Single-Output Versions: LRS-60-12, LRS-60-15, LRS-60-24 and LRS-60-48 provide 12V, 15V, 24V and 48V, with listed current ranges of 0~5A, 0~4A, 0~2.5A and 0~1.3A respectively.
Line and Load Stability: Both are listed at ±0.5%; DC output-voltage adjustment is ±10%.
Input Range: 85~264VAC or 120~373VDC, 47~63Hz.
Overload Protection: 110%~150%, cutting off the output with automatic recovery. Overcurrent and short-circuit protection are also listed.
Dimensions and Temperature: 99×82×30mm; working temperature -20℃ to +70℃.
Если у вас есть какие-либо вопросы, пожалуйста, не стесняйтесь обращаться к нам по адресу Электронная почта: [email protected]

Overview

The LRS-60 is an enclosed single-output power supply for proposed integration into commercial ticket and service equipment. The LRS-60 specification lists LRS-60-12, LRS-60-15, LRS-60-24, LRS-60-48. Its compact footprint leaves more room for receipt paths, user interfaces and service access. Specify the connected devices, selected output and duty cycle for an integration review.

Why Choose LRS-60?

Keep service-terminal packaging compact

The LRS-60 dimensions are 99×82×30mm. Use the stated body size to plan the equipment compartment, then allocate additional wiring and service space.

Match the device rail before sizing

The documented output choices are 12V 0~5A; 15V 0~4A; 24V 0~2.5A; 48V 0~1.3A. Match the equipment voltage first so the selected version serves a defined DC rail rather than a collection of incompatible loads.

Reduce regional AC-input variants

The LRS-60 input range is 85–264VAC or 120–373VDC; the table lists 47–63Hz. The documented AC range is useful when the same host equipment design is evaluated for different regional supplies.

Plan recovery around real load behavior

Overload protection is specified as 110%–150%, with output cut-off and automatic recovery. Coordinate the host restart sequence and real peripheral demand around that stated response.

Features, Benefits & Advantages

Особенность Benefit in equipment design
Output alternatives for peripheral electronics The output table lists 12V 0~5A; 15V 0~4A; 24V 0~2.5A; 48V 0~1.3A. Use the selected output column as the starting point for the connected-device budget.
Documented regulation and ripple figures Line regulation and load regulation are each ±0.5%. The wave-and-noise figures are 120mVp-p, 120mVp-p, 150mVp-p, 200mVp-p for the output columns in the listed order. Compare these figures with the electronics tolerance and any required downstream filtering.
Adjustment for final load matching The DC-voltage adjustment range is ±10%. Set the output only within the connected equipment limits, and check voltage at the load under representative demand.
Defined overload response The source lists overload, overcurrent and short-circuit protection. The overload response is output cut-off and automatic recovery at the stated 110%–150% range. This response helps define host fault handling; it is not extra continuous load capacity.
Спецификация LRS-60-12 LRS-60-15 LRS-60-24 LRS-60-48
Выходное напряжение постоянного тока, ток 12V 0~5A 15V 0~4A 24V 0~2.5A 48V 0~1.3A
Волна и шум 120 мВ (пик-пик) 120 мВ (пик-пик) 150 мВ (пик-пик) 200 мВпик-пик
Стабильность входного провода ±0,5% ±0,5% ±0,5% ±0,5%
Стабильность нагрузки ±0,5% ±0,5% ±0,5% ±0,5%
Эффективность 86% 88% 88% 90%
Регулируемый диапазон напряжения постоянного тока ±10% ±10% ±10% ±10%
Диапазон входного напряжения 85~264VAC / 120~373VDC, 47~63Hz
Ударный ток Ток холодного пуска 45 А/230 В переменного тока
Защита от перегрузки 110% ~ 150% отключать выход, автоматическое восстановление
Другая защита Overcurrent protection /Short-circuit protection
Timing (setup / rise / hold-up) 230VAC: 1000ms, 30ms; 115VAC: 2000ms, 30ms. No separate hold-up time is specified.
Выдерживая напряжение I/P-O/P: 1,5 кВ I/P-FG: 1,5 кВ O/P-FG: 0,5 кВ 1 минута
Сопротивление изоляции I/P-O/P I/P-FG O/P-FG: 100 МОм/500 В постоянного тока/25 ℃/70%RH
Рабочая температура -20℃~+70℃
Измерение 99×82×30mm
Масса 0.23kg
Упаковка 44×36.5×19.5CM/80PCS/16kg

Mechanical dimensions

LRS-60 — dimensions in millimetres
Body length99 mm
Body width82 mm
Body height30 mm

The body dimensions and mounting-hole dimensions are different references. The vector drawing below retains the dimensions printed in the WEHO original.

On a small screen, swipe the drawing horizontally to inspect every dimension. No separate drawing image or script download is required.

Exact mechanical drawing from the WEHO original. Units: mm. Use the printed body, mounting and hole dimensions separately.

Typical Service Conditions

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


Select 90–132VAC or 180–264VAC manually before energizing, then verify the chosen DC output and polarity.

Input matching: LRS-60 versus the selector example

The illustration shows the LRS-350 manual-range example; do not transfer its 90–132/180–264 VAC bands to LRS-60. The LRS-60 input range is 85–264VAC or 120–373VDC; the table lists 47–63Hz. Check the actual incoming supply and the complete input-protection arrangement before commissioning. Match the selected DC version to every connected input, then include simultaneous demand and startup transients before energising the equipment. The planning image is a representative LRS-series example, not an exact-model wiring diagram.

LRS-350 manual-selector planning example; use LRS-60 input bands, selection instructions and output options, not the example labels.


Keep fan and ventilation openings unobstructed inside a cabinet selected for the actual environment. Arrows show conceptual airspace, not a measured airflow path.

LRS-60 enclosure and service-space planning

The printed dimensions are 99×82×30mm and the weight is 0.23kg. Reserve additional space for wiring, access and the host ventilation arrangement; the body dimensions are not installation clearances. Reserve additional space for terminal access, conductor routing and the host equipment's airflow; the case outline is not a clearance allowance.

LRS-series cabinet-space concept; the exact case, cooling method and mounting are defined by this model's own technical data.


The −20°C to +70°C working range does not establish full output at every temperature. Use the selected version’s load and thermal limits.

Temperature and duty-cycle assessment for LRS-60

The specified working-temperature range is -20°C to +70°C. The source does not provide a derating curve, a full-load temperature guarantee or a specified cooling method. Measure the temperature at the installed supply and review the longest expected duty cycle. Keep vents unobstructed; do not substitute room temperature for the operating temperature inside the equipment.

LRS-350 temperature-planning example, not a measured derating curve or a replacement for LRS-60 operating limits.


Functional power-planning illustration only. Have qualified personnel select protection, follow terminal markings and verify safe isolation before work.

LRS-60 fault recovery and protected installation

Overload protection is 110%–150%, with output cut-off and automatic recovery; overcurrent and short-circuit protection are also listed. Coordinate the host fault response and branch protection with real load behavior; automatic recovery is not a redundancy or backup function. Have a qualified installer check terminal identification, protective earthing and branch protection for the actual assembly. Coordinate restart behaviour with the equipment controls rather than treating supply recovery as a safety function.

Functional power-planning illustration only; follow the exact model's terminal identification and qualified installation instructions.



Application Industries

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


AI illustration of an illuminated retail lightbox and storefront at blue hour.

Retail sign-control and LED-module branches

For the illuminated storefront, an LRS-60 branch may support a compatible sign controller and a defined LED-module circuit after a full load check. Include cable drop and module startup. It is not a constant-current LED driver or a source for the complete shop lighting system.

Proposed output: LRS-60-12, with the printed output entry 12V 0~5A.

AI application concept — retail signage, not an installation record for this product.


AI illustration of complete self-service parcel lockers and a central pickup screen in a bright indoor lobby.

Parcel-terminal interface electronics

In a parcel kiosk, assess LRS-60 for the service-interface electronics and pickup-status indication, with door-release coils budgeted separately. Confirm peripheral input windows and any downstream conversion. The cabinet photograph does not establish PoE, battery charging or uninterrupted operation.

Proposed output: LRS-60-24, with the printed output entry 24V 0~2.5A.

AI application concept — parcel-terminal electronics, not an installation record for this product.


AI illustration of a complete guarded automatic carton-packing machine on a production floor.

Carton-packaging auxiliary electronics

A carton-position interface is a possible auxiliary role for LRS-60 when its electronics accept the chosen output. Keep that rail distinct from motion and pneumatic actuation. Assess supply interruption and restart with the machine controller before commissioning.

Proposed output: LRS-60-15, with the printed output entry 15V 0~4A.

AI application concept — carton-packaging auxiliary electronics, not a complete-machine power claim.


AI illustration of an electronics inspection workbench with a supported PCB fixture and optical inspection equipment.

Electronics-fixture auxiliary interfaces

For an inspection bench, consider a compatible LRS-60 branch for fixture interlocks, relay interfaces and non-measurement indicators. Account for simultaneous coil pickup and local conversion. A downstream converter, camera and inspection lamp each need their own input and load acceptance.

Proposed output: LRS-60-24, with the printed output entry 24V 0~2.5A.

AI application concept — electronics-fixture interfaces; no measurement-performance or installed-model claim.



Часто задаваемые вопросы

What DC output options does the LRS-60 specification list?

The listed versions are LRS-60-12: 12V 0~5A; LRS-60-15: 15V 0~4A; LRS-60-24: 24V 0~2.5A; LRS-60-48: 48V 0~1.3A. Each is a separate output choice, not a simultaneous multi-output rail set.

What input range does the LRS-60 require?

The LRS-60 input range is 85–264VAC or 120–373VDC; the table lists 47–63Hz. Check the actual incoming supply and the complete input-protection arrangement before commissioning.

How does the LRS-60 series power statement relate to its output-current table?

The manufacturer summary states “Single output: power 60W”. Its separate output table lists 12V 0~5A; 15V 0~4A; 24V 0~2.5A; 48V 0~1.3A. The sheet does not provide a separate per-version continuous-power row; the series statement and current endpoints remain separate source statements rather than a recalculated continuous rating. Confirm the selected version against the intended continuous and transient load profile without treating the current endpoint as an independently proven continuous-power rating.

What output adjustment does the LRS-60 provide?

The specified DC-voltage adjustment is ±10%. Match the final setting to the connected device limits; adjustment does not turn a selected version into every other output version.

What regulation and wave-and-noise figures does the LRS-60 list?

Line and load regulation are each ±0.5%. Wave and noise are LRS-60-12: 120mVp-p; LRS-60-15: 120mVp-p; LRS-60-24: 150mVp-p; LRS-60-48: 200mVp-p. Compare the load tolerance and measurement arrangement before deciding whether local filtering is needed.

What efficiency figures does the LRS-60 specify?

The efficiency entries are LRS-60-12: 86%; LRS-60-15: 88%; LRS-60-24: 88%; LRS-60-48: 90%. These column-specific figures support loss comparison, not an all-load efficiency guarantee.

What protection response does the LRS-60 document?

Overload protection is 110%–150%, with output cut-off and automatic recovery; overcurrent and short-circuit protection are also listed. Coordinate the host fault response and branch protection with real load behavior; automatic recovery is not a redundancy or backup function.

What input-starting current does the LRS-60 specify?

The inrush entry is “Cold start current 45A/230VAC”. Include input-starting behavior when selecting upstream switching and protection; this is not the DC output-current rating.

What timing values does the LRS-60 actually provide?

Under “Setup, rise, hold up time”, the printed entry is “1000ms,30ms/230VAC 2000ms,30ms/115VAC”. Only the printed time pairs are available; no separate hold-up value or at-full-load condition is stated. An interruption-sensitive controller therefore needs a system-level restart or ride-through assessment, not an assumed hold-up duration.

What temperature and cooling boundaries apply to the LRS-60?

The specified working-temperature range is -20°C to +70°C. The source does not provide a derating curve, a full-load temperature guarantee or a specified cooling method. Keep the host ventilation path clear and assess temperature at the actual mounting location and duty cycle.

What size and weight does the LRS-60 list?

The printed dimensions are 99×82×30mm and the weight is 0.23kg. Reserve additional space for wiring, access and the host ventilation arrangement; the body dimensions are not installation clearances.

What withstand and isolation entries does the LRS-60 provide?

The withstand entry is “I/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1minute”. The isolation-resistance entry is “I/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH”. These are the source test entries, not proof of a product certification or the compliance of the completed equipment.