{"id":20230,"date":"2026-10-28T14:20:49","date_gmt":"2026-10-28T06:20:49","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/smps-output-lc-filter-stability-load-step\/"},"modified":"2026-10-28T14:20:49","modified_gmt":"2026-10-28T06:20:49","slug":"smps-output-lc-filter-stability-load-step","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/tr\/news\/smps-output-lc-filter-stability-load-step\/","title":{"rendered":"Adding an LC Output Filter to an SMPS: Check Ringing, Sensing and Load Steps"},"content":{"rendered":"<div class=\"weho-geo-content weho-geo01\">\n<p class=\"lead\"><strong>An external LC filter can reduce differential-mode switching ripple at a load, but the added network must be checked with the power supply and load together.<\/strong> Confirm that the exact supply permits the proposed output network and feedback connection. Then compare startup, load-step behavior and ripple at both the supply terminals and the load. A cleaner steady-state waveform alone is insufficient to accept the change.<\/p>\n<figure id=\"figure-product-hero\" class=\"product-hero\">\n  <a class=\"hero-image-link\" href=\"https:\/\/www.wehopower.com\/product\/lrs-series-350w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"View WEHO LRS-350-36 product details\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/lrs-350-36-assembly-bench.jpg\" width=\"1254\" height=\"1254\" alt=\"Adding an LC Output Filter to an SMPS: Check Ringing, Sensing and Load Steps  title=\" fetchpriority=\"high\" Adding an LC Output Filter to SMPS: Check Sensing and Load Steps title=\"\"><\/a><figcaption><a href=\"https:\/\/www.wehopower.com\/product\/lrs-series-350w-ac-to-dc-single-output-switching-power-supply\/\">WEHO LRS-350-36<\/a> shown on an equipment-assembly bench. Application illustration combining the product photograph with an AI-assisted environment; it does not depict an LC test. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/lrs-350-36-assembly-bench.jpg\">View full-size image<\/a>.<\/figcaption><\/figure>\n<p>This guide is for OEM engineers considering a filter on the DC output of a finished switching power supply. It provides a review and test method, rather than a universal set of component values. Board-level converter examples illustrate the principles; they do not establish compatibility with a particular WEHO model.<\/p>\n<nav class=\"toc\" aria-label=\"Table of contents\"><strong>In this guide<\/strong><\/p>\n<ol>\n<li><a href=\"#requirement\">Define the problem at the load<\/a><\/li>\n<li><a href=\"#sensing\">Check where the supply senses voltage<\/a><\/li>\n<li><a href=\"#network\">Review the complete output network<\/a><\/li>\n<li><a href=\"#example\">Calculate resonance and DC loss separately<\/a><\/li>\n<li><a href=\"#validation\">Use a before-and-after acceptance matrix<\/a><\/li>\n<li><a href=\"#decision\">Decide what can be released<\/a><\/li>\n<\/ol>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\u0130\u00e7indekiler Tablosunu A\u00e7\/Kapat\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/tr\/news\/smps-output-lc-filter-stability-load-step\/#1_Define_the_problem_at_the_load\" >1. Define the problem at the load<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/tr\/news\/smps-output-lc-filter-stability-load-step\/#2_Check_where_the_supply_senses_voltage\" >2. Check where the supply senses voltage<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/tr\/news\/smps-output-lc-filter-stability-load-step\/#3_Review_the_complete_output_network\" >3. Review the complete output network<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/tr\/news\/smps-output-lc-filter-stability-load-step\/#4_Calculate_resonance_and_DC_loss_separately\" >4. Calculate resonance and DC loss separately<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/tr\/news\/smps-output-lc-filter-stability-load-step\/#5_Use_a_before-and-after_acceptance_matrix\" >5. Use a before-and-after acceptance matrix<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/tr\/news\/smps-output-lc-filter-stability-load-step\/#6_Decide_what_can_be_released\" >6. Decide what can be released<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/tr\/news\/smps-output-lc-filter-stability-load-step\/#Discuss_an_output-filter_requirement_with_WEHO\" >Discuss an output-filter requirement with WEHO<\/a><\/li><\/ul><\/nav><\/div>\n<h2 id=\"requirement\"><span class=\"ez-toc-section\" id=\"1_Define_the_problem_at_the_load\"><\/span>1. Define the problem at the load<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Write the requirement before selecting an inductor: the load\u2019s allowed DC voltage range, ripple limit and measurement bandwidth, load-current range, and permitted excursions during startup and load changes. Record the cable length and the load\u2019s own input capacitance.<\/p>\n<p>These details determine what \u201cbetter\u201d means. A filter that lowers switching ripple but creates an unacceptable voltage dip when the load turns on has not solved the equipment requirement. If the existing measurement is uncertain, first establish a repeatable method using <a href=\"https:\/\/www.wehopower.com\/news\/power-supply-ripple-acceptance-test-matrix\/\">power-supply ripple acceptance criteria<\/a>.<\/p>\n<p>Keep the scope clear: this is an <strong>output<\/strong> network between the SMPS and its load. A DC-DC converter\u2019s input-filter interaction is a different problem, covered in <a href=\"https:\/\/www.wehopower.com\/news\/dc-dc-input-filter-resonance-source-impedance\/\">DC-DC input-filter resonance and source impedance<\/a>.<\/p>\n<h2 id=\"sensing\"><span class=\"ez-toc-section\" id=\"2_Check_where_the_supply_senses_voltage\"><\/span>2. Check where the supply senses voltage<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>In Figure 1, point A is at the supply terminals and point B is at the load. Record where the regulator\u2019s feedback actually measures voltage; do not assume it is at B simply because the load is connected there.<\/p>\n<figure id=\"figure-nodes\">\n  <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/output-filter-nodes.svg\" aria-label=\"Open the full-size output-filter measurement diagram\"><picture><source media=\"(max-width: 560px)\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/output-filter-nodes-mobile.svg\" width=\"700\" height=\"1050\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/output-filter-nodes.svg\" width=\"1400\" height=\"650\" alt=\"Adding an LC Output Filter to an SMPS: Check Ringing, Sensing and Load Steps  title=\" loading=\"lazy\" Adding an LC Output Filter to SMPS: Check Sensing and Load Steps title=\"\"><\/picture><\/a><figcaption>Figure 1. Measure at both ends of the added network. This functional illustration does not define terminals, polarity or installation wiring. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/output-filter-nodes.svg\">View full-size diagram<\/a>.<\/figcaption><\/figure>\n<p>If the supply regulates at A, the series path can introduce a voltage difference at B. <a href=\"https:\/\/www.emea.lambda.tdk.com\/fr-en\/faq\/question\/what-is-remote-sensing\" target=\"_blank\" rel=\"noopener\">Remote sensing<\/a> at B may compensate for some DC drop when the manufacturer permits that arrangement, but including the added filter in the sensed path also changes the control problem. Moving sense wires is not a general remedy for ringing.<\/p>\n<p>Analog Devices\u2019 <a href=\"https:\/\/www.analog.com\/en\/resources\/technical-articles\/designing-second-stage-output-filters-for-switching-power-supplies.html\" target=\"_blank\" rel=\"noopener\">second-stage output-filter design discussion<\/a> examines the effects of filtering and feedback placement. Its examples also show why a filter outside the feedback path should not automatically be treated as dynamically harmless.<\/p>\n<p>For a finished supply, obtain the model-specific limits for external capacitance, remote-sense compensation and any allowed post-filter arrangement. If the internal control-loop details are unavailable, retain the documented sense connection and ask the manufacturer to review the proposed network. Do not infer an approved configuration from a different converter\u2019s application circuit.<\/p>\n<figure id=\"figure-product-detail\" class=\"product-detail\">\n  <a class=\"detail-image-link\" href=\"https:\/\/www.wehopower.com\/product\/lrs-series-350w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"View WEHO LRS-350-36 product details\"><span class=\"product-detail-viewport\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/lrs-350-36-original.jpg\" width=\"1000\" height=\"1000\" loading=\"lazy\" alt=\"Adding an LC Output Filter to an SMPS: Check Ringing, Sensing and Load Steps  title=\" Adding an LC Output Filter to SMPS: Check Sensing and Load Steps title=\"\"><\/span><\/a><figcaption>Start with the exact model and its documentation. This detail view shows the <a href=\"https:\/\/www.wehopower.com\/product\/lrs-series-350w-ac-to-dc-single-output-switching-power-supply\/\">LRS-350-36<\/a> model label and terminal markings. Check the <a href=\"\/wp-content\/uploads\/weho-geo-2026-10-26\/documents\/LRS-350--a52f29f404f9.pdf\">LRS-350 model datasheet<\/a>, then request the output-network restrictions for your unit. This photo is not evidence of remote-sense or LC-filter compatibility. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/lrs-350-36-original.jpg\">View original product photo<\/a>.<\/figcaption><\/figure>\n<h2 id=\"network\"><span class=\"ez-toc-section\" id=\"3_Review_the_complete_output_network\"><\/span>3. Review the complete output network<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An LC label does not describe every relevant property. Review the parts as they will operate, including temperature, bias and the load already connected.<\/p>\n<p class=\"table-hint\">On small screens, scroll sideways to compare the network requirements.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Output-network review table\">\n<table>\n<thead>\n<tr>\n<th>Item<\/th>\n<th>What to establish<\/th>\n<th>Why it changes the decision<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Series inductor<\/td>\n<td>Inductance versus current, saturation rating, thermal current rating and DC resistance.<\/td>\n<td>Inductance and heating need separate checks at the relevant current.<\/td>\n<\/tr>\n<tr>\n<td>Added capacitor<\/td>\n<td>Effective capacitance, ESR, ripple-current capability, voltage and temperature limits.<\/td>\n<td>The operating values, rather than the label alone, define the network.<\/td>\n<\/tr>\n<tr>\n<td>Damping<\/td>\n<td>Documented damping method and its losses over the operating range.<\/td>\n<td>A low-loss LC network can have a pronounced resonance peak.<\/td>\n<\/tr>\n<tr>\n<td>Load and interconnect<\/td>\n<td>Load input capacitance, cable resistance\/inductance, startup sequence and current transitions.<\/td>\n<td>The installed system differs from an isolated filter calculation.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Coilcraft distinguishes <a href=\"https:\/\/www.coilcraft.com\/en-us\/resources\/application-notes\/current-and-temperature-ratings\/\" target=\"_blank\" rel=\"noopener\">saturation current and RMS current ratings<\/a>: they describe different constraints. Passing one rating does not establish the other.<\/p>\n<p>Texas Instruments\u2019 <a href=\"https:\/\/www.ti.com\/lit\/ta\/sszt824\/sszt824.pdf\" target=\"_blank\" rel=\"noopener\">second-stage filter design article<\/a> explains the importance of damping and the tradeoff with attenuation. Use that principle to request a justified design; its particular component ratios and damping values are not general rules for enclosed industrial supplies.<\/p>\n<p>If a ferrite bead is proposed instead of an inductor, review its impedance versus frequency and DC bias. Do not substitute a bead\u2019s single advertised impedance value into a constant-inductance LC calculation. Analog Devices discusses these effects in <a href=\"https:\/\/www.analog.com\/en\/resources\/analog-dialogue\/articles\/ferrite-beads-demystified.html\" target=\"_blank\" rel=\"noopener\">Ferrite Beads Demystified<\/a>.<\/p>\n<h2 id=\"example\"><span class=\"ez-toc-section\" id=\"4_Calculate_resonance_and_DC_loss_separately\"><\/span>4. Calculate resonance and DC loss separately<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The following numbers are an <strong>illustrative calculation, not a filter recommendation or a WEHO test result<\/strong>. Assume an ideal inductance of 10 \u00b5H, an effective capacitance of 47 \u00b5F, a 5 A steady load, and a series-inductor DC resistance of 40 m\u03a9 at the evaluated condition.<\/p>\n<div class=\"calculation\">\n<p><strong>Ideal LC natural frequency<\/strong><br \/><code>f\u2080 = 1 \/ (2\u03c0\u221aLC) \u2248 7.34 kHz<\/code><\/p>\n<p><strong>Inductor DC voltage drop<\/strong><br \/><code>\u0394V = I \u00d7 R = 5 A \u00d7 0.040 \u03a9 = 0.20 V<\/code><\/p>\n<p><strong>Inductor resistive dissipation<\/strong><br \/><code>P = I\u00b2R = (5 A)\u00b2 \u00d7 0.040 \u03a9 = 1.00 W<\/code><\/p>\n<\/div>\n<p>The natural frequency is not a measured oscillation frequency or a universal \u22123 dB cutoff. Damping changes the peak and shape of the response. The resistance calculation accounts only for the stated inductor resistance; connectors and cable add their own losses, and it does not predict temperature rise.<\/p>\n<figure id=\"figure-calculation\">\n  <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/lc-resonance-calculated.svg\" aria-label=\"Open the full-size calculated LC response\"><picture><source media=\"(max-width: 560px)\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/lc-resonance-mobile.svg\" width=\"700\" height=\"850\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/lc-resonance-calculated.svg\" width=\"1344\" height=\"768\" loading=\"lazy\" alt=\"Adding an LC Output Filter to an SMPS: Check Ringing, Sensing and Load Steps  title=\" Adding an LC Output Filter to SMPS: Check Sensing and Load Steps title=\"\"><\/picture><\/a><figcaption>Figure 2. Calculated ideal second-order LC response. The two damping ratios are chosen independently to illustrate response shape; they are not calculated from the 40 m\u03a9 resistance used in the DC-loss example. The converter, feedback loop and cable are omitted. This graph is not measured SMPS performance. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/10\/lc-resonance-calculated.svg\">View full-size calculation<\/a>.<\/figcaption><\/figure>\n<p>The plotted model is <code>H(j\u03c9) = 1 \/ [(1 \u2212 r\u00b2) + j2\u03b6r]<\/code>, where <code>r = f\/f\u2080<\/code>. The damping ratios \u03b6 = 0.2 and 0.7 are independently chosen examples; L and C alone do not determine them.<\/p>\n<p>The useful next question is whether the load still receives an acceptable voltage during its actual current transitions. Neither the nominal LC frequency nor a steady-load ripple reading answers that question.<\/p>\n<h2 id=\"validation\"><span class=\"ez-toc-section\" id=\"5_Use_a_before-and-after_acceptance_matrix\"><\/span>5. Use a before-and-after acceptance matrix<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>When load current rises abruptly, current through the series inductor cannot change instantaneously. The load-side capacitor supplies the initial current mismatch, while the voltage response depends on the supply, filter and load together. This is why the load\u2019s transition profile matters as much as its steady current.<\/p>\n<p>Keep the supply, input conditions, load program, wiring and measurement method consistent when comparing the original and filtered configurations. Capture A and B during the same event where practical, with probes and instruments appropriate to the circuit\u2019s isolation and voltage. Do not connect an earth-referenced instrument in a way that changes the intended reference.<\/p>\n<p>Fill in the project\u2019s numerical limits before testing. The table below is a proposed engineering record, not a claim that any model has passed these checks.<\/p>\n<p class=\"table-hint\">On small screens, scroll sideways to compare each check with its acceptance basis.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Before-and-after filter acceptance matrix\">\n<table class=\"matrix\">\n<thead>\n<tr>\n<th>Check<\/th>\n<th>Record before and after adding the filter<\/th>\n<th>Acceptance basis<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Steady load<\/td>\n<td>Voltage at A and B; ripple at the agreed bandwidth and load points.<\/td>\n<td>Supply-terminal limits at A; load DC and ripple limits at B, each with its agreed method.<\/td>\n<\/tr>\n<tr>\n<td>Startup and restart<\/td>\n<td>Rise, overshoot, startup time and any repeated restart or protection event.<\/td>\n<td>Load startup requirements and the supply\u2019s permitted output network.<\/td>\n<\/tr>\n<tr>\n<td>Load increase<\/td>\n<td>Current-step endpoints, edge rate, minimum voltage and recovery at B; compare A.<\/td>\n<td>Load undervoltage tolerance, recovery requirement and functional behavior.<\/td>\n<\/tr>\n<tr>\n<td>Load decrease<\/td>\n<td>Maximum voltage, ringing and recovery at B.<\/td>\n<td>Load overvoltage tolerance and recovery requirement.<\/td>\n<\/tr>\n<tr>\n<td>Light-load modes<\/td>\n<td>Behavior at the lowest intended load and relevant operating-mode transitions.<\/td>\n<td>Required voltage\/ripple range and absence of unacceptable functional disturbance.<\/td>\n<\/tr>\n<tr>\n<td>Operating corners<\/td>\n<td>Repeat critical events at specified input and temperature limits.<\/td>\n<td>The project envelope and component operating limits.<\/td>\n<\/tr>\n<tr>\n<td>Thermal and functional run<\/td>\n<td>Inductor temperature, voltage drop, component stress and actual equipment operation.<\/td>\n<td>Part ratings and equipment acceptance criteria.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Added capacitance must charge during startup. TI\u2019s <a href=\"https:\/\/www.ti.com\/lit\/an\/slyt669\/slyt669.pdf\" target=\"_blank\" rel=\"noopener\">discussion of startup into heavy capacitive loads<\/a> shows that current limit and soft-start behavior can affect successful startup. The relevant limit belongs to the actual supply and operating condition, not to a universal capacitance allowance.<\/p>\n<p>A successful set of load steps gives useful evidence within the tested envelope. It does not, by itself, establish control-loop margins across every condition. Where loop-interaction risk remains unresolved, request the manufacturer\u2019s analysis or an appropriately qualified stability assessment.<\/p>\n<h2 id=\"decision\"><span class=\"ez-toc-section\" id=\"6_Decide_what_can_be_released\"><\/span>6. Decide what can be released<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Record the result against the <strong>exact configuration<\/strong>: supply model and revision, filter parts, damping, sense connection, cable, load settings and test conditions. Keep both the ripple improvement and the worst observed startup or load-step behavior in the decision record.<\/p>\n<p>If ripple improves but load voltage exceeds its permitted range, revise the network or reconsider the power architecture. If the result depends on an undocumented sense connection or unknown component limits, resolve those gaps before treating the combination as qualified. When a configuration meets the agreed requirements, preserve its parts and conditions so later substitutions can be reviewed against the same evidence.<\/p>\n<aside class=\"article-cta\" aria-label=\"Contact WEHO about an output-filter requirement\">\n<h2><span class=\"ez-toc-section\" id=\"Discuss_an_output-filter_requirement_with_WEHO\"><\/span>Discuss an output-filter requirement with WEHO<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Send the exact supply model, required load voltage and ripple limit, current-step profile, proposed filter components, sense arrangement and cable length. Include the before-and-after measurements if available. Ask which model-specific output-network restrictions and validation information apply to your project.<\/p>\n<p><a class=\"button\" href=\"https:\/\/www.wehopower.com\/contact\/\">Send your project requirements<\/a><\/aside>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Review an SMPS output LC filter with a resonance calculation, sensing checks and a before-and-after test matrix for ripple, startup and load steps.<\/p>","protected":false},"author":2,"featured_media":20225,"parent":0,"menu_order":111,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-20230","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news\/20230","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/comments?post=20230"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news\/20230\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/media\/20225"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/media?parent=20230"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news_category?post=20230"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}