{"id":22265,"date":"2026-11-17T10:51:12","date_gmt":"2026-11-17T02:51:12","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/passive-probe-compensation-supply-overshoot\/"},"modified":"2026-11-17T10:51:12","modified_gmt":"2026-11-17T02:51:12","slug":"passive-probe-compensation-supply-overshoot","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/","title":{"rendered":"Passive Probe Compensation: Check Apparent Supply Overshoot"},"content":{"rendered":"<div class=\"weho-blog\">\n<p>Verify the passive probe and oscilloscope channel together before assigning a rounded edge or apparent overshoot to a power supply. An incorrectly compensated divider can distort the displayed transition even when the applied voltage has no overshoot.<\/p>\n<p><strong>Key engineering takeaways<\/strong><\/p>\n<ul>\n<li>Match the probe&#39;s compensation range to the actual channel.<\/li>\n<li>Keep compensation, attenuation scaling and calibration distinct.<\/li>\n<li>Check a suitable reference before interpreting a DUT transition.<\/li>\n<li>Preserve the original capture and the corrected measurement setup.<\/li>\n<\/ul>\n<figure class=\"article-figure hero\" data-asset=\"H08-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/tl\/product\/lrs-series-400w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"LRS-400-24 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/3c057ec44cefc101-lrs-400-24-application.avif\" alt=\"Passive Probe Compensation: Check Apparent Supply Overshoot  title=\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" passive probe compensation: check apparent supply overshoot title =\"\"><\/a><figcaption>LRS-400-24 in an application illustration, not a customer installation photo. Scene created with AI assistance. The image does not establish probe compensation or measured overshoot. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/37fc252f0794f33d-application-master.webp\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#which-part-of-the-measurement-might-create-the-shape\">Which part of the measurement might create the shape?<\/a><\/li>\n<li><a href=\"#why-does-an-attenuating-passive-probe-need-compensation\">Why does an attenuating passive probe need compensation?<\/a><\/li>\n<li><a href=\"#a-simplified-divider-can-produce-a-false-peak\">A simplified divider can produce a false peak<\/a><\/li>\n<li><a href=\"#what-does-the-reference-check-establish\">What does the reference check establish?<\/a><\/li>\n<li><a href=\"#verify-record-and-repeat-the-intended-event\">Verify, record and repeat the intended event<\/a><\/li>\n<li><a href=\"#prepare-an-lrs-400-24-transient-enquiry\">Prepare an LRS-400-24 transient enquiry<\/a><\/li>\n<li><a href=\"#engineering-faq\">Engineering FAQ<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Talaan ng mga Nilalaman<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">I-toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#Which_part_of_the_measurement_might_create_the_shape\" >Which part of the measurement might create the shape?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#Why_does_an_attenuating_passive_probe_need_compensation\" >Why does an attenuating passive probe need compensation?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#A_simplified_divider_can_produce_a_false_peak\" >A simplified divider can produce a false peak<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#What_does_the_reference_check_establish\" >What does the reference check establish?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#Verify_record_and_repeat_the_intended_event\" >Verify, record and repeat the intended event<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#Prepare_an_LRS-400-24_transient_enquiry\" >Prepare an LRS-400-24 transient enquiry<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#Engineering_FAQ\" >Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#Does_a_correct_attenuation_ratio_mean_the_probe_is_compensated\" >Does a correct attenuation ratio mean the probe is compensated?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#Can_probe_compensation_remove_genuine_power-supply_overshoot\" >Can probe compensation remove genuine power-supply overshoot?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#Is_a_flat_reference_waveform_a_complete_calibration_certificate\" >Is a flat reference waveform a complete calibration certificate?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/tl\/news\/passive-probe-compensation-supply-overshoot\/#Are_the_models_818_excess_and_capacitances_WEHO_specifications\" >Are the model&#39;s 81.8% excess and capacitances WEHO specifications?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"which-part-of-the-measurement-might-create-the-shape\"><span class=\"ez-toc-section\" id=\"Which_part_of_the_measurement_might_create_the_shape\"><\/span>Which part of the measurement might create the shape?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An OEM validation engineer needs to decide whether an unexpected peak belongs to the equipment or to its measurement chain. The observation should first be recorded as a displayed waveform. Calling the first peak \u201cpower supply overshoot\u201d assigns a cause before the probe, channel and reference have been checked.<\/p>\n<p>For an <a href=\"https:\/\/www.wehopower.com\/tl\/product\/lrs-series-400w-ac-to-dc-single-output-switching-power-supply\/\">LRS-400-24 waveform review<\/a>, retain the full supply identity, operating state and actual voltage node. The product photograph identifies the candidate supply. It does not establish the waveform, the installed harness response or the suitability of a particular probe.<\/p>\n<p>Compensation concerns the probe-channel response, while the equipment&#39;s permitted voltage excursion concerns the actual electrical event. Correcting the instrument setup is therefore part of obtaining usable evidence, not permission to relax a receiver limit. The original questionable record should remain available with the reason it was superseded.<\/p>\n<h2 id=\"why-does-an-attenuating-passive-probe-need-compensation\"><span class=\"ez-toc-section\" id=\"Why_does_an_attenuating_passive_probe_need_compensation\"><\/span>Why does an attenuating passive probe need compensation?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A simple attenuating probe combines resistive and capacitive paths. Their relative division should agree over the frequency range for which the system is intended. A mismatch can make the displayed edge lead or lag its eventual plateau, changing both apparent amplitude and shape.<\/p>\n<p><a href=\"https:\/\/www.ni.com\/en\/shop\/electronic-test-instrumentation\/oscilloscopes\/what-are-oscilloscopes\/select-the-right-oscilloscope-probe-for-your-application.html\" target=\"_blank\" rel=\"noopener\">NI&#39;s probe-selection guidance<\/a> explains the importance of resistance, capacitance and bandwidth, including individual probe-channel compensation. Check the actual combination rather than assuming that a probe remains correctly adjusted after moving it to another channel or instrument.<\/p>\n<p>Compensation is also different from entering the attenuation ratio in the channel menu. A wrong ratio can scale all reported voltages incorrectly. A correct ratio does not flatten an incorrectly compensated response, and a flat reference does not establish that the numerical attenuation setting is correct.<\/p>\n<h2 id=\"a-simplified-divider-can-produce-a-false-peak\"><span class=\"ez-toc-section\" id=\"A_simplified_divider_can_produce_a_false_peak\"><\/span>A simplified divider can produce a false peak<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Consider a <strong>hypothetical lumped divider<\/strong>, not the internal design of a commercial probe. Let its upper arm be Rp = 9 M\u03a9 in parallel with Cp, and its lower arm be Rs = 1 M\u03a9 in parallel with Cs = 100 pF. Assume an ideal zero-impedance source, a unit voltage step and no other circuit elements.<\/p>\n<p>The model&#39;s DC transfer is Rs\/(Rp + Rs) = 0.1. Assume the displayed value multiplies the divider output by ten, so the final indicated level is 1.000 V for the 1 V input. Frequency-independent division in this model requires Rp \u00d7 Cp = Rs \u00d7 Cs, giving Cp = 11.111 pF, rounded.<\/p>\n<p>For the ideal step&#39;s initial capacitive division, the raw ratio is Cp\/(Cp + Cs). The scaled initial indication is therefore 10 \u00d7 Cp\/(Cp + Cs). A capacitance that is too large makes this initial value exceed the final level; a capacitance that is too small makes the initial value fall below it.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Assumed Cp<\/th>\n<th scope=\"col\">Upper-arm RC<\/th>\n<th scope=\"col\">Scaled initial indication<\/th>\n<th scope=\"col\">Final indication<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>5.556 pF, rounded<\/td>\n<td>50 \u00b5s<\/td>\n<td>0.526 V<\/td>\n<td>1.000 V<\/td>\n<\/tr>\n<tr>\n<td>11.111 pF, rounded<\/td>\n<td>100 \u00b5s<\/td>\n<td>1.000 V<\/td>\n<td>1.000 V<\/td>\n<\/tr>\n<tr>\n<td>22.222 pF, rounded<\/td>\n<td>200 \u00b5s<\/td>\n<td>1.818 V<\/td>\n<td>1.000 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure class=\"article-figure technical\" data-asset=\"H08-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/1c16448d933b9264-passive-probe-compensation-model.svg\" alt=\"Passive Probe Compensation: Check Apparent Supply Overshoot  title=\" width=\"1200\" height=\"675\" decoding=\"async\" passive probe compensation: check apparent supply overshoot title =\"\"><\/div><figcaption>Conceptual Engineering Diagram. Calculated unit-step responses of an ideal lumped divider; not a commercial probe model, WEHO waveform or test result. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/1c16448d933b9264-passive-probe-compensation-model.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>The input in every row is the same ideal 1 V step. The last row&#39;s apparent excess is 1.818 \u2212 1.000 = 0.818 V, approximately 81.8% of the final level. That exaggerated result demonstrates the assumed divider mismatch; it is not a plausible-error guarantee or an LRS-400-24 test result.<\/p>\n<p>For this model, the indicated step is 1 + (A0 \u2212 1) \u00d7 exp(\u2212t\/\u03c4), where A0 is the scaled initial value and \u03c4 = (Rp \u00d7 Rs\/(Rp + Rs)) \u00d7 (Cp + Cs). The three settling constants are 95, 100 and 110 \u00b5s respectively. With matched arms, the exponential coefficient is zero, so the idealized response is flat.<\/p>\n<p>The model deliberately omits distributed cable behavior, inductance, source impedance, finite rise time and bandwidth limits. Its calculation explains a causal mechanism, not a procedure for constructing or modifying a probe. Real limits and adjustment methods come from the actual probe and oscilloscope documentation.<\/p>\n<h2 id=\"what-does-the-reference-check-establish\"><span class=\"ez-toc-section\" id=\"What_does_the_reference_check_establish\"><\/span>What does the reference check establish?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The <a href=\"https:\/\/download.tek.com\/manual\/070551703.pdf\" target=\"_blank\" rel=\"noopener\">Tektronix P6106A instructions<\/a> describe checking compensation before critical amplitude or rise-time work, and show undercompensated, overcompensated and appropriately adjusted reference responses. Their instrument-specific adjustments are not universal commands for every probe. Use the instructions and suitable reference for the installed equipment.<\/p>\n<p>A reference check tests a defined response under its own conditions. It does not independently establish every bandwidth, voltage, loading or calibration property of the complete measurement chain. Record the reference source and the settings used, including the probe attenuation mode and the oscilloscope input configuration.<\/p>\n<p><a href=\"https:\/\/www.keysight.com\/so\/en\/assets\/9018-07558\/user-manuals\/9018-07558.pdf\" target=\"_blank\" rel=\"noopener\">Keysight&#39;s passive-probe user guide<\/a> provides another manufacturer&#39;s example of matching a passive probe to an input channel. A probe whose compensation range cannot accommodate that channel should not be accepted merely because the trimmer has reached an endpoint. Resolve compatibility against the specified equipment combination.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Observation<\/th>\n<th scope=\"col\">What it supports<\/th>\n<th scope=\"col\">What remains separate<\/th>\n<th scope=\"col\">Record needed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Reference top changes after compensation<\/td>\n<td>Probe-channel adjustment affected the displayed response<\/td>\n<td>Actual DUT voltage behavior<\/td>\n<td>Before\/after reference and configuration<\/td>\n<\/tr>\n<tr>\n<td>Voltage changes by a constant scale factor<\/td>\n<td>Attenuation configuration needs checking<\/td>\n<td>Frequency-response compensation<\/td>\n<td>Hardware mode and channel scaling<\/td>\n<\/tr>\n<tr>\n<td>Ringing changes with the return connection<\/td>\n<td>Measurement-loop effects need investigation<\/td>\n<td>RC compensation and DUT behavior<\/td>\n<td>Connection arrangement and comparable traces<\/td>\n<\/tr>\n<tr>\n<td>Adjusted reference is acceptable<\/td>\n<td>The documented reference check passed<\/td>\n<td>All other instrument and DUT acceptance requirements<\/td>\n<td>Applicable criterion and its measured scope<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Do not collapse every distorted edge into the same diagnosis. Ground-path inductance, probe loading, bandwidth and a real electrical transient can coexist with compensation error. Establish the connection and energy-reference requirements before attaching instruments; compensation cannot make an otherwise unsuitable ground connection acceptable.<\/p>\n<p>This article addresses divider response after a suitable measurement arrangement has been selected. Connection planning and compensation remain separate decisions.<\/p>\n<h2 id=\"verify-record-and-repeat-the-intended-event\"><span class=\"ez-toc-section\" id=\"Verify_record_and_repeat_the_intended_event\"><\/span>Verify, record and repeat the intended event<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Identify the complete combination.<\/strong> Record probe, attenuation mode, oscilloscope, channel, input impedance and applicable instructions. Verify the allowed combination, ratings and compensation range before accepting the setup for the intended node.<\/li>\n<li><strong>Preserve the starting evidence.<\/strong> Save the original reference and DUT captures with their settings and operating states. Verify that filenames and timestamps distinguish an initial questionable trace from a later corrected measurement.<\/li>\n<li><strong>Check the documented reference.<\/strong> Qualified personnel should follow the equipment&#39;s reference and adjustment procedure. Record the observed response and criterion; verify that the setting is supported rather than merely adjusted until an attractive waveform appears.<\/li>\n<li><strong>Repeat the DUT event.<\/strong> Keep the relevant load, input, trigger, node and acquisition conditions comparable. Record the repeated result separately, and verify that a changed operating state has not been mistaken for an instrumentation improvement.<\/li>\n<li><strong>Apply the real acceptance rule.<\/strong> Evaluate the valid waveform against the equipment&#39;s documented voltage-versus-time requirement. Hold a conclusion when the instrument response or event repeatability remains unresolved; retain the reason with the review record.<\/li>\n<\/ol>\n<figure class=\"article-figure product\" data-asset=\"H08-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/tl\/product\/lrs-series-400w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"LRS-400-24 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/0f29ed8b4c6b5ff9-lrs-400-24-product-reference.avif\" alt=\"Passive Probe Compensation: Check Apparent Supply Overshoot  title=\" width=\"1000\" height=\"1000\" decoding=\"async\" passive probe compensation: check apparent supply overshoot title =\"\"><\/a><figcaption>WEHO LRS-400-24 product identification reference, retaining the source image&#8217;s visible identity. The photograph does not establish probe compensation or measured overshoot. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/44622179442b7304-product-original.jpg\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"prepare-an-lrs-400-24-transient-enquiry\"><span class=\"ez-toc-section\" id=\"Prepare_an_LRS-400-24_transient_enquiry\"><\/span>Prepare an LRS-400-24 transient enquiry<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Send WEHO the <a href=\"https:\/\/www.wehopower.com\/tl\/product\/lrs-series-400w-ac-to-dc-single-output-switching-power-supply\/\">LRS-400-24 candidate identity<\/a>, actual load event, permitted receiver voltage and the appropriately acquired trace. Include the probe-channel reference record when measurement distortion is part of the question. Do not send only a cropped peak with no configuration or operating context.<\/p>\n<p>Complete the probe-channel check, preserve both versions and repeat the intended event before assigning the cause. If the valid measurement still exceeds the equipment requirement, investigate that actual event through the responsible engineering process. A corrected instrument trace is evidence to interpret, not an automatic product approval.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"does-a-correct-attenuation-ratio-mean-the-probe-is-compensated\"><span class=\"ez-toc-section\" id=\"Does_a_correct_attenuation_ratio_mean_the_probe_is_compensated\"><\/span>Does a correct attenuation ratio mean the probe is compensated?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Attenuation scaling and frequency-response compensation are separate settings. Check the hardware mode, channel scaling and documented reference response together, because a numerically correct scale can still display a distorted transition.<\/p>\n<h3 id=\"can-probe-compensation-remove-genuine-power-supply-overshoot\"><span class=\"ez-toc-section\" id=\"Can_probe_compensation_remove_genuine_power-supply_overshoot\"><\/span>Can probe compensation remove genuine power-supply overshoot?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Compensation adjusts the measurement chain rather than the supply. It can remove a measurement artifact, but a validly measured excursion still needs comparison with the receiver requirement and investigation under the actual operating conditions.<\/p>\n<h3 id=\"is-a-flat-reference-waveform-a-complete-calibration-certificate\"><span class=\"ez-toc-section\" id=\"Is_a_flat_reference_waveform_a_complete_calibration_certificate\"><\/span>Is a flat reference waveform a complete calibration certificate?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. A reference compensation check has a defined scope and does not replace the instrument&#39;s applicable calibration or verification requirements. Preserve the reference conditions and identify what was actually checked instead of assigning unrestricted accuracy to the system.<\/p>\n<h3 id=\"are-the-model-s-81-8-excess-and-capacitances-weho-specifications\"><span class=\"ez-toc-section\" id=\"Are_the_models_818_excess_and_capacitances_WEHO_specifications\"><\/span>Are the model&#39;s 81.8% excess and capacitances WEHO specifications?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. They are deliberately exaggerated assumptions in an ideal divider example. The values explain how a capacitive mismatch can alter an indicated edge and must not be attributed to an LRS-400-24, a real commercial probe or a completed test.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Verify passive probe compensation before interpreting apparent supply overshoot. Send WEHO the LRS-400-24 event, reference check and receiver limit.<\/p>","protected":false},"author":2,"featured_media":22243,"parent":0,"menu_order":11,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-22265","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/tl\/wp-json\/wp\/v2\/news\/22265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/tl\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/tl\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tl\/wp-json\/wp\/v2\/comments?post=22265"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/tl\/wp-json\/wp\/v2\/news\/22265\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tl\/wp-json\/wp\/v2\/media\/22243"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/tl\/wp-json\/wp\/v2\/media?parent=22265"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/tl\/wp-json\/wp\/v2\/news_category?post=22265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}