{"id":21601,"date":"2026-11-11T11:30:59","date_gmt":"2026-11-11T03:30:59","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/xlg-60-24-pulsed-load-peak-budget\/"},"modified":"2026-11-11T11:30:59","modified_gmt":"2026-11-11T03:30:59","slug":"xlg-60-24-pulsed-load-peak-budget","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/","title":{"rendered":"XLG-60-24 Pulsed LED Loads: Check Peak Power Before Average"},"content":{"rendered":"<div class=\"weho-blog\">\n<p><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Size a pulsed lighting system against its peak electrical demand and documented operating limits, not average watts alone.<\/li>\n<li>XLG-60-24 is listed at 24 V, 2.5 A and 60 W; those entries do not establish permission to exceed the rating during a pulse.<\/li>\n<li>Include controller demand and the combined timing of all channels sharing the source.<\/li>\n<li>Treat the worked pulse schedule as a hypothetical screening example, not a tested WEHO strobe application.<\/li>\n<\/ul>\n<figure class=\"article-figure hero\" data-asset=\"hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/ru\/product\/ip67-waterproof-led-driver-ac-95-264v-dc-12v-24v-36v-48v-60w-single-output-constant-current-switching-power-supply\/\" aria-label=\"XLG-60-24 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/xlg-60-24-application.webp\" alt=\"XLG-60-24 Pulsed LED Loads: Check Peak Power Before Average  title=\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" xlg-60-24 pulsed led loads: check peak power before average title =\"\"><\/a><figcaption>AI-assisted machine-vision application illustration using the original XLG-60-24 case and label. The fixed leads and visible mounting provide context only; no strobe interface, tested pulse rating or lighting compatibility is established. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/xlg-60-24-scene-source.webp\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#why-can-a-low-average-load-exceed-the-source-requirement\">Why can a low average load exceed the source requirement?<\/a><\/li>\n<li><a href=\"#which-quantities-belong-in-a-pulsed-load-record\">Which quantities belong in a pulsed-load record?<\/a><\/li>\n<li><a href=\"#what-does-the-complete-peak-versus-average-example-show\">What does the complete peak-versus-average example show?<\/a><\/li>\n<li><a href=\"#how-do-multiple-lighting-channels-change-the-result\">How do multiple lighting channels change the result?<\/a><\/li>\n<li><a href=\"#what-should-the-oem-verify-before-releasing-the-source\">What should the OEM verify before releasing the source?<\/a><\/li>\n<li><a href=\"#what-should-accompany-a-pulsed-load-enquiry\">What should accompany a pulsed-load enquiry?<\/a><\/li>\n<li><a href=\"#engineering-faq\">Engineering FAQ<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u041e\u0433\u043b\u0430\u0432\u043b\u0435\u043d\u0438\u0435<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u044c<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#Why_can_a_low_average_load_exceed_the_source_requirement\" >Why can a low average load exceed the source requirement?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#Which_quantities_belong_in_a_pulsed-load_record\" >Which quantities belong in a pulsed-load record?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#What_does_the_complete_peak-versus-average_example_show\" >What does the complete peak-versus-average example show?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#How_do_multiple_lighting_channels_change_the_result\" >How do multiple lighting channels change the result?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#What_should_the_OEM_verify_before_releasing_the_source\" >What should the OEM verify before releasing the source?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#What_should_accompany_a_pulsed-load_enquiry\" >What should accompany a pulsed-load enquiry?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#Engineering_FAQ\" >Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#Can_I_select_a_60_W_supply_for_a_1008_W_pulse_because_the_average_is_2592_W\" >Can I select a 60 W supply for a 100.8 W pulse because the average is 25.92 W?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#Does_a_current-limit_figure_establish_a_pulse-overload_rating\" >Does a current-limit figure establish a pulse-overload rating?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#Can_controller_energy_storage_reduce_source-side_peak_current\" >Can controller energy storage reduce source-side peak current?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/ru\/news\/xlg-60-24-pulsed-load-peak-budget\/#Does_passing_the_nominal_peak_comparison_finish_qualification\" >Does passing the nominal peak comparison finish qualification?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"why-can-a-low-average-load-exceed-the-source-requirement\"><span class=\"ez-toc-section\" id=\"Why_can_a_low_average_load_exceed_the_source_requirement\"><\/span>Why can a low average load exceed the source requirement?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A lighting channel can draw a high current for a short interval while consuming relatively little energy over a longer cycle. The source still encounters the instantaneous electrical demand. For an OEM machine-vision designer, an energy calculation and a source-capability decision therefore answer different questions.<\/p>\n<p>\u0410 <a href=\"https:\/\/www.wehopower.com\/ru\/product\/ip67-waterproof-led-driver-ac-95-264v-dc-12v-24v-36v-48v-60w-single-output-constant-current-switching-power-supply\/\">XLG-60-24 supply product information<\/a> identifies a 24 V, 2.5 A, 60 W variant. This article uses that documented reference to show what an initial screen can establish. It does not claim that the driver provides a strobe input, a particular pulse-overload capability or compatibility with an unspecified light controller.<\/p>\n<h2 id=\"which-quantities-belong-in-a-pulsed-load-record\"><span class=\"ez-toc-section\" id=\"Which_quantities_belong_in_a_pulsed-load_record\"><\/span>Which quantities belong in a pulsed-load record?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Record on-state current, off-state current, pulse duration and repetition period for each electrical load. For a constant-voltage calculation, include the relevant supply voltage and the controller\u2019s own demand. A timing label such as \u201c20% duty\u201d is incomplete without the current levels and time scale.<\/p>\n<p>For an ideal rectangular schedule, duty ratio D equals on-time divided by repetition period. Average current is Iavg = Ion \u00d7 D + Ioff \u00d7 (1 \u2212 D). This equation describes the stated waveform; it does not include startup, edge transients or undocumented behavior.<\/p>\n<p>Pulse duration matters independently of duty ratio. Two loads can have the same average current while one produces short frequent events and another produces a long sustained demand. The source\u2019s applicable dynamic limits and protection behavior must cover the actual event, including its repetition and recovery conditions.<\/p>\n<p>Distinguish the source port from the LED port when a controller or energy-storage stage sits between them. A controller may change what the source sees, but its effect must be supported by its documented input requirements and measurements. An LED-side pulse current cannot simply be renamed as source current, or assumed to disappear behind a controller.<\/p>\n<figure class=\"article-figure product\" data-asset=\"product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/ru\/product\/ip67-waterproof-led-driver-ac-95-264v-dc-12v-24v-36v-48v-60w-single-output-constant-current-switching-power-supply\/\" aria-label=\"XLG-60-24 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/xlg-60-24-product-reference.webp\" alt=\"XLG-60-24 Pulsed LED Loads: Check Peak Power Before Average  title=\" width=\"800\" height=\"800\" decoding=\"async\" xlg-60-24 pulsed led loads: check peak power before average title =\"\"><\/a><figcaption>Official product identity reference, uniformly resized without changing the original product, labels or fixed leads. Product appearance does not prove application approval. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/xlg-60-24-original.jpg\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"what-does-the-complete-peak-versus-average-example-show\"><span class=\"ez-toc-section\" id=\"What_does_the_complete_peak-versus-average_example_show\"><\/span>What does the complete peak-versus-average example show?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A complete example compares the entire simultaneous source demand with the documented source limits, then keeps dynamic qualification open. The following <strong>Hypothetical Pulsed-Load Example<\/strong> assumes a 24 V branch with a rectangular current schedule; it contains no measured WEHO waveform or customer installation.<\/p>\n<p>Assume that the lighting channel draws 4.0 A when on and 0.1 A when off. It is on for 2 ms in every 10 ms period. A separate controller draws a constant assumed 0.2 A from the same 24 V source.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Quantity<\/th>\n<th scope=\"col\">Calculation<\/th>\n<th scope=\"col\">Result<\/th>\n<th scope=\"col\">Meaning<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Duty ratio<\/td>\n<td>2 ms \u00f7 10 ms<\/td>\n<td>0.20 = 20%<\/td>\n<td>Assumed rectangular schedule<\/td>\n<\/tr>\n<tr>\n<td>Lighting average current<\/td>\n<td>4.0 \u00d7 0.20 + 0.1 \u00d7 0.80<\/td>\n<td>0.88 A<\/td>\n<td>Cycle average, excluding controller<\/td>\n<\/tr>\n<tr>\n<td>Total average current<\/td>\n<td>0.88 + 0.20<\/td>\n<td>1.08 A<\/td>\n<td>Assumed source-side average<\/td>\n<\/tr>\n<tr>\n<td>Average output power<\/td>\n<td>24 V \u00d7 1.08 A<\/td>\n<td>25.92 W<\/td>\n<td>Average DC output, not AC input energy<\/td>\n<\/tr>\n<tr>\n<td>Simultaneous peak current<\/td>\n<td>4.0 + 0.20<\/td>\n<td>4.20 A<\/td>\n<td>Demand during the on interval<\/td>\n<\/tr>\n<tr>\n<td>Peak output power<\/td>\n<td>24 V \u00d7 4.20 A<\/td>\n<td>100.8 W<\/td>\n<td>Above the listed 60 W reference<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The 25.92 W average does not approve this load for XLG-60-24. The assumed 4.20 A peak is above the listed 2.5 A rating, and the corresponding 100.8 W is above 60 W. The available product entries do not establish an applicable pulse exception, so this proposed combination cannot be approved from these calculations.<\/p>\n<p>Consider a second hypothetical channel drawing 2.0 A when on, with the same 0.1 A off current, timing and 0.2 A controller. Its average is 0.68 A, or 16.32 W at 24 V. Its peak is 2.20 A, or 52.8 W. This passes only the simple nominal current-and-power comparison; it still needs the actual operating-condition and dynamic checks.<\/p>\n<p>Neither result establishes light-output quality. Optical intensity, camera exposure, LED pulse limits and inspection acceptance belong to the lighting and vision system\u2019s own evidence. Electrical headroom cannot substitute for that assessment.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/xlg-60-24-engineering-model.svg\" alt=\"XLG-60-24 Pulsed LED Loads: Check Peak Power Before Average  title=\" width=\"1200\" height=\"900\" decoding=\"async\" xlg-60-24 pulsed led loads: check peak power before average title =\"\"><\/div><figcaption>Conceptual Engineering Diagram. Original calculation using the explicit hypothetical inputs in the article; not manufacturer performance, a measured waveform or a validated installation. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/xlg-60-24-engineering-model.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<h2 id=\"how-do-multiple-lighting-channels-change-the-result\"><span class=\"ez-toc-section\" id=\"How_do_multiple_lighting_channels_change_the_result\"><\/span>How do multiple lighting channels change the result?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Add simultaneous currents at the shared source rather than multiplying a single-channel average by an assumed channel count. Preserve the actual timing relationships and include operating modes that can change them, such as manual lighting, fault handling or a production recipe change.<\/p>\n<p>Two channels assumed to run at separate times may overlap when a trigger is retried or a machine is placed in setup mode. That is a requirement to define and verify, not a reason to invent a universal overlap allowance. Record credible combinations with the controller supplier and equipment team.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Operating case<\/th>\n<th scope=\"col\">What the record must show<\/th>\n<th scope=\"col\">Evidence for the decision<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>One channel triggered<\/td>\n<td>Source-port current waveform, duration and repetition<\/td>\n<td>Controller requirements and representative measurements<\/td>\n<\/tr>\n<tr>\n<td>Channels overlap<\/td>\n<td>Combined demand including controller consumption<\/td>\n<td>Defined timing limits and overlap test<\/td>\n<\/tr>\n<tr>\n<td>Manual or setup lighting<\/td>\n<td>Any longer on-time or continuous operating mode<\/td>\n<td>Actual machine-mode behavior and applicable ratings<\/td>\n<\/tr>\n<tr>\n<td>Startup or recovery<\/td>\n<td>Charging, restart and readiness conditions<\/td>\n<td>Exact source\/controller documentation and system verification<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>A source selected for the production pulse schedule may face a different demand in manual mode. Keep that mode in the load requirement even when operators seldom use it. If the system prevents a combination, document and verify the actual control behavior instead of relying on an informal operating expectation.<\/p>\n<h2 id=\"what-should-the-oem-verify-before-releasing-the-source\"><span class=\"ez-toc-section\" id=\"What_should_the_OEM_verify_before_releasing_the_source\"><\/span>What should the OEM verify before releasing the source?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Verify the defined source-side load profile against the exact supply and controller documents, then test the relevant operating modes. The <a href=\"https:\/\/www.wehopower.com\/ru\/product\/ip67-waterproof-led-driver-ac-95-264v-dc-12v-24v-36v-48v-60w-single-output-constant-current-switching-power-supply\/\">XLG-60-24 documented rating reference<\/a> is an initial boundary; it is not a dynamic application approval.<\/p>\n<ol>\n<li><strong>Identify both interfaces.<\/strong> Record the supply model, controller model, light engine and the circuit between them. Establish whether the lights require regulated voltage or controlled current, and confirm the intended connection with the component suppliers.<\/li>\n<li><strong>Collect the complete schedule.<\/strong> Record on\/off levels, durations, repetition, channel overlap and nonproduction modes. Mark assumed values separately from measured values and manufacturer limits.<\/li>\n<li><strong>Check continuous and dynamic requirements.<\/strong> Compare current and power under the relevant input, ambient and mounting conditions. Obtain any applicable transient capability with its duration and conditions; do not infer one from an overload-protection percentage.<\/li>\n<li><strong>Measure the relevant source port.<\/strong> Use a suitable qualified test method and instrument setup to capture voltage and current through startup, pulses and recovery. Define limits before testing; a single slow display reading is not a complete waveform record.<\/li>\n<li><strong>Retain the operating matrix.<\/strong> Associate results with the actual hardware, firmware, wiring and recipe versions. Recheck affected cases after timing or lighting changes, instead of carrying an old approval into a different load profile.<\/li>\n<\/ol>\n<p>The mechanical scene shows an illustrative supply position beside a vision-lighting fixture, not the waveform in the example or a tested WEHO strobe system. Exposure, banding and image-quality qualification remain separate system-level tasks even when the electrical load profile is acceptable.<\/p>\n<h2 id=\"what-should-accompany-a-pulsed-load-enquiry\"><span class=\"ez-toc-section\" id=\"What_should_accompany_a_pulsed-load_enquiry\"><\/span>What should accompany a pulsed-load enquiry?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a href=\"https:\/\/www.wehopower.com\/ru\/contact\/\">Send WEHO the source-side load profile<\/a> with the exact supply candidate, controller, light interface, input and ambient conditions. Include peak current, pulse width, repetition, credible overlap and continuous modes. Ask for the applicable limits and supporting information rather than requesting approval from average watts alone.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"can-i-select-a-60-w-supply-for-a-100-8-w-pulse-because-the-average-is-25-92-w\"><span class=\"ez-toc-section\" id=\"Can_I_select_a_60_W_supply_for_a_1008_W_pulse_because_the_average_is_2592_W\"><\/span>Can I select a 60 W supply for a 100.8 W pulse because the average is 25.92 W?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. The average calculation does not establish permission for that peak. Approval needs documented capability covering its magnitude, duration, repetition and operating conditions, plus system verification. The example does not establish such capability for XLG-60-24.<\/p>\n<h3 id=\"does-a-current-limit-figure-establish-a-pulse-overload-rating\"><span class=\"ez-toc-section\" id=\"Does_a_current-limit_figure_establish_a_pulse-overload_rating\"><\/span>Does a current-limit figure establish a pulse-overload rating?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Protection behavior and a permitted repetitive operating load are different specifications. Obtain the exact product\u2019s applicable dynamic limits and recovery information rather than using a protection percentage as an operating allowance.<\/p>\n<h3 id=\"can-controller-energy-storage-reduce-source-side-peak-current\"><span class=\"ez-toc-section\" id=\"Can_controller_energy_storage_reduce_source-side_peak_current\"><\/span>Can controller energy storage reduce source-side peak current?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>It can change the source-side waveform, but the effect must be established for the actual controller and circuit. Use the controller\u2019s input requirements and measurements; do not transfer LED-side current directly or assume that storage eliminates startup and recharge demand.<\/p>\n<h3 id=\"does-passing-the-nominal-peak-comparison-finish-qualification\"><span class=\"ez-toc-section\" id=\"Does_passing_the_nominal_peak_comparison_finish_qualification\"><\/span>Does passing the nominal peak comparison finish qualification?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. A nominal current-and-power comparison is only one screen. Verify output mode, dynamic response, input and thermal conditions, startup, recovery, wiring and the light system\u2019s own limits for the intended operating matrix.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Screen XLG-60-24 pulsed LED loads using peak current, timing and controller demand. Compare a worked duty-cycle example and send WEHO your source profile.<\/p>","protected":false},"author":2,"featured_media":21584,"parent":0,"menu_order":0,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-21601","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/news\/21601","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/comments?post=21601"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/news\/21601\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/media\/21584"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/media?parent=21601"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/news_category?post=21601"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}