{"id":20997,"date":"2026-11-07T10:07:13","date_gmt":"2026-11-07T02:07:13","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/5v-terminal-contact-loss-localization\/"},"modified":"2026-11-07T10:07:13","modified_gmt":"2026-11-07T02:07:13","slug":"5v-terminal-contact-loss-localization","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/tr\/news\/5v-terminal-contact-loss-localization\/","title":{"rendered":"5 V Branch Troubleshooting: Separate Contact Loss from Cable Resistance"},"content":{"rendered":"<figure class=\"hero\"><a href=\"https:\/\/www.wehopower.com\/tr\/product\/mdr-series-ac-220v-to-dc-power-supply-10w-switching-power-supply\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/hero-25.webp\" alt=\"5 V Branch Troubleshooting: Separate Contact Loss from Cable Resistance  title=\" fetchpriority=\"high\" 5 branch troubleshooting: separate contact loss from cable resistance title=\"\"><\/a><figcaption>Conceptual 5 V contact-drop check, with probes on opposite sides of one positive-path connector. The meter shows a mode, not a measured result. AI-assisted illustration.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-18.jpg\">View original product image<\/a><\/figure>\n<p><strong>Measure a DC branch under a defined load before blaming the power supply or enlarging every cable.<\/strong> A poor connection can pass an unloaded voltage check yet create a localized drop and heating when current flows. Separate source behavior, conductor loss and individual contact loss.<\/p>\n<p>This method is intended for OEM maintenance and acceptance teams reviewing a small 5 V branch with an MDR-10-5 as the identified source. It does not authorize working on exposed mains or prescribe a torque value.<\/p>\n<nav class=\"toc\" aria-label=\"On this page\">\n<ol>\n<li><a href=\"#define-measurement-points\">Define the two measurements and the operating state<\/a><\/li>\n<li><a href=\"#estimate-path-loss\">Estimate the complete path loss before localizing it<\/a><\/li>\n<li><a href=\"#localize-loss\">Localize a loss without confusing it with the source<\/a><\/li>\n<li><a href=\"#convert-drop-to-local-heat\">Convert an observed local drop into a loss estimate<\/a><\/li>\n<li><a href=\"#close-the-record\">Close the record with a cause and a repeat measurement<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"define-measurement-points\">\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0130\u00e7indekiler<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\u0130\u00e7indekiler Tablosunu A\u00e7\/Kapat\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Ge\u00e7i\u015f yapmak<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/tr\/news\/5v-terminal-contact-loss-localization\/#Define_the_two_measurements_and_the_operating_state\" >Define the two measurements and the operating state<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/tr\/news\/5v-terminal-contact-loss-localization\/#Estimate_the_complete_path_loss_before_localizing_it\" >Estimate the complete path loss before localizing it<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/tr\/news\/5v-terminal-contact-loss-localization\/#Localize_a_loss_without_confusing_it_with_the_source\" >Localize a loss without confusing it with the source<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/tr\/news\/5v-terminal-contact-loss-localization\/#Convert_an_observed_local_drop_into_a_loss_estimate\" >Convert an observed local drop into a loss estimate<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/tr\/news\/5v-terminal-contact-loss-localization\/#Close_the_record_with_a_cause_and_a_repeat_measurement\" >Close the record with a cause and a repeat measurement<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/tr\/news\/5v-terminal-contact-loss-localization\/#Loaded_branch_loss_investigation\" >Loaded branch loss investigation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/tr\/news\/5v-terminal-contact-loss-localization\/#Sources_and_further_reading\" >Sources and further reading<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Define_the_two_measurements_and_the_operating_state\"><\/span>Define the two measurements and the operating state<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Record the source output voltage and receiver input voltage during the same stable state. Document meter accuracy, measurement locations, current and receiver behavior. An unloaded reading at the supply terminals does not describe the voltage at an operating receiver.<\/p>\n<p>The <a href=\"https:\/\/www.wehopower.com\/tr\/product\/mdr-series-ac-220v-to-dc-power-supply-10w-switching-power-supply\/\">MDR-10 product page<\/a> identifies the compact family. The original visible MDR-10-5 marking is retained as product identity. Use the exact supplied unit\u2019s limits when defining an approved load test; the small family name is not permission to apply an arbitrary diagnostic load.<\/p>\n<figure id=\"fig-original\" class=\"product-original\"><a href=\"https:\/\/www.wehopower.com\/tr\/product\/mdr-series-ac-220v-to-dc-power-supply-10w-switching-power-supply\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-18.jpg\" alt=\"5 V Branch Troubleshooting: Separate Contact Loss from Cable Resistance  title=\" loading=\"lazy\" 5 branch troubleshooting: separate contact loss from cable resistance title=\"\"><\/a><figcaption>Manufacturer image showing the WEHO MDR-10-5; the photograph identifies the pictured unit and does not establish equipment-level suitability.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-18.jpg\">View original image<\/a><\/figure>\n<\/section>\n<section id=\"estimate-path-loss\">\n<h2><span class=\"ez-toc-section\" id=\"Estimate_the_complete_path_loss_before_localizing_it\"><\/span>Estimate the complete path loss before localizing it<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Suppose an authorized test records 5.05 V across the source output terminals, 4.65 V across the receiver input terminals and 0.30 A through the branch. The hypothetical round-trip path loss is <strong>0.40 V<\/strong>, and its equivalent total loop resistance is <strong>R = \u0394V\/I = 1.33 \u03a9<\/strong>. This includes the positive conductor, return conductor and intervening contacts or series elements, not just one length of copper wire.<\/p>\n<p>Compare that result with the documented cable length, cross-section, temperature and connector arrangement. If the cable estimate accounts for only part of the drop, investigate the remaining contacts and paths. Meter uncertainty and non-simultaneous readings may matter when the drop is small or the load varies.<\/p>\n<figure id=\"fig-diagram\" class=\"diagram\"><img decoding=\"async\" class=\"technical-desktop\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-25.svg\" alt=\"5 V Branch Troubleshooting: Separate Contact Loss from Cable Resistance  title=\" loading=\"lazy\" 5 branch troubleshooting: separate contact loss from cable resistance title=\"\"><img decoding=\"async\" class=\"technical-mobile\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-mobile-25.svg\" alt=\"5 V Branch Troubleshooting: Separate Contact Loss from Cable Resistance  title=\" loading=\"lazy\" 5 branch troubleshooting: separate contact loss from cable resistance title=\"\"><figcaption>Hypothetical loaded measurements; no actual MDR-10 test or contact-temperature result.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-25.svg\">Open full-size technical illustration<\/a><\/figure>\n<\/section>\n<section id=\"localize-loss\">\n<h2><span class=\"ez-toc-section\" id=\"Localize_a_loss_without_confusing_it_with_the_source\"><\/span>Localize a loss without confusing it with the source<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Observation under the same state<\/th>\n<th scope=\"col\">Possible review direction<\/th>\n<th scope=\"col\">Evidence still required<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Source stable; receiver lower<\/td>\n<td>Distribution path<\/td>\n<td>Segment voltage drops and current<\/td>\n<\/tr>\n<tr>\n<td>Both source and receiver fall<\/td>\n<td>Source\/input\/load interaction<\/td>\n<td>Input condition and supply operating limits<\/td>\n<\/tr>\n<tr>\n<td>One connection has disproportionate drop<\/td>\n<td>Local contact or termination<\/td>\n<td>Approved inspection and connection instructions<\/td>\n<\/tr>\n<tr>\n<td>Result changes with motion or heat<\/td>\n<td>Intermittent interface<\/td>\n<td>Controlled, authorized repeatability test<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>These observations guide investigation; they do not diagnose a failed component by themselves. A localized drop can be caused by an incorrect crimp, damaged contact, contamination or an unsuitable mating combination. Document what is actually found.<\/p>\n<\/section>\n<section id=\"convert-drop-to-local-heat\">\n<h2><span class=\"ez-toc-section\" id=\"Convert_an_observed_local_drop_into_a_loss_estimate\"><\/span>Convert an observed local drop into a loss estimate<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>If 0.25 V of the example drop occurs across one connection at 0.30 A, its electrical loss is <strong>P = I\u0394V = 0.075 W<\/strong>. This is a local heat input. It is not a predicted contact temperature, and there is no universal acceptable temperature rise derived from this number alone.<\/p>\n<p>Phoenix Contact\u2019s <a href=\"https:\/\/www.phoenixcontact.com\/en-us\/products\/pcb-connector-dd31pc-22-4-381-y-1341274?type=pdf\" target=\"_blank\" rel=\"noopener\">connector data<\/a> illustrates that allowed current depends on the specified contact and conductor conditions. It does not supply ratings for the unidentified connection in this example. Use the actual terminal or connector instructions for inspection and rework.<\/p>\n<p>Do not tighten a powered connection as an exploratory test. Perform any physical intervention under the approved isolation and verification procedure, then repeat the same loaded measurement after documented rework.<\/p>\n<\/section>\n<section id=\"close-the-record\">\n<h2><span class=\"ez-toc-section\" id=\"Close_the_record_with_a_cause_and_a_repeat_measurement\"><\/span>Close the record with a cause and a repeat measurement<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Retain before-and-after values, the actual defect, repair method and current hardware revision. Confirm that the receiver voltage meets its stated limit across the intended states. A reduced drop at one state is not proof that every intermittent or thermal condition has disappeared.<\/p>\n<p>If the connection is sound and the cable accounts for the loss, revise the branch design using a voltage budget. If the source itself leaves its permitted range, investigate its operating point separately. Keeping those decisions distinct prevents a good supply being replaced while a bad termination remains in service.<\/p>\n<\/section>\n<section class=\"cta\">\n<p>Share the <a href=\"https:\/\/www.wehopower.com\/tr\/product\/mdr-series-ac-220v-to-dc-power-supply-10w-switching-power-supply\/\">MDR-10-5 branch record<\/a> with source and receiver voltages from the same loaded state, current, segment drops, connection identities and before-and-after findings. Request the supplied revision\u2019s limits if the source itself is suspect; use the documented contact or cable evidence to resolve the distribution fault.<\/p>\n<\/section>\n<section id=\"worksheet\" class=\"sheet\">\n<h2><span class=\"ez-toc-section\" id=\"Loaded_branch_loss_investigation\"><\/span>Loaded branch loss investigation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"sheet-row\"><label>Source and receiver revisions<input aria-label=\"Source and receiver revisions\"><\/label><label>Authorized test state<input aria-label=\"Authorized test state\"><\/label><label>Instruments and uncertainty<input aria-label=\"Instruments and uncertainty\"><\/label><label>Inspection procedure<input aria-label=\"Inspection procedure\"><\/label><\/div>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">State\/current<\/th>\n<th scope=\"col\">Source voltage<\/th>\n<th scope=\"col\">Receiver voltage<\/th>\n<th scope=\"col\">Segment\/contact loss<\/th>\n<th scope=\"col\">Finding and action<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Blank project worksheet. Enter verified project data; example calculations above are not measurements.<\/p>\n<\/section>\n<section class=\"source-list\">\n<h2><span class=\"ez-toc-section\" id=\"Sources_and_further_reading\"><\/span>Sources and further reading<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><a href=\"https:\/\/www.wehopower.com\/tr\/product\/mdr-series-ac-220v-to-dc-power-supply-10w-switching-power-supply\/\">WEHO MDR-10 product information<\/a><\/li>\n<li><a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/MDR-10.pdf\">WEHO MDR-10 specification<\/a><\/li>\n<li><a href=\"https:\/\/www.phoenixcontact.com\/en-us\/products\/pcb-connector-dd31pc-22-4-381-y-1341274?type=pdf\" target=\"_blank\" rel=\"noopener\">Phoenix Contact connector data and operating notes<\/a><\/li>\n<\/ol>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Use paired loaded voltage measurements and a local loss estimate to find a poor branch connection without treating an unloaded 5 V reading as acceptance.<\/p>","protected":false},"author":2,"featured_media":20965,"parent":0,"menu_order":84,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-20997","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news\/20997","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/comments?post=20997"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news\/20997\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/media\/20965"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/media?parent=20997"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news_category?post=20997"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}