{"id":23428,"date":"2026-11-21T10:16:52","date_gmt":"2026-11-21T02:16:52","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/inductive-repeatability-replacement-position-shift\/"},"modified":"2026-11-21T10:16:52","modified_gmt":"2026-11-21T02:16:52","slug":"inductive-repeatability-replacement-position-shift","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/","title":{"rendered":"Inductive Sensor Repeatability: Check Replacement Shift"},"content":{"rendered":"<div class=\"weho-blog\">\n<div class=\"key-takeaways\"><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Repeatability describes repeated switching under stated conditions, not guaranteed absolute position.<\/li>\n<li>Keep one unit&#39;s ON-point scatter separate from the shift introduced by a replacement unit.<\/li>\n<li>Fix the target, approach direction, reference datum and operating conditions before comparing positions.<\/li>\n<li>Release the installation using its actual position limits and model-specific evidence, rather than nominal sensing distance alone.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"F16-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/th\/product\/lja18-long-cylindrical-inductive-proximity-switch\/\" aria-label=\"LJA18 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/8fca3750ea046198-lja18-application.webp\" alt=\"LJA18 product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" title=\"\"><\/a><figcaption>AI-assisted application illustration of LJA18. The scene does not establish measured sensing distance, unit-to-unit shift or repeatability. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/0617eb2065bd867e-application-master.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#define-the-position-that-the-machine-needs\">Define the position that the machine needs<\/a><\/li>\n<li><a href=\"#keep-the-performance-quantities-separate\">Keep the performance quantities separate<\/a><\/li>\n<li><a href=\"#calculate-within-unit-spread-and-replacement-shift\">Calculate within-unit spread and replacement shift<\/a><\/li>\n<li><a href=\"#control-the-conditions-that-can-move-the-point\">Control the conditions that can move the point<\/a><\/li>\n<li><a href=\"#qualify-the-replacement-task-explicitly\">Qualify the replacement task explicitly<\/a><\/li>\n<li><a href=\"#send-weho-the-positional-requirement\">Send WEHO the positional requirement<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Frequently asked questions<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0e2a\u0e32\u0e23\u0e1a\u0e31\u0e0d<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u0e2a\u0e25\u0e31\u0e1a<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Define_the_position_that_the_machine_needs\" >Define the position that the machine needs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Keep_the_performance_quantities_separate\" >Keep the performance quantities separate<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Calculate_within-unit_spread_and_replacement_shift\" >Calculate within-unit spread and replacement shift<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Control_the_conditions_that_can_move_the_point\" >Control the conditions that can move the point<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Qualify_the_replacement_task_explicitly\" >Qualify the replacement task explicitly<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Send_WEHO_the_positional_requirement\" >Send WEHO the positional requirement<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Frequently_asked_questions\" >Frequently asked questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Is_repeatability_the_same_as_absolute_accuracy\" >Is repeatability the same as absolute accuracy?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Can_nominal_sensing_distance_establish_replacement_precision\" >Can nominal sensing distance establish replacement precision?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Should_ON_and_OFF_readings_be_combined_in_one_spread\" >Should ON and OFF readings be combined in one spread?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/th\/news\/inductive-repeatability-replacement-position-shift\/#Does_adjusting_every_replacement_prove_interchangeability\" >Does adjusting every replacement prove interchangeability?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"define-the-position-that-the-machine-needs\"><span class=\"ez-toc-section\" id=\"Define_the_position_that_the_machine_needs\"><\/span>Define the position that the machine needs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A sensor can repeat its switching point closely while a replacement moves that point outside the machine&#39;s required window. The OEM decision therefore needs two records: repeat behavior within a unit and the permitted change after replacement. A small scatter figure does not establish interchangeability.<\/p>\n<p>For a candidate from the <a href=\"https:\/\/www.wehopower.com\/th\/product\/lja18-long-cylindrical-inductive-proximity-switch\/\">WEHO LJA18 sensor family<\/a>, begin with the complete ordered suffix and applicable target and mounting information. The pictured family reference does not establish a repeatability value or positioning accuracy. Set the required machine behavior before interpreting any manufacturer tolerance.<\/p>\n<p>Define whether position means an axial gap, a flag edge crossing a fixture datum or another physical coordinate. State the required electrical transition and the direction from which it is approached. An ON position measured on one motion path cannot silently become an OFF position or a precision claim on another path.<\/p>\n<h2 id=\"keep-the-performance-quantities-separate\"><span class=\"ez-toc-section\" id=\"Keep_the_performance_quantities_separate\"><\/span>Keep the performance quantities separate<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Sensing distance, switching hysteresis and repeatability answer different questions. The nominal distance identifies a defined sensing-range condition. Hysteresis concerns the separation between operate and reset positions, while a repeated same-direction ON study concerns variation around the operate position.<\/p>\n<p>OMRON&#39;s <a href=\"https:\/\/www.ia.omron.com\/support\/guide\/41\/explanation_of_terms.html\" target=\"_blank\" rel=\"noopener\">proximity sensor terms<\/a> define sensing distance and hysteresis separately. Use the exact sensor&#39;s own definitions when comparing specifications. A range value, response frequency or ON\/OFF separation cannot be substituted for a repeatability specification.<\/p>\n<p>OMRON&#39;s <a href=\"https:\/\/www.ia.omron.com\/support\/faq\/answer\/41\/faq00308\/\" target=\"_blank\" rel=\"noopener\">repeat-accuracy FAQ<\/a> also identifies operating conditions and unit-to-unit variation as relevant to positional behavior. The FAQ&#39;s numerical examples belong to its stated context. They do not establish LJA18 performance or a universal allowance for replacing one sensor with another.<\/p>\n<p>The practical consequence is to avoid a single \u201caccuracy\u201d cell in the purchase record. Record the quantity, reference conditions and acceptance task. That makes a same-unit scatter result distinguishable from a replacement-unit position difference.<\/p>\n<figure class=\"article-figure product\" data-asset=\"F16-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/th\/product\/lja18-long-cylindrical-inductive-proximity-switch\/\" aria-label=\"LJA18 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/03b545a0daba8275-lja18-product-reference.webp\" alt=\"LJA18 product reference preserving original housing, model identification and visible connection details for comparison.\" width=\"800\" height=\"800\" decoding=\"async\" title=\"\"><\/a><figcaption>Product reference for LJA18; original visible identity is retained. The scene does not establish measured sensing distance, unit-to-unit shift or repeatability. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/429bc73583cd6e7c-product-original.jpg\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"calculate-within-unit-spread-and-replacement-shift\"><span class=\"ez-toc-section\" id=\"Calculate_within-unit_spread_and_replacement_shift\"><\/span>Calculate within-unit spread and replacement shift<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Consider a <strong>hypothetical fixture-position example<\/strong>, not a sensing-range specification or a WEHO test. A metal flag approaches in the same direction on every trial. Its ON position is expressed in millimetres from a fixed fixture datum, and the project accepts positions from 4.90 to 5.10 mm.<\/p>\n<p>Suppose Unit A produces ON positions of 5.02, 5.00, 5.03, 5.01 and 5.04 mm. The arithmetic mean is 25.10 \u00f7 5 = 5.02 mm. Its observed range is 5.04 \u2212 5.00 = 0.04 mm.<\/p>\n<p>After a documented replacement, Unit B produces 5.28, 5.30, 5.29, 5.31 and 5.32 mm under the same illustrative conditions. Its mean is 26.50 \u00f7 5 = 5.30 mm, and its observed range is also 0.04 mm. The mean shift between these two units is 5.30 \u2212 5.02 = 0.28 mm.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Illustrative quantity<\/th>\n<th scope=\"col\">Unit A<\/th>\n<th scope=\"col\">Unit B<\/th>\n<th scope=\"col\">Decision meaning<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Observed ON interval<\/td>\n<td>5.00\u20135.04 mm<\/td>\n<td>5.28\u20135.32 mm<\/td>\n<td>Same-direction sample observations<\/td>\n<\/tr>\n<tr>\n<td>Observed range<\/td>\n<td>0.04 mm<\/td>\n<td>0.04 mm<\/td>\n<td>Similar within-unit scatter<\/td>\n<\/tr>\n<tr>\n<td>Mean ON position<\/td>\n<td>5.02 mm<\/td>\n<td>5.30 mm<\/td>\n<td>Mean difference is 0.28 mm<\/td>\n<\/tr>\n<tr>\n<td>Inside 4.90\u20135.10 mm window<\/td>\n<td>All five observations<\/td>\n<td>No observations<\/td>\n<td>Small spread did not preserve position<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The example shows why two units with equal observed scatter can produce different release decisions. Unit B&#39;s observations are outside the stated position window even though its five-point range equals Unit A&#39;s. Describing both simply as \u201c0.04 mm repeatable\u201d would conceal the substitution problem.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"F16-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/0e77c854447b6164-inductive-repeatability-replacement-shift.svg\" alt=\"Hypothetical same-direction switching clusters showing similar scatter but different mean position after sensor replacement.\" width=\"1200\" height=\"675\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Five hypothetical ON positions per unit have equal 0.04 mm observed ranges, while their means differ by 0.28 mm. The coordinate is a fixture datum, not a claimed LJA18 sensing distance. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/0e77c854447b6164-inductive-repeatability-replacement-shift.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>Five readings do not establish a guaranteed population range, environmental limit or reliability level. The example only separates the calculations. An actual study needs sufficient observations, relevant units, measurement capability and a decision rule suitable for the required release claim.<\/p>\n<p>Do not rewrite a 0.04 mm observed range as \u00b10.04 mm, \u00b10.02 mm or a standard deviation without defining the intended statistic and its reference. Preserve the raw positions so a later reviewer can recompute the reported quantity. A compact summary should never remove the meaning of its denominator or interval.<\/p>\n<h2 id=\"control-the-conditions-that-can-move-the-point\"><span class=\"ez-toc-section\" id=\"Control_the_conditions_that_can_move_the_point\"><\/span>Control the conditions that can move the point<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Target material, dimensions, support and surrounding metal belong in the position record. A changed target or bracket can move the result without any sensor replacement. Keep those changes separate so that a replacement comparison does not become a mixed configuration comparison.<\/p>\n<p>IFM&#39;s <a href=\"https:\/\/www.ifm.com\/us\/en\/us\/overview\/inductive\/technology-overview\/tech-overview\" target=\"_blank\" rel=\"noopener\">inductive technology overview<\/a> discusses how target geometry and material affect sensing conditions. Its product-specific range relationships are not transferable to LJA18. The relevant general lesson is to preserve the actual target and mounting context when comparing positions.<\/p>\n<p>Record supply and environmental conditions rather than assuming that a room-temperature test covers the equipment&#39;s operating range. If a condition changes deliberately, create a separate row or study block. An environmental shift should not be pooled with repeated observations under fixed conditions and then labelled pure repeatability.<\/p>\n<p>The WEHO hysteresis and mechanical-chatter guide concerns a different quantity: the relationship between ON and OFF positions and motion around them. In a repeatability study, hold the transition direction fixed first. Add reset and chatter tests as separate requirements where the machine needs them.<\/p>\n<h2 id=\"qualify-the-replacement-task-explicitly\"><span class=\"ez-toc-section\" id=\"Qualify_the_replacement_task_explicitly\"><\/span>Qualify the replacement task explicitly<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A maintenance team may reposition a replacement until the machine works. That can be a legitimate documented adjustment, but it means the approved service process includes adjustment and revalidation. It does not demonstrate position interchangeability at an unchanged mechanical setting.<\/p>\n<p>State whether the replacement must work at the retained setting or whether an adjustment procedure is permitted. Define the accessible datum and the verification needed afterward. This prevents an unrecorded field correction from becoming the assumed basis of a production spare policy.<\/p>\n<ol>\n<li><strong>Define the coordinate and transition.<\/strong> Record datum, direction, target and required ON position window. Accept the test definition only when another engineer can reproduce the same physical coordinate and output event.<\/li>\n<li><strong>Establish measurement capability.<\/strong> Identify position resolution, reference checks and event-capture method. Confirm that the method can support the required position limit before interpreting a narrow observed spread.<\/li>\n<li><strong>Measure one unit repeatedly.<\/strong> Retain individual positions under fixed conditions and calculate the declared statistic. Evaluate observations against the project window without treating a sample range as a guaranteed bound.<\/li>\n<li><strong>Replace and compare.<\/strong> Apply the stated unchanged-setting or permitted-adjustment procedure. Calculate both within-unit spread and the shift relative to the approved reference, keeping their acceptance rules separate.<\/li>\n<li><strong>Release the service method.<\/strong> Retain the sensor identity, target revision, setting and verification record. Reopen the assessment when a suffix, bracket, target or required coordinate changes.<\/li>\n<\/ol>\n<h2 id=\"send-weho-the-positional-requirement\"><span class=\"ez-toc-section\" id=\"Send_WEHO_the_positional_requirement\"><\/span>Send WEHO the positional requirement<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For an <a href=\"https:\/\/www.wehopower.com\/th\/product\/lja18-long-cylindrical-inductive-proximity-switch\/\">LJA18 application review<\/a>, provide the full label, target drawing, motion path and required position window. State whether replacement must preserve the setting or may include adjustment. Request applicable repeatability, condition and replacement evidence rather than asking for \u201chigh accuracy\u201d without a defined task.<\/p>\n<h2 id=\"frequently-asked-questions\"><span class=\"ez-toc-section\" id=\"Frequently_asked_questions\"><\/span>Frequently asked questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"is-repeatability-the-same-as-absolute-accuracy\"><span class=\"ez-toc-section\" id=\"Is_repeatability_the_same_as_absolute_accuracy\"><\/span>Is repeatability the same as absolute accuracy?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Repeatability describes variation under repeated stated conditions, while absolute accuracy also concerns agreement with a defined reference. A closely clustered result can remain displaced from the required position.<\/p>\n<h3 id=\"can-nominal-sensing-distance-establish-replacement-precision\"><span class=\"ez-toc-section\" id=\"Can_nominal_sensing_distance_establish_replacement_precision\"><\/span>Can nominal sensing distance establish replacement precision?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Nominal sensing distance and replacement position variation are different requirements. Use the exact model&#39;s documented conditions and a qualification that represents the intended replacement procedure.<\/p>\n<h3 id=\"should-on-and-off-readings-be-combined-in-one-spread\"><span class=\"ez-toc-section\" id=\"Should_ON_and_OFF_readings_be_combined_in_one_spread\"><\/span>Should ON and OFF readings be combined in one spread?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Combining the two transitions can mix hysteresis with repeated-point variation. Evaluate each required transition separately before calculating any additional machine-specific positional quantity.<\/p>\n<h3 id=\"does-adjusting-every-replacement-prove-interchangeability\"><span class=\"ez-toc-section\" id=\"Does_adjusting_every_replacement_prove_interchangeability\"><\/span>Does adjusting every replacement prove interchangeability?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Only within a service method that explicitly includes that adjustment and its verification. It does not prove that replacement units preserve the original switching position at an unchanged setting.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Separate repeated ON-point scatter from replacement shift in a worked position example. Send WEHO your LJA18 label, target and required position window.<\/p>","protected":false},"author":2,"featured_media":22229,"parent":0,"menu_order":26,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-23428","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/news\/23428","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/comments?post=23428"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/news\/23428\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/media\/22229"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/media?parent=23428"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/news_category?post=23428"}],"curies":[{"name":"\u0e2b\u0e19\u0e49\u0e32","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}