\u00b110%<\/td>\n<td width=\"20%\">\u00b110%<\/td>\n<td width=\"20%\">\u00b110%<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\uc785\ub825 \uc804\uc555 \ubc94\uc704<\/td>\n<td colspan=\"4\" width=\"80%\">85\uff5e264VAC\/120\uff5e370VDC; 47\uff5e63Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\ucda9\uaca9 \uc804\ub958<\/td>\n<td colspan=\"4\" width=\"80%\">Cold start current: 30A\/115VAC; 60A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\uacfc\ubd80\ud558 \ubcf4\ud638<\/td>\n<td colspan=\"4\" width=\"80%\">105%\uff5e150% cut off the output, automatic recovery<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\uacfc\uc804\uc555 \ubcf4\ud638<\/td>\n<td colspan=\"4\" width=\"80%\">115%\uff5e140% rated output power. Protection type: Hiccups mode, recovers automatically after fault condition is removed<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\uc124\uc815, \uc0c1\uc2b9, \uc720\uc9c0 \uc2dc\uac04<\/td>\n<td colspan=\"4\" width=\"80%\">1500ms, 80ms\/230VAC; 1500ms, 80ms\/115VAC (at full load)<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\ub0b4\uc804\uc555<\/td>\n<td colspan=\"4\" width=\"80%\">I\/P-O\/P: 1.5kV; I\/P-FG: 1.5kV; O\/P-FG: 0.5kV; 1 minute<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\uc808\uc5f0 \uc800\ud56d<\/td>\n<td colspan=\"4\" width=\"80%\">I\/P-O\/P, I\/P-FG, O\/P-FG: 100M\u03a9 \/ 500VDC \/ 25\u2103 \/ 70%RH<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\uc791\ub3d9 \uc628\ub3c4<\/td>\n<td colspan=\"4\" width=\"80%\">-20\u2103\uff5e+70\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\ucc28\uc6d0<\/td>\n<td colspan=\"4\" width=\"80%\">52.5\u00d790\u00d754.5mm<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">\ubb34\uac8c<\/td>\n<td colspan=\"4\" width=\"80%\">0.19kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why choose HDR-60?<\/h2>\n<h3>Defined mechanical envelope<\/h3>\n<p>The stated body dimensions are 52.5\u00d790\u00d754.5mm. Use these dimensions to allocate panel space, then check the complete drawing, terminal access and nearby equipment.<\/p>\n<h3>Distinct single-output versions<\/h3>\n<p>The listed versions are HDR-60-5, HDR-60-12, HDR-60-24, HDR-60-48. Each is a single-output model, not a simultaneous multi-voltage supply. Match the selected version to the equipment input.<\/p>\n<h3>Documented input coverage<\/h3>\n<p>The specified input ranges are 85\u2013264VAC and 120\u2013370VDC, with an AC frequency range of 47\u201363Hz. Confirm the actual source, wiring requirements and supplied revision.<\/p>\n<h3>Defined overload recovery<\/h3>\n<p>Overload protection is listed at 105%\uff5e150% with output cut-off and automatic recovery. Coordinate the supply and downstream load so a fault response is not treated as normal continuous operation.<\/p>\n<h2>60W \uc6b8\ud2b8\ub77c \uc2ac\ub9bc \uc2a4\ud15d\ud615 DIN \ub808\uc77c \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58\uc758 \ud2b9\uc9d5<\/h2>\n<h3>Model-specific output information<\/h3>\n<p>HDR-60-5: 5V 0\uff5e6.5A; HDR-60-12: 12V 0\uff5e4.5A; HDR-60-24: 24V 0\uff5e2.5A; HDR-60-48: 48V 0\uff5e1.25A. Keep each current range with its stated model; the family designation does not establish one continuous-power rating for every output option.<\/p>\n<h3>Regulation and adjustment<\/h3>\n<p>Line regulation and load regulation are each listed as \u00b11%. The DC voltage adjustment range is \u00b110%; confirm the connected electronics input limits before adjusting the setting.<\/p>\n<h3>Noise and efficiency data for selection<\/h3>\n<p>Ripple\/noise: HDR-60-5: 80mVp-p; HDR-60-12: 120mVp-p; HDR-60-24: 150mVp-p; HDR-60-48: 240mVp-p. Efficiency: HDR-60-5: 82%; HDR-60-12: 85%; HDR-60-24: 88%; HDR-60-48: 88%. Use the selected model figures in the load noise and power-budget assessment.<\/p>\n<h3>Model-specific terminal information<\/h3>\n<p>Pins 1 and 2: -V; pins 3 and 4: +V; pin 5: AC\/L; pin 6: AC\/N. The drawing specifies TS35\/7.5 or TS35\/15 DIN rails. Follow the complete drawing and the installation electrical-safety requirements.<\/p>\n<p style=\"text-align: center;\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-4885 size-full\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-60W-size.jpg\" alt=\"HDR-60W size\" width=\"2046\" height=\"623\" title=\"\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-60W-size.jpg 2046w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-60W-size-300x91.jpg 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-60W-size-1024x312.jpg 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-60W-size-768x234.jpg 768w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-60W-size-1536x468.jpg 1536w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/04\/HDR-60W-size-1568x477.jpg 1568w\" sizes=\"(max-width: 2046px) 100vw, 2046px\" \/><\/p>\n<h2>Typical service conditions<\/h2>\n<h3>Panel space and mechanical fit<\/h3>\n<p>Plan around the 52.5\u00d790\u00d754.5mm body and 0.19kg stated weight. The drawing specifies TS35\/7.5 or TS35\/15 DIN rails. Allow for wiring and the surrounding equipment; the body dimensions are not a universal clearance specification.<\/p>\n<h3>Input and terminal checks<\/h3>\n<p>Check the actual supply against 85\u2013264VAC or 120\u2013370VDC and the 47\u201363Hz AC range. Pins 1 and 2: -V; pins 3 and 4: +V; pin 5: AC\/L; pin 6: AC\/N. Confirm DC-input wiring for the selected revision rather than assuming AC labels alone define every DC installation.<\/p>\n<h3>Temperature and load planning<\/h3>\n<p>The working-temperature range is -20\u00b0C to +70\u00b0C. Assess the real enclosure, airflow and selected output load; the stated temperature range alone does not establish full output at every ambient temperature.<\/p>\n<h3>Start-up and fault coordination<\/h3>\n<p>Timing information is listed as 1500ms, 80ms\/230VAC; 1500ms, 80ms\/115VAC (at full load). Cold-start current is 30A\/115VAC; 60A\/230VAC. Keep these figures with their stated input conditions when coordinating upstream protection and downstream start-up.<\/p>\n<h2>Application guidance<\/h2>\n<p>These are potential integration roles, not customer-installation claims. Match the selected voltage, steady-state current, start-up demand and environment before selection.<\/p>\n<h3>Access-control electronics<\/h3>\n<p>Use a voltage-compatible HDR-60 version for reader, controller or interface electronics inside a protected access-control panel. Assess door strikes, motors and pulsed loads separately; a matching nominal voltage alone does not establish suitability.<\/p>\n<h3>Process sensing and monitoring<\/h3>\n<p>Provide local DC power to compatible sensor interfaces, monitoring modules or indication electronics with the selected HDR-60 voltage. Check steady-state and start-up demand and compare ripple\/noise with the measurement-system requirements.<\/p>\n<h3>Building-automation interfaces<\/h3>\n<p>Supply compatible zone-controller or building-management interface electronics in a protected panel. Check the HDR-60 mechanical envelope, panel temperature and load input limits; the supply alone does not establish outdoor or system-level approval.<\/p>\n<h3>Industrial communications equipment<\/h3>\n<p>Power compatible gateways, serial-interface modules or local communications electronics that accept the selected HDR-60 DC input. Verify the whole load budget and start-up conditions; this selection does not add PoE, backup or UPS functions.<\/p>\n<h2>HDR-60 technical FAQs<\/h2>\n<h3>Which DC output models are listed for HDR-60?<\/h3>\n<p>The listed models are HDR-60-5, HDR-60-12, HDR-60-24, HDR-60-48, with nominal outputs of 5V, 12V, 24V, 48V respectively. Each is a single-output version.<\/p>\n<h3>What current ratings are listed for HDR-60?<\/h3>\n<p>HDR-60-5: 5V 0\uff5e6.5A; HDR-60-12: 12V 0\uff5e4.5A; HDR-60-24: 24V 0\uff5e2.5A; HDR-60-48: 48V 0\uff5e1.25A. Keep each current range with its exact output model and assess the actual load and operating conditions.<\/p>\n<h3>What input-voltage and frequency ranges are specified?<\/h3>\n<p>The input-voltage ranges are 85\u2013264VAC and 120\u2013370VDC. The AC frequency range is 47\u201363Hz. Check the selected unit and installation requirements before connection.<\/p>\n<h3>What line-regulation and load-regulation figures are listed?<\/h3>\n<p>Line regulation and load regulation are each listed as \u00b11% for every output version in this family.<\/p>\n<h3>What DC voltage adjustment range is listed?<\/h3>\n<p>The listed DC voltage adjustment range is \u00b110% for each version. Verify the connected equipment input limits before changing the setting.<\/p>\n<h3>What ripple\/noise values are listed for HDR-60?<\/h3>\n<p>HDR-60-5: 80mVp-p; HDR-60-12: 120mVp-p; HDR-60-24: 150mVp-p; HDR-60-48: 240mVp-p. Confirm any application-specific measurement conditions separately.<\/p>\n<h3>What efficiency values are listed for HDR-60?<\/h3>\n<p>HDR-60-5: 82%; HDR-60-12: 85%; HDR-60-24: 88%; HDR-60-48: 88%. Use the figure for the selected voltage version.<\/p>\n<h3>What cold-start current is specified?<\/h3>\n<p>The listed cold-start current is 30A\/115VAC; 60A\/230VAC. Keep each value tied to its stated AC input when assessing upstream protection.<\/p>\n<h3>How is overload recovery specified?<\/h3>\n<p>The overload range is 105%\uff5e150%, with output cut-off and automatic recovery. Do not treat the protection threshold as a normal continuous operating rating.<\/p>\n<h3>What timing information is provided?<\/h3>\n<p>The timing row lists 1500ms, 80ms\/230VAC; 1500ms, 80ms\/115VAC (at full load). A separate third hold-up-time value is not printed in that row.<\/p>\n<h3>What working-temperature range and dimensions are stated for HDR-60?<\/h3>\n<p>The stated working-temperature range is -20\u00b0C to +70\u00b0C. Body dimensions are 52.5\u00d790\u00d754.5mm and weight is 0.19kg. Verify thermal performance with the actual load and enclosure rather than assuming full output at every temperature.<\/p>\n<h3>Which terminal assignments are shown for HDR-60?<\/h3>\n<p>Pins 1 and 2: -V; pins 3 and 4: +V; pin 5: AC\/L; pin 6: AC\/N. The drawing specifies TS35\/7.5 or TS35\/15 DIN rails. Use the complete drawing and applicable installation instructions for final integration.<\/p>","protected":false},"excerpt":{"rendered":"<p>HDR-60 is a reliable switching power supply with high-quality material, durable, and safe to use.<\/p>","protected":false},"author":1,"featured_media":21076,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[45,80],"product_categories_new":[116],"class_list":["post-4883","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-din-rail-power-supply","product_category-hdr-series-din-rail-power-supply","product_categories_new-hdr-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/product\/4883","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/comments?post=4883"}],"version-history":[{"count":4,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/product\/4883\/revisions"}],"predecessor-version":[{"id":21906,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/product\/4883\/revisions\/21906"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/media\/21076"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/media?parent=4883"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/product_category?post=4883"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/www.wehopower.com\/ko\/wp-json\/wp\/v2\/product_categories_new?post=4883"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}