{"id":24010,"date":"2026-11-25T10:13:33","date_gmt":"2026-11-25T02:13:33","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/trigger-holdoff-event-capture-coverage\/"},"modified":"2026-11-25T10:13:33","modified_gmt":"2026-11-25T02:13:33","slug":"trigger-holdoff-event-capture-coverage","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/","title":{"rendered":"Trigger Holdoff: Verify Coverage of Repeated Power Events"},"content":{"rendered":"<div class=\"weho-blog\">\n<p>A scope&#39;s saved record count is not automatically the number of power events that occurred. Trigger holdoff, acquisition duration and rearming can exclude events before they become separate records, even when the displayed waveform looks stable.<\/p>\n<div class=\"key-takeaways\"><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Define whether the requirement concerns events, triggers or records.<\/li>\n<li>Read the actual instrument&#39;s holdoff timing semantics.<\/li>\n<li>Include acquisition and rearm behavior in the coverage check.<\/li>\n<li>Compare source-event timestamps with retained acquisition timestamps.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"K14-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/pl\/product\/rsp-350-ac-to-dc-power-supply-with-pfc\/\" aria-label=\"RSP-350-12 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/5e5602cf4fff356c-rsp-350-12-application.webp\" alt=\"RSP-350-12 product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" title=\"\"><\/a><figcaption>Application illustration of RSP-350-12 in an equipment setting; not a customer installation photo. Scene created with AI assistance. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/68798b971e108158-application-master.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#1-decide-what-the-event-count-must-prove\">1. Decide what the event count must prove<\/a><\/li>\n<li><a href=\"#2-distinguish-three-timing-boundaries\">2. Distinguish three timing boundaries<\/a><\/li>\n<li><a href=\"#3-recalculate-an-explicitly-assumed-holdoff-timeline\">3. Recalculate an explicitly assumed holdoff timeline<\/a><\/li>\n<li><a href=\"#4-segmented-memory-still-needs-a-coverage-check\">4. Segmented memory still needs a coverage check<\/a><\/li>\n<li><a href=\"#5-compare-independent-event-and-acquisition-timestamps\">5. Compare independent event and acquisition timestamps<\/a><\/li>\n<li><a href=\"#6-release-an-event-coverage-record\">6. Release an event-coverage record<\/a><\/li>\n<li><a href=\"#7-request-the-actual-transient-and-acquisition-context\">7. Request the actual transient and acquisition context<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Cz\u0119sto zadawane pytania<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Spis tre\u015bci<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Prze\u0142\u0105cznik Spisu Tre\u015bci\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">D\u017awignia kolankowa<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#1_Decide_what_the_event_count_must_prove\" >1. Decide what the event count must prove<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#2_Distinguish_three_timing_boundaries\" >2. Distinguish three timing boundaries<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#3_Recalculate_an_explicitly_assumed_holdoff_timeline\" >3. Recalculate an explicitly assumed holdoff timeline<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#4_Segmented_memory_still_needs_a_coverage_check\" >4. Segmented memory still needs a coverage check<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#5_Compare_independent_event_and_acquisition_timestamps\" >5. Compare independent event and acquisition timestamps<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#6_Release_an_event-coverage_record\" >6. Release an event-coverage record<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#7_Request_the_actual_transient_and_acquisition_context\" >7. Request the actual transient and acquisition context<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#Frequently_Asked_Questions\" >Cz\u0119sto zadawane pytania<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#Does_the_saved_record_count_equal_the_number_of_physical_events\" >Does the saved record count equal the number of physical events?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#Does_reducing_holdoff_guarantee_every_repeated_event_is_captured\" >Does reducing holdoff guarantee every repeated event is captured?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#Can_segmented_memory_prove_there_were_no_missed_events\" >Can segmented memory prove there were no missed events?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/pl\/news\/trigger-holdoff-event-capture-coverage\/#Does_this_example_characterize_RSP-350-12_transient_behavior\" >Does this example characterize RSP-350-12 transient behavior?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"1-decide-what-the-event-count-must-prove\"><span class=\"ez-toc-section\" id=\"1_Decide_what_the_event_count_must_prove\"><\/span>1. Decide what the event count must prove<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An OEM validation engineer may capture repeated load changes and find fewer voltage-dip records than expected. The difference does not immediately establish that the equipment ignored those commands. First determine whether the acquisition configuration was able to recognize each required event as a new trigger.<\/p>\n<p>The <a href=\"https:\/\/www.wehopower.com\/pl\/product\/rsp-350-ac-to-dc-power-supply-with-pfc\/\">WEHO RSP-350-12 product reference<\/a> identifies one source in the equipment context. The acquisition example below describes a hypothetical external instrument configuration. It does not establish the supply&#39;s transient response, the number of actual faults or the event-detection performance of a named oscilloscope.<\/p>\n<p>The <a href=\"https:\/\/download.tek.com\/manual\/071027401.pdf\" target=\"_blank\" rel=\"noopener\">Tektronix TDS3000 manual<\/a> describes holdoff as inhibiting recognition of new trigger events in its documented timing sequence. Holdoff can deliberately stabilize a complex waveform display. The same behavior can make a configuration unsuitable for counting every repeated event unless its coverage is checked.<\/p>\n<h2 id=\"2-distinguish-three-timing-boundaries\"><span class=\"ez-toc-section\" id=\"2_Distinguish_three_timing_boundaries\"><\/span>2. Distinguish three timing boundaries<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A physical event is an occurrence in the equipment or stimulus. A recognized trigger is an instrument decision based on its enabled conditions. A retained record is the acquired data saved around that decision. One record can contain several physical pulses, and a pulse during an inhibited interval may produce no new record.<\/p>\n<p>Holdoff timing is instrument- and mode-specific. <a href=\"https:\/\/helpfiles.keysight.com\/csg\/89600B\/Webhelp\/Subsystems\/gui\/content\/input_trigger_hold-off_style.htm\" target=\"_blank\" rel=\"noopener\">Keysight&#39;s holdoff-style documentation<\/a> distinguishes conventional time-after-trigger holdoff from conditions requiring the input to remain above or below a level. A numerical holdoff value is incomplete without its selected style and definition.<\/p>\n<p>Rearming is another boundary. <a href=\"https:\/\/spectrum-instrumentation.com\/support\/knowledgebase\/hardware_features\/Re-Arm_Time.php\" target=\"_blank\" rel=\"noopener\">Spectrum Instrumentation&#39;s rearm explanation<\/a> describes the interval between a segment ending and readiness for another segment in its digitizers, including platform-dependent conditions. Do not use one instrument family&#39;s minimum number as a universal scope specification.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Boundary<\/th>\n<th scope=\"col\">Required record<\/th>\n<th scope=\"col\">Possible exclusion<\/th>\n<th scope=\"col\">Verification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Physical stimulus<\/td>\n<td>Independent event count and timestamps<\/td>\n<td>Command may not create the assumed event<\/td>\n<td>Observe actual stimulus<\/td>\n<\/tr>\n<tr>\n<td>Trigger eligibility<\/td>\n<td>Condition, holdoff style and timing origin<\/td>\n<td>Event arrives while trigger is inhibited<\/td>\n<td>Reproduce controlled spacing<\/td>\n<\/tr>\n<tr>\n<td>Acquisition<\/td>\n<td>Record duration and channel settings<\/td>\n<td>New trigger cannot create another record<\/td>\n<td>Check actual mode behavior<\/td>\n<\/tr>\n<tr>\n<td>Rearm and storage<\/td>\n<td>Readiness, segment count and timestamps<\/td>\n<td>Event arrives before readiness or after stop<\/td>\n<td>Compare records with independent events<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"3-recalculate-an-explicitly-assumed-holdoff-timeline\"><span class=\"ez-toc-section\" id=\"3_Recalculate_an_explicitly_assumed_holdoff_timeline\"><\/span>3. Recalculate an explicitly assumed holdoff timeline<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assume four actual stimulus events occur at 0, 2, 4 and 6 ms. Each satisfies the chosen trigger condition when triggering is enabled. Assume a conventional 5 ms holdoff beginning at an accepted trigger, a 1 ms record beginning at that trigger and no additional limiting rearm delay for this initial example.<\/p>\n<p>The event at 0 ms is accepted and starts the declared holdoff interval from 0 to 5 ms. The events at 2 and 4 ms occur inside that interval and cannot generate new triggers under these assumptions. The 6 ms event occurs after holdoff ends and can produce the next record.<\/p>\n<p>The result is four physical events but two accepted triggers and two one-millisecond records. Because the record beginning at 0 ms ends at 1 ms, it does not include the 2 or 4 ms events either. Their absence from the saved records says nothing about whether the stimulus actually occurred.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"K14-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/7158eb5c17f81b61-technical.svg\" alt=\"Assumed event timeline shows two pulses excluded by trigger holdoff before separate records can start.\" width=\"1200\" height=\"675\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Invented events at 0\/2\/4\/6ms, 5ms conventional holdoff from accepted trigger and 1ms records yield triggers at 0\/6ms; additional readiness limits omitted. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/7158eb5c17f81b61-technical.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>The accepted record count is 2\/4 = 50% of the known event count in this invented four-event sequence. That arithmetic is not a statistical detection probability or an instrument performance specification. It simply identifies deterministic exclusions caused by the selected assumed timeline.<\/p>\n<p>If holdoff were reduced to an invented 1.5 ms from each accepted trigger, with the same 1 ms records and readiness achieved before each next event, all four events could trigger. The conditional readiness statement matters: a longer acquisition or additional dead time could still prevent complete capture despite the shorter holdoff.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Stimulus time<\/th>\n<th scope=\"col\">Assumed trigger state<\/th>\n<th scope=\"col\">New record?<\/th>\n<th scope=\"col\">Pow\u00f3d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0 ms<\/td>\n<td>Eligible before first event<\/td>\n<td>Yes, 0\u20131 ms<\/td>\n<td>Starts 5 ms holdoff<\/td>\n<\/tr>\n<tr>\n<td>2 ms<\/td>\n<td>Inhibited<\/td>\n<td>No<\/td>\n<td>Inside 0\u20135 ms interval<\/td>\n<\/tr>\n<tr>\n<td>4 ms<\/td>\n<td>Inhibited<\/td>\n<td>No<\/td>\n<td>Inside 0\u20135 ms interval<\/td>\n<\/tr>\n<tr>\n<td>6 ms<\/td>\n<td>Eligible under declared assumptions<\/td>\n<td>Yes, 6\u20137 ms<\/td>\n<td>Previous holdoff ended<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>This example deliberately avoids events exactly on the holdoff boundary. Actual instruments can have trigger qualification, timing quantization and mode-dependent readiness rules. Resolve close-boundary behavior from the selected instrument&#39;s documentation and a controlled verification rather than using rounded diagram coordinates as a guaranteed timing margin.<\/p>\n<h2 id=\"4-segmented-memory-still-needs-a-coverage-check\"><span class=\"ez-toc-section\" id=\"4_Segmented_memory_still_needs_a_coverage_check\"><\/span>4. Segmented memory still needs a coverage check<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Segmented acquisition can preserve many short records while avoiding long inactive intervals. It does not establish that every event was recognized or that all periods between segments were observed. Record the segment length, trigger configuration, supported acquisition mode and behavior when the chosen segment count is reached.<\/p>\n<p><a href=\"https:\/\/helpfiles.keysight.com\/csg\/89600B\/Webhelp\/Subsystems\/pulse\/content\/pulse_segmenteddataacquisition.htm\" target=\"_blank\" rel=\"noopener\">Keysight&#39;s segmented-acquisition documentation<\/a> describes segment boundaries and warns that partial pulses can be excluded from its pulse metrics. The retained waveform, detected pulse table and segment count are therefore different evidence objects. Use the object that answers the actual validation requirement.<\/p>\n<p>Pretrigger coverage determines how much lead-in is retained within an accepted record. Increasing pretrigger coverage cannot by itself recover events for which no separate acquisition was started. Establish trigger eligibility first, then verify the useful window around each accepted trigger.<\/p>\n<p>Similarly, a stable averaged trace can combine already acquired events without preserving the exceptional event of interest. Averaging and holdoff act at different stages. Keep individual records and acquisition-state evidence when the requirement concerns rare excursions, event-by-event behavior or maximum observed deviation.<\/p>\n<h2 id=\"5-compare-independent-event-and-acquisition-timestamps\"><span class=\"ez-toc-section\" id=\"5_Compare_independent_event_and_acquisition_timestamps\"><\/span>5. Compare independent event and acquisition timestamps<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use a known event source or an appropriately independent observation to establish what actually occurred. A software command log may establish requested commands without proving that the physical pulse occurred at exactly that time. Identify the measured event boundary and timestamp uncertainty before calculating coverage.<\/p>\n<p>A regular burst is particularly useful for exposing intentional exclusions. Vary the spacing across the required range and compare the independent event timestamps with acquisition timestamps. Do not infer the fastest reliable event rate from a favorable sequence alone; verify the actual channels, record length and acquisition mode used in the intended test.<\/p>\n<figure class=\"article-figure product\" data-asset=\"K14-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/pl\/product\/rsp-350-ac-to-dc-power-supply-with-pfc\/\" aria-label=\"RSP-350-12 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/094a3f092649d0a9-rsp-350-12-product-reference.avif\" alt=\"RSP-350-12 product reference preserving the original housing, visible label and connection features.\" width=\"1000\" height=\"1000\" decoding=\"async\" title=\"\"><\/a><figcaption>Product appearance reference for RSP-350-12, preserving the source housing, visible label and connections. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/45a484f0aef16068-product-original.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"6-release-an-event-coverage-record\"><span class=\"ez-toc-section\" id=\"6_Release_an_event-coverage_record\"><\/span>6. Release an event-coverage record<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Define the counted object.<\/strong> Record whether the requirement concerns physical events, triggers, records or pulses visible within records. Verify that the chosen count answers the equipment question.<\/li>\n<li><strong>Record the trigger rules.<\/strong> Save condition, mode, holdoff style, timing origin and value. Verify the actual instrument documentation instead of assuming a generic timing equation.<\/li>\n<li><strong>Bound acquisition readiness.<\/strong> Record sample rate, record duration, segmentation and stop behavior. Verify the relevant rearm and trigger-ready conditions for that configuration.<\/li>\n<li><strong>Apply known events.<\/strong> Record independent stimulus timestamps and saved acquisition timestamps. Verify coverage at the required event spacings and retain unmatched events as explicit evidence.<\/li>\n<li><strong>Release the usable configuration.<\/strong> Record accepted settings, demonstrated spacing range and unresolved blind intervals. Verify that later changes in channels, memory or processing trigger an appropriate coverage review.<\/li>\n<\/ol>\n<p>A report can honestly state that two records were captured from four known events without claiming a two-event equipment history. That distinction helps the receiving engineering team decide whether the acquisition is adequate or needs a different trigger strategy or recording method.<\/p>\n<h2 id=\"7-request-the-actual-transient-and-acquisition-context\"><span class=\"ez-toc-section\" id=\"7_Request_the_actual_transient_and_acquisition_context\"><\/span>7. Request the actual transient and acquisition context<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For an <a href=\"https:\/\/www.wehopower.com\/pl\/product\/rsp-350-ac-to-dc-power-supply-with-pfc\/\">RSP-350-12 transient review<\/a>, provide input and load states, receiver requirements, independent event timing and original acquisition files. Include holdoff, record length and readiness information. Request matching product documentation while preserving the evidence needed to distinguish equipment behavior from acquisition exclusions.<\/p>\n<h2 id=\"frequently-asked-questions\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Cz\u0119sto zadawane pytania<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"does-the-saved-record-count-equal-the-number-of-physical-events\"><span class=\"ez-toc-section\" id=\"Does_the_saved_record_count_equal_the_number_of_physical_events\"><\/span>Does the saved record count equal the number of physical events?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Trigger inhibition, acquisition readiness and storage conditions can exclude events. An independent event record is needed before treating saved acquisitions as an occurrence count.<\/p>\n<h3 id=\"does-reducing-holdoff-guarantee-every-repeated-event-is-captured\"><span class=\"ez-toc-section\" id=\"Does_reducing_holdoff_guarantee_every_repeated_event_is_captured\"><\/span>Does reducing holdoff guarantee every repeated event is captured?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Acquisition duration, rearming, trigger qualification and stop conditions can still limit coverage. Verify the complete configuration at the required event spacing.<\/p>\n<h3 id=\"can-segmented-memory-prove-there-were-no-missed-events\"><span class=\"ez-toc-section\" id=\"Can_segmented_memory_prove_there_were_no_missed_events\"><\/span>Can segmented memory prove there were no missed events?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Segmentation organizes retained data, while trigger and readiness conditions determine which events can start records. Compare independent timestamps and account for the applicable gaps.<\/p>\n<h3 id=\"does-this-example-characterize-rsp-350-12-transient-behavior\"><span class=\"ez-toc-section\" id=\"Does_this_example_characterize_RSP-350-12_transient_behavior\"><\/span>Does this example characterize RSP-350-12 transient behavior?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. It illustrates a hypothetical acquisition timeline. Supply behavior requires actual input, load and voltage\/current evidence collected with an appropriate verified measurement configuration.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Check trigger holdoff, acquisition length and rearm behavior against independent event timestamps before treating saved scope records as an event count.<\/p>","protected":false},"author":2,"featured_media":23263,"parent":0,"menu_order":0,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-24010","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news\/24010","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/comments?post=24010"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news\/24010\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/media\/23263"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/media?parent=24010"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/pl\/wp-json\/wp\/v2\/news_category?post=24010"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}