WEHO SP-9000 Series: 9000W Intelligent Programmable DC Power Module with Advanced Modbus Telemetry
The WEHO SP-9000 is an elite, high-capacity switching power supply engineered to deliver an immense 9000W of precise DC power. Operating at peak 100% capacity on 195-265VAC inputs (and 50% capacity on 95-190VAC), it provides a comprehensive lineup of DC outputs from 24V up to 220V, boasting a staggering maximum current of 337.5A (on the 24V model). Achieving up to 93% peak energy efficiency, this module is built for total automated system control. It features ultra-wide output adjustability, native RS485 Modbus communication, and supports highly customizable hardware interfaces including a 12V/0.5A auxiliary supply and dry-contact alarm signals. The rugged 432 x 179 x 242 mm enclosure weighs 12.5 kg, delivering exceptional power density for heavy industry.
- Opis
Streszczenie
Single output: Power 9000W
Input voltage: 95-190VAC(output current 50%)195-265VAC(output current 100%)
Differentiated Advantages
The SP-9000 separates itself from conventional high-wattage power supplies through its highly customizable fault-logic and deep integration capabilities:
Programmable Surge Tolerance (5-Second Delay): Unlike standard industrial units that instantly shut down during current spikes, the SP-9000 features a user-programmable over-current logic. Operators can set a specific over-current threshold with a 5-second delay. This uniquely allows the system to absorb massive startup surges from heavy inductive motors or capacitive loads without triggering a disruptive system-wide reset.
Absolute Zero-to-Peak Tuning: It breaks the mold of static converters by offering extreme linear adjustability. Both output voltage and constant current can be meticulously dialed in from absolute zero up to their maximum over-ratings (e.g., 0-242V continuous tuning on the 220V model). This provides the surgical precision required for highly sensitive electrochemical processing, EV battery formation, and rigorous R&D stress testing.
Customizable Industrial Telemetry: Designed for seamless SCADA and PLC ecosystem integration, it pairs its RS485 Modbus protocol with customizable hardware feedback. With bespoke options for dry-contact “Power Good” alarm signals (≤36V, 0.1A) and high-level remote switching, it allows facility engineers to monitor power health in real-time, drastically reducing the need for expensive third-party relays and secondary wiring in OEM control cabinets.
Specyfikacja ogólna
| Model | SP-9000-24 | SP-9000-30 | SP-9000-36 | SP-9000-48 | SP-9000-60 | SP-9000-110 | SP-9000-220 |
| Napięcie stałe | 24 V | 30 V | 36 V | 48 V | 60V | 110 V | 220 V |
| Prąd znamionowy | 337.5A | 270A | 225A | 168.8A | 135A | 73.6A | 36.8A |
| Aktualny zakres | 0-337.5A | 0-270A | 0-225A | 0-168.8A | 0-135A | 0-73.6A | 0-36.8A |
| Moc znamionowa | 9000W | ||||||
| Marszczyć | 500mV | 500mV | 500mV | 600mV | 600mV | 1000mV | 1500mV |
| Constant current optimum range | 12-24 V | 15-30 V | 18-36 V | 24-48 V | 30-60V | 55-110 V | 110-220 V |
| Rated voltage accuracy | ±1,0% | ||||||
| Regulacja linii | ±1,0% | ||||||
| Regulacja obciążenia | ±1,0% | ||||||
| Czas uruchamiania i narastania | 1500mS,700mS/230VAC (Fully loaded) | ||||||
| Zakres napięcia | 95-190VAC(Output Current 50%),195-265VAC(Output Curent 100%) | ||||||
| Zakres częstotliwości | 45 Hz-65 Hz | ||||||
| Współczynnik mocy | PF≥0.99/230VAC (Fully loaded) | ||||||
| Efficiency(MAX) | 0.9 | 0.9 | 0.915 | 0.92 | 0.92 | 0.925 | 0.93 |
| Prąd przemienny | <56A | ||||||
| Prąd upływowy | <3,0mA/240VAC | ||||||
| Zwarcie | When the constant current is entered and the voltage is lower than 10%of the rated voltage,the output is shut down and locked after 1 second,and recover after restarting. | ||||||
| Over current | The user can set the over-curent value to delay the oufout for 5 seconds and then shut down the output,and then resume after restarting. | ||||||
| Overpressure | Users can set the overvoltage value to shut down the output voltage,and restore after restart. | ||||||
| Nadmierna temperatura | Shut down the output,automatically recover or restart after the temperature drops. | ||||||
| Output voltage adjustment | 0-26,4 V | 0-33 V | 0-39,6 V | 0-52,8 V | 0-66V | 0-121 V | 0-242 V |
| Output constant current adjustment | 0-337.5A | 0-270A | 0-225A | 0-168.8A | 0-135A | 0-73.6A | 0-36.8A |
| 485 Communications | MODBUS Communication Protocol | ||||||
| Isolated auxiliary | 12V0.5A (Need customization) | ||||||
| Output remote switch | Default power on,high level power off (5V-12V)(Need customization) | ||||||
| Alarm signal output | Power Good Signal(Dry Contact≤36V,0.1A) (Need customization) | ||||||
| Temperatura robocza | -20-+60 ℃ | ||||||
| Wilgotność robocza | -20-90%RH No condensation | ||||||
| Temperatura i wilgotność przechowywania | -40-+85℃,10-95%RHNo condensation | ||||||
| Odporność na wibracje | 110-500Hz,2G10 Min/cycle, X,Y,Z60 Min | ||||||
| Insulaion resistance | 输入输出:100Mhms/500VDC/25°C/70%RH Input to Output:100Mhms/500VDC/25°C/70%RH |
||||||
| Odporność na ciśnienie | I/P-O/P:2KVAC IP-FG:2KVAC O/P-FG:0.5KVAC | ||||||
| Size | 432×179×242mm | ||||||
| Net weight | 12.5 kg | ||||||