{"id":16245,"date":"2026-08-15T10:59:50","date_gmt":"2026-08-15T02:59:50","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=news&#038;p=16245"},"modified":"2026-11-17T15:39:53","modified_gmt":"2026-11-17T07:39:53","slug":"security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/","title":{"rendered":"CCTV Power Supply Sizing: 12V Camera Load, Voltage Drop and Cable Distance"},"content":{"rendered":"<p class=\"byline\">By WEHO Electronics \u00b7 Published August 15, 2026 \u00b7 Updated November 17, 2026<\/p>\n<figure class=\"hero\">\n<div class=\"tech-scroll\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/cctv-12v-voltage-drop-loop-diagram-hero.webp\" alt=\"Conceptual 12 V CCTV loop-drop diagram showing camera voltage in a 12 AWG PTZ example\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" data-image-role=\"hero\" title=\"\"><\/div><figcaption>Conceptual diagram and worked example: both conductors carry the branch current, so the drop uses the loop length 2L. Values shown are the 2.0 A PTZ branch on 60 m of 12 AWG in Step 2. Not a photograph or a measured result.<\/figcaption><\/figure>\n<div class=\"takeaways\">\n<p><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>Size the 12 V supply from the <strong>worst-case current<\/strong> of every camera (IR, heater and PTZ motion on), not from daytime current.<\/li>\n<li>Check each branch: <strong>V<sub>drop<\/sub> = I \u00d7 2L \u00d7 R<\/strong>, using the outbound and return conductor.<\/li>\n<li>At 1.0 A and a 1.2 V drop budget, 18 AWG copper reaches only about 29 m one way.<\/li>\n<li>Read the model&#8217;s derating curve at the real enclosure temperature before accepting the rating.<\/li>\n<\/ul>\n<\/div>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0645\u0646\u062f\u0631\u062c\u0627\u062a \u06a9\u0627 \u062c\u062f\u0648\u0644<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u0679\u0648\u06af\u0644 \u06a9\u0631\u06cc\u06ba\u06d4<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#Why_12V_CCTV_Runs_Fail_When_the_Supply_Looks_Big_Enough\" >Why 12V CCTV Runs Fail When the Supply Looks Big Enough<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#Step_1_Size_the_Supply_From_Worst-Case_Camera_Current\" >Step 1: Size the Supply From Worst-Case Camera Current<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#Step_2_Check_Voltage_Drop_on_Every_Camera_Branch\" >Step 2: Check Voltage Drop on Every Camera Branch<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#Maximum_12V_Cable_Distance_by_Wire_Gauge\" >Maximum 12V Cable Distance by Wire Gauge<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#Central_or_Local_Supply_Choosing_an_LRS_Model\" >Central or Local Supply: Choosing an LRS Model<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#Commissioning_Checks_Before_Handover\" >Commissioning Checks Before Handover<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#Send_Your_Camera_Schedule_for_a_Model_Check\" >Send Your Camera Schedule for a Model Check<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#FAQ\" >\u0627\u06a9\u062b\u0631 \u067e\u0648\u0686\u06be\u06d2 \u06af\u0626\u06d2 \u0633\u0648\u0627\u0644\u0627\u062a<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#How_do_I_calculate_voltage_drop_on_a_12V_CCTV_cable\" >How do I calculate voltage drop on a 12V CCTV cable?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#What_is_the_maximum_cable_distance_for_a_12V_camera\" >What is the maximum cable distance for a 12V camera?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#Can_I_raise_the_supply_voltage_to_make_up_for_voltage_drop\" >Can I raise the supply voltage to make up for voltage drop?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/#Should_I_use_one_central_supply_or_several_local_supplies\" >Should I use one central supply or several local supplies?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"why-12v-cctv-runs-fail\"><span class=\"ez-toc-section\" id=\"Why_12V_CCTV_Runs_Fail_When_the_Supply_Looks_Big_Enough\"><\/span>Why 12V CCTV Runs Fail When the Supply Looks Big Enough<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A central 12 V supply can have ample wattage and still leave the farthest camera under-voltage. At night, IR illuminators, heaters and PTZ motors raise current, and the cable converts that current into lost volts. The result is a camera that works during the day and reboots after dark.<\/p>\n<p>The fix is two separate checks: a load check at the supply terminals and a voltage check at each camera. The sections below work through both with numbers you can recalculate.<\/p>\n<p>This article sizes a regulated 12.0 V LRS system and calculates cable distance from published copper resistance. For a multi-camera design that starts from a 13.8 V main output, a separate charging branch, backup runtime and the split between direct low-voltage and PoE, see <a href=\"https:\/\/www.wehopower.com\/ur\/news\/the-importance-of-choosing-the-right-power-supply-for-your-cctv-cameras\/\">CCTV supply selection for multi-camera systems<\/a>.<\/p>\n<h2 id=\"size-the-supply\"><span class=\"ez-toc-section\" id=\"Step_1_Size_the_Supply_From_Worst-Case_Camera_Current\"><\/span>Step 1: Size the Supply From Worst-Case Camera Current<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use the maximum current from each camera datasheet, with every load that can be on at the same time. The numbers below are a <strong>worked example<\/strong>: camera currents are assumed values, not measurements of a specific camera.<\/p>\n<ul>\n<li>8 fixed IR bullets \u00d7 0.5 A = 4.0 A<\/li>\n<li>2 IR domes \u00d7 0.6 A = 1.2 A<\/li>\n<li>2 PTZ cameras with heater \u00d7 2.0 A = 4.0 A<\/li>\n<li>Total continuous current = 9.2 A, or 9.2 A \u00d7 12 V = 110.4 W<\/li>\n<\/ul>\n<p>This example chooses an <strong>80% design load ratio<\/strong>, so the rated current must be at least 9.2 A \u00f7 0.8 = 11.5 A. The 80% figure is a design choice for this example, not a general WEHO rule. The <a href=\"https:\/\/www.wehopower.com\/ur\/product\/lrs-series-200w-ac-to-dc-single-output-switching-power-supply\/\">LRS-200-12 12 V 17 A enclosed supply<\/a> is rated 0\u201317 A, so the calculated load is 9.2 \u00f7 17 = 54% of rating.<\/p>\n<p>Next, check temperature. The LRS-200 derating curve for 12\u201348 V outputs (horizontal mounting) shows 100% load up to 50 \u00b0C and 50% at 70 \u00b0C. At 70 \u00b0C the LRS-200-12 therefore allows 8.5 A, which is below the 9.2 A load. Between 50 \u00b0C and 70 \u00b0C, read the published curve rather than estimating.<\/p>\n<p>Finally, check start-up. If both PTZ cameras could draw an assumed 3.0 A peak at the same moment, the total becomes 4.0 + 1.2 + 6.0 = 11.2 A. That is within the 17 A rating up to 50 \u00b0C, but above the 8.5 A allowed at 70 \u00b0C, so confirm the camera&#8217;s real start-up current and duration. The LRS-200 datasheet describes its overload protection as \u201c110%\uff5e150% cut off the output, automatic recovery\u201d.<\/p>\n<h2 id=\"check-voltage-drop\"><span class=\"ez-toc-section\" id=\"Step_2_Check_Voltage_Drop_on_Every_Camera_Branch\"><\/span>Step 2: Check Voltage Drop on Every Camera Branch<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Low-voltage DC current flows out on the positive conductor and back on the negative conductor, so the loop length is twice the one-way distance.<\/p>\n<p class=\"formula\">V<sub>drop<\/sub> = I \u00d7 2 \u00d7 L \u00d7 R<br \/>V<sub>camera<\/sub> = V<sub>supply<\/sub> \u2212 V<sub>drop<\/sub><\/p>\n<p>Here I is the branch current in amperes, L is the one-way length in meters and R is conductor resistance in ohms per meter. The resistance values are the published 20 \u00b0C values in NIST Handbook 100, Table 11 (standard annealed copper, solid wire). Stranded and copper-clad aluminum (CCA) cable will differ, so use the cable maker&#8217;s datasheet when it is available.<\/p>\n<p>Using the same example, with the supply set to 12.0 V and an assumed camera minimum of 10.8 V:<\/p>\n<ol>\n<li>Bullet, 0.5 A, 40 m of 18 AWG: 0.5 \u00d7 80 \u00d7 0.0210 = 0.84 V drop, 11.16 V at the camera. Pass.<\/li>\n<li>Dome, 0.6 A, 55 m of 18 AWG: 1.39 V drop, 10.61 V. Fail. With 16 AWG: 0.87 V drop, 11.13 V. Pass.<\/li>\n<li>PTZ, 2.0 A, 60 m of 16 AWG: 3.17 V drop, 8.83 V. Fail. With 12 AWG: 1.25 V drop, 10.75 V. Fail, just below the assumed 10.8 V minimum.<\/li>\n<li>PTZ fed by a local LRS-50-12 with 5 m of 18 AWG: 0.42 V drop, 11.58 V. Pass.<\/li>\n<\/ol>\n<p>Conductor resistance also rises with temperature. In the NIST table, 18 AWG rises from 21.0 \u03a9\/km at 20 \u00b0C to 23.4 \u03a9\/km at 50 \u00b0C, about 11% more drop on hot outdoor runs.<\/p>\n<h2 id=\"cable-distance-by-awg\"><span class=\"ez-toc-section\" id=\"Maximum_12V_Cable_Distance_by_Wire_Gauge\"><\/span>Maximum 12V Cable Distance by Wire Gauge<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The table gives the longest one-way run that keeps the calculated loop drop at 1.2 V, which is 10% of 12 V. It assumes solid copper at 20 \u00b0C and ignores connector resistance, so treat it as an upper bound. If your camera accepts a lower minimum voltage, recalculate with that budget.<\/p>\n<div class=\"table-wrap\">\n<table>\n<caption>Maximum one-way distance for a 1.2 V drop at 12 V DC (calculation example, solid copper, 20 \u00b0C)<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Copper size<\/th>\n<th scope=\"col\">Resistance (\u03a9\/km)<\/th>\n<th scope=\"col\">0.5 A load<\/th>\n<th scope=\"col\">1.0 A load<\/th>\n<th scope=\"col\">2.0 A load<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>22 AWG<\/td>\n<td>53.2<\/td>\n<td>22.6 m<\/td>\n<td>11.3 m<\/td>\n<td>5.6 m<\/td>\n<\/tr>\n<tr>\n<td>20 AWG<\/td>\n<td>33.2<\/td>\n<td>36.1 m<\/td>\n<td>18.1 m<\/td>\n<td>9.0 m<\/td>\n<\/tr>\n<tr>\n<td>18 AWG<\/td>\n<td>21.0<\/td>\n<td>57.1 m<\/td>\n<td>28.6 m<\/td>\n<td>14.3 m<\/td>\n<\/tr>\n<tr>\n<td>16 AWG<\/td>\n<td>13.2<\/td>\n<td>90.9 m<\/td>\n<td>45.5 m<\/td>\n<td>22.7 m<\/td>\n<\/tr>\n<tr>\n<td>14 AWG<\/td>\n<td>8.28<\/td>\n<td>144.9 m<\/td>\n<td>72.5 m<\/td>\n<td>36.2 m<\/td>\n<\/tr>\n<tr>\n<td>12 AWG<\/td>\n<td>5.21<\/td>\n<td>230.3 m<\/td>\n<td>115.2 m<\/td>\n<td>57.6 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure class=\"tech\">\n<div class=\"tech-scroll\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/cctv-12v-cable-distance-by-awg-chart.svg\" alt=\"Maximum one-way 12 V CCTV cable distance versus current for 22\u201312 AWG solid copper\" width=\"1200\" height=\"675\" decoding=\"async\" data-image-role=\"technical\" title=\"\"><\/div><figcaption>Calculation example: L<sub>max<\/sub> = 1.2 V \u00f7 (2 \u00d7 I \u00d7 R), NIST Handbook 100 resistance at 20 \u00b0C. Not a measured result.<\/figcaption><\/figure>\n<p>Maximum distance is inversely proportional to current: a 2 A PTZ draws four times the current of a 0.5 A bullet, so it needs about four times the copper area for the same run. When a branch needs conductors heavier than about 14 AWG, a local supply near the cameras is often the simpler option. Check the terminal wire range of both the camera and the supply before choosing heavy cable.<\/p>\n<h2 id=\"central-or-local-supply\"><span class=\"ez-toc-section\" id=\"Central_or_Local_Supply_Choosing_an_LRS_Model\"><\/span>Central or Local Supply: Choosing an LRS Model<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A central supply simplifies maintenance and battery backup; local supplies shorten the low-voltage runs. In the example, the bullets and domes stay on a central supply, while each PTZ camera needs a local supply, because even 12 AWG leaves its branch below 10.8 V.<\/p>\n<p>With the PTZs moved to local supplies, the central load drops to 8 \u00d7 0.5 + 2 \u00d7 0.6 = 5.2 A. That is 31% of the LRS-200-12 rating and within its 8.5 A limit at 70 \u00b0C.<\/p>\n<div class=\"table-wrap table-wrap-fit\">\n<table>\n<caption>WEHO 12 V LRS models in the final example layout (WEHO datasheets dated 2026-11-13)<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">\u0645\u0627\u0688\u0644<\/th>\n<th scope=\"col\">Rated output and AC input<\/th>\n<th scope=\"col\">Load allowed at 70 \u00b0C<\/th>\n<th scope=\"col\">Role in example<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>LRS-50-12<\/td>\n<td>12 V,<br \/>0\u20134.2 A;<br \/>85\u2013264 VAC<\/td>\n<td>230 VAC curve:<br \/>60% (2.52 A).<br \/>115 VAC: to be confirmed<\/td>\n<td>Local supply for one PTZ (2.0 A)<\/td>\n<\/tr>\n<tr>\n<td>LRS-200-12<\/td>\n<td>12 V,<br \/>0\u201317 A;<br \/>90\u2013132 \/ 180\u2013264 VAC by switch<\/td>\n<td>50% (8.5 A)<\/td>\n<td>Central supply for 8 bullets and 2 domes (5.2 A)<\/td>\n<\/tr>\n<tr>\n<td>LRS-350-12<\/td>\n<td>12 V,<br \/>0\u201329 A;<br \/>90\u2013132 \/ 180\u2013264 VAC by switch<\/td>\n<td>60% (17.4 A)<\/td>\n<td>Not needed here; for larger central loads<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure class=\"product\">\n<a href=\"https:\/\/www.wehopower.com\/ur\/product\/lrs-series-200w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"LRS-200 series product details, including the 12 V LRS-200-12\"><br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/lrs-200-24-enclosed-power-supply.webp\" alt=\"WEHO LRS-200-24 nameplate shows 24 V 8.8 A, screw terminals and 115\/230 V selector label\" width=\"1000\" height=\"1000\" decoding=\"async\" data-image-role=\"product\" title=\"\"><br \/>\n<\/a><figcaption>Official WEHO product photo. The nameplate reads LRS-200-24, 24 V 8.8 A. This article specifies the 12 V LRS-200-12, which uses the same 215 \u00d7 115 \u00d7 30 mm housing on the WEHO datasheet. No photograph of the -12 suffix is available yet.<\/figcaption><\/figure>\n<p>For a local PTZ position, the <a href=\"https:\/\/www.wehopower.com\/ur\/product\/lrs-series-50w-ac-to-dc-single-output-switching-power-supply\/\">LRS-50-12 12 V 4.2 A enclosed supply<\/a> carries 2.0 A at 48% of rating. Its datasheet lists no IP or waterproof rating, so it needs a suitable enclosure and an AC feed at the pole or junction box. Its 70 \u00b0C curve is drawn for 230 VAC input; on 115\/120 VAC sites, measure the pole-box temperature and ask WEHO engineering for the 115 VAC value.<\/p>\n<p>The assumed 3.0 A PTZ start-up peak is above the 2.52 A allowed at 70 \u00b0C on the 230 VAC curve, so confirm the start-up current against the curve at the enclosure temperature.<\/p>\n<p>If a larger central load must stay in one hot enclosure, the <a href=\"https:\/\/www.wehopower.com\/ur\/product\/lrs-series-350w-ac-to-dc-single-output-switching-power-supply\/\">LRS-350-12 12 V 29 A enclosed supply<\/a> allows 17.4 A at 70 \u00b0C on its curve. The LRS-200 and LRS-350 use an input selector switch, so set it to the site voltage before power-up.<\/p>\n<p>If you are still deciding the DC voltage itself, compare options in <a href=\"https:\/\/www.wehopower.com\/ur\/news\/power-supply-for-cctv-cameras-12v-vs-24v-selection-guide\/\">our 12V vs 24V CCTV selection guide<\/a>. For runtime during outages, see <a href=\"https:\/\/www.wehopower.com\/ur\/news\/12v-cctv-power-supply-with-battery-backup\/\">12V CCTV power supply with battery backup<\/a>.<\/p>\n<p>The LRS output is adjustable by \u00b110%. Raising it to offset drop is only appropriate on a dedicated branch: on the 12 AWG PTZ branch set to 13.2 V, the camera sees about 11.9 V at 2.0 A but about 12.9 V at an assumed 0.5 A idle current. Confirm that value against the camera&#8217;s maximum input first.<\/p>\n<h2 id=\"commissioning-checks\"><span class=\"ez-toc-section\" id=\"Commissioning_Checks_Before_Handover\"><\/span>Commissioning Checks Before Handover<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li>Record the camera schedule: model, maximum current, one-way length and conductor size for each branch. Verify it against the calculation above.<\/li>\n<li>Measure voltage at the supply terminals and at the farthest camera with IR, heaters and PTZ motion active. Record both values; the camera-end value must meet the camera datasheet minimum.<\/li>\n<li>Measure enclosure air temperature near the supply under load. Compare it with the derating curve of the exact model.<\/li>\n<li>Power-cycle the whole system and record whether any camera reboots or any supply enters overload protection.<\/li>\n<\/ol>\n<p>AC-side wiring and protective earth connections should be completed and checked by a qualified electrician with the circuit isolated.<\/p>\n<h2 id=\"request-a-model-check\"><span class=\"ez-toc-section\" id=\"Send_Your_Camera_Schedule_for_a_Model_Check\"><\/span>Send Your Camera Schedule for a Model Check<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>If you are specifying a project, send WEHO your camera list, worst-case currents, cable gauge and one-way length per branch, enclosure temperature and AC input through the <a href=\"https:\/\/www.wehopower.com\/ur\/contact\/\">WEHO project enquiry form<\/a>. Ask us to check whether an LRS model and its derating curve fit that load before you order samples.<\/p>\n<h2 id=\"faq\"><span class=\"ez-toc-section\" id=\"FAQ\"><\/span>\u0627\u06a9\u062b\u0631 \u067e\u0648\u0686\u06be\u06d2 \u06af\u0626\u06d2 \u0633\u0648\u0627\u0644\u0627\u062a<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"faq-calculate-voltage-drop\"><span class=\"ez-toc-section\" id=\"How_do_I_calculate_voltage_drop_on_a_12V_CCTV_cable\"><\/span>How do I calculate voltage drop on a 12V CCTV cable?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Multiply the branch current by twice the one-way length and by the conductor resistance per meter. For 1.0 A over 30 m of 18 AWG copper, the drop is 1.0 \u00d7 60 \u00d7 0.0210 = 1.26 V, leaving 10.74 V from a 12.0 V supply.<\/p>\n<h3 id=\"faq-maximum-distance\"><span class=\"ez-toc-section\" id=\"What_is_the_maximum_cable_distance_for_a_12V_camera\"><\/span>What is the maximum cable distance for a 12V camera?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>There is no single maximum; it depends on current, gauge and the camera&#8217;s minimum voltage. With a 1.2 V budget, a 0.5 A camera on 18 AWG copper reaches about 57 m one way, but a 2.0 A PTZ reaches only about 14 m.<\/p>\n<h3 id=\"faq-raise-output\"><span class=\"ez-toc-section\" id=\"Can_I_raise_the_supply_voltage_to_make_up_for_voltage_drop\"><\/span>Can I raise the supply voltage to make up for voltage drop?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Only on a dedicated branch, and only after checking the camera&#8217;s maximum input. The camera sees a higher voltage when its current falls, so a setting that is correct at full load can be too high at idle.<\/p>\n<h3 id=\"faq-central-or-local\"><span class=\"ez-toc-section\" id=\"Should_I_use_one_central_supply_or_several_local_supplies\"><\/span>Should I use one central supply or several local supplies?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Use a central supply when every branch passes the voltage-drop check at its worst-case current. Where a branch fails even with heavier cable, a local supply near that camera group is usually the simpler fix.<\/p>\n<p class=\"sources\"><strong>Sources:<\/strong> <a href=\"https:\/\/nvlpubs.nist.gov\/nistpubs\/Legacy\/hb\/nbshandbook100.pdf\" target=\"_blank\" rel=\"noopener\">NIST Handbook 100, Copper Wire Tables (1966), Table 11<\/a>; WEHO LRS-50, LRS-200 and LRS-350 datasheets with curves, dated 2026-11-13, downloadable from the product pages linked above.<\/p>","protected":false},"excerpt":{"rendered":"<p>By WEHO Electronics \u00b7 Published August 15, 2026 \u00b7 Updated November 17, 2026 Conceptual diagram and worked example: both conductors carry the branch current, so the drop uses the loop length 2L. Values shown are the 2.0 A PTZ branch on 60 m of 12 AWG in Step 2. Not a photograph or a measured&hellip; <a class=\"more-link\" href=\"https:\/\/www.wehopower.com\/ur\/news\/security-power-supply-for-cctv-systems-sizing-voltage-drop-and-cable-distance-guide\/\">\u067e\u0691\u06be\u0646\u0627 \u062c\u0627\u0631\u06cc \u0631\u06a9\u06be\u06cc\u06ba <span class=\"screen-reader-text\">CCTV Power Supply Sizing: 12V Camera Load, Voltage Drop and Cable Distance<\/span><\/a><\/p>","protected":false},"author":4,"featured_media":22268,"parent":0,"menu_order":598,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[149,148],"class_list":["post-16245","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-blog","news_category-industry-news","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/news\/16245","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/comments?post=16245"}],"version-history":[{"count":10,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/news\/16245\/revisions"}],"predecessor-version":[{"id":22317,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/news\/16245\/revisions\/22317"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/media\/22268"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/media?parent=16245"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/news_category?post=16245"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}