...

Product Categories

LRH-350 380VAC Input Voltage AC to DC Switching Power Supply

LRH-350 representative shown

LRH-350 · 350 W Class Enclosed Power Supply

380 V AC input class (300–450 V AC). Choose the DC output voltage that matches your load.

Çıkış voltajı
Modeli
LRH-350-12LRH-350-15LRH-350-24LRH-350-48
DC output
12 V · 0–29 A15 V · 0–23.2 A24 V · 0–14.6 A48 V · 0–7.3 A
AC input
300–450 V AC
DC input
420–635 V DC
Yeterlik
85%86%88%89%
Dimensions (L × W × H)
215 × 115 × 30 mm

Specifications & models

ParameterLRH-350-12LRH-350-15LRH-350-24LRH-350-48
DC output voltage and current12 V · 0–29 A15 V · 0–23.2 A24 V · 0–14.6 A48 V · 0–7.3 A
Giriş voltajı aralığı300–450 V AC, 47–63 Hz / 420–635 V DC
Boyutlar215 × 115 × 30 mm
Yeterlik85%86%88%89%
Çalışma sıcaklığı−20 to +70 °C; full-load operation across this range is not specified.
Ripple & noise150 mVp-p150 mVp-p150 mVp-p200 mVp-p
Hat düzenlemesi±0,5%
Yük düzenlemesi±0,5%
Çıkış voltajı ayarı±10%
Ani akımCold start 60 A max (consult WEHO for 380 V AC surge profile)
Aşırı yük koruması110–150%: output cuts off and recovers automatically.
Aşırı gerilim korumasıConsult WEHO for the overvoltage protection setpoint.
Timing (setup / rise / hold-up)Setup 1500 ms, rise 50 ms typical (confirm under 380 V AC operating load)
Voltaja dayanmakInput–output 1.5 kV; input–frame 1.5 kV; output–frame 0.5 kV, 1 minute.
Yalıtım direnci100 MΩ at 500 V DC, 25 °C and 70% RH (input–output, input–frame and output–frame).
Ağırlık0.76 kg
Ambalaj37.5 × 25 × 26 cm / 20 pcs / 16 kg
Output options
ÇıktıAkımYeterlikDalgalanma (mVp-p)
12 V0–29 A85%150
15 V0–23.2 A86%150
24 V0–14.6 A88%150
48 V0–7.3 A89%200
Common specifications
Giriş voltajı aralığı300–450 V AC, 47–63 Hz / 420–635 V DC
Boyutlar215 × 115 × 30 mm
Çalışma sıcaklığı−20 to +70 °C; full-load operation across this range is not specified.
Hat düzenlemesi±0,5%
Yük düzenlemesi±0,5%
Çıkış voltajı ayarı±10%
Ani akımCold start 60 A max (consult WEHO for 380 V AC surge profile)
Aşırı yük koruması110–150%: output cuts off and recovers automatically.
Aşırı gerilim korumasıConsult WEHO for the overvoltage protection setpoint.
Timing (setup / rise / hold-up)Setup 1500 ms, rise 50 ms typical (confirm under 380 V AC operating load)
Voltaja dayanmakInput–output 1.5 kV; input–frame 1.5 kV; output–frame 0.5 kV, 1 minute.
Yalıtım direnci100 MΩ at 500 V DC, 25 °C and 70% RH (input–output, input–frame and output–frame).
Ağırlık0.76 kg
Ambalaj37.5 × 25 × 26 cm / 20 pcs / 16 kg

Dimensions & load conditions

Mechanical dimensions

215 × 115 × 30 mm (L × W × H)

Wide face
Narrow face

Drawing dimensions are in millimetres. Verify terminal markings on the unit before installation.

Installed load and temperature

The operating range is −20 to +70 °C. A load-versus-temperature curve for this model is not supplied here. Confirm the permissible load at your actual cabinet temperature.

Product overview

For a multi-device control cabinet, compare the LRH-350-24 version (24 V · 0–14.6 A) with the total DC demand, including start-up. The 215 × 115 × 30 mm figure is the enclosure size, not the full service clearance.

Design features

ÖzellikWhat to check
Output trimUse the ±10% adjustment to fine-tune the rail within the load’s voltage limits.
Low-profile caseAllow space beyond the housing for airflow, wiring bends and access to the terminals.
Overload recoveryThe output cuts off during overload and recovers automatically. Check how the equipment restarts.

Installation & applications

Installation checks

Verify the input

Check 300–450 V AC at 47–63 Hz / 420–635 V DC at the installation point.

Reserve service clearance

Allow for the 215 × 115 × 30 mm enclosure, terminal access and cable bends.

Measure cabinet temperature

Check the temperature near the supply during the longest duty cycle.

Check restart behaviour

Assess what the connected equipment does when DC power returns.

Application examples

Size the supply for the auxiliary electronics, not for the whole machine.

Operator controls on a 5-axis CNC machining center

The HMI screen and tactile pushbuttons are examples of low-voltage loads to check when sizing a 380 V AC auxiliary supply for an operator station. The spindle drive is a separate load.

Sensor and interlock rails in a robotic automation cell

Size the 380 V AC-input auxiliary supply for safety light curtains, optical sensors and I/O modules—not for the robotic arm servo drives.

Optical metrology and machine-vision inspection stations

Account separately for the machine-vision camera, coaxial ring light and linear-stage controller loads when sizing the 380 V AC auxiliary supply.

AI-generated application illustrations for selection planning; not photographs of verified installations.

Frequently asked questions

LRH-350: 12 V     0–29 A; 15 V     0–23.2 A; 24 V     0–14.6 A; 48 V     0–7.3 A
One output voltage per supply.
Which output should I select?

Each voltage is a separate version. 12 V, 15 V, 24 V, 48 V are listed.

What must I check at the input?

300–450 V AC, 47–63 Hz / 420–635 V DC

Is the highest temperature a full-load rating?

No full-load limit at that temperature is established here. Ask for the permitted load in your mounting conditions.

What should I include in a quote request?

Include LRH-350, desired output, continuous and start-up current, quantity and destination.

Request a quote

Use the theme inquiry form on this product page. Selected model: LRH-350-12LRH-350-15LRH-350-24LRH-350-48.

LRH-350 representative product photograph
LRH-350 representative shown

Send an inquiry

LRH-350 datasheet

Close
Download PDF
LRH-350 datasheet, page 1 of 1

LRH-350 representative shownEnlarge view

LRH-350 representative product photograph

Wide face

LRH-350 wide face with mounting dimensions in millimetres

Narrow face

LRH-350 side face with mounting dimensions in millimetres

Operator controls on a 5-axis CNC machining center

A modern 5-axis CNC machining center in a bright smart factory hall with an articulated brushed-aluminum HMI operator console and pushbuttons.

Sensor and interlock rails in a robotic automation cell

Two white-and-graphite 6-axis industrial robotic arms inside a glass-walled smart factory automation cell with precision pallet transfer tracks and optical safety light curtains.

Optical metrology and machine-vision inspection stations

A precision automated optical metrology and machine-vision inspection station with a brushed-aluminum gantry and LED coaxial ring light inspecting a machined stainless-steel flange on a granite rotary stage.

İşletmeniz için en iyi Güç Kaynağı ürünleri nelerdir?

WEHO kalitesindeki güç kaynağı ürünleriyle işinizi güçlendirin.

Bir Uzmana Sorun
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.