{"id":23278,"date":"2026-11-20T10:07:50","date_gmt":"2026-11-20T02:07:50","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/random-vibration-psd-grms-bands\/"},"modified":"2026-11-20T10:07:50","modified_gmt":"2026-11-20T02:07:50","slug":"random-vibration-psd-grms-bands","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/","title":{"rendered":"Random Vibration PSD: Calculate gRMS and Compare the Bands"},"content":{"rendered":"<div class=\"weho-blog\">\n<blockquote>\n<div class=\"key-takeaways\"><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Integrate acceleration PSD over frequency to obtain mean-square acceleration, then take the square root for gRMS.<\/li>\n<li>Two spectra can have identical gRMS while placing their acceleration content in different frequency bands.<\/li>\n<li>Sum band mean-square contributions before taking the square root; do not add the band RMS values.<\/li>\n<li>A calculated profile total is not a vibration qualification or evidence that two tests are equivalent.<\/li>\n<\/ul>\n<\/div>\n<\/blockquote>\n<figure class=\"article-figure hero\" data-asset=\"H20-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/product\/rsp-320-ac-to-dc-power-supply-with-pfc\/\" aria-label=\"RSP-320-12 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/621437076734a7b9-rsp-320-12-application.avif\" alt=\"RSP-320-12 product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" fetchpriority=\"high\" decoding=\"async\" title=\"\"><\/a><figcaption>RSP-320-12 in an application illustration, not a customer installation photo. Scene created with AI assistance. The image does not establish a vibration test, acceleration PSD or mechanical qualification. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/120585ada0f40e43-application-master.webp\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#1-read-the-spectrum-before-comparing-overall-acceleration\">1. Read the spectrum before comparing overall acceleration<\/a><\/li>\n<li><a href=\"#2-distinguish-spectral-density-mean-square-and-rms\">2. Distinguish spectral density, mean square and RMS<\/a><\/li>\n<li><a href=\"#3-recalculate-two-profiles-with-the-same-grms\">3. Recalculate two profiles with the same gRMS<\/a><\/li>\n<li><a href=\"#4-sum-the-areas-of-a-multiband-profile-correctly\">4. Sum the areas of a multiband profile correctly<\/a><\/li>\n<li><a href=\"#5-verify-the-numerical-profile-and-state-its-limits\">5. Verify the numerical profile and state its limits<\/a><\/li>\n<li><a href=\"#6-send-weho-the-full-spectrum-and-comparison-question\">6. Send WEHO the full spectrum and comparison question<\/a><\/li>\n<li><a href=\"#7-frequently-asked-questions\">7. Frequently asked questions<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#1_Read_the_spectrum_before_comparing_overall_acceleration\" >1. Read the spectrum before comparing overall acceleration<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#2_Distinguish_spectral_density_mean_square_and_RMS\" >2. Distinguish spectral density, mean square and RMS<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#3_Recalculate_two_profiles_with_the_same_gRMS\" >3. Recalculate two profiles with the same gRMS<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#4_Sum_the_areas_of_a_multiband_profile_correctly\" >4. Sum the areas of a multiband profile correctly<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#5_Verify_the_numerical_profile_and_state_its_limits\" >5. Verify the numerical profile and state its limits<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#6_Send_WEHO_the_full_spectrum_and_comparison_question\" >6. Send WEHO the full spectrum and comparison question<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#7_Frequently_asked_questions\" >7. Frequently asked questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#How_is_gRMS_calculated_from_acceleration_PSD\" >How is gRMS calculated from acceleration PSD?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#Are_two_profiles_with_the_same_gRMS_equivalent_vibration_tests\" >Are two profiles with the same gRMS equivalent vibration tests?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#Can_I_add_the_RMS_values_of_separate_frequency_bands\" >Can I add the RMS values of separate frequency bands?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/ru\/news\/random-vibration-psd-grms-bands\/#Do_these_example_PSDs_establish_an_RSP-320-12_vibration_rating\" >Do these example PSDs establish an RSP-320-12 vibration rating?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"1-read-the-spectrum-before-comparing-overall-acceleration\"><span class=\"ez-toc-section\" id=\"1_Read_the_spectrum_before_comparing_overall_acceleration\"><\/span>1. Read the spectrum before comparing overall acceleration<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A random-vibration requirement needs its frequency-dependent spectrum as well as the overall acceleration total. Comparing only gRMS can discard the information that distinguishes two profiles. Begin with the PSD values, frequency bands and interpolation rule, then check the integrated result against the stated overall level.<\/p>\n<p>For a <a href=\"https:\/\/www.wehopower.com\/product\/rsp-320-ac-to-dc-power-supply-with-pfc\/\">WEHO RSP-320 power-supply inquiry<\/a>, identify the RSP-320-12 unit and the actual qualification question separately. The illustrative spectra below are invented arithmetic examples. They are not WEHO test profiles, approved operating conditions, product ratings or proposed substitutes for an applicable test requirement.<\/p>\n<h2 id=\"2-distinguish-spectral-density-mean-square-and-rms\"><span class=\"ez-toc-section\" id=\"2_Distinguish_spectral_density_mean_square_and_RMS\"><\/span>2. Distinguish spectral density, mean square and RMS<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Acceleration power spectral density expresses how mean-square acceleration is distributed over frequency. When acceleration is expressed in g, the PSD unit is g\u00b2\/Hz. Integrating that density over a frequency band gives a mean-square contribution in g\u00b2, and taking the square root of the total gives an RMS acceleration in g. <a href=\"https:\/\/www.spectraldynamics.com\/support\/technical-library\/power-spectral-density-psd-and-grms\" target=\"_blank\" rel=\"noopener\">Spectral Dynamics PSD and gRMS technical note<\/a><\/p>\n<p>Write the calculation as aRMS = \u221a[\u222b PSD(f) df] over the defined frequency range. This article uses a single-axis, one-sided acceleration PSD with zero-mean random acceleration. All example bands are flat rectangles, and the example PSD is zero outside the explicitly listed bands. Those assumptions make each band area equal to PSD level multiplied by bandwidth.<\/p>\n<p>A PSD is not a list of independent peak accelerations. Its vertical value at one frequency does not, by itself, state the total RMS or a maximum instantaneous acceleration. Ansys describes random excitation using frequency-dependent statistical loads and distinguishes the input spectrum from the resulting structural response. <a href=\"https:\/\/ansyshelp.ansys.com\/public\/Views\/Secured\/corp\/v251\/en\/wb_sim\/ds_spectral_analysis_type.html\" target=\"_blank\" rel=\"noopener\">Ansys random-vibration analysis documentation<\/a><\/p>\n<figure class=\"article-figure product\" data-asset=\"H20-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/product\/rsp-320-ac-to-dc-power-supply-with-pfc\/\" aria-label=\"RSP-320-12 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/53457ad8bf70b4c4-rsp-320-12-product-reference.avif\" alt=\"RSP-320-12 product reference preserving original housing, model marking and visible connection details for comparison.\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\" title=\"\"><\/a><figcaption>WEHO RSP-320-12 product identification reference, retaining the source image&#8217;s visible identity. The photograph does not establish a vibration test, acceleration PSD or mechanical qualification. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/2082c49714472208-product-original.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<p>Keep the PSD units visible in exported tables and charts. If a document supplies a different spectral quantity or unit convention, resolve that definition before entering it into a calculation. A curve&#39;s familiar shape and a number labeled \u201coverall\u201d do not establish that the same quantity, frequency range or axis convention has been used.<\/p>\n<h2 id=\"3-recalculate-two-profiles-with-the-same-grms\"><span class=\"ez-toc-section\" id=\"3_Recalculate_two_profiles_with_the_same_gRMS\"><\/span>3. Recalculate two profiles with the same gRMS<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assume profile A is a flat acceleration PSD of 0.0100 g\u00b2\/Hz from 10 to 50 Hz. Its bandwidth is 40 Hz, so its mean-square acceleration is 0.0100 \u00d7 40 = 0.4000 g\u00b2. The overall value is \u221a0.4000 = 0.632456 gRMS. No acceleration content is included outside that band in this teaching model.<\/p>\n<p>Assume profile B is 0.0025 g\u00b2\/Hz from 50 to 210 Hz, a bandwidth of 160 Hz. Its area is 0.0025 \u00d7 160 = 0.4000 g\u00b2, giving the same 0.632456 gRMS. The lower PSD level is spread over a wider and different frequency range; identical area does not make the two curves identical.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Hypothetical profile<\/th>\n<th scope=\"col\">Flat band<\/th>\n<th scope=\"col\">PSD level<\/th>\n<th scope=\"col\">Mean-square area<\/th>\n<th scope=\"col\">Overall acceleration<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A<\/td>\n<td>10\u201350 Hz<\/td>\n<td>0.0100 g\u00b2\/Hz<\/td>\n<td>0.4000 g\u00b2<\/td>\n<td>0.632456 gRMS<\/td>\n<\/tr>\n<tr>\n<td>B<\/td>\n<td>50\u2013210 Hz<\/td>\n<td>0.0025 g\u00b2\/Hz<\/td>\n<td>0.4000 g\u00b2<\/td>\n<td>0.632456 gRMS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure class=\"article-figure technical\" data-asset=\"H20-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/75d6f45bc2b46edf-random-vibration-psd-equal-area-bands.svg\" alt=\"Conceptual acceleration PSD showing equal RMS from different bands and summed three-band mean-square contributions.\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Invented flat spectra A and B both integrate to 0.4000 g\u00b2, giving 0.632456 gRMS in different bands. Profile C sums 0.1000 + 0.4000 + 0.1000 = 0.6000 g\u00b2, giving 0.774597 gRMS. No WEHO rating, test or profile equivalence is claimed. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/75d6f45bc2b46edf-random-vibration-psd-equal-area-bands.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>The two profiles have different frequency content even though their total mean-square acceleration matches. A structure&#39;s frequency-dependent response can therefore differ under A and B. Without the relevant structural behavior and qualification requirements, neither curve can be called more severe for every product, nor can either be substituted for the other on gRMS alone.<\/p>\n<p>The intended comparison is spectral, not a claim about an RSP-320-12 resonance. This article supplies no measured modal frequencies, stress response or fatigue result for that supply. The example demonstrates information lost when a spectrum is reduced to one number, rather than predicting which band would damage a particular product.<\/p>\n<h2 id=\"4-sum-the-areas-of-a-multiband-profile-correctly\"><span class=\"ez-toc-section\" id=\"4_Sum_the_areas_of_a_multiband_profile_correctly\"><\/span>4. Sum the areas of a multiband profile correctly<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Now define a third hypothetical spectrum with three non-overlapping flat bands. The first band is 0.0050 g\u00b2\/Hz over 10\u201330 Hz, the second is 0.0100 over 30\u201370 Hz and the third is 0.0025 over 70\u2013110 Hz. Shared endpoints have zero bandwidth and are not counted as additional finite bands.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Assumed band<\/th>\n<th scope=\"col\">Bandwidth<\/th>\n<th scope=\"col\">PSD<\/th>\n<th scope=\"col\">Mean-square calculation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10\u201330 Hz<\/td>\n<td>20 Hz<\/td>\n<td>0.0050 g\u00b2\/Hz<\/td>\n<td>0.0050 \u00d7 20 = 0.1000 g\u00b2<\/td>\n<\/tr>\n<tr>\n<td>30\u201370 Hz<\/td>\n<td>40 Hz<\/td>\n<td>0.0100 g\u00b2\/Hz<\/td>\n<td>0.0100 \u00d7 40 = 0.4000 g\u00b2<\/td>\n<\/tr>\n<tr>\n<td>70\u2013110 Hz<\/td>\n<td>40 Hz<\/td>\n<td>0.0025 g\u00b2\/Hz<\/td>\n<td>0.0025 \u00d7 40 = 0.1000 g\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Total<\/td>\n<td>Defined bands only<\/td>\n<td>Piecewise constant<\/td>\n<td>0.6000 g\u00b2 \u2192 0.774597 gRMS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The correct total is \u221a(0.1000 + 0.4000 + 0.1000) = \u221a0.6000. Adding \u221a0.1000 + \u221a0.4000 + \u221a0.1000 instead would give approximately 1.264911 g, which is not the RMS of this combined spectrum. Keep each band in mean-square units until the summation is complete.<\/p>\n<p>For a sloping profile, the rectangle method no longer applies to the entire segment. Retain the specified breakpoints and interpolation rule, and integrate the corresponding mathematical curve or use validated software configured for that rule. A straight segment on logarithmic axes is not necessarily a straight segment on linear axes; visual averaging can therefore produce a different area.<\/p>\n<p>Controller software commonly accepts PSD breakpoints, associated frequencies and slope segments while displaying the resulting overall RMS. Preserve that full profile definition alongside the displayed total so a second engineer can reproduce the calculation. A matching total alone cannot verify that the imported spectral shape is correct. <a href=\"https:\/\/www.hbkworld.com\/en\/products\/integrated-systems\/vibration-testing\/controllers\/software\/random\" target=\"_blank\" rel=\"noopener\">HBK random-vibration control documentation<\/a><\/p>\n<h2 id=\"5-verify-the-numerical-profile-and-state-its-limits\"><span class=\"ez-toc-section\" id=\"5_Verify_the_numerical_profile_and_state_its_limits\"><\/span>5. Verify the numerical profile and state its limits<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Identify the spectral quantity.<\/strong> Record acceleration units, PSD units, axis, frequency limits and one-sided or other stated convention. Verify that the source requirement and calculation refer to the same quantity before comparing totals.<\/li>\n<li><strong>Preserve breakpoints and interpolation.<\/strong> Record each level, band boundary and slope definition with the source revision. Verify that imported or transcribed curves retain their shape instead of accepting a matching gRMS number alone.<\/li>\n<li><strong>Integrate in mean-square units.<\/strong> Record each band contribution and the integration method. Verify the units and arithmetic, summing g\u00b2 contributions before taking the final square root.<\/li>\n<li><strong>Compare frequency content explicitly.<\/strong> Record where candidate spectra differ, including absent bands and changed levels. Verify that equal totals have not been mistaken for equivalent response or qualification coverage.<\/li>\n<li><strong>Separate arithmetic from qualification.<\/strong> Record the calculated total and unresolved engineering conditions. Verify any proposed profile substitution against the actual applicable requirement and responsible qualification decision rather than approving it by calculation alone.<\/li>\n<\/ol>\n<p>Retain enough significant figures to reproduce the total, while avoiding false precision in the decision. Rounding 0.632456 to 0.63 gRMS may be suitable for a summary if the detailed spectrum remains available. Rounding should not silently move breakpoints, alter a required level or conceal a discrepancy between the intended and imported profile.<\/p>\n<p>This numerical check does not replace specimen or test-method evaluation. The <a href=\"https:\/\/www.wehopower.com\/news\/power-supply-vibration-rating-match-the-specimen-fixture-and-operating-criteria\/\">WEHO vibration-rating guide<\/a> addresses the specimen, mounting and operating-criteria boundary. For shipment-specific comparisons, use the separate <a href=\"https:\/\/www.wehopower.com\/news\/power-supply-transport-vibration-match-the-test-specimen-and-protocol-to-the-shipment\/\">transport-vibration protocol guide<\/a> alongside the appropriate spectrum evidence.<\/p>\n<h2 id=\"6-send-weho-the-full-spectrum-and-comparison-question\"><span class=\"ez-toc-section\" id=\"6_Send_WEHO_the_full_spectrum_and_comparison_question\"><\/span>6. Send WEHO the full spectrum and comparison question<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Send WEHO the exact <a href=\"https:\/\/www.wehopower.com\/product\/rsp-320-ac-to-dc-power-supply-with-pfc\/\">RSP-320-12 product inquiry<\/a>, original PSD table or file, units, frequency range and calculated gRMS. State whether the task is arithmetic verification, interpreting a supplier document or reviewing a proposed substitution. Include the source requirement and its revision rather than only the overall acceleration number.<\/p>\n<p>The next action is to reconcile the spectrum and integrated total, identify the frequency-band differences and retain the calculation record. Keep qualification approval open until the actual product, requirement and test evidence support that separate decision.<\/p>\n<h2 id=\"7-frequently-asked-questions\"><span class=\"ez-toc-section\" id=\"7_Frequently_asked_questions\"><\/span>7. Frequently asked questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"how-is-grms-calculated-from-acceleration-psd\"><span class=\"ez-toc-section\" id=\"How_is_gRMS_calculated_from_acceleration_PSD\"><\/span>How is gRMS calculated from acceleration PSD?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>gRMS is the square root of the integral of acceleration PSD over the defined frequency range when consistent g-based units and PSD conventions are used. For a flat band, its mean-square contribution is the PSD level multiplied by its bandwidth.<\/p>\n<h3 id=\"are-two-profiles-with-the-same-grms-equivalent-vibration-tests\"><span class=\"ez-toc-section\" id=\"Are_two_profiles_with_the_same_gRMS_equivalent_vibration_tests\"><\/span>Are two profiles with the same gRMS equivalent vibration tests?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No, identical gRMS does not establish equivalent frequency content, structural response or qualification coverage. Compare the full spectra and applicable engineering conditions before considering a substitution.<\/p>\n<h3 id=\"can-i-add-the-rms-values-of-separate-frequency-bands\"><span class=\"ez-toc-section\" id=\"Can_I_add_the_RMS_values_of_separate_frequency_bands\"><\/span>Can I add the RMS values of separate frequency bands?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No, add the mean-square contributions of the defined non-overlapping PSD bands, then take the square root of the sum. Adding each band&#39;s square root directly gives the wrong overall RMS for the examples in this article.<\/p>\n<h3 id=\"do-these-example-psds-establish-an-rsp-320-12-vibration-rating\"><span class=\"ez-toc-section\" id=\"Do_these_example_PSDs_establish_an_RSP-320-12_vibration_rating\"><\/span>Do these example PSDs establish an RSP-320-12 vibration rating?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No, the example PSDs are invented calculations and establish no WEHO product rating or completed test. Obtain the applicable product and qualification evidence before accepting an operating environment or proposed test profile.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Integrate random vibration PSD, compare equal-gRMS spectra, and send WEHO the complete frequency profile before accepting an RSP-320 qualification claim.<\/p>","protected":false},"author":2,"featured_media":22253,"parent":0,"menu_order":35,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-23278","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/news\/23278","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/comments?post=23278"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/news\/23278\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/media\/22253"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/media?parent=23278"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ru\/wp-json\/wp\/v2\/news_category?post=23278"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}