{"id":23596,"date":"2026-11-23T10:19:07","date_gmt":"2026-11-23T02:19:07","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/cable-shield-high-frequency-bond\/"},"modified":"2026-11-23T10:19:07","modified_gmt":"2026-11-23T02:19:07","slug":"cable-shield-high-frequency-bond","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/","title":{"rendered":"Cable Shield Termination: Compare the High-Frequency Bond Path"},"content":{"rendered":"<div class=\"weho-blog\">\n<p>A cable shield connection needs suitable impedance at the interference frequency, not only a low resistance on a continuity meter. Compare the complete shield-to-enclosure path before accepting a pigtail, clamp or connector change in an OEM cabinet.<\/p>\n<div class=\"key-takeaways\"><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Follow the interference current&#39;s complete return path.<\/li>\n<li>Keep DC resistance and high-frequency impedance separate.<\/li>\n<li>Assess circumferential contact with the cable and enclosure together.<\/li>\n<li>Preserve protective-earth and signal-reference requirements during an EMC change.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"K04-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/tr\/product\/ndr-dinrail-240w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"NDR-240-24 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/dfde7b4c2a46e5ee-ndr-240-24-application.webp\" alt=\"NDR-240-24 product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" title=\"\"><\/a><figcaption>Application illustration of NDR-240-24 in an equipment setting; not a customer installation photo. Scene created with AI assistance. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/5d20177cce824342-application-master.png\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#1-define-the-connection-being-purchased\">1. Define the connection being purchased<\/a><\/li>\n<li><a href=\"#2-follow-the-path-beyond-the-first-metal-contact\">2. Follow the path beyond the first metal contact<\/a><\/li>\n<li><a href=\"#3-recalculate-two-assumed-connection-impedances\">3. Recalculate two assumed connection impedances<\/a><\/li>\n<li><a href=\"#4-keep-shielding-reference-and-protection-distinct\">4. Keep shielding, reference and protection distinct<\/a><\/li>\n<li><a href=\"#5-release-the-connection-system-with-a-verification-record\">5. Release the connection system with a verification record<\/a><\/li>\n<li><a href=\"#6-send-a-cabinet-interface-question-to-weho\">6. Send a cabinet-interface question to WEHO<\/a><\/li>\n<li><a href=\"#7-engineering-faq\">7. Engineering FAQ<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0130\u00e7indekiler<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\u0130\u00e7indekiler Tablosunu A\u00e7\/Kapat\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Ge\u00e7i\u015f yapmak<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#1_Define_the_connection_being_purchased\" >1. Define the connection being purchased<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#2_Follow_the_path_beyond_the_first_metal_contact\" >2. Follow the path beyond the first metal contact<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#3_Recalculate_two_assumed_connection_impedances\" >3. Recalculate two assumed connection impedances<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#4_Keep_shielding_reference_and_protection_distinct\" >4. Keep shielding, reference and protection distinct<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#5_Release_the_connection_system_with_a_verification_record\" >5. Release the connection system with a verification record<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#6_Send_a_cabinet-interface_question_to_WEHO\" >6. Send a cabinet-interface question to WEHO<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#7_Engineering_FAQ\" >7. Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#Does_a_low_continuity_resistance_prove_a_good_high-frequency_shield_bond\" >Does a low continuity resistance prove a good high-frequency shield bond?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#Is_a_circumferential_shield_connection_a_substitute_for_protective_earth\" >Is a circumferential shield connection a substitute for protective earth?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#Are_100_nH_and_10_nH_typical_values_for_the_photographed_cabinet\" >Are 100 nH and 10 nH typical values for the photographed cabinet?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/tr\/news\/cable-shield-high-frequency-bond\/#Should_every_cable_shield_be_connected_at_both_ends\" >Should every cable shield be connected at both ends?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"1-define-the-connection-being-purchased\"><span class=\"ez-toc-section\" id=\"1_Define_the_connection_being_purchased\"><\/span>1. Define the connection being purchased<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A shielded cable can enter a cabinet through a gland, connector or clamp arrangement. The presence of braid does not describe how that braid contacts the enclosure or reaches the intended reference. The useful purchasing output is a defined connection system, including its geometry, materials, installation instructions and applicable frequency-dependent evidence.<\/p>\n<p>The <a href=\"https:\/\/www.wehopower.com\/tr\/product\/ndr-dinrail-240w-ac-to-dc-single-output-switching-power-supply\/\">WEHO NDR-240-24 product reference<\/a> identifies a supply within the cabinet context. The shield connection belongs to the external equipment design; no shield-clamp rating or EMC improvement is assigned to the supply. Review that connection separately from the supply&#39;s input, output and protective-earth terminals.<\/p>\n<p><a href=\"https:\/\/www.analog.com\/media\/en\/training-seminars\/design-handbooks\/power-thermal-mgmt-sect8.pdf\" target=\"_blank\" rel=\"noopener\">Analog Devices&#39; hardware-design guidance<\/a> explains how pigtails and gaps can compromise high-frequency shielding. It discusses circumferential contact at the cable-to-enclosure transition. Treat those principles as a reason to examine the actual path, rather than as a universal installation drawing for every interface.<\/p>\n<h2 id=\"2-follow-the-path-beyond-the-first-metal-contact\"><span class=\"ez-toc-section\" id=\"2_Follow_the_path_beyond_the_first_metal_contact\"><\/span>2. Follow the path beyond the first metal contact<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A clamp can contact the braid effectively while its mounting structure leaves a long route to the enclosure reference. A connector shell can have good cable contact but a poorly controlled panel interface. Record every relevant joint instead of judging the assembly from the first visible connection.<\/p>\n<p><a href=\"https:\/\/www.phoenixcontact.com\/en-ca\/technologies\/shielding\/shield-connection-in-control-cabinets\" target=\"_blank\" rel=\"noopener\">Phoenix Contact&#39;s cabinet-shielding guidance<\/a> distinguishes contact resistance from frequency-dependent inductive effects. The complete path includes the clamp, support and reference connection. Its description supports requesting a frequency-dependent connection characteristic rather than assuming a continuity result fully describes shielding performance.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Path element<\/th>\n<th scope=\"col\">Record<\/th>\n<th scope=\"col\">Question before release<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cable shield<\/td>\n<td>Construction, diameter and permitted preparation<\/td>\n<td>Does the chosen contact system match this cable?<\/td>\n<\/tr>\n<tr>\n<td>Shield termination<\/td>\n<td>Clamp or connector, contact geometry and instructions<\/td>\n<td>How is the braid connected without an unintended long path?<\/td>\n<\/tr>\n<tr>\n<td>Mounting interface<\/td>\n<td>Support, shell, panel surface and joining method<\/td>\n<td>Is the intended conductive path actually maintained?<\/td>\n<\/tr>\n<tr>\n<td>Reference structure<\/td>\n<td>Enclosure, shield bar and approved reference arrangement<\/td>\n<td>Where does the interference current return?<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>A shield termination and a strain-relief device also have different jobs. The existing <a href=\"https:\/\/www.wehopower.com\/tr\/news\/power-supply-cable-glands-strain-relief\/\">cable-gland and strain-relief guide<\/a> addresses mechanical loads reaching terminals. Neither good mechanical retention nor an attractive gland proves the required high-frequency connection.<\/p>\n<p>Record the intended service condition as well as initial assembly. Corrosion, loosening or an unapproved replacement cable can change the path. Use the selected manufacturer&#39;s maintenance and installation requirements; do not invent a common retightening interval or contact-pressure value for unrelated hardware.<\/p>\n<h2 id=\"3-recalculate-two-assumed-connection-impedances\"><span class=\"ez-toc-section\" id=\"3_Recalculate_two_assumed_connection_impedances\"><\/span>3. Recalculate two assumed connection impedances<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Consider a deliberately simplified series resistance-inductance model. Assume connection A has 0.010 \u03a9 resistance and 100 nH inductance, while connection B has the same resistance and 10 nH inductance. These values are hypothetical; they are not measured pigtail, shield-clamp or NDR-240-24 properties.<\/p>\n<p>For the assumed model, inductive reactance is X_L = 2\u03c0fL, and impedance magnitude is |Z| = \u221a(R\u00b2 + X_L\u00b2). At 1 MHz, connection A has approximately 0.628 \u03a9 reactance and 0.628 \u03a9 impedance magnitude. Connection B has approximately 0.0628 \u03a9 reactance and 0.0636 \u03a9 impedance magnitude.<\/p>\n<p>At 10 MHz, the calculated magnitudes become approximately 6.283 \u03a9 for A and 0.628 \u03a9 for B. Both connections still have the same assumed 0.010 \u03a9 DC resistance. A DC resistance comparison would therefore miss the difference created by their assumed inductance.<\/p>\n<figure class=\"article-figure technical\" data-asset=\"K04-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/b6f2ac89c4109014-technical.svg\" alt=\"Assumed connection impedance curves diverge with frequency despite matching direct-current resistance values.\" width=\"1200\" height=\"675\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Assumed 0.010 \u03a9 series resistance with 100 nH or 10 nH inductance illustrates frequency dependence; no actual shield hardware or NDR test is characterized. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/b6f2ac89c4109014-technical.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>If an assumed 0.10 A RMS single-frequency current passed through those 10 MHz impedances, the corresponding voltage magnitudes would be approximately 0.628 V and 0.0628 V. This arithmetic explains a possible voltage developed across a path. It does not calculate shielding effectiveness, equipment emission or immunity improvement.<\/p>\n<p>The model omits distributed cable behavior, contact capacitance, coupling and the rest of the enclosure. At sufficiently high frequency, those omissions can invalidate a simple lumped representation. Use the model as a screening explanation and obtain relevant system measurements or characterized connection data for the actual decision.<\/p>\n<h2 id=\"4-keep-shielding-reference-and-protection-distinct\"><span class=\"ez-toc-section\" id=\"4_Keep_shielding_reference_and_protection_distinct\"><\/span>4. Keep shielding, reference and protection distinct<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Protective-earth bonding, a functional interference return and a common signal reference can serve different purposes. <a href=\"https:\/\/infosys.beckhoff.com\/content\/1033\/ioanalogmanual\/2346576779.html\" target=\"_blank\" rel=\"noopener\">Beckhoff&#39;s analog-equipment guidance<\/a> explicitly distinguishes those aims and requires application-specific assessment. A shielding proposal cannot silently replace a required protective conductor or change the receiving interface&#39;s permitted reference conditions.<\/p>\n<p>The existing <a href=\"https:\/\/www.wehopower.com\/tr\/news\/protective-earth-continuity-specify-the-endpoints-and-record-the-result\/\">protective-earth continuity article<\/a> remains the appropriate companion when verifying the specified protective path. This article&#39;s impedance example does not set an earth-bond acceptance limit. Keep the relevant electrical-safety and EMC records separate even when parts of their physical paths are shared.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Assumed model<\/th>\n<th scope=\"col\">DC resistance<\/th>\n<th scope=\"col\">|Z| at 1 MHz<\/th>\n<th scope=\"col\">|Z| at 10 MHz<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A: 100 nH series inductance<\/td>\n<td>0.010 \u03a9<\/td>\n<td>0.628 \u03a9<\/td>\n<td>6.283 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>B: 10 nH series inductance<\/td>\n<td>0.010 \u03a9<\/td>\n<td>0.0636 \u03a9<\/td>\n<td>0.628 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Interpretation<\/td>\n<td>Identical by assumption<\/td>\n<td>Frequency-dependent paths differ<\/td>\n<td>No measured product attenuation inferred<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Do not reduce every shielding problem to a rule that both cable ends must always be bonded identically. Interference mechanism, cable electrical length, reference-potential differences and device instructions matter. The responsible equipment designer must reconcile them rather than apply a general illustration as a field modification.<\/p>\n<p>Check the boundary of any published impedance curve before comparing suppliers. A curve for a clamp on a particular support does not automatically include your painted panel joint, connector shell or longer reference route. Request the fixture definition, calibration treatment and mounting configuration with the curve.<\/p>\n<p>Also separate a component-level comparison from the installed equipment result. A lower characterized connection impedance may be useful evidence, but the actual interference current and coupling mechanism can change after installation. Verify the affected function or emission under the released configuration rather than converting an impedance ratio directly into a promised decibel improvement.<\/p>\n<p>A proposed capacitive or isolated shield termination introduces its own component and safety requirements. It is not a casual workaround for an unexplained ground-loop symptom. Document the intended function, permitted potentials and applicable equipment instructions before considering such a design change.<\/p>\n<figure class=\"article-figure product\" data-asset=\"K04-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/tr\/product\/ndr-dinrail-240w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"NDR-240-24 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/2e3b109c73664e7b-ndr-240-24-product-reference.webp\" alt=\"NDR-240-24 product reference preserving the original housing, visible label and connection features.\" width=\"800\" height=\"800\" decoding=\"async\" title=\"\"><\/a><figcaption>Product appearance reference for NDR-240-24, preserving the source housing, visible label and connections. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/1b88961a2a1ee7e5-product-original.jpg\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"5-release-the-connection-system-with-a-verification-record\"><span class=\"ez-toc-section\" id=\"5_Release_the_connection_system_with_a_verification_record\"><\/span>5. Release the connection system with a verification record<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Identify the interference path.<\/strong> Record the affected interface, frequency region, operating state and observed symptom. Verify that the investigation distinguishes a source, coupling path and affected function.<\/li>\n<li><strong>Document every connection.<\/strong> Record the cable, termination hardware, shell or support, panel interface and reference path. Verify each item against the selected manufacturer&#39;s assembly instructions.<\/li>\n<li><strong>Request suitable evidence.<\/strong> Record contact and frequency-dependent data, its test arrangement and the relevant mechanical conditions. Verify that a supplied curve concerns the proposed connection system rather than a different fixture.<\/li>\n<li><strong>Compare controlled configurations.<\/strong> Record the original and proposed arrangements with unchanged operating conditions. Verify the affected EMC and functional behavior using the agreed test method and acceptance basis.<\/li>\n<li><strong>Control production and service.<\/strong> Record approved parts, preparation, inspection and change triggers. Verify that replacement cables and repaired enclosure interfaces preserve the released configuration.<\/li>\n<\/ol>\n<p>Change one relevant feature at a time when investigating a suspected transfer path. Preserve repeatable baseline data and the actual assembly record. A favorable observation after several simultaneous changes cannot identify which change was responsible or establish a general product claim.<\/p>\n<h2 id=\"6-send-a-cabinet-interface-question-to-weho\"><span class=\"ez-toc-section\" id=\"6_Send_a_cabinet-interface_question_to_WEHO\"><\/span>6. Send a cabinet-interface question to WEHO<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For an <a href=\"https:\/\/www.wehopower.com\/tr\/product\/ndr-dinrail-240w-ac-to-dc-single-output-switching-power-supply\/\">NDR-240-24 cabinet integration review<\/a>, send the exact supply identity, external interface drawing, cable construction, intended reference scheme and the relevant EMC finding. Identify which part of the shield path is changing and which equipment functions must remain correct. Request matching supply documentation while the responsible designer qualifies the external connection system.<\/p>\n<h2 id=\"7-engineering-faq\"><span class=\"ez-toc-section\" id=\"7_Engineering_FAQ\"><\/span>7. Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"does-a-low-continuity-resistance-prove-a-good-high-frequency-shield-bond\"><span class=\"ez-toc-section\" id=\"Does_a_low_continuity_resistance_prove_a_good_high-frequency_shield_bond\"><\/span>Does a low continuity resistance prove a good high-frequency shield bond?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Inductance and the complete frequency-dependent return path can dominate the connection at the interference frequency. Retain the appropriate connection data and system evidence.<\/p>\n<h3 id=\"is-a-circumferential-shield-connection-a-substitute-for-protective-earth\"><span class=\"ez-toc-section\" id=\"Is_a_circumferential_shield_connection_a_substitute_for_protective_earth\"><\/span>Is a circumferential shield connection a substitute for protective earth?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. Protective bonding has its own required path and acceptance basis. Assess shielding and signal references alongside those requirements without silently replacing them.<\/p>\n<h3 id=\"are-100-nh-and-10-nh-typical-values-for-the-photographed-cabinet\"><span class=\"ez-toc-section\" id=\"Are_100_nH_and_10_nH_typical_values_for_the_photographed_cabinet\"><\/span>Are 100 nH and 10 nH typical values for the photographed cabinet?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. They are explicit assumptions for a simplified calculation. No inductance, attenuation or EMC result is measured or assigned to the pictured equipment.<\/p>\n<h3 id=\"should-every-cable-shield-be-connected-at-both-ends\"><span class=\"ez-toc-section\" id=\"Should_every_cable_shield_be_connected_at_both_ends\"><\/span>Should every cable shield be connected at both ends?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Not as a universal rule. Use the interface instructions and the equipment&#39;s grounding, potential and interference assessment to define the actual termination scheme.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Assess shield termination impedance, enclosure contact and reference paths. Send WEHO your NDR-240-24 cabinet-interface record and EMC requirements.<\/p>","protected":false},"author":2,"featured_media":22238,"parent":0,"menu_order":20,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-23596","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news\/23596","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/comments?post=23596"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news\/23596\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/media\/22238"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/media?parent=23596"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/tr\/wp-json\/wp\/v2\/news_category?post=23596"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}