{"id":20534,"date":"2026-11-01T10:41:34","date_gmt":"2026-11-01T02:41:34","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/hlg150-reach-svhc-declaration-scope\/"},"modified":"2026-11-01T10:41:34","modified_gmt":"2026-11-01T02:41:34","slug":"hlg150-reach-svhc-declaration-scope","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/pl\/news\/hlg150-reach-svhc-declaration-scope\/","title":{"rendered":"REACH and SVHC Declarations for an LED Driver: Control the Product and Revision Scope"},"content":{"rendered":"<div class=\"weho-blog-content\">\n<p><strong>Accept a REACH\/SVHC declaration only when its product scope, substance-list date and supporting material evidence cover the driver you are buying.<\/strong> A supplier logo, an electrical specification or a document headed \u201cREACH compliant\u201d does not settle those questions.<\/p>\n<p>For an LED luminaire procurement team, the decision is whether the evidence can support the project\u2019s material-compliance file. This guide uses <a href=\"https:\/\/www.wehopower.com\/pl\/product\/hlg-150-150w-12v-24v-36v-48v-waterproof-ip67-led-power-supply-with-pfc\/\">WEHO HLG-150-24<\/a> as an identifiable product example. It does not assert that a model-specific REACH declaration or test report has been supplied.<\/p>\n<nav class=\"toc\" aria-label=\"Article contents\">\n<p>In this article<\/p>\n<ol>\n<li><a href=\"#scope\">Start with the purchased article and revision<\/a><\/li>\n<li><a href=\"#legal-trigger\">Understand the declaration\u2019s specific claim<\/a><\/li>\n<li><a href=\"#evidence-record\">Build a scope record procurement can review<\/a><\/li>\n<li><a href=\"#example\">A cable change can make the evidence incomplete<\/a><\/li>\n<li><a href=\"#separate-documents\">Keep material evidence separate from electrical approvals<\/a><\/li>\n<li><a href=\"#release\">Make a documented disposition before the next delivery<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"scope\">\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Spis tre\u015bci<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Prze\u0142\u0105cznik Spisu Tre\u015bci\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">D\u017awignia kolankowa<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/pl\/news\/hlg150-reach-svhc-declaration-scope\/#Start_with_the_purchased_article_and_revision\" >Start with the purchased article and revision<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/pl\/news\/hlg150-reach-svhc-declaration-scope\/#Understand_the_declarations_specific_claim\" >Understand the declaration\u2019s specific claim<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/pl\/news\/hlg150-reach-svhc-declaration-scope\/#Build_a_scope_record_procurement_can_review\" >Build a scope record procurement can review<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/pl\/news\/hlg150-reach-svhc-declaration-scope\/#A_cable_change_can_make_the_evidence_incomplete\" >A cable change can make the evidence incomplete<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/pl\/news\/hlg150-reach-svhc-declaration-scope\/#Keep_material_evidence_separate_from_electrical_approvals\" >Keep material evidence separate from electrical approvals<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/pl\/news\/hlg150-reach-svhc-declaration-scope\/#Make_a_documented_disposition_before_the_next_delivery\" >Make a documented disposition before the next delivery<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/pl\/news\/hlg150-reach-svhc-declaration-scope\/#Use_the_project_record\" >Use the project record<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/pl\/news\/hlg150-reach-svhc-declaration-scope\/#Request_the_declaration_for_your_exact_LED_driver_order\" >Request the declaration for your exact LED driver order<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/pl\/news\/hlg150-reach-svhc-declaration-scope\/#Sources_and_further_reading\" >Sources and further reading<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Start_with_the_purchased_article_and_revision\"><\/span>Start with the purchased article and revision<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The HLG-150 product page lists a 24 V, 6.3 A version, while the official product photograph shows an HLG-150-24 label marked 24 V, 6.25 A and 150 W. Keep these source entries separate and confirm the controlled rating for the delivered revision. Record the full order code, label photograph, manufacturer identity and delivered revision. Add any customized leads, connectors or housing treatment to the purchase description. The electrical rating helps identify the item; it does not demonstrate the composition of its solder, coating or cables.<\/p>\n<p>Obtain a declaration that names the covered model or gives an unambiguous model list. A family statement may be usable when the supplier explains the shared construction and any exceptions. Do not silently extend a statement for one driver to a different voltage option or accessory kit.<\/p>\n<\/section>\n<section id=\"legal-trigger\">\n<h2><span class=\"ez-toc-section\" id=\"Understand_the_declarations_specific_claim\"><\/span>Understand the declaration\u2019s specific claim<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a href=\"https:\/\/echa.europa.eu\/regulations\/reach\/candidate-list-substances-in-articles\/communication-in-the-supply-chain\" target=\"_blank\" rel=\"noopener\">ECHA\u2019s supply-chain communication guidance<\/a> explains that Article 33 communication is triggered when an article contains a Candidate List substance above 0.1% by weight. Professional recipients must receive sufficient safe-use information, including at least the substance name. ECHA\u2019s <a href=\"https:\/\/echa.europa.eu\/documents\/10162\/2324906\/nutshell_guidance_articles2_en.pdf\" target=\"_blank\" rel=\"noopener\">guidance on substances in articles<\/a> also explains that the threshold applies to each article within a complex object, rather than automatically to the total weight of the assembled product.<\/p>\n<p>A declaration should therefore state what was assessed and what the conclusion means. Distinguish a Candidate List screening statement, information about a substance above the threshold, and claims addressing other REACH obligations. A document addressing one question is not automatically a complete answer to every material-compliance requirement in the contract.<\/p>\n<\/section>\n<section id=\"evidence-record\">\n<h2><span class=\"ez-toc-section\" id=\"Build_a_scope_record_procurement_can_review\"><\/span>Build a scope record procurement can review<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Evidence field<\/th>\n<th scope=\"col\">Useful supplier answer<\/th>\n<th scope=\"col\">Reason to return the document<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Product coverage<\/th>\n<td>Exact HLG-150-24 code, relevant construction revision and listed accessories.<\/td>\n<td>Only a company name or a different product family.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Substance scope<\/th>\n<td>Dated Candidate List reference and stated assessment coverage.<\/td>\n<td>An undated \u201call substances\u201d sentence without a defined list.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Assessment basis<\/th>\n<td>Material declarations, supplier data or test-report identifiers tied to the relevant articles.<\/td>\n<td>A test result for an unidentified sample.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Exceptions and safe use<\/th>\n<td>Identified substances and applicable information, or a clearly bounded below-threshold conclusion.<\/td>\n<td>An unconditional conclusion with no scope or exceptions.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Change control<\/th>\n<td>Owner and process for notifying material or construction changes.<\/td>\n<td>No way to tell whether later deliveries remain covered.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure class=\"figure\" id=\"figure-diagram\"><picture><source media=\"(max-width: 600px)\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/decision-map-mobile-3.svg\" width=\"480\" height=\"1070\" type=\"image\/svg+xml\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/decision-map-3.svg\" alt=\"REACH and SVHC Declarations for an LED Driver: Control the Product and Revision Scope  title=\" width=\"1200\" height=\"740\" decoding=\"async\" reach and svhc declarations for an led driver: control the product revision scope title =\"\"><\/picture><figcaption>Review the declaration against the ordered driver. Decision sequence. No wiring diagram, dimensions, test results or product approval. <a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/decision-map-3.svg\">View original image<\/a><\/figcaption><\/figure>\n<\/section>\n<section id=\"example\">\n<h2><span class=\"ez-toc-section\" id=\"A_cable_change_can_make_the_evidence_incomplete\"><\/span>A cable change can make the evidence incomplete<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Illustrative procurement example:<\/strong> a luminaire maker orders an HLG-150-24 with an added cable connector. The declaration names the driver family, but its accessory list covers only the standard leads. The team has electrical information for the driver and a separate connector drawing, yet no material statement for the connector assembly.<\/p>\n<p>The correct disposition is to request the missing connector coverage and the supplier\u2019s explanation of the combined scope. It is not to declare the driver noncompliant, and it is not to treat the driver\u2019s weight as a way to dilute an unassessed small component. Record the connector code and revision so the follow-up can resolve a specific gap.<\/p>\n<p>If the supplier provides a later declaration, compare the model list and assessment basis as well as the signature date. A recently signed document can still reference an older screening list. Conversely, a material report\u2019s age alone does not identify which component or substance needs further assessment.<\/p>\n<\/section>\n<section id=\"separate-documents\">\n<h2><span class=\"ez-toc-section\" id=\"Keep_material_evidence_separate_from_electrical_approvals\"><\/span>Keep material evidence separate from electrical approvals<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Store the material declaration alongside the order specification and sample identity. Keep RoHS, electrical safety, electromagnetic compatibility and ingress-protection evidence in their appropriate records. One document can reference another, but a CE mark or a waterproof housing does not answer the SVHC scope question.<\/p>\n<p>For the HLG-150 order, use the same product identity and delivered revision across the material record, electrical specification and purchase documents. If different documents cover different revisions or accessory sets, ask the supplier to identify the applicable combination. Resolve each project requirement on its own evidence; do not use a material statement to approve electrical or mechanical suitability.<\/p>\n<\/section>\n<section id=\"release\">\n<h2><span class=\"ez-toc-section\" id=\"Make_a_documented_disposition_before_the_next_delivery\"><\/span>Make a documented disposition before the next delivery<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assign the record one of three practical states: covered for the specified purchase, additional information required, or a contract requirement not met. Give each open item an owner and a specific document request. Preserve earlier versions so a replacement statement does not erase what was relied upon for a previous delivery.<\/p>\n<p>Recheck the scope when the order code, material construction, source of an accessory or project requirement changes. Confirm which Candidate List update the next declaration addresses. Use the <a href=\"\/pl\/acceptance-record.html\/\">blank declaration-scope worksheet<\/a> to keep that decision repeatable without presenting an unverified statement as a WEHO product qualification.<\/p>\n<\/section>\n<section id=\"project-record\">\n<h2><span class=\"ez-toc-section\" id=\"Use_the_project_record\"><\/span>Use the project record<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a href=\"\/pl\/acceptance-record.html\/\">Open the blank LED driver REACH\/SVHC declaration scope record<\/a> to record your conditions, evidence and decisions. The worksheet contains no pre-approved result.<\/p>\n<\/section>\n<section class=\"cta\" id=\"project-review\">\n<h2><span class=\"ez-toc-section\" id=\"Request_the_declaration_for_your_exact_LED_driver_order\"><\/span>Request the declaration for your exact LED driver order<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Send WEHO the HLG-150-24 order configuration, destination-market requirements, accessory list and required document date. Request a declaration identifying the covered product revision, assessment scope and any applicable substance information.<\/p>\n<p><a href=\"https:\/\/www.wehopower.com\/pl\/contact\/\">Discuss the required product documentation<\/a><\/p>\n<\/section>\n<section class=\"sources\" id=\"sources\">\n<h2><span class=\"ez-toc-section\" id=\"Sources_and_further_reading\"><\/span>Sources and further reading<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><a href=\"https:\/\/www.wehopower.com\/pl\/product\/hlg-150-150w-12v-24v-36v-48v-waterproof-ip67-led-power-supply-with-pfc\/\">WEHO HLG-150 product information<\/a><\/li>\n<li><a href=\"https:\/\/echa.europa.eu\/regulations\/reach\/candidate-list-substances-in-articles\/communication-in-the-supply-chain\" target=\"_blank\" rel=\"noopener\">ECHA \u2014 Communication in the supply chain<\/a><\/li>\n<li><a href=\"https:\/\/echa.europa.eu\/documents\/10162\/2324906\/nutshell_guidance_articles2_en.pdf\" target=\"_blank\" rel=\"noopener\">ECHA \u2014 Guidance in a Nutshell on substances in articles, version 3.0<\/a><\/li>\n<\/ol>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Match the declaration to the purchased driver and material revision before accepting a general REACH statement.<\/p>","protected":false},"author":2,"featured_media":20513,"parent":0,"menu_order":64,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-20534","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news\/20534","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/comments?post=20534"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news\/20534\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/media\/20513"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/media?parent=20534"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news_category?post=20534"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}