{"id":24741,"date":"2026-11-27T10:17:06","date_gmt":"2026-11-27T02:17:06","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/rtd-thermal-hysteresis-heating-cooling\/"},"modified":"2026-11-27T10:17:06","modified_gmt":"2026-11-27T02:17:06","slug":"rtd-thermal-hysteresis-heating-cooling","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/","title":{"rendered":"RTD Thermal Hysteresis: \u0e40\u0e1b\u0e23\u0e35\u0e22\u0e1a\u0e40\u0e17\u0e35\u0e22\u0e1a\u0e40\u0e2a\u0e49\u0e19\u0e17\u0e32\u0e07\u0e01\u0e32\u0e23\u0e43\u0e2b\u0e49\u0e04\u0e27\u0e32\u0e21\u0e23\u0e49\u0e2d\u0e19\u0e41\u0e25\u0e30\u0e01\u0e32\u0e23\u0e25\u0e14\u0e04\u0e27\u0e32\u0e21\u0e23\u0e49\u0e2d\u0e19"},"content":{"rendered":"<div class=\"weho-blog\">\n<div class=\"key-takeaways\"><strong>\u0e02\u0e49\u0e2d\u0e04\u0e34\u0e14\u0e2a\u0e33\u0e04\u0e31\u0e0d\u0e14\u0e49\u0e32\u0e19\u0e27\u0e34\u0e28\u0e27\u0e01\u0e23\u0e23\u0e21<\/strong><\/p>\n<ul>\n<li>RTD thermal hysteresis \u0e40\u0e1b\u0e47\u0e19\u0e01\u0e32\u0e23\u0e1a\u0e48\u0e07\u0e0a\u0e35\u0e49\u0e17\u0e35\u0e48\u0e02\u0e36\u0e49\u0e19\u0e2d\u0e22\u0e39\u0e48\u0e01\u0e31\u0e1a\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e01\u0e32\u0e23\u0e40\u0e1b\u0e25\u0e35\u0e48\u0e22\u0e19\u0e41\u0e1b\u0e25\u0e07\u0e02\u0e2d\u0e07\u0e2d\u0e38\u0e13\u0e2b\u0e20\u0e39\u0e21\u0e34\u0e17\u0e35\u0e48\u0e2d\u0e38\u0e13\u0e2b\u0e20\u0e39\u0e21\u0e34\u0e2d\u0e49\u0e32\u0e07\u0e2d\u0e34\u0e07\u0e40\u0e14\u0e35\u0e22\u0e27\u0e01\u0e31\u0e19.<\/li>\n<li>\u0e43\u0e2b\u0e49\u0e23\u0e31\u0e01\u0e29\u0e32\u0e04\u0e48\u0e32\u0e1c\u0e25\u0e25\u0e31\u0e1e\u0e18\u0e4c\u0e02\u0e2d\u0e07\u0e40\u0e2a\u0e49\u0e19\u0e17\u0e32\u0e07\u0e01\u0e32\u0e23\u0e43\u0e2b\u0e49\u0e04\u0e27\u0e32\u0e21\u0e23\u0e49\u0e2d\u0e19\u0e41\u0e25\u0e30\u0e40\u0e2a\u0e49\u0e19\u0e17\u0e32\u0e07\u0e01\u0e32\u0e23\u0e43\u0e2b\u0e49\u0e04\u0e27\u0e32\u0e21\u0e40\u0e22\u0e47\u0e19\u0e43\u0e2b\u0e49\u0e0a\u0e31\u0e14\u0e40\u0e08\u0e19 \u0e41\u0e17\u0e19\u0e17\u0e35\u0e48\u0e08\u0e30\u0e19\u0e33\u0e21\u0e32\u0e04\u0e33\u0e19\u0e27\u0e13\u0e23\u0e27\u0e21\u0e01\u0e31\u0e19\u0e17\u0e31\u0e19\u0e17\u0e35.<\/li>\n<li>\u0e41\u0e22\u0e01\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e01\u0e32\u0e23\u0e2a\u0e2d\u0e1a\u0e2a\u0e27\u0e19\u0e2d\u0e2d\u0e01\u0e08\u0e32\u0e01\u0e04\u0e27\u0e32\u0e21\u0e40\u0e23\u0e48\u0e07\u0e02\u0e2d\u0e07\u0e41\u0e2b\u0e25\u0e48\u0e07\u0e01\u0e33\u0e40\u0e19\u0e34\u0e14 \u0e1e\u0e24\u0e15\u0e34\u0e01\u0e23\u0e23\u0e21\u0e01\u0e32\u0e23\u0e2d\u0e48\u0e32\u0e19\u0e2d\u0e2d\u0e01 \u0e41\u0e25\u0e30\u0e01\u0e32\u0e23\u0e40\u0e04\u0e25\u0e37\u0e48\u0e2d\u0e19\u0e17\u0e35\u0e48\u0e15\u0e48\u0e2d\u0e40\u0e19\u0e37\u0e48\u0e2d\u0e07.<\/li>\n<li>\u0e01\u0e33\u0e2b\u0e19\u0e14\u0e04\u0e48\u0e32\u0e2d\u0e38\u0e13\u0e2b\u0e20\u0e39\u0e21\u0e34\u0e17\u0e35\u0e48\u0e40\u0e01\u0e35\u0e48\u0e22\u0e27\u0e02\u0e49\u0e2d\u0e07\u0e01\u0e48\u0e2d\u0e19\u0e17\u0e35\u0e48\u0e08\u0e30\u0e22\u0e2d\u0e21\u0e23\u0e31\u0e1a\u0e1c\u0e25\u0e01\u0e32\u0e23\u0e1b\u0e23\u0e31\u0e1a\u0e41\u0e15\u0e48\u0e07\u0e2a\u0e33\u0e2b\u0e23\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e43\u0e0a\u0e49\u0e07\u0e32\u0e19.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"K30-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/th\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\" aria-label=\"TX4-W details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/dc1746a7538df850-tx4-w-application.webp\" alt=\"TX4-W product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" title=\"\"><\/a><figcaption>\u0e20\u0e32\u0e1e\u0e1b\u0e23\u0e30\u0e01\u0e2d\u0e1a\u0e01\u0e32\u0e23\u0e43\u0e0a\u0e49\u0e07\u0e32\u0e19 TX4-W \u0e43\u0e19\u0e2a\u0e20\u0e32\u0e1e\u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c; \u0e44\u0e21\u0e48\u0e43\u0e0a\u0e48\u0e20\u0e32\u0e1e\u0e01\u0e32\u0e23\u0e15\u0e34\u0e14\u0e15\u0e31\u0e49\u0e07\u0e42\u0e14\u0e22\u0e25\u0e39\u0e01\u0e04\u0e49\u0e32. \u0e09\u0e32\u0e01\u0e19\u0e35\u0e49\u0e2a\u0e23\u0e49\u0e32\u0e07\u0e02\u0e36\u0e49\u0e19\u0e42\u0e14\u0e22\u0e21\u0e35\u0e01\u0e32\u0e23\u0e0a\u0e48\u0e27\u0e22\u0e40\u0e2b\u0e25\u0e37\u0e2d\u0e08\u0e32\u0e01 AI. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/c76124328a2bc272-application-master.png\" target=\"_blank\" rel=\"noopener\">\u0e14\u0e39\u0e20\u0e32\u0e1e\u0e43\u0e19\u0e02\u0e19\u0e32\u0e14\u0e15\u0e49\u0e19\u0e09\u0e1a\u0e31\u0e1a<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>\u0e43\u0e19\u0e2b\u0e19\u0e49\u0e32\u0e19\u0e35\u0e49<\/summary>\n<ol>\n<li><a href=\"#ask-whether-the-return-path-changes-the-result\">\u0e16\u0e32\u0e21\u0e14\u0e39\u0e27\u0e48\u0e32\u0e17\u0e32\u0e07\u0e01\u0e25\u0e31\u0e1a\u0e44\u0e1b\u0e19\u0e31\u0e49\u0e19\u0e08\u0e30\u0e40\u0e1b\u0e25\u0e35\u0e48\u0e22\u0e19\u0e1c\u0e25\u0e25\u0e31\u0e1e\u0e18\u0e4c\u0e2b\u0e23\u0e37\u0e2d\u0e44\u0e21\u0e48<\/a><\/li>\n<li><a href=\"#distinguish-history-dependence-from-other-contributions\">\u0e41\u0e22\u0e01\u0e41\u0e22\u0e30\u0e04\u0e27\u0e32\u0e21\u0e1e\u0e36\u0e48\u0e07\u0e1e\u0e32\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e28\u0e32\u0e2a\u0e15\u0e23\u0e4c\u0e2d\u0e2d\u0e01\u0e08\u0e32\u0e01\u0e01\u0e32\u0e23\u0e21\u0e35\u0e2a\u0e48\u0e27\u0e19\u0e23\u0e48\u0e27\u0e21\u0e2d\u0e37\u0e48\u0e19\u0e46<\/a><\/li>\n<li><a href=\"#calculate-a-hypothetical-two-path-difference\">\u0e04\u0e33\u0e19\u0e27\u0e13\u0e04\u0e27\u0e32\u0e21\u0e41\u0e15\u0e01\u0e15\u0e48\u0e32\u0e07\u0e02\u0e2d\u0e07\u0e40\u0e2a\u0e49\u0e19\u0e17\u0e32\u0e07\u0e2a\u0e2d\u0e07\u0e40\u0e2a\u0e49\u0e19\u0e17\u0e35\u0e48\u0e40\u0e1b\u0e47\u0e19\u0e2a\u0e21\u0e21\u0e15\u0e34<\/a><\/li>\n<li><a href=\"#design-a-history-controlled-comparison\">\u0e2d\u0e2d\u0e01\u0e41\u0e1a\u0e1a\u0e01\u0e32\u0e23\u0e40\u0e1b\u0e23\u0e35\u0e22\u0e1a\u0e40\u0e17\u0e35\u0e22\u0e1a\u0e17\u0e35\u0e48\u0e21\u0e35\u0e01\u0e32\u0e23\u0e04\u0e27\u0e1a\u0e04\u0e38\u0e21\u0e14\u0e49\u0e27\u0e22\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e28\u0e32\u0e2a\u0e15\u0e23\u0e4c<\/a><\/li>\n<li><a href=\"#verify-and-release-the-relevant-measurement-use\">\u0e15\u0e23\u0e27\u0e08\u0e2a\u0e2d\u0e1a\u0e41\u0e25\u0e30\u0e1b\u0e25\u0e48\u0e2d\u0e22\u0e01\u0e32\u0e23\u0e43\u0e0a\u0e49\u0e07\u0e32\u0e19\u0e04\u0e48\u0e32\u0e01\u0e32\u0e23\u0e27\u0e31\u0e14\u0e17\u0e35\u0e48\u0e40\u0e01\u0e35\u0e48\u0e22\u0e27\u0e02\u0e49\u0e2d\u0e07<\/a><\/li>\n<li><a href=\"#give-weho-the-history-with-the-controller-enquiry\">\u0e43\u0e2b\u0e49 WEHO \u0e44\u0e14\u0e49\u0e23\u0e31\u0e1a\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e01\u0e32\u0e23\u0e2a\u0e2d\u0e1a\u0e16\u0e32\u0e21\u0e40\u0e01\u0e35\u0e48\u0e22\u0e27\u0e01\u0e31\u0e1a\u0e04\u0e2d\u0e19\u0e42\u0e17\u0e23\u0e25\u0e40\u0e25\u0e2d\u0e23\u0e4c<\/a><\/li>\n<li><a href=\"#engineering-faq\">\u0e04\u0e33\u0e16\u0e32\u0e21\u0e17\u0e35\u0e48\u0e1e\u0e1a\u0e1a\u0e48\u0e2d\u0e22\u0e40\u0e01\u0e35\u0e48\u0e22\u0e27\u0e01\u0e31\u0e1a\u0e27\u0e34\u0e28\u0e27\u0e01\u0e23\u0e23\u0e21<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0e2a\u0e32\u0e23\u0e1a\u0e31\u0e0d<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u0e2a\u0e25\u0e31\u0e1a<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Ask_whether_the_return_path_changes_the_result\" >\u0e16\u0e32\u0e21\u0e14\u0e39\u0e27\u0e48\u0e32\u0e17\u0e32\u0e07\u0e01\u0e25\u0e31\u0e1a\u0e44\u0e1b\u0e19\u0e31\u0e49\u0e19\u0e08\u0e30\u0e40\u0e1b\u0e25\u0e35\u0e48\u0e22\u0e19\u0e1c\u0e25\u0e25\u0e31\u0e1e\u0e18\u0e4c\u0e2b\u0e23\u0e37\u0e2d\u0e44\u0e21\u0e48<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Distinguish_history_dependence_from_other_contributions\" >\u0e41\u0e22\u0e01\u0e41\u0e22\u0e30\u0e04\u0e27\u0e32\u0e21\u0e1e\u0e36\u0e48\u0e07\u0e1e\u0e32\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e28\u0e32\u0e2a\u0e15\u0e23\u0e4c\u0e2d\u0e2d\u0e01\u0e08\u0e32\u0e01\u0e01\u0e32\u0e23\u0e21\u0e35\u0e2a\u0e48\u0e27\u0e19\u0e23\u0e48\u0e27\u0e21\u0e2d\u0e37\u0e48\u0e19\u0e46<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Calculate_a_hypothetical_two-path_difference\" >\u0e04\u0e33\u0e19\u0e27\u0e13\u0e04\u0e27\u0e32\u0e21\u0e41\u0e15\u0e01\u0e15\u0e48\u0e32\u0e07\u0e02\u0e2d\u0e07\u0e40\u0e2a\u0e49\u0e19\u0e17\u0e32\u0e07\u0e2a\u0e2d\u0e07\u0e40\u0e2a\u0e49\u0e19\u0e17\u0e35\u0e48\u0e40\u0e1b\u0e47\u0e19\u0e2a\u0e21\u0e21\u0e15\u0e34<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Design_a_history-controlled_comparison\" >\u0e2d\u0e2d\u0e01\u0e41\u0e1a\u0e1a\u0e01\u0e32\u0e23\u0e40\u0e1b\u0e23\u0e35\u0e22\u0e1a\u0e40\u0e17\u0e35\u0e22\u0e1a\u0e17\u0e35\u0e48\u0e21\u0e35\u0e01\u0e32\u0e23\u0e04\u0e27\u0e1a\u0e04\u0e38\u0e21\u0e14\u0e49\u0e27\u0e22\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e28\u0e32\u0e2a\u0e15\u0e23\u0e4c<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Verify_and_release_the_relevant_measurement_use\" >\u0e15\u0e23\u0e27\u0e08\u0e2a\u0e2d\u0e1a\u0e41\u0e25\u0e30\u0e1b\u0e25\u0e48\u0e2d\u0e22\u0e01\u0e32\u0e23\u0e43\u0e0a\u0e49\u0e07\u0e32\u0e19\u0e04\u0e48\u0e32\u0e01\u0e32\u0e23\u0e27\u0e31\u0e14\u0e17\u0e35\u0e48\u0e40\u0e01\u0e35\u0e48\u0e22\u0e27\u0e02\u0e49\u0e2d\u0e07<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Give_WEHO_the_history_with_the_controller_enquiry\" >\u0e43\u0e2b\u0e49 WEHO \u0e44\u0e14\u0e49\u0e23\u0e31\u0e1a\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e01\u0e32\u0e23\u0e2a\u0e2d\u0e1a\u0e16\u0e32\u0e21\u0e40\u0e01\u0e35\u0e48\u0e22\u0e27\u0e01\u0e31\u0e1a\u0e04\u0e2d\u0e19\u0e42\u0e17\u0e23\u0e25\u0e40\u0e25\u0e2d\u0e23\u0e4c<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Engineering_FAQ\" >\u0e04\u0e33\u0e16\u0e32\u0e21\u0e17\u0e35\u0e48\u0e1e\u0e1a\u0e1a\u0e48\u0e2d\u0e22\u0e40\u0e01\u0e35\u0e48\u0e22\u0e27\u0e01\u0e31\u0e1a\u0e27\u0e34\u0e28\u0e27\u0e01\u0e23\u0e23\u0e21<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Is_RTD_thermal_hysteresis_the_controllers_deadband\" >RTD thermal hysteresis \u0e40\u0e1b\u0e47\u0e19\u0e0a\u0e48\u0e27\u0e07\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19\u0e17\u0e35\u0e48\u0e04\u0e2d\u0e19\u0e42\u0e17\u0e23\u0e25\u0e40\u0e25\u0e2d\u0e23\u0e4c\u0e44\u0e21\u0e48\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e04\u0e27\u0e1a\u0e04\u0e38\u0e21\u0e44\u0e14\u0e49\u0e2b\u0e23\u0e37\u0e2d\u0e44\u0e21\u0e48?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Can_one_ascending_calibration_cover_both_temperature_directions\" >\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e43\u0e0a\u0e49\u0e01\u0e32\u0e23\u0e1b\u0e23\u0e31\u0e1a\u0e41\u0e15\u0e48\u0e07\u0e23\u0e30\u0e14\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e27\u0e31\u0e14\u0e17\u0e35\u0e48\u0e40\u0e1e\u0e34\u0e48\u0e21\u0e02\u0e36\u0e49\u0e19\u0e44\u0e14\u0e49\u0e2b\u0e23\u0e37\u0e2d\u0e44\u0e21\u0e48\u0e40\u0e1e\u0e37\u0e48\u0e2d\u0e04\u0e23\u0e2d\u0e1a\u0e04\u0e25\u0e38\u0e21\u0e17\u0e31\u0e49\u0e07\u0e2a\u0e2d\u0e07\u0e17\u0e34\u0e28\u0e17\u0e32\u0e07\u0e02\u0e2d\u0e07\u0e2d\u0e38\u0e13\u0e2b\u0e20\u0e39\u0e21\u0e34?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Does_averaging_the_two_readings_eliminate_hysteresis\" >Does averaging the two readings eliminate hysteresis?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/th\/news\/rtd-thermal-hysteresis-heating-cooling\/#Do_the_example_readings_establish_TX4-W_accuracy\" >Do the example readings establish TX4-W accuracy?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"ask-whether-the-return-path-changes-the-result\"><span class=\"ez-toc-section\" id=\"Ask_whether_the_return_path_changes_the_result\"><\/span>\u0e16\u0e32\u0e21\u0e14\u0e39\u0e27\u0e48\u0e32\u0e17\u0e32\u0e07\u0e01\u0e25\u0e31\u0e1a\u0e44\u0e1b\u0e19\u0e31\u0e49\u0e19\u0e08\u0e30\u0e40\u0e1b\u0e25\u0e35\u0e48\u0e22\u0e19\u0e1c\u0e25\u0e25\u0e31\u0e1e\u0e18\u0e4c\u0e2b\u0e23\u0e37\u0e2d\u0e44\u0e21\u0e48<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A temperature probe can return to the same reference temperature after a hotter excursion and give a different indication. Repeating only an ascending calibration sequence may therefore leave an operating-history contribution unexamined. The engineering task is to establish whether that contribution matters to the required measurement decision.<\/p>\n<p>For a sensing chain associated with the <a href=\"https:\/\/www.wehopower.com\/th\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\">TX4-W controller reference<\/a>, identify the actual RTD, readout configuration and excursion history. A controller model or nominal Pt100 designation does not establish the hysteresis of the installed probe. The relevant evidence belongs to the particular measurement chain and conditions.<\/p>\n<p>Thermal hysteresis here does not mean an ON\/OFF controller\u2019s switching deadband. It concerns the thermometer\u2019s temperature-resistance relationship after different thermal histories. Keeping those meanings separate prevents a procurement requirement for probe behavior from being answered with an unrelated controller return-value setting.<\/p>\n<p>An acceptance record should state the range over which the probe is conditioned, the comparison temperatures and the intended use. A result after a small excursion cannot silently establish behavior after a much wider one. Nor should an irreversible change after excessive exposure be relabelled ordinary reversible hysteresis without investigation.<\/p>\n<h2 id=\"distinguish-history-dependence-from-other-contributions\"><span class=\"ez-toc-section\" id=\"Distinguish_history_dependence_from_other_contributions\"><\/span>\u0e41\u0e22\u0e01\u0e41\u0e22\u0e30\u0e04\u0e27\u0e32\u0e21\u0e1e\u0e36\u0e48\u0e07\u0e1e\u0e32\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e28\u0e32\u0e2a\u0e15\u0e23\u0e4c\u0e2d\u0e2d\u0e01\u0e08\u0e32\u0e01\u0e01\u0e32\u0e23\u0e21\u0e35\u0e2a\u0e48\u0e27\u0e19\u0e23\u0e48\u0e27\u0e21\u0e2d\u0e37\u0e48\u0e19\u0e46<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a href=\"https:\/\/oar.ptb.de\/files\/download\/681c538853218de84f08e897\" target=\"_blank\" rel=\"noopener\">PTB\u2019s DKD-E 5-1 expert report<\/a>, section 2.2, discusses resistance-thermometer hysteresis as a dependence on thermal history. The report explains that construction and mechanical stresses can influence the effect. Its reported ranges and illustrations are not specifications for an arbitrary probe or a WEHO controller.<\/p>\n<p>This mechanism differs from self-heating, where electrical excitation adds heat to the element. It also differs from an incorrect resistance-to-temperature curve or an unwanted insulation leakage path. Several contributions can coexist, so naming hysteresis does not remove the need to verify the other parts of the measurement boundary.<\/p>\n<p>A sequence that shows rising indications over time is not sufficient to identify hysteresis. The reference source may still be settling, the readout may be drifting, or immersion may have changed. Preserve a stable reference observation and the complete sequence so the apparent path effect can be tested against those alternatives.<\/p>\n<p><a href=\"https:\/\/www.fluke.com\/en-us\/learn\/blog\/temperature-calibration\/dry-well-thermometer-calibrators\" target=\"_blank\" rel=\"noopener\">Fluke\u2019s dry-well performance discussion<\/a> also identifies hysteresis in a calibrator\u2019s internal resistance thermometer. That matters because the source can contribute history-dependent behavior of its own. A stable displayed block setpoint is not automatically an independent reference for the probe under test.<\/p>\n<figure class=\"article-figure product\" data-asset=\"K30-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/th\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\" aria-label=\"TX4-W details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/69cdae9f05db9d05-tx4-w-product-reference.webp\" alt=\"TX4-W product reference preserving the original housing, visible label and connection features.\" width=\"1000\" height=\"1000\" decoding=\"async\" title=\"\"><\/a><figcaption>Product appearance reference for TX4-W, preserving the source housing, visible label and connections. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/33297cd7cf244510-product-original.png\" target=\"_blank\" rel=\"noopener\">\u0e14\u0e39\u0e20\u0e32\u0e1e\u0e43\u0e19\u0e02\u0e19\u0e32\u0e14\u0e15\u0e49\u0e19\u0e09\u0e1a\u0e31\u0e1a<\/a><\/figcaption><\/figure>\n<h2 id=\"calculate-a-hypothetical-two-path-difference\"><span class=\"ez-toc-section\" id=\"Calculate_a_hypothetical_two-path_difference\"><\/span>\u0e04\u0e33\u0e19\u0e27\u0e13\u0e04\u0e27\u0e32\u0e21\u0e41\u0e15\u0e01\u0e15\u0e48\u0e32\u0e07\u0e02\u0e2d\u0e07\u0e40\u0e2a\u0e49\u0e19\u0e17\u0e32\u0e07\u0e2a\u0e2d\u0e07\u0e40\u0e2a\u0e49\u0e19\u0e17\u0e35\u0e48\u0e40\u0e1b\u0e47\u0e19\u0e2a\u0e21\u0e21\u0e15\u0e34<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assume a qualified comparison source and reference establish 100.00\u00b0C under the declared conditions. A probe\/readout chain is observed at that point after approaching from below and again after approaching from above. The following readings are invented to explain the arithmetic; they are not calibration results for TX4-W or a named RTD.<\/p>\n<p>Suppose the ascending-path indication is 100.04\u00b0C and the descending-path indication is 100.16\u00b0C. The indication errors relative to the reference are +0.04 K and +0.16 K. The observed difference between the two path results is 100.16 \u2212 100.04 = 0.12 K.<\/p>\n<p>The midpoint of those indications is (100.04 + 100.16) \u00f7 2 = 100.10\u00b0C. Relative to that midpoint, the observations lie at \u22120.06 K and +0.06 K. These are descriptions of the two assumed observations, not an automatically valid correction or a statistically established uncertainty distribution.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Hypothetical result<\/th>\n<th scope=\"col\" align=\"right\">Indication<\/th>\n<th scope=\"col\" align=\"right\">Error from reference<\/th>\n<th scope=\"col\">Retained meaning<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Reference at comparison point<\/td>\n<td align=\"right\">100.00\u00b0C<\/td>\n<td align=\"right\">Reference basis<\/td>\n<td>Defined source condition<\/td>\n<\/tr>\n<tr>\n<td>Approach from below<\/td>\n<td align=\"right\">100.04\u00b0C<\/td>\n<td align=\"right\">+0.04 K<\/td>\n<td>Ascending-path observation<\/td>\n<\/tr>\n<tr>\n<td>Approach from above<\/td>\n<td align=\"right\">100.16\u00b0C<\/td>\n<td align=\"right\">+0.16 K<\/td>\n<td>Descending-path observation<\/td>\n<\/tr>\n<tr>\n<td>Path difference<\/td>\n<td align=\"right\">0.12 K<\/td>\n<td align=\"right\">Not a new reference error<\/td>\n<td>Difference between observations<\/td>\n<\/tr>\n<tr>\n<td>Midpoint<\/td>\n<td align=\"right\">100.10\u00b0C<\/td>\n<td align=\"right\">+0.10 K<\/td>\n<td>Arithmetic summary only<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Applying a \u22120.10 K correction would center these two observations around the reference, but it would not remove their separation. More importantly, two observations do not establish that the midpoint applies at other temperatures, excursions or service histories. A correction policy needs its own justification and uncertainty treatment.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"K30-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/f74582799ec8e8f2-technical.svg\" alt=\"Hypothetical RTD readings at one reference temperature show the difference between heating and cooling paths.\" width=\"1200\" height=\"675\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. At an assumed 100.00\u00b0C reference, readings of 100.04\u00b0C and 100.16\u00b0C differ by 0.12 K. Their 100.10\u00b0C midpoint does not eliminate path dependence; no WEHO accuracy or correction is assigned. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/f74582799ec8e8f2-technical.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>A project could have different dispositions for the two path results under its declared acceptance rule. For example, a narrow allowable indication error could include one observation and exclude the other. State that rule before testing and include measurement uncertainty rather than selecting whichever approach direction gives the preferred result.<\/p>\n<h2 id=\"design-a-history-controlled-comparison\"><span class=\"ez-toc-section\" id=\"Design_a_history-controlled_comparison\"><\/span>\u0e2d\u0e2d\u0e01\u0e41\u0e1a\u0e1a\u0e01\u0e32\u0e23\u0e40\u0e1b\u0e23\u0e35\u0e22\u0e1a\u0e40\u0e17\u0e35\u0e22\u0e1a\u0e17\u0e35\u0e48\u0e21\u0e35\u0e01\u0e32\u0e23\u0e04\u0e27\u0e1a\u0e04\u0e38\u0e21\u0e14\u0e49\u0e27\u0e22\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e28\u0e32\u0e2a\u0e15\u0e23\u0e4c<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Record the conditioning endpoints, direction, dwell criteria and actual sequence. Use endpoint conditions suitable for the probe, source and intended service. Do not deliberately exceed a probe\u2019s limits to force a larger effect; such exposure can damage the sensor and invalidate the intended comparison.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Record element<\/th>\n<th scope=\"col\">Why it matters<\/th>\n<th scope=\"col\">Control to retain<\/th>\n<th scope=\"col\">Interpretation limit<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Prior temperature excursion<\/td>\n<td>Establishes history<\/td>\n<td>Actual endpoints and sequence<\/td>\n<td>Smaller range may not cover service<\/td>\n<\/tr>\n<tr>\n<td>Comparison condition<\/td>\n<td>Establishes common point<\/td>\n<td>Reference, stability and location<\/td>\n<td>Displayed setpoint alone is insufficient<\/td>\n<\/tr>\n<tr>\n<td>Measurement chain<\/td>\n<td>Identifies observed system<\/td>\n<td>Probe, leads, readout and configuration<\/td>\n<td>Does not isolate probe automatically<\/td>\n<\/tr>\n<tr>\n<td>Repetition and timing<\/td>\n<td>Tests consistency<\/td>\n<td>Raw values and timestamps<\/td>\n<td>Two points do not prove a population bound<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Use the same immersion and mechanical arrangement at each comparison where the method requires it. Moving a sensor to a different position can change heat flow or the source gradient. If repositioning is unavoidable, record the change and evaluate its contribution rather than burying it in a reported hysteresis number.<\/p>\n<p>A practical study may repeat ascending and descending sequences or include intermediate checks. The exact plan belongs to the relevant calibration method and intended claim. Do not infer a universal cycle count, endpoint temperature or allowable hysteresis from the simple example in this article.<\/p>\n<p>If a probe\u2019s readings continue to move after each cycle instead of forming a repeatable relationship, preserve that evidence separately. Continuing drift, mechanical damage or another instability may require investigation. A single average can obscure whether the system is repeatable enough for the proposed correction or release method.<\/p>\n<h2 id=\"verify-and-release-the-relevant-measurement-use\"><span class=\"ez-toc-section\" id=\"Verify_and_release_the_relevant_measurement_use\"><\/span>\u0e15\u0e23\u0e27\u0e08\u0e2a\u0e2d\u0e1a\u0e41\u0e25\u0e30\u0e1b\u0e25\u0e48\u0e2d\u0e22\u0e01\u0e32\u0e23\u0e43\u0e0a\u0e49\u0e07\u0e32\u0e19\u0e04\u0e48\u0e32\u0e01\u0e32\u0e23\u0e27\u0e31\u0e14\u0e17\u0e35\u0e48\u0e40\u0e01\u0e35\u0e48\u0e22\u0e27\u0e02\u0e49\u0e2d\u0e07<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Define the service history.<\/strong> Record the intended temperature range, relevant excursions and required measurement limits. Verify that the proposed study represents those conditions without exceeding component limits.<\/li>\n<li><strong>Establish the comparison boundary.<\/strong> Identify probe, leads, readout and source\/reference method. Record configuration and uncertainty contributions; verify that source changes can be distinguished from the chain under test.<\/li>\n<li><strong>Preserve the approach direction.<\/strong> Follow the defined conditioning and stabilization sequence. Record each raw indication and reference value with direction and time, verifying that opposite-path observations describe comparable reference conditions.<\/li>\n<li><strong>Evaluate the declared quantities.<\/strong> Calculate path differences, errors and any permitted summaries. Verify the acceptance and uncertainty treatment against the actual method rather than assigning an unsupported distribution to a two-point range.<\/li>\n<li><strong>Document the approved use.<\/strong> Retain the applicable history, correction policy and conditions requiring reassessment. Verify the affected chain after probe replacement, excessive exposure or a relevant configuration change.<\/li>\n<\/ol>\n<p>The study is a measurement qualification, not an instruction to alter controller settings until both paths appear identical. Preserve existing correction values and raw results. A changed input correction can hide one offset while leaving the underlying path dependence and other errors unchanged.<\/p>\n<p>Where the temperature measurement influences a protective function, keep that equipment assessment separate from ordinary process indication. The responsible engineering team determines whether the complete sensing and protective arrangement is suitable. This calculation does not establish functional-safety performance or authorize bypassing an interlock.<\/p>\n<h2 id=\"give-weho-the-history-with-the-controller-enquiry\"><span class=\"ez-toc-section\" id=\"Give_WEHO_the_history_with_the_controller_enquiry\"><\/span>\u0e43\u0e2b\u0e49 WEHO \u0e44\u0e14\u0e49\u0e23\u0e31\u0e1a\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e01\u0e32\u0e23\u0e2a\u0e2d\u0e1a\u0e16\u0e32\u0e21\u0e40\u0e01\u0e35\u0e48\u0e22\u0e27\u0e01\u0e31\u0e1a\u0e04\u0e2d\u0e19\u0e42\u0e17\u0e23\u0e25\u0e40\u0e25\u0e2d\u0e23\u0e4c<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>\u0e2a\u0e33\u0e2b\u0e23\u0e31\u0e1a\u0e2b\u0e19\u0e36\u0e48\u0e07 <a href=\"https:\/\/www.wehopower.com\/th\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\">TX4-W measurement-chain discussion<\/a>, include the full controller and RTD identities, configuration, excursion history and paired reference readings. State whether the question concerns controller indication, probe calibration or the installed chain. Request applicable documentation without assuming a calibration service or probe-specific guarantee is available.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>\u0e04\u0e33\u0e16\u0e32\u0e21\u0e17\u0e35\u0e48\u0e1e\u0e1a\u0e1a\u0e48\u0e2d\u0e22\u0e40\u0e01\u0e35\u0e48\u0e22\u0e27\u0e01\u0e31\u0e1a\u0e27\u0e34\u0e28\u0e27\u0e01\u0e23\u0e23\u0e21<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"is-rtd-thermal-hysteresis-the-controller-s-deadband\"><span class=\"ez-toc-section\" id=\"Is_RTD_thermal_hysteresis_the_controllers_deadband\"><\/span>RTD thermal hysteresis \u0e40\u0e1b\u0e47\u0e19\u0e0a\u0e48\u0e27\u0e07\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19\u0e17\u0e35\u0e48\u0e04\u0e2d\u0e19\u0e42\u0e17\u0e23\u0e25\u0e40\u0e25\u0e2d\u0e23\u0e4c\u0e44\u0e21\u0e48\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e04\u0e27\u0e1a\u0e04\u0e38\u0e21\u0e44\u0e14\u0e49\u0e2b\u0e23\u0e37\u0e2d\u0e44\u0e21\u0e48?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Thermal hysteresis concerns history-dependent thermometer behavior at a reference temperature. Controller switching deadband concerns the separation of control transitions; their units may resemble each other while their meanings differ.<\/p>\n<h3 id=\"can-one-ascending-calibration-cover-both-temperature-directions\"><span class=\"ez-toc-section\" id=\"Can_one_ascending_calibration_cover_both_temperature_directions\"><\/span>\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e43\u0e0a\u0e49\u0e01\u0e32\u0e23\u0e1b\u0e23\u0e31\u0e1a\u0e41\u0e15\u0e48\u0e07\u0e23\u0e30\u0e14\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e27\u0e31\u0e14\u0e17\u0e35\u0e48\u0e40\u0e1e\u0e34\u0e48\u0e21\u0e02\u0e36\u0e49\u0e19\u0e44\u0e14\u0e49\u0e2b\u0e23\u0e37\u0e2d\u0e44\u0e21\u0e48\u0e40\u0e1e\u0e37\u0e48\u0e2d\u0e04\u0e23\u0e2d\u0e1a\u0e04\u0e25\u0e38\u0e21\u0e17\u0e31\u0e49\u0e07\u0e2a\u0e2d\u0e07\u0e17\u0e34\u0e28\u0e17\u0e32\u0e07\u0e02\u0e2d\u0e07\u0e2d\u0e38\u0e13\u0e2b\u0e20\u0e39\u0e21\u0e34?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Only when its applicability to the required service is established. A single direction does not itself quantify the effect of returning from a hotter condition, so preserve the relevant conditioning history.<\/p>\n<h3 id=\"does-averaging-the-two-readings-eliminate-hysteresis\"><span class=\"ez-toc-section\" id=\"Does_averaging_the_two_readings_eliminate_hysteresis\"><\/span>Does averaging the two readings eliminate hysteresis?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. It produces a numerical midpoint while the path difference remains. Any correction and uncertainty treatment require a justified method for the actual intended use.<\/p>\n<h3 id=\"do-the-example-readings-establish-tx4-w-accuracy\"><span class=\"ez-toc-section\" id=\"Do_the_example_readings_establish_TX4-W_accuracy\"><\/span>Do the example readings establish TX4-W accuracy?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. They are hypothetical observations selected to show a path difference. Controller accuracy and probe behavior require their own applicable documentation and actual measurement evidence.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u0e40\u0e1b\u0e23\u0e35\u0e22\u0e1a\u0e40\u0e17\u0e35\u0e22\u0e1a\u0e04\u0e48\u0e32\u0e01\u0e32\u0e23\u0e27\u0e31\u0e14\u0e02\u0e2d\u0e07 RTD \u0e2b\u0e25\u0e31\u0e07\u0e08\u0e32\u0e01\u0e1b\u0e23\u0e30\u0e27\u0e31\u0e15\u0e34\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19\u0e17\u0e35\u0e48\u0e41\u0e15\u0e01\u0e15\u0e48\u0e32\u0e07\u0e01\u0e31\u0e19 \u0e42\u0e14\u0e22\u0e23\u0e31\u0e01\u0e29\u0e32\u0e04\u0e27\u0e32\u0e21\u0e41\u0e15\u0e01\u0e15\u0e48\u0e32\u0e07\u0e02\u0e2d\u0e07\u0e41\u0e2b\u0e25\u0e48\u0e07\u0e01\u0e33\u0e40\u0e19\u0e34\u0e14\u0e41\u0e25\u0e30\u0e40\u0e2a\u0e49\u0e19\u0e17\u0e32\u0e07\u0e44\u0e27\u0e49 \u0e08\u0e32\u0e01\u0e19\u0e31\u0e49\u0e19\u0e2a\u0e48\u0e07\u0e1a\u0e31\u0e19\u0e17\u0e36\u0e01\u0e01\u0e32\u0e23\u0e27\u0e31\u0e14\u0e02\u0e2d\u0e07 TX4-W \u0e02\u0e2d\u0e07\u0e04\u0e38\u0e13\u0e44\u0e1b\u0e22\u0e31\u0e07 WEHO.<\/p>","protected":false},"author":2,"featured_media":22218,"parent":0,"menu_order":2,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-24741","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/news\/24741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/comments?post=24741"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/news\/24741\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/media\/22218"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/media?parent=24741"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/th\/wp-json\/wp\/v2\/news_category?post=24741"}],"curies":[{"name":"\u0e2b\u0e19\u0e49\u0e32","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}