{"id":21793,"date":"2026-11-12T16:05:21","date_gmt":"2026-11-12T08:05:21","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/power-supply-screw-intrusion-tolerance\/"},"modified":"2026-11-12T16:05:21","modified_gmt":"2026-11-12T08:05:21","slug":"power-supply-screw-intrusion-tolerance","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/","title":{"rendered":"Power Supply Mounting Screws: Calculate the Intrusion Limit"},"content":{"rendered":"<div class=\"weho-blog\">\n<div class=\"key-takeaways\">\n<strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Power supply screw selection must satisfy maximum intrusion and minimum engagement at the same time.<\/li>\n<li>Calculate the longest screw against the thinnest external stack; check the shortest screw against the thickest stack.<\/li>\n<li>Use the ordered model&#8217;s controlled mounting drawing to establish limits. An M3 thread callout alone is insufficient.<\/li>\n<li>The worked dimensions below are hypothetical assembly inputs, not approved WEHO screw lengths.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/pl\/product\/150w-ac-dc-switching-power-supply\/\" aria-label=\"LRS-150-12 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-150-12-application.webp\" alt=\"Power Supply Mounting Screws: Calculate the Intrusion Limit  title=\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" power supply mounting screws: calculate the intrusion limit title =\"\"><\/a><figcaption>AI-assisted application illustration. Disconnected WEHO LRS-150-12 on an assembly bench; no mounting approval or screw-penetration measurement is shown. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/application-source-3.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#why-a-screw-that-fits-can-still-fail-the-assembly-review\">Why a screw that fits can still fail the assembly review<\/a><\/li>\n<li><a href=\"#define-the-measurement-plane-before-calculating\">Define the measurement plane before calculating<\/a><\/li>\n<li><a href=\"#work-a-hypothetical-tolerance-stack\">Work a hypothetical tolerance stack<\/a><\/li>\n<li><a href=\"#release-the-fastening-system-not-one-catalog-number\">Release the fastening system, not one catalog number<\/a><\/li>\n<li><a href=\"#verify-the-assembly-before-freezing-the-bom\">Verify the assembly before freezing the BOM<\/a><\/li>\n<li><a href=\"#prepare-a-mechanical-question-for-weho\">Prepare a mechanical question for WEHO<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Frequently asked questions<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Spis tre\u015bci<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Prze\u0142\u0105cznik Spisu Tre\u015bci\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">D\u017awignia kolankowa<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Why_a_screw_that_fits_can_still_fail_the_assembly_review\" >Why a screw that fits can still fail the assembly review<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Define_the_measurement_plane_before_calculating\" >Define the measurement plane before calculating<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Separate_usable_thread_from_empty_space\" >Separate usable thread from empty space<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Work_a_hypothetical_tolerance_stack\" >Work a hypothetical tolerance stack<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Compare_changes_against_both_limits\" >Compare changes against both limits<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Add_omitted_geometry_explicitly\" >Add omitted geometry explicitly<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Release_the_fastening_system_not_one_catalog_number\" >Release the fastening system, not one catalog number<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Verify_the_assembly_before_freezing_the_BOM\" >Verify the assembly before freezing the BOM<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Prepare_a_mechanical_question_for_WEHO\" >Prepare a mechanical question for WEHO<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Frequently_asked_questions\" >Frequently asked questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Does_an_M3_marking_tell_me_the_allowed_screw_length\" >Does an M3 marking tell me the allowed screw length?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Can_adding_a_washer_make_an_overlong_screw_acceptable\" >Can adding a washer make an overlong screw acceptable?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Is_more_thread_engagement_always_better\" >Is more thread engagement always better?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-screw-intrusion-tolerance\/#Can_the_nominal_screw_calculation_replace_a_sample_inspection\" >Can the nominal screw calculation replace a sample inspection?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"why-a-screw-that-fits-can-still-fail-the-assembly-review\"><span class=\"ez-toc-section\" id=\"Why_a_screw_that_fits_can_still_fail_the_assembly_review\"><\/span>Why a screw that fits can still fail the assembly review<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A mounting screw can tighten normally yet project too far inside a power supply. A shorter replacement may avoid intrusion but leave inadequate thread engagement. The release decision therefore concerns a complete fastening stack, including dimensional tolerances and the chosen fixing face.<\/p>\n<p>For an OEM using the <a href=\"https:\/\/www.wehopower.com\/pl\/product\/150w-ac-dc-switching-power-supply\/\">LRS-150-12 mechanical product reference<\/a>, keep the ordered revision with its mounting drawing. This article develops the screw-length check; the separate <a href=\"https:\/\/www.wehopower.com\/pl\/news\/power-supply-mounting-drawing-oem-fabrication-review\/\">mounting drawing fabrication review<\/a> covers locating the holes and selecting their reference face.<\/p>\n<figure class=\"article-figure product\" data-asset=\"product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/pl\/product\/150w-ac-dc-switching-power-supply\/\" aria-label=\"LRS-150-12 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-150-12-product.webp\" alt=\"Power Supply Mounting Screws: Calculate the Intrusion Limit  title=\" width=\"800\" height=\"800\" decoding=\"async\" power supply mounting screws: calculate the intrusion limit title =\"\"><\/a><figcaption>Disconnected reference; no mounting approval or measured screw penetration. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/application-source-3.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"define-the-measurement-plane-before-calculating\"><span class=\"ez-toc-section\" id=\"Define_the_measurement_plane_before_calculating\"><\/span>Define the measurement plane before calculating<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Intrusion<\/strong> is the distance a screw extends beyond the power supply&#39;s external mounting surface. Screw length is measured from the bearing surface appropriate to its head style. A countersunk screw needs a different geometric interpretation from a screw whose head bears on a flat washer.<\/p>\n<p>Name the reference planes on the assembly drawing. Otherwise, one engineer may subtract the backplate while another also subtracts a chassis wall already included in the supplier&#39;s depth definition. Both calculations can look reasonable and still describe different distances.<\/p>\n<p>The public <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/10\/LRS-150-1.pdf\">WEHO LRS-150 specification<\/a> includes mechanical views and more than one M3 fixing callout. It does not justify transferring a depth from one face to another, nor treating a drawing annotation as a universal limit for every enclosure revision. Obtain an unambiguous interpretation for the actual mounting interface before production release.<\/p>\n<p>The general risk is established independently: <a href=\"https:\/\/configurable.meanwell.com\/productPre.aspx\" target=\"_blank\" rel=\"noopener\">MEAN WELL&#39;s installation precautions<\/a> warn that excessive mounting screw length can contact internal components. Those precautions explain the engineering concern; they do not specify a WEHO screw length or torque.<\/p>\n<h3 id=\"separate-usable-thread-from-empty-space\"><span class=\"ez-toc-section\" id=\"Separate_usable_thread_from_empty_space\"><\/span>Separate usable thread from empty space<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A maximum intrusion allowance and a minimum engagement requirement answer different questions. Empty clearance beyond a threaded boss may permit a screw tip to enter without providing additional thread engagement. Conversely, a blind thread may limit penetration before any nearby component does.<\/p>\n<p>Request the usable thread interval, allowable penetration, fixing-face definition and permitted fastener details together. Do not derive minimum engagement from thread diameter alone, or assume that the entire calculated projection is useful thread. Material, thread formation and loading affect the fastening decision.<\/p>\n<h2 id=\"work-a-hypothetical-tolerance-stack\"><span class=\"ez-toc-section\" id=\"Work_a_hypothetical_tolerance_stack\"><\/span>Work a hypothetical tolerance stack<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Consider a simplified assembly in which the screw head bears flat on the washer and the threaded interface begins exactly at the power supply mounting plane. This is a <strong>hypothetical example<\/strong> with no recess, standoff or unthreaded lead-in. Assume the assembly authority has specified at least 2.0 mm usable engagement and at most 4.0 mm intrusion for this example only.<\/p>\n<p>The proposed screw is 6.0 \u00b1 0.2 mm long, measured under its head. The backplate is 2.0 \u00b1 0.1 mm thick and the washer is 0.8 \u00b1 0.1 mm thick. The washer dimensions represent its assembled bearing thickness; a compressible washer would require its actual loaded range.<\/p>\n<p>For this simplified geometry, projection p equals screw length L minus external stack thickness t. The two limiting checks are:<\/p>\n<p class=\"equation\">p<sub>max<\/sub> = L<sub>max<\/sub> \u2212 t<sub>min<\/sub><\/p>\n<p class=\"equation\">p<sub>min<\/sub> = L<sub>min<\/sub> \u2212 t<sub>max<\/sub><\/p>\n<p>The thinnest stack is 1.9 + 0.7 = 2.6 mm. The thickest stack is 2.1 + 0.9 = 3.0 mm. Therefore maximum projection is 6.2 \u2212 2.6 = 3.6 mm, while minimum projection is 5.8 \u2212 3.0 = 2.8 mm.<\/p>\n<p>Both results fall within the assumed 2.0\u20134.0 mm window. The upper margin is 0.4 mm and the lower margin is 0.8 mm. These are dimensional margins in the example; they do not establish vibration retention, clamp force, electrical clearance or a production acceptance rule for LRS-150-12.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/mounting-screw-tolerance-window.svg\" alt=\"Power Supply Mounting Screws: Calculate the Intrusion Limit  title=\" width=\"1200\" height=\"900\" decoding=\"async\" power supply mounting screws: calculate the intrusion limit title =\"\"><\/div><figcaption>Conceptual Engineering Diagram. illustrative values and project source requirements apply. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/mounting-screw-tolerance-window.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<h3 id=\"compare-changes-against-both-limits\"><span class=\"ez-toc-section\" id=\"Compare_changes_against_both_limits\"><\/span>Compare changes against both limits<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The same assembly can fail after a seemingly minor purchasing substitution. An 8.0 \u00b1 0.2 mm screw gives 8.2 \u2212 2.6 = 5.6 mm maximum projection. A 4.0 \u00b1 0.2 mm screw gives 3.8 \u2212 3.0 = 0.8 mm minimum projection.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<caption>Hypothetical alternatives using the same 2.6\u20133.0 mm external stack<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Screw length<\/th>\n<th scope=\"col\">Projection range<\/th>\n<th scope=\"col\">Assumed requirement<\/th>\n<th scope=\"col\">Dimensional decision<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>4.0 \u00b1 0.2 mm<\/td>\n<td>0.8\u20131.6 mm<\/td>\n<td>2.0 mm minimum<\/td>\n<td>Insufficient engagement in this simplified geometry<\/td>\n<\/tr>\n<tr>\n<td>6.0 \u00b1 0.2 mm<\/td>\n<td>2.8\u20133.6 mm<\/td>\n<td>2.0\u20134.0 mm window<\/td>\n<td>Passes the stated dimensional checks only<\/td>\n<\/tr>\n<tr>\n<td>8.0 \u00b1 0.2 mm<\/td>\n<td>4.8\u20135.6 mm<\/td>\n<td>4.0 mm maximum<\/td>\n<td>Excessive intrusion<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>A nominal-only check would report 3.2 mm for the 6 mm screw and conceal the 0.4 mm upper margin. Worst-case arithmetic makes that exposure visible. It also helps purchasing identify which dimensions must remain controlled when a washer, bracket or screw supplier changes.<\/p>\n<h3 id=\"add-omitted-geometry-explicitly\"><span class=\"ez-toc-section\" id=\"Add_omitted_geometry_explicitly\"><\/span>Add omitted geometry explicitly<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If the first usable thread starts inside the mounting plane, subtract that setback when checking engagement. If a spacer separates the enclosure from the plate, add its loaded thickness to the external stack. Track these distances as signed dimensions with a small section sketch.<\/p>\n<p>Do not apply the simplified projection formula unchanged to a recessed or countersunk assembly. Update the actual bearing plane, thread interval and dimensional chain, then recompute the extremes. A section drawing is more useful than a photograph for resolving those interfaces.<\/p>\n<h2 id=\"release-the-fastening-system-not-one-catalog-number\"><span class=\"ez-toc-section\" id=\"Release_the_fastening_system_not_one_catalog_number\"><\/span>Release the fastening system, not one catalog number<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A screw-length calculation is only one part of the mounting record. The assembly also needs an approved fastener material, head form, washer arrangement, tightening procedure and retention method. Reaching a torque setting does not prove that a screw is clamping the stack rather than bottoming out.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<caption>Minimum evidence for an OEM fastening release<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Record<\/th>\n<th scope=\"col\">Owner or source<\/th>\n<th scope=\"col\">Check that closes the decision<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Mounting face and depth definition<\/td>\n<td>Applicable supplier drawing<\/td>\n<td>Reference planes and hole identifiers agree<\/td>\n<\/tr>\n<tr>\n<td>Length and stack tolerances<\/td>\n<td>Fastener and fabrication drawings<\/td>\n<td>Both worst-case projections satisfy the approved limits<\/td>\n<\/tr>\n<tr>\n<td>Usable thread and engagement<\/td>\n<td>Supplier interface requirements<\/td>\n<td>Actual overlap meets the specified engagement requirement<\/td>\n<\/tr>\n<tr>\n<td>Tightening and retention<\/td>\n<td>Approved assembly procedure<\/td>\n<td>Installed sample matches the documented method<\/td>\n<\/tr>\n<tr>\n<td>Service replacement parts<\/td>\n<td>Released BOM<\/td>\n<td>Maintenance substitutes preserve the complete stack<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"verify-the-assembly-before-freezing-the-bom\"><span class=\"ez-toc-section\" id=\"Verify_the_assembly_before_freezing_the_BOM\"><\/span>Verify the assembly before freezing the BOM<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Identify the interface.<\/strong> Record the exact model, ordered revision, fixing face and hole identifiers. Verify that the controlled drawing describes the supplied unit rather than a visually similar family member.<\/li>\n<li><strong>Build the dimensional chain.<\/strong> Record screw length, loaded stack thickness, recesses and usable thread coordinates. Verify the measurement planes on a section drawing before calculating.<\/li>\n<li><strong>Calculate both extremes.<\/strong> Record maximum intrusion and minimum usable engagement with their limiting combinations. Accept only against applicable documented limits; obtain missing limits before releasing the fastener.<\/li>\n<li><strong>Check an isolated sample assembly.<\/strong> Record the selected parts and inspection method under the equipment&#39;s energy-isolation procedure. Verify seating and absence of bottoming without opening or probing an energized supply.<\/li>\n<li><strong>Control substitutions.<\/strong> Record the complete stack in the BOM and service instructions. Recalculate whenever a change can alter bearing geometry, thread overlap or clamping conditions.<\/li>\n<\/ol>\n<h2 id=\"prepare-a-mechanical-question-for-weho\"><span class=\"ez-toc-section\" id=\"Prepare_a_mechanical_question_for_WEHO\"><\/span>Prepare a mechanical question for WEHO<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use the <a href=\"https:\/\/www.wehopower.com\/pl\/product\/150w-ac-dc-switching-power-supply\/\">LRS-150-12 mounting reference page<\/a> with your assembly section, proposed fastener and tolerance calculation. <a href=\"https:\/\/www.wehopower.com\/pl\/contact\/\">Send WEHO the model and fixing-face question<\/a> and ask for the applicable controlled drawing, intrusion interpretation and fastening requirements before approving production hardware.<\/p>\n<h2 id=\"frequently-asked-questions\"><span class=\"ez-toc-section\" id=\"Frequently_asked_questions\"><\/span>Frequently asked questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"does-an-m3-marking-tell-me-the-allowed-screw-length\"><span class=\"ez-toc-section\" id=\"Does_an_M3_marking_tell_me_the_allowed_screw_length\"><\/span>Does an M3 marking tell me the allowed screw length?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. M3 identifies a nominal thread size, while allowable intrusion and required engagement depend on the actual interface. Obtain the fixing-face limits and measurement definitions for the ordered revision.<\/p>\n<h3 id=\"can-adding-a-washer-make-an-overlong-screw-acceptable\"><span class=\"ez-toc-section\" id=\"Can_adding_a_washer_make_an_overlong_screw_acceptable\"><\/span>Can adding a washer make an overlong screw acceptable?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A washer can reduce projection, but it does not automatically make the fastening system acceptable. Recalculate with its assembled thickness and tolerances, then verify bearing, retention and the approved washer arrangement.<\/p>\n<h3 id=\"is-more-thread-engagement-always-better\"><span class=\"ez-toc-section\" id=\"Is_more_thread_engagement_always_better\"><\/span>Is more thread engagement always better?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Additional projection can exceed the permitted intrusion or reach a blind-hole bottom. Engagement must meet its documented minimum while penetration remains within the allowed envelope.<\/p>\n<h3 id=\"can-the-nominal-screw-calculation-replace-a-sample-inspection\"><span class=\"ez-toc-section\" id=\"Can_the_nominal_screw_calculation_replace_a_sample_inspection\"><\/span>Can the nominal screw calculation replace a sample inspection?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. The tolerance calculation and sample inspection address different errors. Arithmetic checks the specified dimensional extremes; inspection checks whether the actual parts, bearing surfaces and assembly method match that specification.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Check power supply screw intrusion with a tolerance stack, compare engagement limits, and send WEHO your mounting-face drawing before BOM release.<\/p>","protected":false},"author":2,"featured_media":21752,"parent":0,"menu_order":68,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-21793","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news\/21793","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/comments?post=21793"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news\/21793\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/media\/21752"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/media?parent=21793"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news_category?post=21793"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}