Verify the input
Check 300–450 V AC at 47–63 Hz / 420–635 V DC at the installation point.
380 VAC input version of the LRS-250 platform (300–450 V AC, 47–63 Hz / 420–635 V DC). Choose the DC output voltage that matches your load. Output versions are adjustable ±10%.
| Parameter | LRH-250-5 | LRH-250-12 | LRH-250-15 | LRH-250-24 | LRH-250-48 |
|---|---|---|---|---|---|
| DC output voltage and current | 5 V · 0–50 A | 12 V · 0–20 A | 15 V · 0–16 A | 24 V · 0–10 A | 48 V · 0–5 A |
| Zakres napięcia wejściowego | 300–450 V AC, 47–63 Hz / 420–635 V DC | ||||
| Wymiary | 215 × 115 × 30 mm | ||||
| Efektywność | 85.5% | 85.5% | 86% | 88% | 89% |
| Temperatura pracy | −20 to +70 °C; full-load operation across this range is not specified. | ||||
| Ripple & noise | 150 mVp-p | 150 mVp-p | 150 mVp-p | 150 mVp-p | 200 mVp-p |
| Regulacja linii | ±0,5% | ||||
| Regulacja obciążenia | ±0,5% | ||||
| Regulacja napięcia wyjściowego | ±10% | ||||
| Inrush current | Consult WEHO for 380 V AC test report | ||||
| Zabezpieczenie przed przeciążeniem | 110–150%: output cuts off and recovers automatically. | ||||
| Inna ochrona | Overcurrent and short-circuit protection. | ||||
| Timing (setup / rise / hold-up) | Consult WEHO for 380 V AC test report | ||||
| Wytrzymuje napięcie | Input–output 1.5 kV; input–frame 1.5 kV; output–frame 0.5 kV, 1 minute. | ||||
| Rezystancja izolacji | 100 MΩ at 500 V DC, 25 °C and 70% RH (input–output, input–frame and output–frame). | ||||
| Waga | 0.66 kg | ||||
| Uszczelka | 37.5×25×26CM/20PCS/13kg | ||||
| Wyjście | Current | Efektywność | Marszczyć (mVp-p) |
|---|---|---|---|
| 5 V | 0–50 A | 85.5% | 150 |
| 12 V | 0–20 A | 85.5% | 150 |
| 15 V | 0–16 A | 86% | 150 |
| 24 V | 0–10 A | 88% | 150 |
| 48 V | 0–5 A | 89% | 200 |
| Zakres napięcia wejściowego | 300–450 V AC, 47–63 Hz / 420–635 V DC |
|---|---|
| Wymiary | 215 × 115 × 30 mm |
| Temperatura pracy | −20 to +70 °C; full-load operation across this range is not specified. |
| Regulacja linii | ±0,5% |
| Regulacja obciążenia | ±0,5% |
| Regulacja napięcia wyjściowego | ±10% |
| Inrush current | Consult WEHO for 380 V AC test report |
| Zabezpieczenie przed przeciążeniem | 110–150%: output cuts off and recovers automatically. |
| Inna ochrona | Overcurrent and short-circuit protection. |
| Timing (setup / rise / hold-up) | Consult WEHO for 380 V AC test report |
| Wytrzymuje napięcie | Input–output 1.5 kV; input–frame 1.5 kV; output–frame 0.5 kV, 1 minute. |
| Rezystancja izolacji | 100 MΩ at 500 V DC, 25 °C and 70% RH (input–output, input–frame and output–frame). |
| Waga | 0.66 kg |
| Uszczelka | 37.5×25×26CM/20PCS/13kg |
215 × 115 × 30 mm (L × W × H)
Drawing dimensions are in millimetres. Verify terminal markings on the unit before installation. Reference body width: 115 mm; reference width across mounting ears: 135 mm.
The operating range is −20 to +70 °C. A load-versus-temperature curve for this model is not supplied here. Confirm the permissible load at your actual cabinet temperature.
For an auxiliary control rack, compare the LRH-250-24 version (24 V · 0–10 A) with the total DC demand, including start-up. The 215 × 115 × 30 mm figure is the enclosure size, not the full service clearance.
| Funkcja | What to check |
|---|---|
| Output trim | Use the ±10% adjustment to fine-tune the rail within the load’s voltage limits. |
| Low-profile case | Allow space beyond the housing for airflow, wiring bends and access to the terminals. |
| Overload recovery | The output cuts off during overload and recovers automatically. Check how the equipment restarts. |
Check 300–450 V AC at 47–63 Hz / 420–635 V DC at the installation point.
Allow for the 215 × 115 × 30 mm enclosure, terminal access and cable bends.
Check the temperature near the supply during the longest duty cycle.
Assess what the connected equipment does when DC power returns.
Size the supply for the auxiliary electronics, not for the whole machine.
The HMI screen and tactile pushbuttons are examples of low-voltage loads to check when sizing a 380 V AC auxiliary supply for an operator station. The spindle drive is a separate load.
Size the 380 V AC-input auxiliary supply for safety light curtains, optical sensors and I/O modules—not for the robotic arm servo drives.
Account separately for the machine-vision camera, coaxial ring light and linear-stage controller loads when sizing the 380 V AC auxiliary supply.
AI-generated application illustrations for selection planning; not photographs of verified installations.
Each voltage is a separate version. 5 V, 12 V, 15 V, 24 V and 48 V are listed.
300–450 V AC, 47–63 Hz / 420–635 V DC
No full-load limit at that temperature is established here. Ask for the permitted load in your mounting conditions.
Include LRH-250, desired output, continuous and start-up current, quantity and destination.
Use the theme inquiry form on this product page. Selected model: LRH-250-5LRH-250-12LRH-250-15LRH-250-24LRH-250-48.









Wzmocnij swój biznes dzięki wysokiej jakości produktom zasilającym WEHO.
Zapytaj eksperta